Publications and source records attributed to Matthew B Kerby.

5 recordsLinked to original sources

Measurements of kinetic parameters in a microfluidic reactor.

Continuous flow microfluidic reactors that use immobilized components of enzymatic reactions present special challenges in interpretation of kinetic data. This study evaluates the difference between mass-transfer effects and reduced efficiencies of an enzyme reaction. The kinetic properties of immobilized alkaline phosphatase (AP) were measured by the dephosphorylation of 6,8-difluoro-4-methylumbelliferyl/phosphate to a fluorescent 6,8-difluoro-4-methylumbelliferone. A glass microfluidic chip with an in-channel weir was created for the capture of solid silica microbeads functionalized with enzyme. The input substrate concentrations and flow rates across the bed were varied to probe the flow-dependent transport and kinetic properties of the reaction in the microreactor bed. Unlike previous reactors, substrate was titrated directly over the fixed enzyme bed by controlling the air pressure over the chip reservoirs. The reactor explored substrate conversions from near zero to 100%. The average bed porosity, residence time, and bed resistance were measured with dye pulses. A simple criterion was derived to evaluate the importance of flow-dependent mass-transfer resistances when using microreactors for calculating kinetic rate constants. In the absence of mass-transfer resistances, the Michaelis-Menten kinetic parameters are shown to be flow independent and are appropriately predicted using low substrate conversion data. A comparison of the kinetic parameters with those obtained using solution-phase enzymatic reactions shows a significant decrease in enzyme activity in the immobilized conformation. The immobilized Km of AP is approximately 6 times greater while the kcat is reduced by approximately 28 times. Contradictions found in literature on the evaluation of Michaelis-Menten kinetic parameters for immobilized enzymes in microfluidic reactors are addressed. When product molecules occupy a significant number of enzymatic sites or modify the enzyme activity, the assumed Michaelis-Menten mechanism can no longer be valid. Under these conditions, the calculations of "apparent" kinetic rate constants, based on Michaelis-Menten kinetics, can superficially show a dependence on flow rate conditions even in the absence of mass-transfer resistances. High substrate conversions are shown to depend on flow rate. A kinetic model based on known mechanisms of the alkaline phosphatase enzyme reaction is tested to predict the measurements for high substrate conversion. The study provides a basis for appropriate use of mass-transfer and reaction arguments in successful application of enzymatic microreactors.

Adsorption↗

Selective ion extraction: a separation method for microfluidic devices.

A separation concept, selective ion extraction (SIE), is proposed on the basis of the combination of hydrodynamic and electrokinetic flow controls in microfluidic devices. Using a control system with multiple pressure and voltage sources, the hydrodynamic flow and electric field in any section of the microfluidic network can be set to desired values. Mixtures of compounds sent into a T-junction on a chip can be completely separated into different channels on the basis of their electrophoretic mobilities. A simple velocity balance model proved useful for predicting the voltage and pressure settings needed for separation. SIE provides a highly efficient separation with minimal additional dispersion. It is an ideal technique for high-throughput screening systems and demonstrates the power of lab-on-a-chip systems.

Journal Article↗

Increase of separation resolution through field enhancement in microchips.

An enhanced ability to separate charged species from neutral compounds in a microfluidic chip is demonstrated using a chip design with low-resistance electrode channels operating with a multiport pressure/voltage controller. A factor of 2.7 improvement in resolution was obtained from chips made using identical mask designs but different etch depth protocols. Greater separation power allows one to cover a wider dynamic range for compounds with different electrophoretic mobilities.

Arginine↗

Characterization of the in vitro adherence behavior of ultrasound responsive double-shelled microspheres targeted to cellular adhesion molecules.

We have developed novel adhesion molecule-targeted double-shelled microspheres which encapsulate nitrogen. We report in vitro targeting studies utilizing these microspheres conjugated to target-specific antibodies directed towards ICAM-1 and VCAM-1. In static adherence experiments, the adherence patterns of microspheres conjugated to three different monoclonal antibodies (two targeted to ICAM-1 and one to VCAM-1) to their target surfaces were very different. Maximum microsphere adherence at the lowest target and/or ligand densities was observed with the VCAM-1 system. Differences in target-specific adherence were also observed between anti-ICAM-1 and anti-VCAM-1 microsphere conjugates in flow adherence studies. Equilibrium binding studies of the target proteins in solution to the microsphere-bound ligands showed that the affinity constants of two microsphere-bound monoclonal antibodies for their target proteins are similar. Thus, ligand-target affinity is not the only determinant of microsphere adherence to the target surface in our systems. Shear stress was found to have an effect on the mean diameter of adhered microspheres; a decrease in the mean diameter with increasing shear was observed. The magnitude of this effect was dependent on both microsphere-bound ligand and target surface densities, with a more pronounced change at lower densities. Adhered microspheres were readily detectable using ultrasound at the lowest tested surface density of 40 mm(-2).

Adhesiveness↗

Kinetic measurements of protein conformation in a microchip.

This paper presents a microchip-based system for collecting kinetic time-based information on protein refolding and unfolding. Dynamic protein conformational change pathways were studied in microchannel flow using a microfluidic device. We present a protein-conserving approach for quantifying refolding by dynamically varying the concentration of the chemical denaturants, guanidine hydrochloride and urea. Short diffusion distances in the microchannel result in rapid equilibrium between protein and titrating solutions. Dilutions on the chip were tightly regulated using pressure controls rather than syringe-based flow, as verified with extensive on-chip tracer dye controls. To validate this protein assay method, folding transition experiments were performed using two well-characterized proteins, human serum albumin (HSA) and bovine carbonic anhydrase (BCA). Transition events were monitored through fluorescence intensity shifts of the protein dye 8-anilino-1-naphthalenesulfonic acid (ANS) during dilutions of protein from urea or guanidine hydrochloride solutions. The enzymatic activity of refolded BCA was measured by UV absorption through the conversion of p-nitrophenyl acetate (p-NPA). The microchip protein refolding transitions using ANS were well-correlated with conventional plate-based experiments. The microfluidic platform enables refolding studies to identify rapidly the optimal folding strategy for a protein using small quantities of material.

Animals↗