Martin Keisch

Publications and source records attributed to Martin Keisch.

6 recordsLinked to original sources

Preliminary results and evaluation of MammoSite balloon brachytherapy for partial breast irradiation for pure ductal carcinoma in situ: a phase II clinical study.

BACKGROUND: This report presents the preliminary results and evaluation of the MammoSite balloon catheter (MammoSite Radiation Therapy System; Cytyc Corporation, Marlboro, MA) as the sole method of delivering partial breast irradiation to the lumpectomy bed with breast-conserving surgery in patients with pure ductal carcinoma in situ (DCIS). METHODS: Twelve institutions are participating in this phase II clinical study. A total of 133 patients have been enrolled and 100 patients have successfully completed the prescribed radiation therapy. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using iridium-192 high-dose rate brachytherapy. Patients who met the following criteria were selected for enrollment into the study: age 45 years or older, unicentric pure DCIS, mammographic lesion of 3 cm or less, negative margins as defined by 1 mm or more, postoperative final gross pathologic size of tumor of 5 cm or less, clinically node negative, and a postlumpectomy mammogram showing the absence of any residual suspicious microcalcifications. The placement of the MammoSite catheter was performed either at the time of the lumpectomy or postlumpectomy. The minimum distance from the balloon surface to the surface of the skin is greater than 5 mm. Data collection points are at time of enrollment, time of implant, 3 months, 6 months, and then yearly at 1- to 5-year follow-up visits. Data collected are local control rates, cosmetic outcome using the Harvard Scale, toxicities, serious adverse events, disease-free survival, cause-specific survival, and contralateral breast failure. The Van Nuys Prognostic Index scores were calculated for each patient. Local recurrence is defined as either invasive or noninvasive recurrence within the target volume. Ipsilateral elsewhere recurrence is defined as either an invasive or noninvasive recurrence occurring outside of the target volume in the previously treated breast. This recurrence is classified as a new primary tumor. RESULTS: The mean follow-up period was 9.5 months (range, 1-24 mo). The MammoSite catheter was explanted for the following reasons: inadequate skin distance (5.1%; 6 of 117), poor cavity conformance (5.1%; 6 of 117), positive margins (2.6%; 3 of 117), final histology (.85%; 1 of 117), and physician decision (.85%; 1 of 117). Of the patients in whom the MammoSite was explanted because of skin spacing or cavity conformance, 50% were at sites of new users (institutions that have placed fewer than 10 Mammosite catheters). Cosmetic results were rated as excellent in 63%, good in 35%, and fair in 2% in the 86 patients with a follow-up visit. Two patients were diagnosed with an ipsilateral local recurrence, 1 outside of the target volume and 1 true recurrence/marginal miss. One patient was diagnosed at 8 months and the other was diagnosed at 11 months. Both of these ipsilateral failures were DCIS. The Van Nuys Prognostic Index of these 2 patients was 9 and 8, respectively. Data collected showed the mean age at placement was 60.8 y, mean tumor size was 10.6 mm, mean actual closest surgical margin was 6.8 mm (range, .1-40 mm), a re-excision rate of 35%, postlumpectomy placement was 71%, and the mean skin-to-balloon surface distance was 13 mm with 89% > or =7 mm. No serious adverse events were reported. The infection rate was 4.0%. CONCLUSIONS: Accelerated partial breast irradiation delivered with the MammoSite balloon was clinically successful in patients entered into a phase II clinical study with pure DCIS, with results comparable with other studies reported in the literature that have evaluated use of the MammoSite balloon brachytherapy for delivery of radiation therapy in early breast cancers. Inadequate skin distance and poor cavity conformance were the main factors limiting the use of the MammoSite device. Cosmetic results were good to excellent in 98%. There have been 2 ipsilateral breast recurrences.

Aged↗

MammoSite.

MammoSite is a novel brachytherapy applicator for breast irradiation as a component of breast conservation therapy in the management of early stage breast carcinoma. Early stage breast cancer accounts for over two-thirds of newly diagnosed cases. Breast conservation therapy is an option for most women for local therapy. The standard treatment of partial mastectomy and whole-breast irradiation is being challenged. Physicians and patients are searching for alternatives to a 6- to 7-week course of external beam radiation therapy. The direct application of radioactive materials (brachytherapy) in this setting has been employed for over 10 years. MammoSite has been developed as an easier, more quality assured applicator to allow broader acceptance and wider availability of partial breast irradiation techniques. The background leading to the device will be examined, current clinical results will be reviewed and alternative technologies will be discussed.

Brachytherapy↗

Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy.

PURPOSE: We present the results of the initial clinical testing of the MammoSite balloon breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy. METHODS AND MATERIALS: Seventy patients were enrolled in a multicenter prospective trial testing the applicator for safety and performance. Fifty-four patients were implanted, and 43 patients were ultimately eligible for and received brachytherapy as the sole radiation modality after lumpectomy. Patients were staged T1N0M0 with negative pathologic margins and age >45 years. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using 192Ir high-dose-rate brachytherapy. A minimum skin-to-balloon surface distance of 5 mm was required for treatment. Device performance, complications, and cosmesis were assessed. RESULTS: Computed tomography imaging post-balloon inflation showed 8, 14, and 21 patients with 5-6 mm, 7-9 mm, and >10 mm of skin spacing, respectively. Two patients were explanted because of inadequate skin spacing and 7 because of suboptimal conformance of the surgical cavity to the applicator balloon. One patient was explanted because of positive nodal status and another because of age. The most common side effects related to device placement included mild erythema, drainage, pain, and echymosis. No severe side effects related to implantation, brachytherapy, or explantation occurred. Side effects related to radiation therapy were generally mild with erythema, pain, and dry desquamation being the most common. At 1 month, 88% of patients were evaluated as having good-to-excellent cosmetic results. CONCLUSIONS: The MammoSite balloon breast brachytherapy applicator performed well clinically. All eligible patients completed treatment. Side effects were mild to moderate and self-limiting. Skin-balloon surface distance and balloon-cavity conformance were the main factors limiting the initial use of the device.

Aged↗

MammoSite radiation therapy system.

The MammoSite Radiation Therapy System (RTS) has become the most widely used brachytherapy method used in the treatment of breast cancer, due to its ease of use, short learning curve, and requirement of only one interstitial path through the breast skin. The dosimetry is simple, one source position in the middle of the MammoSite balloon catheter. The data on long-term complications, however are not available, though developing. Trials for DCIS are being developed, as well as a comparison trial to standard external beam radiation as well as other forms of accelerated partial breast irradiation (APBI).

Brachytherapy↗

Applying innovations in surgical and radiation oncology to breast conservation therapy.

A paradigm shift is occurring in the radiotherapeutic management of early breast carcinoma. The current change includes technological advances in radiation therapy delivery to limit toxicity by minimizing patient treatment. These treatments include improved techniques for whole-breast irradiation, for example, hypofractionation and intensity modulated radiation therapy, and those for irradiating a smaller portion of the breast in a shorter period of time, specifically, accelerated partial breast irradiation. This article also addresses interesting research on delivering radiation therapy intraoperatively and looks ahead toward applications aimed at minimizing the physical, biological, and psychosocial impact of breast conservation therapy.

Brachytherapy↗