Search PubMed⌕ Search

Biomedical subjects

Martin Auer

Publications and source records attributed to Martin Auer.

3 recordsLinked to original sources

3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI.

Automatic computer-based methods are well suited for the image analysis of the different components in atherosclerotic plaques. Although several groups work on such analysis some of the methods used are oversimplified and require improvements when used within a computational framework for predicting meaningful stress and strain distributions in the heterogeneous arterial wall under various loading conditions. Based on high-resolution magnetic resonance imaging of excised atherosclerotic human arteries and a series of two-dimensional (2-D) contours we present a segmentation tool that permits a three-dimensional (3-D) reconstruction of the most important tissue components of atherosclerotic arteries. The underlying principle of the proposed approach is a model-based snake algorithm for identifying 2-D contours, which uses information about the plaque composition and geometric data of the tissue layers. Validation of the computer-generated tissue boundaries is performed with 100 MR images, which are compared with the results of a manual segmentation performed by four experts. Based on the Hausdorff distance and the average distance for computer-to-expert differences and the interexpert differences for the outer boundary of the adventitia, the adventitia-media, media-intima, intima-lumen and calcification boundaries are less than 1 pixel (0.234 mm). The percentage statistic shows similar results to the modified Williams index in terms of accuracy. Except for the identification of lipid-rich regions the proposed algorithm is automatic. The nonuniform rational B-spline-based computer-generated 3-D models of the individual tissue components provide a basis for clinical and computational analysis.

Algorithms↗

An automatic nonrigid registration for stained histological sections.

Automatic computer-based analyses of histological sections which are differently stained require that they are related to each other. Most registration methods are only able to perform rigid-body motion and are sensitive to noise and artifacts. Histological images, however, are accompanied by several artifacts and different contrasts, which require a nonrigid registration. In this paper, we present a hierarchical nonrigid registration algorithm able to align images, which contain minor image artifacts. The algorithm requires no a priori knowledge of the true image. The hierarchical design of the algorithm enhances robustness and accuracy, and saves computational costs. The proposed algorithm is decomposed into a fast, coarse, rigid registration step and a slower, but finer, nonrigid step. For the coarse registration, we use image pyramids, while for the second step, we combine a point-based registration with an elastic thin-plate spline interpolation. Accuracy tests, performed for 20 histological images obtained from human arteries, have shown that the error measure is acceptable, and that the image noise does not cause a problem. The associated convergence rate of the mean pixel displacement error during the rigid and nonrigid registrations is satisfying. The algorithm can be applied to various multicontrast elastic registration problems in medical imaging and may be extended to three dimensions.

Algorithms↗

Diffusion tensor imaging using single-shot SENSE-EPI.

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.

Brain↗