Wilson's disease tremor is associated with magnetic resonance imaging lesions in basal ganglia structures.

Wilson's disease (WD) is an inherited disorder of copper metabolism yielding marked motor deficits, including a severely disabling tremor. As a structural correlate of the disease, a variety of cerebral abnormalities has been revealed. However, the relationship between motor deficits and cerebral lesions has remained largely unknown. Here, we investigated correlation between WD tremor and cerebral magnetic resonance imaging (MRI) findings. Cerebral MRI abnormalities in 6 symptomatic WD patients were compared to findings in 6 asymptomatic WD patients and 10 healthy controls. All patients were treated with long-term copper chelating therapy. Motor symptoms including tremor were determined by Unified Parkinson's Disease Rating Scale Part III (UPDRS-III). MRI findings in symptomatic WD patients revealed significant symmetric T2*-weighted hypointense signal alterations of globus pallidus, head of the caudate nucleus, and substantia nigra. In contrast, MRI of asymptomatic WD patients did not differ from healthy controls. Correlation analysis revealed a significant positive correlation between MRI basal ganglia lesions and UPDRS action tremor score. Our results demonstrate for the first time that Wilson's disease tremor is associated with lesions of the globus pallidus, the head of the caudate nucleus, and the substantia nigra.

Adult↗

Multi-detector CT-colonography in inflammatory bowel disease: prospective analysis of CT-findings to high-resolution video colonoscopy.

AIM: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). MATERIALS AND METHODS: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. RESULTS: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. CONCLUSION: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity.

Adult↗

Recurrent embolism in the course of marantic endocarditis.

Marantic or nonbacterial thrombotic endocarditis (NBTE) associated with systemic embolism is usually a complication of advanced or terminal malignancies. We report on the case of a 46-year-old woman in whom nonbacterial thrombotic endocarditis (NBTE)-related cerebral embolism was the first clinical sign of ovarian neoplasm, which was diagnosed after cardiac surgery. Marantic endocarditis should alert the physician to make every effort to diagnose the possible background of this clinical phenomenon. Early identification of NBTE, treatment of the underlying disease, and the associated coagulopathy could possibly prevent cardiac surgery.

Blood Coagulation Disorders↗

[TierSPECT: performance of a dedicated small-animal-SPECT camera and first in vivo measurements].

This paper presents the performance of a new small-animal camera (TierSPECT) devised for the in vivo measurements of radiolabeled substances in small laboratory animals such as mice and rats. In a scatter medium, the camera has a tomographic spatial resolution of 2.87 mm and a sensitivity of 22 cps/MBq in a usable Field-of-View (FOV) with a diameter of 82 mm. The planar homogeneity amounts to 3.3%, the tomographic homogeneity lies between 3.2% and 3.5%. The deviation between filled and measured concentration of activity in a cylindrical 4-chamber-phantom was smaller than 2.6%. Using a novel rat head phantom with chamber volumes in the order of magnitude of the spatial resolution (between 0.065 ml and 0.19 ml) it could be demonstrated that studies of the rat neostriatal dopaminergic system are feasible under observance of physiological conditions. In vivo studies using [99mTc]diphosphonato-1,2-propandicarbonic acid (99mTc-DPD) and [123I]N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodophenyl)-nortropane (123I-FP-CIT) proved that bone metabolism and dopamine transporter binding can be visualized with the TierSPECT. The fusion of 99mTc-DPD and 123I-FP-CIT images allowed the differentiation between intra- and extracerebral structures. Pretreatment with methylphenidate resulted in blockade of striatal dopamine transporter binding.

Animals↗

Coverage of anterior fossa in whole-brain irradiation.

PURPOSE: Whole-brain irradiation is indispensable in the treatment of several brain tumors and requires coverage of the entire subarachnoid space. Retrospective studies have revealed frequent recurrences in the frontobasal fossa above the cribriform plate (CP). We sought to determine how accurately the latter could actually be identified on lateral radiographs such as those used for radiotherapy planning. METHODS AND MATERIALS: The CP was localized by five radiation oncologists and five radiologists on lateral radiographs of 30 human skulls from an anatomic collection. Reference radiographs were acquired under identical conditions except for lead markers pointing to the CP and the ethmoid cells. The targeting accuracy was analyzed. RESULTS: In 39% (n = 116), the location of the CP was correctly estimated within 2 mm. Mislocations of 2-5, 5-10, and >10 mm were noted in 34% (n = 102), 20% (n = 61), and 7% (n = 21), respectively. Neither specialty nor experience (years of training) exerted a significant influence on targeting accuracy. If the roofs of the ethmoid cells formed prominent bony edges, they were mistaken for the CP in 37%. CONCLUSION: Lateral radiographs provide insufficient information to locate the CP accurately in whole brain irradiation. Additionally, localization was significantly impaired by prominent ethmoid cells.

Adult↗

Detection of colorectal polyps by multislice CT colonography with ultra-low-dose technique: comparison with high-resolution videocolonoscopy.

BACKGROUND: This prospective study compared multislice CT colonography with ultra-low-dose technique to high-resolution videocolonoscopy as the standard for detection of colorectal cancer and polyps. METHODS: After standard bowel preparation, 115 patients underwent multislice CT colonography with an ultra-low-dose multislice CT colonography protocol immediately before videocolonoscopy. After noise reduction by using a mathematical algorithm, ultra-low-dose multislice CT colonographic images were analyzed in blinded fashion, and the results were compared with the results of high-resolution videocolonoscopy. RESULTS: A total of 150 lesions were detected by high-resolution videocolonoscopy in 115 patients. For ultra-low-dose multislice CT colonography, sensitivities for detection of polyps less than 5 mm in size, 5 to 10 mm, and greater than 10 mm in diameter were 76%, 91%, and 100%, respectively. Although the sensitivity for detection of flat lesions was only 50%, the sensitivity and the specificity for detection of polyps 5 mm or greater in size were 94% and 84%, respectively. For adenomatous lesions greater than 5 mm in size, sensitivity was 94% and specificity was 92%. The overall specificity was 79%. The calculated effective radiation dose ranged between 0.75 and 1.25 mSv. CONCLUSIONS: Compared with high-resolution videocolonoscopy, ultra-low-dose multislice CT colonography has excellent sensitivity and specificity for detection of colorectal lesions 5 mm or greater in size, and the radiation exposure is relatively low. However, before this technique can be generally recommended for colorectal screening, further improvement in the detection of flat and extremely small lesions must be achieved.

Adult↗

Feasibility of MDCT Colonography in ultra-low-dose technique in the detection of colorectal lesions: comparison with high-resolution video colonoscopy.

OBJECTIVE: The purpose of this study was to assess the feasibility of MDCT colonography in an ultra-low-dose technique in the detection of endoluminal colonic lesions compared with high-resolution video colonoscopy. SUBJECTS AND METHODS: After standard bowel cleansing, 137 patients (77 men, 60 women; mean [+/- SD] age, 57.1 +/- 11.3 years) underwent high-resolution video colonoscopy within 2 hr after ultra-low-dose MDCT colonography had been performed. Ultra-low-dose MDCT colonography was performed with patients in the supine position only using 10 mAs (effective weighted CT dose index, 0.94 mGy). After mathematic noise reduction by nonlinear gaussian filter chains, using dedicated software (ECCET), images were analyzed by two blinded observers in simultaneously displayed interactive 2D and 3D modes. Findings of ultra-low-dose MDCT colonography were compared with the results obtained with high-resolution video colonoscopy. RESULTS: Calculated effective doses were 0.7 and 1.2 mSv for men and women, respectively. Ultra-low-dose MDCT colonography detected 84 (62%) of 135 lesions: 11 (78.6%) of 14 large polyps (> 10 mm), 12 (85.7%) of 14 medium polyps (9.9-5 mm), and 61 (57%) of 107 small polyps (< 5 mm). On a patient-by-patient basis, an overall sensitivity of 70.3% with a specificity of 80.8% was calculated. False-positive findings were seen mostly for small lesions (eight medium and 29 small lesions). Two of the three false-negative lesions were retrospectively detected in contrast-enhanced cleansing fluid; one was a flat lipoma not detectable on ultra-low-dose MDCT colonography. CONCLUSION: Despite an effective dose of approximately 1 mSv, MDCT colonography using an ultra-low-dose technique performs as well as MDCT colonography with a standard dose, according to published data. After mathematic noise reduction, 82% of polyps larger than 5 mm can be detected.

Colon↗

[Virtual colonography].

Recent technical developments in computed tomography (CT) and magnetic resonance imaging (MRI) have made a virtual presentation of the colon possible. The results of clinical investigations comparing virtual colonography and conventional colonoscopy up to now are promising. Virtual colonography is a potential tool for colorectal carcinoma screening in the future, but it still has an unsatisfactory sensitivity for the detection of small and flat lesions and exposes the patient to substantial doses of ionizing radiation. Recent investigations using ultra-low-dose (< 2 mSv) multislice CT colonography show promising results. Magnetic resonance (MR) colonography as a radiation-free modality is the technique of the future. Although encouraging results using virtual MR colonography for the detection of colorectal polyps have been reported, the sensitivity of detecting small polyps (</= 10 mm) and flat lesions is poor. Main reason is the limited spatial resolution in MRI of the colon. The potential role of virtual colonography in the prevention of colorectal cancer is not yet clear. Larger studies with asymptomatic persons at average risk are needed, and further improvements in the detection of flat and very small (< 5 mm) lesions need to be achieved before advocating the use of virtual colonography for routine colorectal cancer screening.

Adenoma↗

A rapid and reliable semiautomated method for measurement of total abdominal fat volumes using magnetic resonance imaging.

The aim of this study was the development of a reliable and fast method to estimate total abdominal fat volumes (TAF) in diabetic subjects on the basis of T1-weighted MR images. Thirty-seven patients with diabetes were examined (age 48 +/- 13 y mean +/- SD). A semiautomated computer assisted software program was developed to quantify intraabdominal (IAF), subcutaneous (SCF), and total abdominal fat volumes (TAF). The variability of image analysis for fat measurements between two observers and within observers was assessed. Mean volumes (+/- SD) for IAF, SCF and TAF were 10.5 1 (+/- 5.0 1), 15.1 1 (+/-7.3 1) and 25.7 1 (+/-11.5 1), respectively. Inter- and intraobserver reliability was excellent (r = 0.999 to r = 1.0). Per patient, the analysis required nine minutes in addition to a scan duration of seven minutes. As this analytic method using T1-weighted MR images allows a fast and reliable quantification of TAF, IAF and SCF, it may serve as a valuable tool for respective studies in diabetic subjects.

Abdomen↗

Improvement of sonographic needle visibility in cirrhotic livers during transjugular intrahepatic portosystemic stent-shunt procedures with use of real-time compound imaging.

The visibility of a transjugular intrahepatic portosystemic stent-shunt (TIPS) puncture needle was assessed with use of real-time compound imaging and single-line ultrasonography (US). In vitro and in vivo, needle-tissue contrast was calculated. With an increasing angle of incidence, the decrease in needle visibility was more pronounced for single-line US than for compound imaging. At angles of incidence of more than 30 degrees, the needle was barely visible with either technique. Subjective evaluation during TIPS procedures in 10 patients proved that the needle tip was significantly better seen with compound imaging. Therefore, real-time compound imaging significantly improved contrast and subjective visibility of the needle.

Adult↗

Effective doses in standard protocols for multi-slice CT scanning.

The purpose of this study was to assess the radiation exposure of patients in several standard protocols in multi-slice CT (MSCT). Scanning protocols for neck, chest, abdomen, and spine were examined on a Somatom Plus 4 Volume Zoom MSCT (Siemens, Erlangen, Germany) with changing slice collimation (4x1, 4x2.5, and 4x5 mm), and pitch factors (1, 1.5, and 2). Effective doses were calculated from LiF-TLD measurements at several organ sites using an Alderson-Rando phantom and compared with calculations using the weighted CTDI. Effective dose for MSCT of the neck was 2.8 mSv. For different protocols for MSCT of the chest, 7.5-12.9 mSv were found. In abdominal MSCT protocols, effective dose varied between 12.4 and 16.1 mSv. The MSCT of the spine may lead to 12 mSv. An excellent correlation between the effective dose as determined by LiF-TLD and the calculated effective dose using the weighted CTDI could be demonstrated; however, a difference of up to 30% (mean 14.3%) was noted. Standard protocols for MSCT as measured in this study showed effective doses of up to16 mSv. Phantom measurement data show a good correlation to estimations using the weighted CTDI.

Abdomen↗

Serotonin release during percutaneous radiofrequency ablation in a patient with symptomatic liver metastases of a neuroendocrine tumor.

In a patient with symptomatic liver metastases of a neuroendocrine tumor larger than 10 cm in diameter percutaneous radiofrequency ablation was performed. The ablation resulted in a significant decrease in tumor size and a good long-term improvement of symptoms. Plasma serotonin 48 hours after the ablation was approximately 10-fold lower than before. However, sequential determination of plasma serotonin during the radiofrequency ablation revealed a two-fold increase of plasma serotonin induced by the procedure. There was also an approximately three-fold increase of 5-hydroxyindol acetic acid in urine in the 24 hours following the ablation. The data show that ablation procedures in neuroendocrine tumors may induce hormone release which may be critical in patients with severe clinical symptoms.