Radionuclides-hyaluronan-conjugate thromboresistant coatings to prevent in-stent restenosis.

Catheter-based brachytherapy is one of the most effective modalities to inhibit hyperplasia following revascularization procedures. Radioactive stents have failed, however, to prevent clinical hyperplasia due to excessive late lumen loss on the edge of the devices. Numerous strategies have been proposed to circumvent the drawbacks of irradiation therapies, such as the use of more appropriate radionuclides or the "hot-end" stents approach. This paper describes versatile radioactive devices obtained by coating plasma functionalized surfaces-stents or catheters-with a hyaluronan (HA)-diethylenetriamine pentaacetic acid (DTPA) conjugate (HA-DTPA) complexed with a gamma or beta radionuclide. Yttrium and indium were used as radionuclide models, due to their suitability for endovascular radiotherapy. X-ray photoelectron microscopy and time-of-flight secondary ions mass spectrometry analyses confirmed the successful immobilization of the HA-DTPA conjugate on both the metallic (NiTi) and polymeric (Teflon) plasma functionalized surfaces. HA-DTPA-coated surfaces were significantly more hydrophilic than bare surfaces (39.5 degrees vs. 67 degrees on NiTi substrate and 29 degrees vs. 128 degrees on Teflon substrate). Therapeutic doses of yttrium and indium were easily loaded onto the surfaces and remained stable over 2 weeks with a radionuclide loss of about 6%. The HA-DTPA-coated Teflon surfaces presented significantly less fibrinogen adsorption than uncoated materials in an in vitro flow model. This approach, which combines the hemocompatibility of HA-coated surfaces and the anti-proliferative effects of an appropriate radiotherapy, constitutes a promising methodology to alleviate the restenosis induced by existing devices.

Adsorption↗

Complex permittivity measurement as a new noninvasive tool for monitoring in vitro tissue engineering and cell signature through the detection of cell proliferation, differentiation, and pretissue formation.

In in vitro tissue engineering, microporous scaffolds are commonly used to promote cell proliferation and differentiation in three-dimensional structures. Classic measurement methods are particularly time consuming, difficult to handle, and destructive. In this study, a new nondestructive method based on complex permittivity measurement (CPM) is proposed to monitor and track the osteoblast and macrophage differentiation through their morphological variation upon cell attachment and proliferation inside the microporous scaffolds. CPM is performed using a vector network analyzer and a dielectric probe under sterile conditions in a laminar-flow hood. A suitable effective medium approximation (EMA) is applied to fit the data in order to extract the parameters of the different constituents. Our data show that the EMA depolarization factor can be monitored to assess the variation of cell morphology characterizing cell attachment. Discrimination between two batches of scaffolds seeded, respectively, with 2 million and 1 million osteoblast cells is possible; the ratio of their CPM-derived cell volume fractions is in agreement with the ratio of their cell seeding numbers. In addition, cell proliferation inside scaffolds seeded with osteoblasts cultured in alpha minimum essential medium and inside scaffolds seeded with osteoblasts cultured in alpha minimum essential medium supplemented to induce the formation of extracellular matrix is monitored via CPM over several days. CPM-determined cell volume fraction is compared to DNA assay cell counts. Extracellular matrix formation and cell presence was confirmed by scanning electron microscopy. A set of three signature parameters (epsilon'mem, epsilon'cyt, kappa'cyt) characteristic of cell line is extracted from CPM. Distinct signatures are recorded for osteoblasts and macrophages, thus confirming the ability of CPM to discriminate between different cell types. This study demonstrates the potential of CPM as a diagnostic tool to monitor quickly and noninvasively cell growth and differentiation inside microporous scaffolds. Our findings suggest that the use of CPM could be extended to many biomedical applications, such as drug detection and automation of tissue and bacterial cultures in bioreactors.

3T3 Cells↗

Towards on-line monitoring of cell growth in microporous scaffolds: Utilization and interpretation of complex permittivity measurements.

Here we demonstrate the ability to characterize microporous scaffolds and evaluate cell concentration variation via the utilization and interpretation of complex permittivity measurements (CP), a direct and nondestructive method. Polymer-based microporous scaffolds are of importance to tissue engineering, particularly in the promotion of cell adhesion, proliferation, and differentiation in predefined shapes. Chitosan gel scaffolds were seeded with increasing concentrations of macrophages to simulate cell growth. Complex permittivity measurements were performed using a dielectric probe and a vector network analyzer over a frequency ranging from 200 MHz to 2 GHz. An effective medium theory was applied to interpret the data obtained; respectively, Looyenga and Maxwell-Wagner-Hanai functions were used to retrieve the porosity and the variation of the cell concentration from the CP measurements. Calculated porosities were in agreement with experimental evaluation-porosity ranged from 81-96%. Changes in cell concentration inside the scaffolds upon injection of differing cell concentrations into the scaffold were detected distinguishably. Variations resulting from the cumulative injection of 400-1800 microL of 10(6) cells/mL solution into the scaffold were monitored. Results suggest that CP measurements in combination with an appropriate effective medium approximation can enable on-line monitoring of cell growth within scaffolds.

Algorithms↗

Nanocoatings onto arteries via layer-by-layer deposition: toward the in vivo repair of damaged blood vessels.

The deposition of polysaccharide-based self-assembled nanocoatings onto damaged arteries is described as a means not only to protect a damaged artery against thrombogenesis, but also to control the healing processes by incorporating biologically active components within the multilayer. As shown by confocal microscopy, the polysaccharide multilayer was retained on the artery in physiological condition and prevented platelet adhesion. Diffusion of the polysaccharides within the artery was also observed and may be used to efficiently target the vascular wall. The NO-precursor l-arginine was used a drug model and incorporated within the self-assembled layers.

Animals↗

Safety issue of re-sterilization of polyurethane electrophysiology catheters: a cytotoxicity study.

The reuse of electrophysiology catheters could result in significant cost savings. However, re-sterilization of catheters could lead to several adverse consequences, including toxicity related to potential chemical reactions that occur during sterilization due to toxic residues remaining on the surface of catheters. The objective of this study was to investigate in vitro cytotoxicity of polyurethane (PU)-based catheter extracts on macrophages after their re-sterilization. We have compared three sterilization methods: steam autoclave, ethylene oxide (EtO) and hydrogen peroxide plasma (Sterrad system). Our results showed that the viability of cells varied from 90% to 99% as a function of incubation time and number of sterilization cycle. While there was no statistical difference based on the sterilization procedure, the number of sterilization cycles (up to 10 cycles) presents a statistically significant effect on the viability of J774 macrophages. However, extract obtained after resterilization of PU-based catheters had a low cytotoxic effect on J774 macrophages, since the overall cell mortality remained under 10%. An inhibitory effect on cell growth was also observed, which was not significant either as a function of incubation time, sterilization technique or the number of sterilization cycles. Finally, extracts of PU-based catheters had no statistically significant effect on TNF-alpha release by J774 macrophage. Even though there were some statistically significant differences between the control and processed samples, and among processed samples, our data suggest that one single reprocessing of PU-based catheters may not induce clinically significant changes in their cytotoxicity behaviour.

Animals↗

Biocompatibility and biostability of metallic endovascular implants: state of the art and perspectives.

More than a million metallic endovascular devices are implanted each year, but the quest for the perfect material continues. The importance of interfacial properties in the overall biocompatibility of metals and alloys has been recognized for a long time. In particular, these properties modulate the hemocompatibility of devices in contact with blood and, in turn, strongly influence implantation outcomes. In this article, the relative properties of metallic materials commonly used in endovascular applications are reviewed. Particular emphasis is given to the corrosion behavior of metallic endovascular materials and the specific surface treatments used in the production processes. Issues relative to corrosion assays will also be reviewed in terms of their relevance to in vivo applications. The potential adverse effects of degradation products with respect to endovascular applications will be described. Finally, this review addresses future perspectives of metallic devices in endovascular procedures in view of the recent promises of antiproliferative strategies that are likely to profoundly modify current procedures.

Animals↗

Effect of experimental parameters on the in vitro release kinetics of transforming growth factor beta1 from coral particles.

Coral bone graft substitutes have been supplemented in the past with growth factors to further enhance bone regeneration in defects. Little is known, however, on the dynamics of protein release from coral. Coral particles were studied for their ability to release transforming growth factor beta 1 (TGF-beta1) in vitro, under different adsorption conditions. Adsorption of TGF-beta1 (0.05 microg/mL) on coral particles (<80 microm or 300-450 microm) after 24 h of incubation was high, regardless of conditions. TGF-beta1 release kinetics in an artificial bone fluid followed a specific profile: an initial 1-h protein burst, followed by a decreasing release during the next 24 h at which time the release increased again to reach a constant rate until the end of the 2-week study. The protein release rate appeared mainly to depend upon the diffusion of TGF-beta1. TGF-beta1 release from coral particles was enhanced in the presence of bovine serum albumin (BSA) compared to the release in the presence of gelatin, and was dependent on the pH of adsorption. The highest total TGF-beta1 release was obtained when adsorption occurred with BSA at pH 7.4 (82 +/- 3%), while the lowest release was observed when adsorption was done in the presence of gelatin at pH 11 (38 +/- 1%). TGF-beta1 release was also found to vary with particle size, higher release being obtained with the smaller particles. These results suggest that coral particles could be used as a delivery system for growth factors, and that the release rate may be modulated through modification of the adsorption conditions and coral particle size.

Adsorption↗

Cytotoxic reaction and TNF-alpha response of macrophages to polyurethane particles.

Their unique mechanical and biological properties make polyurethanes (PUs) ideal materials for many implantable devices. However, uncertain long-term biostability in the human physiological environment limits their extensive clinical applications. Chronic inflammatory response associated with macrophage activation has been suggested as a prime factor; although the mechanism of macrophage activation in response to biomaterial surfaces and debris is still unknown. The overall objective of this work was to study the response of macrophages to PU materials in vitro by measuring cell viability and activity. The studies were carried out using phagocytozable-size PU particles from three types of commercially-available PUs: Pellethane 2363 80ABA (PL); Tecothane TT2065 (TC65); and Tecothane TT2085 (TC85). These polymers posess the same generic composition but differ in the length of hard and soft segments, as revealed by the FTIR and NMR studies. The results showed that PU particles affected both viability and activity of J774 macrophages. The percentage of mortality ranged from 1 to 15% with 10-100 microg ml(-1) of particles after 24 and 48 h incubation. These three types of particles induced different mortality on the macrophages. Specifically, the mortality with PL particles was 1-4% (p > 0.05), while the mortality with TC85 particles was 2-10% (p < 0.05) and 4-15% with TC65 (p < 0.05). Conversely, these particles also affected cell proliferation. Cell numbers increased by 132 and 167% after 24 and 48 h incubation, respectively, without particles, whereas the cell numbers increased only 46 and 78% with TC65, 66 and 105% with TC85, and 67 and 110% with PL in the presence of 100 microg ml(-1) of particles for the respective incubation times. PU particles also increased TNF-alpha release from macrophage. After having been incubated for 24 h with 100 microg ml(-1) particles of TC65, TC85, and PL, macrophages release TNF-alpha 7.4, 5.2, and 4.1 times more than the control. In conclusion, PU particles had cytotoxic effects on J774 macrophage at high concentrations. The order of macrophage response for three types of particles was TC65 > TC85 > PL. PU particles' effect on macrophage viability and activity depends on the concentration of particles and their chemical composition, especially on the ratio of hard to soft segments.

Animals↗

Natural coral exoskeleton as a bone graft substitute: a review.

Natural coral graft substitutes are derived from the exoskeleton of marine madreporic corals. Researchers first started evaluating corals as potential bone graft substitutes in the early 1970s in animals and in 1979 in humans. The structure of the commonly used coral, Porites, is similar to that of cancellous bone and its initial mechanical properties resemble those of bone. The exoskeleton of these high content calcium carbonate scaffolds has since been shown to be biocompatible, osteoconductive, and biodegradable at variable rates depending on the exoskeleton porosity, the implantation site and the species. Although not osteoinductive or osteogenic, coral grafts act as an adequate carrier for growth factors and allow cell attachment, growth, spreading and differentiation. When applied appropriately and when selected to match the resorption rate with the bone formation rate of the implantation site, natural coral exoskeletons have been found to be impressive bone graft substitutes. The purpose of this article is to review and summarize all the pertinent work that has been published on natural coral as a bone graft including in vitro, animal and clinical human studies. Preliminary report of our own experiments as well as our recommendations on the use of coral are also included.

Animals↗

Bioactive coatings of endovascular stents based on polyelectrolyte multilayers.

Layer-by-layer self-assembly of two polysaccharides, hyaluronan (HA) and chitosan (CH), was employed to engineer bioactive coatings for endovascular stents. A polyethyleneimine (PEI) primer layer was adsorbed on the metallic surface to initiate the sequential adsorption of the weak polyelectrolytes. The multilayer growth was monitored using a radiolabeled HA and shown to be linear as a function of the number of layers. The chemical structure, interfacial properties, and morphology of the self-assembled multilayer were investigated by time-of-flight secondary ions mass spectrometry (ToF-SIMS), contact angle measurements, and atomic force microscopy (AFM), respectively. Multilayer-coated NiTi disks presented enhanced antifouling properties, compared to unmodified NiTi disks, as demonstrated by a decrease of platelet adhesion in an in vitro assay (38% reduction; p = 0.036). An ex vivo assay on a porcine model indicated that the coating did not prevent fouling by neutrophils. To assess whether the multilayers may be exploited as in situ drug delivery systems, the nitric-oxide-donor sodium nitroprusside (SNP) was incorporated within the multilayer. SNP-doped multilayers were shown to further reduce platelet adhesion, compared to standard multilayers (40% reduction). When NiTi wires coated with a multilayer containing a fluorescently labeled HA were placed in intimate contact with the vascular wall, the polysaccharide translocated on the porcine aortic samples, as shown by confocal microscopy observation of a treated artery. The enhanced thromboresistance of the self-assembled multilayer together with the antiinflammatory and wound healing properties of hyaluronan and chitosan are expected to reduce the neointimal hyperplasia associated with stent implantation.