Search PubMed⌕ Search

Biomedical subjects

Martyn N J Paley

Publications and source records attributed to Martyn N J Paley.

At least 19 recordsLinked to original sources

Steady-state free precession with hyperpolarized 3He: experiments and theory.

The magnetization response of hyperpolarized 3He gas to a steady-state free precession (SSFP) sequence was simulated using matrix product operators. The simulations included the effects of flip angle (alpha), sequence timings, resonant frequency, gas diffusion coefficient, imaging gradients, T1 and T2. Experiments performed at 1.5 T, on gas phantoms and with healthy human subjects, confirm the predicted theory, and indicate increased SNR with SSFP through use of higher flip angles when compared to optimized spoiled gradient echo (SPGR). Simulations and experiments show some compromise to the SNR and some point spread function broadening at high alpha due to the incomplete refocusing of transverse magnetization, caused by diffusion dephasing from the readout gradient. Mixing of gas polarization levels by diffusion between slices is also identified as a source of signal loss in SSFP at higher alpha through incomplete refocusing. Nevertheless, in the sample experiments, a SSFP sequence with an optimized flip angle of alpha=20 degrees, and 128 sequential phase encoding views, showed a higher SNR when compared to SPGR (alpha=7.2 degrees) with the same bandwidth. Some of the gas sample experiments demonstrated a transient signal response that deviates from theory in the initial phase. This was identified as being caused by radiation damping interactions between the large initial transverse magnetization and the high quality factor (Q=250) birdcage resonator. In 3He NMR experiments, performed without imaging gradients, diffusion dephasing can be mitigated, and the effective T2 is relatively long (1 s). Under these circumstances the SSFP sequence behaves like a CPMG sequence with sinalpha/2 weighting of SNR. Experiments and simulations were also performed to characterize the off-resonance behaviour of the SSFP HP 3He signal. Characteristic banding artifacts due to off-resonance harmonic beating were observed in some of the in vivo SSFP images, for instance in axial slices close to the diaphragm where B0 inhomogeneity is highest. Despite these artifacts, a higher SNR was observed with SSFP in vivo when compared to the SPGR sequence. The trends predicted by theory of increasing SSFP SNR with increasing flip angle were observed in the range alpha=10-20 degrees without compromise to image quality through blurring caused by excessive k-space filtering.

Computer Simulation↗

Imaging the fetal spine using in utero MR: diagnostic accuracy and impact on management.

BACKGROUND: In-utero MR imaging (iuMR) has entered the clinical arena during the last decade. It is used mainly for imaging fetal brain abnormalities. OBJECTIVE: To report our experience of imaging the fetal spine and spinal cord in fetuses with known or suspected abnormalities diagnosed on US imaging. MATERIALS AND METHODS: Prospective imaging and retrospective analysis of the possible impact on management of 50 consecutive fetuses with spinal abnormalities detected by antenatal US imaging. RESULTS: In 40 (80%) of 50 fetuses, iuMR and US imaging were in complete agreement. In the other 10 fetuses (20%), iuMR provided additional information or changed the diagnosis, including 8 fetuses where the iuMR could find no abnormality and was found to be correct by later follow-up. CONCLUSION: IuMR is useful in fetuses with a suspected spinal abnormality. The clinical impact of iuMR may be numerically less than with brain abnormalities, but is still sufficient to warrant its use, especially if there is any uncertainty about the US imaging, and particularly as a relatively high proportion of diagnoses on US imaging are false-positives.

Female↗

Investigation of MR signal modulation due to magnetic fields from neuronal currents in the adult human optic nerve and visual cortex.

Neuronal currents produce weak transient magnetic fields, and the hypothesis being investigated here is that the components of these parallel to the B0 field can potentially modulate the MR signal, thus providing a means of direct detection of nerve impulses. A theory for the phase and amplitude changes of the MR signal over time due to an external magnetic field has been developed to predict this modulation. Experimentally, a fast gradient-echo EPI sequence (TR = 158 ms, TE = 32.4 ms) was employed in an attempt to directly detect these neuronal currents in the adult human optic nerve and visual cortex using a 280-mm quadrature head coil at 1.5 T. A symmetrical intravoxel field distribution, which can be plausibly hypothesized for the axonal fields in the optic nerve and visual cortex, would result in phase cancellation within a voxel, and hence, only amplitude changes would be expected. On the other hand, an asymmetrical intravoxel field distribution would produce both phase and amplitude changes. The in vivo magnitude image data sets show a significant nerve firing detection rate of 56%, with zero detection using the phase image data sets. The percentage magnitude signal changes relative to the fully relaxed equilibrium signal fall within a predicted RMS field range of 1.2-2.1 nT in the optic nerve and 0.4-0.6 nT in the visual cortex, according to the hypothesis that the axonal fields create a symmetrical Lorentzian field distribution within the voxel.

Action Potentials↗

Simultaneous parallel inclined readout image technique.

Sensitivity-encoded phase undersampling has been combined with simultaneous slice excitation to produce a parallel MRI method with a high volumetric acquisition acceleration factor without the need for auxiliary stepped field coils. Dual-slice excitation was produced by modulating both spin and gradient echo sequences at +/-6 kHz. Frequency aliasing of simultaneously excited slices was prevented by using an additional gradient applied along the slice axis during data acquisition. Data were acquired using a four-channel receiver array and x4 sensitivity encoding on a 1.5 T MR system. The simultaneous parallel inclined readout image technique has been successfully demonstrated in both phantoms and volunteers. A multiplicative image acquisition acceleration factor of up to x8 was achieved. Image SNR and resolution was dependent on the ratio of the readout gradient to the additional slice gradient. A ratio of approximately 2:1 produced acceptable image quality. Use of RF pulses with additional excitation bands should enable the technique to be extended to volumetric acquisition acceleration factors in the range of x16-24 without the SNR limitations of pure partially parallel phase reduction methods.

Algorithms↗

Parallel imaging of hyperpolarized helium-3 with simultaneous slice excitation.

Hyperpolarized (HP) gas imaging of the lungs is an ideal potential application for parallel imaging. This is due to the fact that there is limited scan time (breath hold of 20 s) and limited non-renewable polarization. Reduced phase encode parallel imaging is demanding on hardware in that it requires multiple receivers. In this work, simultaneous parallel acquisition of hyperpolarized (HP) 3He images from multiple slices was demonstrated in phantoms and in vivo using a simultaneous slice excitation method, at a field strength of 1.5 T. The pulse sequence allows simultaneous acquisition of n slices per RF excitation, thus reducing the number of RF pulses needed to fully cover a given volume with multi-slicing. Unlike conventional parallel imaging, this method does not require prior reference scan information, which would consume some of the finite longitudinal polarization in lung ventilation studies with HP gas.

Artifacts↗

Investigating direct detection of axon firing in the adult human optic nerve using MRI.

The aim of this study was to directly detect spectral components of the magnetic fields of ionic currents caused by firing of the axons in the optic nerve in response to visual strobe stimulation. The magnetic field parallel to the main B0 field can potentially alter the local phase and magnitude of the MR signal which can cause signal loss due to intravoxel dephasing. Measured frequency spectra showed evidence of the strobe stimulus localized to regions containing the optic nerve, not thought to be due to motion artifacts, in 30 out of 52 experiments in 5 adult human subjects. The effect was (0.15 +/- 0.05)% of the mean magnitude equilibrium signal from the voxel in the frequency range 0.7-3.3 Hz, corresponding to an estimated field of (1.2 +/- 0.4) nT, at an echo time of TE = 32.4 ms using a 1.5 T MRI scanner. Only 1 of 12 phase image experiments showed effects. These findings provide preliminary evidence for direct detection of axonal firing in the optic nerve.

Action Potentials↗

Combined helium-3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never-smokers.

PURPOSE: To use a combination of helium-3 (3-He) magnetic resonance imaging (MRI) and proton single-shot fast spin echo (SSFSE) to compare ventilated lung volumes in groups of "healthy" smokers, smokers diagnosed with moderate chronic obstructive pulmonary disease (COPD), and never-smokers. MATERIALS AND METHODS: All study participants were assessed with spirometry prior to imaging. 3-He images were collected during an arrested breath hold, after inhaling a mixture of 200 mL of hyperpolarized 3-He/800 mL of N2. Proton SSFSE images were acquired after inhaling 1 liter of room air. The ventilated volume for each study participant was calculated from the 3-He images, and a ratio was calculated to give a percentage ventilated lung volume. RESULTS: Never-smokers exhibited a 90% mean ventilated volume. The mean ventilated lung volumes for healthy smokers and smokers diagnosed with COPD were 75.2% and 67.6%, respectively. No correlation with spirometry was demonstrated for either of the smoking groups. CONCLUSION: Combined 3-He/Proton SSFSE MRI of the lungs is a noninvasive method, using nonionizing radiation, which demonstrates ventilated airspaces and enables the calculation of ventilated lung volumes. This method appears to be sensitive to early obstructive changes in the lungs of smokers.

Adult↗

Quantitative analysis of regional airways obstruction using dynamic hyperpolarized 3He MRI-preliminary results in children with cystic fibrosis.

PURPOSE: To investigate regional airways obstruction in patients with cystic fibrosis (CF) with quantitative analysis of dynamic hyperpolarized (HP) (3)He MRI. MATERIALS AND METHODS: Dynamic radial projection MRI of HP (3)He gas was used to study respiratory dynamics in a group of eight children with CF. Signal kinetics in a total of seven regions of interest (ROIs; three in each lung, and one in the trachea) were compared with the results of spirometric pulmonary function tests (PFTs). The tracheal signal intensity was used as a form of "input function" to normalize for input flow effects. RESULTS: A pattern of low flow rate in the upper lobes was observed. When the flow measurements from the peripheral ROIs were averaged to obtain an index of flow in the peripheral lung, a good correlation was found (P = 3.74 x 10(-5)) with the forced expired volume in one second (FEV1). CONCLUSION: These results suggest that a quantitative measurement of localized airways obstruction in the early stages of CF may be obtained from dynamic (3)He MRI by using the slope of the signal rise as a measure of air flow into the peripheral lung. This study also demonstrates that children can cooperate well with the (3)He MRI technique.

Adolescent↗

3D volume-localized pO2 measurement in the human lung with 3He MRI.

A method for 3D volume-localized quantification of pO2 in the lungs is presented that uses repetitive frame 3D gradient-echo imaging of (3)He. The method was demonstrated by experiments on (3)He phantoms containing known concentrations of O(2) and in vivo on a group of three healthy human volunteers. The results were compared with those obtained by equivalent 2D thin-slice and 2D projection methodologies, and were found to be consistent with published results from the 2D projection methodologies (pO(2) = 0.09-0.18 bar). Studies performed on the same subject, on three separate occasions, demonstrated a repeatability of pO(2) measurement to within 14% using the 3D technique. Experimental differences between the 2D and 3D methods were substantiated with theoretical and numerical analyses of the signal decay, which took into account the effects of out-of-slice diffusion as a source of error in the thin-slice 2D experiments. It is shown that the 2D thin-slice technique systematically underestimates pO2 when there is significant gas diffusion (factor of 4 underestimate for D = 0.9 cm(2)s(-1) representative of free (3)He in air).

Adult↗

Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI.

INTRODUCTION: This study aims to quantify global and regional changes of diffusive motion of 3He gas within the lung, as determined by hyperpolarized 3He MR apparent diffusion coefficient (ADC) measurement, in non-smokers, smokers and chronic obstructive pulmonary disease (COPD) patients. METHODS: Age-matched groups of six healthy non-smokers, five healthy smokers and five patients with COPD. The experiments were performed with approval from the local Research Ethics Committee. Diffusion imaging was performed following hyperpolarized 3He gas inhalation, producing ADC maps. Mean and standard deviation of the ADCs were used to compare the subject groups and assess regional variations within individuals. RESULTS: The intra-individual standard deviation of ADC in the healthy smokers was significantly larger than that of the non-smoking group (P < 0.02). Compared to the non-smoking group, COPD patients had significantly higher mean and standard deviation of ADC (P < 0.01). The mean ADC in the anterior half of the chest was systematically higher than in the posterior half in the healthy non-smoking subject group. DISCUSSION: This study suggests that there are regional trends in the ADC values of healthy volunteers that may have implications for the clinical interpretation of ADC values. Less homogeneous ADC values have been detected in asymptomatic smokers, indicative of damage to the distal air spaces.

Aged↗

Measurements and modeling of long range 3He diffusion in the lung using a "slice-washout" method.

In healthy lung tissue, pulsed-gradient-spin-echo (PGSE) methods reveal apparent diffusion coefficients (ADC) of the order 0.20 cm2 s(-1); for diffusion times of approximately 2 ms. For these short diffusion times the ADC is only sensitive to structures approximately (2Dt)1/2 approximately 0.6mm in size. Recent work, using magnetic tagging of the longitudinal magnetization has revealed much smaller ADC values for longer length scales. In this work, the in vivo ADC from within the air-spaces, was measured using a new technique. The signal from a series of images was analyzed from a slice that was repeatedly imaged. Diffusion tends to "top-up" the non-renewable polarization within the slice, which leads to a non-exponential decay in image signal. Image data were compared to 1D finite-difference simulations of diffusion to calculate a long range ADC value. The results yield values of the order 0.034 cm2 s(-1), which are nearly an order of magnitude smaller than those reported by PGSE measurements at shorter diffusion times.

Algorithms↗

MRI of helium-3 gas in healthy lungs: posture related variations of alveolar size.

PURPOSE: To probe the variation of alveolar size in healthy lung tissue as a function of posture using diffusion-weighted helium-3 hyperpolarized gas imaging. MATERIALS AND METHODS: Measurements of the helium-3 apparent diffusion coefficient (ADC) were made on six healthy subjects. These were used to show the variation of alveolar size between the lowermost dependent regions of the lung compared to the uppermost regions of the lung in four postures: supine, prone, left-lateral decubitus, and right-lateral decubitus. RESULTS: The distribution of acinar size in the lungs was found to be heterogeneous, and influenced by lung orientation. In nearly all postures, the ADC was significantly higher in the non-dependent uppermost regions of the lung compared to the dependent lowermost regions of the lung; the greatest variation was found in the left-lateral decubitus position. The difference in ADC between uppermost and lowermost regions was on average 0.012 cm(2)second(-1), which represents 20% of the average ADC value for the whole lung. A systematic decrease in ADC from the apex of the lung to the base was also found, which corresponds to an inherent gradient in alveolar size. CONCLUSION: The posture dependent variations in ADC were attributed to compression of the parenchyma under its own weight and the mass of the heart.

Adult↗

Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He.

Images of hyperpolarized 3He were acquired during breath-hold in four healthy volunteers with the use of an optimized 3D gradient-echo sequence. The images were compared with existing 2D gradient-echo methods. The average SNR from a 13-mm-thick slice in the peripheral lung was 1.4 times greater with 3D. In the airways the average SNR was 1.7 times greater with 3D. The higher SNR of 3D was particularly evident when regions of unimpeded gas diffusion, such as the major airways, were imaged with thin slices. This is because diffusion dephasing due to the slice-encoding gradient is minimized with a 3D sequence. The in vivo experimental findings were substantiated with experiments on phantoms of free gas, which showed more than four times the SNR with 3D compared to 2D. Theoretical simulations of the 2D and 3D k-space filters were also performed to predict the SNR and spatial resolution observed in the experimental images.

Computer Simulation↗

Finite-difference simulations of 3He diffusion in 3D alveolar ducts: comparison with the "cylinder model".

Time-dependent measurements of 3He diffusion in the lung could provide an accurate method to quantify alveolar length scales and the progression of diseases such as emphysema. However, the apparent diffusion coefficient (ADC) presents a complex problem to model and solve analytically. Here, finite-difference methods were used to simulate diffusion in 3D alveolar ducts. The results were compared to the only available analytical model--the "cylinder model"--from which it is possible to estimate the average radii of the alveolar ducts from in vivo data. The trend in data observed from simulations was found to agree well with the cylinder model. However, the cylinder model always overestimated the average radii of the simulated alveolar ducts. The simulations also demonstrated that the measurement of the longitudinal ADC (along the alveolar ducts) should be sensitive to early emphysematous changes, whereas the measured radii should be far less sensitive.

Computer Simulation↗

Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments.

Finite difference simulations have been used to model (3)He gas diffusion in simulated lung tissue. The technique has the advantage that a wide range of structural models and diffusion-sensitizing gradient waveforms can be investigated, for which analytical methods would otherwise be virtually impossible. Results from simulations and in vivo pulsed-gradient-spin-echo (PGSE) experiments show that the apparent diffusion coefficient (ADC) is a function of diffusion time and gradient strength, and suggests diffusion is locally anisotropic. The simulations have been compared to recent work on an analytical model that characterizes lung tissue as a series of independent cylinders. The results presented may have clinical implications for (3)He ADC measurements in assessing lung diseases such as chronic-obstructive-pulmonary-disease.

Adult↗

Ultrafast magnetic resonance imaging of the neonate in a magnetic resonance-compatible incubator with a built-in coil.

BACKGROUND: Magnetic resonance (MR) imaging of the neonate is important clinically, because this group of patients often has complex and multiple problems due to prematurity and developmental abnormalities. MR imaging usually involves moving neonates away from their controlled environment to the scanner. OBJECTIVE: In this study we present the results of our initial experience with an MR-compatible incubator used on a 1.5-T system. METHODS: Seven neonates were imaged at 1.5 T without sedation or anesthesia. Images were obtained by using single-shot fast spin echo, 3-dimensional Fourier transfer gradient echo, and diffusion-weighted sequences. In 4 cases, time-of-flight angiography was performed. RESULTS: All 7 neonates were stable throughout the scan time (10-21 minutes). Experienced observers graded the images for quality, and all were graded excellent or good. In no case was the image quality poor. CONCLUSION: Neonates can be imaged safely by using an MR-compatible incubator and fast image sequences. This method should allow neonates to be imaged by MR in sites at which a dedicated neonatal MR scanner is not available.

Brain↗

B1AC-MAMBA: B1 array combined with multiple-acquisition micro B0 array parallel magnetic resonance imaging.

The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with x2 and x4 SENSE in-plane encoding using a MAMBA stepped B(0) field coil inside a four-channel phased-array coil system. Experiments were performed on a 1.5 T Infinion system (Philips Medical Systems, Cleveland, OH). The signal-to-noise ratio (SNR) was reduced with higher R factors, as was expected from the reduced number of acquisitions used to create the unaliased images. The combination of SENSE and MAMBA offers great promise for reducing scan times through parallel acquisition while at the same time reducing the number of RF channels required by a factor equal to the number of field steps employed. The B(1) array combined with MAMBA (B(1)AC-MAMBA) technique is applicable when the length of an object is much greater than its diameter, as in scanning limbs or in whole-body screening for disease.

Artifacts↗