Search PubMed⌕ Search

Biomedical subjects

Mark S Link

Publications and source records attributed to Mark S Link.

53 records · Page 3Linked to original sources

Upper and lower limits of vulnerability to sudden arrhythmic death with chest-wall impact (commotio cordis).

OBJECTIVES: In an animal model of commotio cordis, sudden death with chest-wall impact, we sought to systematically evaluate the importance of impact velocity in the generation of ventricular fibrillation (VF) with baseball chest-wall impact. BACKGROUND: Sudden cardiac death can occur with chest-wall blows in recreational and competitive sports (commotio cordis). Analyses of clinical events suggest that the energy of impact is often not of unusual force, although this has been difficult to quantify. METHODS: Juvenile swine (8 to 25 kg) were anesthetized, placed prone in a sling to receive chest-wall strikes during the vulnerable time window during repolarization for initiation of VF with a baseball propelled at 20 to 70 mph. RESULTS: Impacts at 20 mph did not induce VF; incidence of VF increased incrementally from 7% with 25 mph impacts, to 68% with chest impact at 40 mph, and then diminished at >/=50 mph (p < 0.0001). Peak left ventricular pressure generated by the chest blow was related to the incidence of VF in a similar Gaussian relationship (p < 0.0001). CONCLUSIONS: The energy of impact is an important variable in the generation of VF with chest-wall impacts. Impacts at 40 mph were more likely to produce VF than impacts with greater or lesser velocities, suggesting that the predilection for commotio cordis is related in a complex manner to the precise velocity of chest-wall impact.

Animals↗

Herbal medicine: beneficial effects, side effects, and promising new research in the treatment of arrhythmias.

Herbal medications and dietary supplements are unregulated in the United States. The use of these medications has dramatically increased over the past decade. Many of these drugs are biologically active, yet physicians are often unaware their patients are using a traditional remedy. Physicians are frequently unfamiliar with the medications being used and the intended effect, as well as the side-effect profiles that accompany them. Recently, some of the herbal mediations that are commonly used in the general population have been shown to be beneficial for the treatment of arrhythmias. Unfortunately, many more have been shown to be detrimental. In this article, the background behind herbal medication and the degree to which herbal medications are being used is reviewed. Herbal medications known to have beneficial effects in the treatment of arrhythmias, as well as those that have known detrimental effects with regard to cardiac arrhythmias, are highlighted. Finally, research that has been done in this field, focusing on those compounds that have been shown to be biologically active in the treatment of cardiac arrhythmias, are reviewed.

Arrhythmias, Cardiac↗

Clinical results with catheter ablation: AV junction, atrial fibrillation and ventricular tachycardia.

With the limitations of pharmacologic and device therapies for atrial fibrillation and ventricular tachycardia, catheter ablation is assuming a larger role in the management of patients with these common arrhythmias. Multiple case series and clinical trials have helped to define the evolving role of these techniques for ablation of the atrioventricular node, atrial fibrillation, and ischemic ventricular tachycardia. Based on very low complication rates, excellent efficacy and proven outcomes with radiofrequency ablation of the atrioventricular node, this approach with permanent pacing should play a larger role in the treatment of symptomatic patients with permanent atrial fibrillation. While linear ablation of atrial fibrillation has limited clinical utility for the treatment of this common arrhythmia, the results of multiple case series of focal atrial fibrillation ablation indicate the potential for an expanding role of this curative technique. Catheter ablation techniques for ventricular tachycardia in the setting of coronary artery disease have a role as supplemental therapy to the implantable cardioverter defibrillator in patients with recurrent pharmacologically refractory ventricular arrhythmias requiring frequent device interventions.

Atrial Fibrillation↗

Frequent ICD shocks due to double sensing in patients with bi-ventricular implantable cardioverter defibrillators.

Biventricular pacing has emerged as a modality for treatment of patients with heart failure. Combined biventricular pacers and implantable cardioverter defibrillators offer treatment of heart failure as well as protection from sudden cardiac death. However, inappropriate ICD shocks as a result of double sensing due to widely spaced ventricular bipoles may pose a significant problem in these patients. We examined the ICD records of twenty-three patients with biventricular ICDs, and evaluated all episodes of double sensing that resulted in aborted or delivered therapy. In follow-up of 3.7 +/- 2.6 months, thirty-three shocks in fifteen episodes occurred in five patients (21.7%) due to double sensing. Four patients (17.4%) had aborted shocks due to double sensing. All episodes resulting in shock occurred because of sinus tachycardia or supraventricular tachycardia above the upper programmed pacing rate of the device with resultant AV conduction and double sensing of the nonpaced ventricular depolarization. In conclusion, double sensing of the R-wave is a common and clinically important cause of inappropriate ICD detection and shock in patients with biventricular ICDs. Appropriate programming of the ICD can prevent episodes of inappropriate shocks.

Aged↗

Use of the AutoCapture Pacing System with implantable defibrillator leads.

INTRODUCTION: Previous studies using various bipolar pacemaker leads have shown that the AutoCapture (AC) Pacing System is able to verify ventricular capture and regulate pacing output, increasing patient safety with respect to unexpected threshold changes and potentially prolonging device longevity. An increasing number of patients with implantable cardioverter defibrillators (ICDs) require ventricular pacing that contributes to a shortening of longevity of these systems. This prospective study tested the compatibility of the AC system with bipolar ICD leads. METHODS: The AC algorithm was evaluated prior to ICD testing in 30 ICD recipients. A single coil, active fixation, true bipolar ventricular lead was implanted in 21 patients, and a dual coil, passive fixation, integrated bipolar ventricular lead was implanted in 9 patients. A ventricular evoked response sensitivity test and an AC threshold test were performed using a pacemaker with the ventricular AC algorithm. RESULTS: AC was recommended in 22/30 (73.3%) of implants, including 20/21 (95.2%) with the single coil and 2/9 (22.2%) with the dual coil lead. Mean polarization was lower (1.23 +/- 0.95 mV vs 3.70 +/- 2.33 mV, P = 0.013) while the mean evoked response was higher (18.04 +/- 8.29 mV vs 10.13 +/- 4.22 mV, P = 0.002) with the single coil leads. CONCLUSION: Automatic threshold tracking using the AC is compatible with ICD leads. Leads with lower polarization and greater evoked response are more likely to result in recommendation of AC use. Use of this system offers the potential for increasing ICD generator longevity and improving patient safety in response to late unexpected threshold increases.

Aged↗

Automated external defibrillator arrhythmia detection in a model of cardiac arrest due to commotio cordis.

INTRODUCTION: Cardiac arrest due to chest wall blows (commotio cordis) has been reported with increasing frequency in children, and only about 15% of victims survive. Automated external defibrillators (AEDs) have been shown to be life saving in adults with cardiac arrest, but data on their use in children are limited. In a swine model of commotio cordis designed to be most relevant to young children, we assessed the efficacy of a commercially available AED for recognition and termination of ventricular fibrillation. METHODS AND RESULTS: Ventricular fibrillation was produced in anesthetized juvenile swine by precordial impact from a baseball under controlled conditions. Animals were randomized to defibrillation after 1, 2, 4, or 6 minutes of ventricular fibrillation. Twenty-six swine underwent 50 ventricular fibrillation inductions. Sensitivity of the AED for recognition of ventricular fibrillation was 98%, and specificity for nonshockable episodes was 100%. All episodes of ventricular fibrillation were successfully terminated by the AED. CONCLUSION: In this experimental model of commotio cordis, the AED proved to be highly sensitive and specific for recognition of ventricular fibrillation and effective in terminating the arrhythmia and restoring sinus rhythm. These findings suggest that early defibrillation with the AED could save young lives on the athletic field.

Animals↗

Testing of a new T-wave subtraction algorithm as an aid to localizing ectopic atrial beats.

BACKGROUND: Identifying the timing and morphology of an ectopic P wave from the surface electrogram can aid in the diagnosis and localization of atrial arrhythmias. Given the relatively short coupling interval of atrial ectopic beats, the P wave is often obscured by the larger amplitude QRS-T wave complex. A method to uncover such "buried" P waves using a standard 12-lead surface ECG would be clinically useful and could potentially be a noninvasive guide to catheter ablation of focal atrial tachycardia. METHODS: We developed an automated computerized program (BARD DUO LAB SYSTEM trade mark ) designed to subtract the QRS-T wave complex from the surface electrogram and uncover a previously obscured P wave. The purpose of the present study was to validate this program. The surface ECG from 21 patients undergoing atrial pacing during electrophysiologic study (group I) and 10 patients with atrial tachycardia (group II) were analyzed and the derived P-wave morphology assessed using correlation waveform analysis (CWA) and visual grading by three reviewers. RESULTS: The algorithm successfully uncovered the P wave in each surface ECG. For the 21 patients in group I, average CWA comparing the derived P wave with the previous paced P wave was 83%. Average CWA for group II was 82%. Visual grading of the match between derived P waves and paced P waves revealed a 21/21 match in group I patients and a 12/12 match in 9/10 of group II patients. CONCLUSIONS: An ectopic atrial P wave obscured by a coincident QRS-T wave complex can be accurately uncovered using this new algorithm. Addition of this technique to existing methods may improve the diagnosis of atrial arrhythmias and aid in the localization and ablation of ectopic atrial foci.

Algorithms↗

Prevalence of sensing abnormalities in dual chamber implantable cardioverter defibrillators.

BACKGROUND: The clinical efficacy of ICD therapy depends on accurate sensing of intracardiac signals and sensing algorithms. We investigated the occurrence of sensing abnormalities in patients with dual chamber ICDs. METHODS: The study group consisted of all patients with dual chamber ICDs enrolled in the LESS trial and patients implanted with dual chamber ICDs at a single center between January 1997 and July 2000. Electrograms of spontaneous ventricular arrhythmias requiring device intervention were analyzed. RESULTS: A total of 48 patients met the criteria for enrollment. Among the 244 episodes, 215 (88%) were due to ventricular tachycardia and 29 (12%) were due to ventricular fibrillation. Overall undersensing was infrequent with 12 (20%) patients exhibiting on average 2.2 undersensed beats during 26 episodes of ventricular arrhythmias. There was no delay in therapy due to undersensing. Oversensing occurred in 5 (10%) patients resulting in 13 (2.7%) episodes of inappropriate therapy. None of the patients had any lead abnormalities and oversensing resolved after device reprogramming in 4 patients while 1 patient required a separate rate sensing lead. Among patients with oversensing, 4 out of 5 were pacing before the index event while among patients with no oversensing only 5 out of 42 were pacing (P<0.001). CONCLUSIONS: Dual chamber ICDs demonstrate outstanding accuracy of sensing. However, because of the selection of patient population requiring more frequent pacing, oversensing occurs with a significant frequency. Meticulous evaluation in such patients is necessary to minimize the likelihood of oversensing and inappropriate shocks.

Aged↗

Durability of repaired sensing leads equivalent to that of new leads in implantable cardioverter defibrillator patients with sensing abnormalities.

Breaks in the insulation portions of implantable cardioverter defibrillator (ICD) leads may cause nonphysiological sensing and subsequent inappropriate ICD therapy, and may also interfere with the sensing and pacing functions of the ICD. Previously, leads with insulation breaks have been replaced with new sensing leads. However, repair of leads, utilizing a commercially available patch kit may reduce the morbidity, hospital stay, and cost of lead replacement. The long-term durability of these repairs has not previously been reported and is the subject of this study. Patients undergoing ICD sensing lead repair or replacement constituted the study population. Patients were followed at 3 month intervals with an endpoint of new lead abnormalities necessitating repeat lead repair or replacement. Twenty-five patients underwent lead repair and 27 individuals underwent lead replacement for either preoperative nonphysiological sensing (n = 25) or intraoperative evidence of insulation break (n = 27). There was no significant difference between the individuals undergoing lead repair or replacement in age (59 +/- 9 vs 60 +/- 12 years), mean left ventricular ejection fraction (40%+/- 18% vs 33%+/- 17%) or age of the lead being repaired or replaced (4.5 +/- 2.0 years vs 5.0 +/- 2.0 years). During follow-up of 44 +/- 23 months, 4 of the repaired leads and 4 of the replaced leads developed new insulation breaks requiring surgical intervention (P = 0.43). In conclusion, in nearly 4 years of follow-up of patients with sensing lead insulation breaks, there was no difference is subsequent lead survival in those with lead repair compared to those with new sensing leads inserted. The strategy of lead repair, when technically feasible, should thus be considered in all patients with sensing abnormalities secondary to insulation breaks.

Defibrillators, Implantable↗

Clinical profile and spectrum of commotio cordis.

CONTEXT: Although blunt, nonpenetrating chest blows causing sudden cardiac death (commotio cordis) are often associated with competitive sports, dangers implicit in such blows can extend into many other life activities. OBJECTIVE: To describe the comprehensive spectrum of commotio cordis events. DESIGN AND SETTING: Analysis of confirmed cases from the general community assembled in the US Commotio Cordis Registry occurring up to September 1, 2001. MAIN OUTCOME MEASURE: Commotio cordis event. RESULTS: Of 128 confirmed cases, 122 (95%) were in males and the mean (SD) age was 13.6 (8.2) years (median, 14 years; range, 3 months to 45 years); only 28 (22%) cases were aged 18 years or older. Commotio cordis events occurred most commonly during organized sporting events (79 [62%]), such as baseball, but 49 (38%) occurred as part of daily routine and recreational activities. Fatal blows were inflicted with a wide range of velocities but often occurred inadvertently and under circumstances not usually associated with risk for sudden death in informal settings near the home or playground. Twenty-two (28%) participants were wearing commercially available chest barriers, including 7 in whom the projectile made direct contact with protective padding (baseball catchers and lacrosse/hockey goalies), and 2 in whom the projectile was a baseball specifically designed to reduce risk. Only 21 (16%) individuals survived their event, with particularly prompt cardiopulmonary resuscitation/defibrillation (most commonly reversing ventricular fibrillation) the only identifiable factor associated with a favorable outcome. CONCLUSIONS: The expanded spectrum of commotio cordis illustrates the potential dangers implicit in striking the chest, regardless of the intent or force of the blow. These findings also suggest that the safety of young athletes will be enhanced by developing more effective preventive strategies (such as chest wall barriers) to achieve protection from ventricular fibrillation following precordial blows.

Adolescent↗

Inducible ventricular flutter and fibrillation predict for arrhythmia occurrence in coronary artery disease patients presenting with syncope of unknown origin.

INTRODUCTION: Ventricular fibrillation and ventricular flutter (cycle length < or = 230 msec) induced at electrophysiologic studies are thought to be nonspecific findings in patients presenting with syncope of unknown origin. However, there are limited data on the prognosis of these patients in long-term follow-up. METHODS AND RESULTS: We followed 274 consecutive patients with coronary artery disease presenting with syncope or presyncope who underwent electrophysiologic studies from January 1992 to June 1999 and assessed the risk of subsequent arrhythmias stratified by the electrophysiologic result at the time of their presentation with syncope. Ventricular fibrillation was induced in 23 patients (8%); ventricular flutter in 24 (9%), sustained ventricular tachycardia in 41 (15%); and nonsustained ventricular tachycardia 42 (15%). In 37 +/- 25 months of follow-up, there have been ventricular arrhythmias in 34 patients, including 3 (13%) of 23 who had induced ventricular fibrillation, and 7 (30%) of 24 with induced ventricular flutter, compared to 13 (32%) of 41 with sustained ventricular tachycardia, 7 (17%) of 42 with nonsustained ventricular tachycardia, and only 4 (3%) of 144 noninducible patients (P < 0.001 for induced ventricular fibrillation and ventricular flutter vs noninducible patients). The inducibility of ventricular fibrillation and ventricular flutter were independent risk factors for arrhythmia occurrence in follow-up. CONCLUSION: Ventricular fibrillation and ventricular flutter induced at electrophysiologic studies have prognostic significance for arrhythmia occurrence in patients presenting with syncope. These induced arrhythmias may not be as nonspecific as previously thought and treatment should be considered for these patients.

Aged↗

Advances in implantable cardioverter defibrillators.

Implantable cardioverter defibrillators (ICDs) have become an important therapeutic modality for patients who have had a cardiac arrest or are at risk for life-threatening ventricular arrhythmias. Clinical trials have confirmed the role of the ICD for patients with sustained ventricular arrhythmias and have expanded the indications to include patients with coronary artery disease, left ventricular dysfunction, nonsustained ventricular tachycardia, and inducible ventricular tachycardia. Numerous technologic advances in ICDs have resulted in decreased size, greater ease of placement, and increased functionality. Important advancements have been made in the effectiveness of arrhythmia classification and electrogram storage. Dual-chamber ICDs have become increasingly sophisticated with rate-adaptive sensors. Biventricular pacing is being combined with ICD function in patients with heart failure, systolic dysfunction, and QRS widening. Future advances in devices will likely lead to improved arrhythmia classification, more advanced automated features, and additional features including more sophisticated sensors and biventricular pacing systems.

Arrhythmias, Cardiac↗

Cardiac arrhythmias in the athlete: the evolving role of electrophysiology.

Arrhythmia management has undergone a revolution in the past decade. The diagnosis and treatment of arrhythmias in the athlete can be complicated by the need to compete and exercise. Some arrhythmias may be benign and asymptomatic, but others may be life threatening. Sinus bradyarrhythmias are common and even expected in athletes; these are rarely a cause for concern. Heart block is unusual and merits a thorough work-up. Atrial fibrillation may be more common in the athlete, and supraventricular tachycardias other than atrial fibrillation warrant consideration of radiofrequency ablation for cure. Ventricular arrhythmias in the athlete generally occur in the setting of structural heart disease that is genetically determined (hypertrophic cardiomyopathy, arrhythmogenic right ventricular dysplasia, anomalous coronary arteries), or acquired (coronary artery disease, myocarditis, idiopathic dilated cardiomyopathies). In these conditions the arrhythmia is life threatening. Ventricular arrhythmias that occur in the athlete without structural heart disease are not thought to be life threatening. Athletes with structural heart disease and those with exertional syncope merit a complete evaluation.

Arrhythmia, Sinus↗

Reduced risk of sudden death from chest wall blows (commotio cordis) with safety baseballs.

OBJECTIVES: In an experimental model of sudden death from baseball chest wall impact (commotio cordis), we sought to determine if sudden death by baseball impact could be reduced with safety baseballs. BACKGROUND: Sudden cardiac death can occur after chest wall impact with a baseball (commotio cordis). Whether softer-than-standard (safety) baseballs reduce the risk of sudden death is unresolved from the available human data. In a juvenile swine model, ventricular fibrillation (VF) has been shown to be induced reproducibly by precordial impact with a 30-mph baseball 10 to 30 ms before the T-wave peak, and this likelihood was reduced with the softest safety baseballs (T-balls). To further test whether safety baseballs would reduce the risk of sudden death at velocities more relevant to youth sports competition, we used our swine model of commotio cordis to test baseballs propelled at the 40-mph velocity commonly attained in that sport. METHODS: Forty animals received up to 3 chest wall impacts at 40 mph during the vulnerable period of repolarization for VF with 1 of 3 different safety baseballs of varying hardness, and also by a standard baseball. RESULTS: Safety baseballs propelled at 40 mph significantly reduced the risk for VF. The softest safety baseballs triggered VF in only 11% of impacts, compared with 19% and 22% with safety baseballs of intermediate hardness, and 69% with standard baseballs. CONCLUSION: In this experimental model of low-energy chest wall impact, safety baseballs reduced (but did not abolish) the risk of sudden cardiac death. More universal use of these safety baseballs may decrease the risk of sudden death on the playing field for young athletes.

Animals↗

Adverse cardiovascular events temporally associated with ma huang, an herbal source of ephedrine.

OBJECTIVE: To evaluate possible cardiovascular toxic effects associated with use of dietary supplements containing ma huang, an herbal source of ephedrine. METHODS: We reviewed the comprehensive database Adverse Reaction Monitoring System of the Food and Drug Administration, which included clinical records, investigative reports, and autopsy reports related to ma huang use. The main outcome measurements were stroke, myocardial infarction, and sudden death. RESULTS: From 1995 to 1997, 926 cases of possible ma huang toxicity were reported to the Food and Drug Administration. In 37 patients (23 women and 14 men with a mean +/- SD age of 43 +/- 13 years), use of ma huang was temporally related to stroke (in 16), myocardial infarction (in 10), or sudden death (in 11). Autopsies performed in 7 of the 11 patients who experienced sudden death showed a normal heart in 1, coronary atherosclerosis in 3, and cardiomyopathies in 3. In 36 of the 37 patients, use of ma huang was reported to be within the manufacturers' dosing guidelines. CONCLUSIONS: Analysis of the 37 patients indicates the following findings: (1) ma huang use is temporally related to stroke, myocardial infarction, and sudden death; (2) underlying heart or vascular disease is not a prerequisite for ma huang-related adverse events; and (3) the cardiovascular toxic effects associated with ma huang were not limited to massive doses. Although the pathogenesis of the cardiac toxic effects of ma huang remains incompletely defined, available observational and circumstantial evidence indicates that use of the substance may be associated with serious medical complications.

Adult↗

Mechanically induced sudden death in chest wall impact (commotio cordis).

Sudden death due to nonpenetrating chest wall impact in the absence of injury to the ribs, sternum and heart is known as commotio cordis. Although once thought rare, an increasing number of these events have been reported. Indeed, a significant percentage of deaths on the athletic field are due to chest wall impact. Commotio cordis is most frequently observed in young individuals (age 4-18 years), but may also occur in adults. Sudden death is instantaneous or preceded by several seconds of lightheadedness after the chest wall blow. Victims are most often found in ventricular fibrillation, and successful resuscitation is more difficult than expected given the young age, excellent health of the victims, and the absence of structural heart disease. Autopsy examination is notable for the lack of any significant cardiac or thoracic abnormalities. In an experimental model of commotio cordis utilizing anesthetized juvenile swine, ventricular fibrillation can be produced by a 30 mph baseball strike if the strike occurred during the vulnerable period of repolarization, on the upslope of the T-wave. Energy of the impact object was also found to be a critical variable with 40 mph baseballs more likely to cause ventricular fibrillation than velocities less or greater than 40 mph. In addition, more rigid impact objects and blows directly over the center of the chest were more likely to cause ventricular fibrillation. Peak left ventricular pressure generated by the chest wall blow correlated with the risk of ventricular fibrillation. Activation of the K(+)(ATP) channel is a likely cause of the ventricular fibrillation produced by chest wall blows. Successful resuscitation is attainable with early defibrillation.

Adolescent↗