Search PubMed⌕ Search

Biomedical subjects

Matthew S Brown

Publications and source records attributed to Matthew S Brown.

8 recordsLinked to original sources

Pulmonary nodule characterization: a comparison of conventional with quantitative and visual semi-quantitative analyses using contrast enhancement maps.

PURPOSE: To determine whether conventional nodule densitometry or analysis based on contrast enhancement maps of indeterminate lung nodules imaged with contrast-enhanced CT can distinguish benign from malignant lung nodules. MATERIALS AND METHOD: Thin section, contrast-enhanced CT (baseline, and post-contrast series acquired at 45, 90,180, and 360 s) was performed on 29 patients with indeterminate lung nodules (14 benign, 15 malignant). A thoracic radiologist identified the boundary of each nodule using semi-automated contouring to form a 3D region-of-interest (ROI) on each image series. The post-contrast series having the maximum mean enhancement was then volumetrically registered to the baseline series. The two series were subtracted volumetrically and the subtracted voxels were quantized into seven color-coded bins, forming a contrast enhancement map (CEM). Conventional nodule densitometry was performed to obtain the maximum difference in mean enhancement values for each nodule from a circular ROI. Three thoracic radiologists performed visual semi-quantitative analysis of each nodule, scoring each map for: (a) magnitude and (b) heterogeneity of enhancement throughout the entire volume of the nodule on a five-point scale. Receiver operator characteristic (ROC) analysis was conducted on these features to evaluate their diagnostic efficacy. Finally, 14 quantitative texture features were calculated for each map. A statistical analysis was performed to combine the 14 texture features to a single factor. ROC analysis of the derived aggregate factor was done as an indicator of malignancy. All features were analyzed for differences between benign and malignant nodules. RESULTS: Using 15 HU as a threshold, 93% (14/15) of malignant and 79% (11/14) of benign nodules demonstrated enhancement. The ROC curve when higher values of enhancement indicate malignancy was generated and area under the curve (AUC) was 0.76. The visually scored magnitude of enhancement was found to be less effective in distinguishing malignant from benign lesions, with an average AUC of 0.62. The visually scored pattern of enhancement was found to be more effective with an average AUC of 0.79. From the statistical analysis performed to combine the texture features to a single factor, the area under the ROC curve was 0.84. CONCLUSION: The present study suggests that visual semi-quantitative and quantitative characterization of contrast enhancement patterns may potentially enhance the discrimination between benign and malignant nodules. Further studies and correlation with pathologic material will be important to better understand the potential interplay between CT enhancement features, host stromal elements, and neovascularity that may contribute to these patterns.

Adult↗

Solitary pulmonary nodule diagnosis on CT: results of an observer study.

RATIONALE AND OBJECTIVES: To investigate the performance of observers with different levels of experience in distinguishing between benign and malignant solitary pulmonary nodules (SPN) on CT, and to determine the effects on interpretation of three different conditions: image data alone, the addition of clinical data, and the addition of output from a computer-aided diagnosis (CAD) system. MATERIALS AND METHODS: 28 thin-section CT datasets of SPNs with proven diagnoses (15 malignant and 13 benign) were used to measure observer performance. Readers were categorized according to their experience and read the cases in random order. For each case readers were asked to assign a level of confidence on a scale from 0.0-1.0 (0.0 benign, 1.0 malignant) for the diagnosis of the nodule. Each reader scored the cases based on review of image data alone (phase 1), then with limited clinical data (phase 2), and finally with CAD output (phase 3). To assess performance, multiple reader multiple case (MRMC) receiver operating characteristic (ROC) analysis was used. RESULTS: 2 thoracic radiologists, 1 thoracic radiology fellow, 2 nonthoracic radiologists, and 3 radiology residents read the cases. The average area under the ROC curve for all readers (A(z)) at each stage was 0.68, 0.75, and 0.81, for image data alone, with clinical data, and with CAD output respectively. The difference in performance between phases (2 and 3) and (1 and 3) was significantly different (P = 0.018 and P = 0.020). However, the difference between phases (1 and 2) was not significantly different (P = 0.155). CONCLUSION: Diagnostic performance increased significantly with the addition of CAD output. With further validation CAD output may play a significant role in SPN management.

Diagnosis, Computer-Assisted↗

Computer-aided lung nodule detection in CT: results of large-scale observer test.

RATIONALE AND OBJECTIVES: The objective is to study the incremental effects of using a computer-aided lung nodule detection (CAD) system on the performance of a large pool of observers. MATERIALS AND METHODS: A set of eight thin-section computed tomographic data sets with limited longitudinal coverage, containing a total of 22 lung nodules, was analyzed by using the automated nodule detection system. When applied to all eight cases, the CAD system alone achieved a detection rate of 86.4%, with 2.64 false-positive results per case. This study included 202 observers at a national radiology meeting: 39 thoracic radiologists, 95 non-thoracic radiologists, and 68 non-radiologists. Each participant read from one to eight cases in random order, first without and then with CAD system output available. Observer performance in nodule detection was measured before and after CAD was made available. Differences in performance of groups of observers before and after CAD were tabulated by mean, median, and SD in detection rate and number of false-positive results and tested by using nonparametric methods. RESULTS: In an analysis involving only the first randomly selected case read by all 202 participants, there were statistically significant increases in nodule detection rates and numbers of false-positive results for all types of observers. There was a significant difference in detection rates between radiologists and non-radiologists before CAD, but after CAD, there was no significant difference in detection rates between these observer types. In a second analysis involving 13 participants who read all eight cases, mean detection rates were 64.0% before CAD and 81.9% after CAD. Mean numbers of false-positive results were 0.144 per case before CAD and 0.173 after CAD. CONCLUSION: In a large observer study, use of a CAD system for nodule detection resulted in an incremental increase in detection rate, but also led to an increase in number of false-positive results. Also, CAD appears to be an equalizer of detection rates between observers of different levels of experience.

Clinical Competence↗

Database design and implementation for quantitative image analysis research.

Quantitative image analysis (QIA) goes beyond subjective visual assessment to provide computer measurements of the image content, typically following image segmentation to identify anatomical regions of interest (ROIs). Commercially available picture archiving and communication systems focus on storage of image data. They are not well suited to efficient storage and mining of new types of quantitative data. In this paper, we present a system that integrates image segmentation, quantitation, and characterization with database and data mining facilities. The paper includes generic process and data models for QIA in medicine and describes their practical use. The data model is based upon the Digital Imaging and Communications in Medicine (DICOM) data hierarchy, which is augmented with tables to store segmentation results (ROIs) and quantitative data from multiple experiments. Data mining for statistical analysis of the quantitative data is described along with example queries. The database is implemented in PostgreSQL on a UNIX server. Database requirements and capabilities are illustrated through two quantitative imaging experiments related to lung cancer screening and assessment of emphysema lung disease. The system can manage the large amounts of quantitative data necessary for research, development, and deployment of computer-aided diagnosis tools.

Algorithms↗

Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography.

RATIONALE AND OBJECTIVES: To study the agreement in treatment response classifications between unidimensional (1D), bidimensional (2D), and volumetric (3D) methods of measuring metastatic lung nodules on chest computed tomography (CT). MATERIALS AND METHODS: Chest CT scans of 15 patients undergoing treatment for metastatic colorectal, renal cell, or breast carcinoma to the lungs were analyzed. CT images were acquired with 3 mm collimation and contiguous reconstruction. Two or three lung lesions were selected for each patient. Lesions were analyzed at baseline and two follow-up intervals of 1-4 months. 1D and 2D measurements were made with electronic calipers, while nodule volume was measured using a semiautomated segmentation system. Following the World Health Organization and RECIST (Response Evaluation Criteria in Solid Tumors) criteria, patients were categorized into four treatment response classifications. Volumetric criteria were used to classify response based on 3D measurements. RESULTS: Thirty-two lesions from 15 patients were analyzed. Because each patient had a baseline and two follow-up scans, this yielded 30 response classifications for each measurement technique. The 1D, 2D, and 3D measurements were concordant in 21 of 30 classifications. The 1D and 3D measurements were concordant in 29 of 30 classifications, while the 2D and 3D measurements were concordant in 23 of 30 classifications. Level of agreement among the three methods was measured using a kappa statistic (K). For 1D compared with 3D, K = 0.739 +/- 0.345 (visits 1, 2) and 0.273 +/- 0.323 (visits 2, 3). For 2D compared with 3D, K = 0.655 +/- 0.325 (visits 1, 2) and 0.200 +/- 0.208 (visits 2, 3). Agreement among the methods for round and ovoid nodules was also fair to poor. CONCLUSION: The three methods of tumor measurement show fair to poor agreement in treatment response classification. These findings have negative implications for the accuracy in which patients are classified under the World Health Organization or RECIST criteria and managed under cancer treatment protocols.

Breast Neoplasms↗

Emphysema: effect of reconstruction algorithm on CT imaging measures.

In the current study, the effects of reconstruction algorithms on quantitative measures derived from computed tomographic (CT) lung images were assessed in patients with emphysema. CT image data sets were reconstructed with a standard algorithm and alternative algorithm(s) for 42 subjects. Algorithms were grouped as overenhancing, sharp, standard, or smooth. Density mask and volume measurements from the alternative algorithm data sets were compared with standard algorithm data sets. The overenhancing category yielded an average shift of 9.4% (ie, a shift in average score from 35.5% to 44.9%); the sharp category, a shift of 2.4%; and the smooth category, a shift of -1.0%. Differences in total lung volume measurements were less than 1%. In conclusion, the CT reconstruction algorithm may strongly affect density mask results, especially for certain reconstruction algorithms.

Aged↗

Lung micronodules: automated method for detection at thin-section CT--initial experience.

An automated system was developed for detecting lung micronodules on thin-section computed tomographic images and was applied to data from 15 subjects with 77 lung nodules. The automated system, without user interaction, achieved a sensitivity of 100% for nodules (>3 mm in diameter) and 70% for micronodules (<or=3 mm). With the same images, a radiologist detected nodules and micronodules with sensitivities of 91% and 51%, respectively, without system input. With assistance from the automated system, these sensitivities increased to 95% and 74%, respectively. Preliminary results indicate that the automated system considerably improved the radiologist's performance in micronodule detection.

Aged↗

Medical image segmentation with knowledge-guided robust active contours.

Medical image segmentation techniques typically require some form of expert human supervision to provide accurate and consistent identification of anatomic structures of interest. A novel segmentation technique was developed that combines a knowledge-based segmentation system with a sophisticated active contour model. This approach exploits the guidance of a higher-level process to robustly perform the segmentation of various anatomic structures. The user need not provide initial contour placement, and the high-level process carries out the required parameter optimization automatically. Knowledge about the anatomic structures to be segmented is defined statistically in terms of probability density functions of parameters such as location, size, and image intensity (eg, computed tomographic [CT] attenuation value). Preliminary results suggest that the performance of the algorithm at chest and abdominal CT is comparable to that of more traditional segmentation techniques like region growing and morphologic operators. In some cases, the active contour-based technique may outperform standard segmentation methods due to its capacity to fully enforce the available a priori knowledge concerning the anatomic structure of interest. The active contour algorithm is particularly suitable for integration with high-level image understanding frameworks, providing a robust and easily controlled low-level segmentation tool. Further study is required to determine whether the proposed algorithm is indeed capable of providing consistently superior segmentation.

Algorithms↗