Search PubMed⌕ Search

Biomedical subjects

Mark E Ladd

Publications and source records attributed to Mark E Ladd.

32 records · Page 2Linked to original sources

Impact of diet on stool signal in dark lumen magnetic resonance colonography.

PURPOSE: To examine the magnetic resonance (MR) properties of different foods and their effect on the colonic stool signal to potentially support fecal tagging strategies for dark lumen MR colonography (MRC). MATERIALS AND METHODS: T1 relaxation times of 120 different foods (partially diluted with sufficient water) were determined by use of a multi-flip-angle two-dimensional gradient echo (GRE) sequence and correlated to the foods' signal in a three-dimensional GRE volumetric interpolated breath-hold examination (VIBE) sequence. Different dilutions of six foods were examined. VIBE stool signal was determined in six volunteers under two different conditions: after a three-day diet of short T1 food and of long T1 food, respectively. RESULTS: Most foods exhibit short to very short T1 relaxation times. T1 correlates well with the fat-saturated VIBE signal except for fatty products. Diluted food exhibits T1 times similar to water; concentrated food strongly varies according to their T1 values. No significant difference in stool signal could be found in the in vivo examination comparing the two diets. CONCLUSION: According to our results, a restricted diet strategy to reduce fecal signal for dark lumen MRC is unlikely to be successful. Moreover, the stool signal reduction found in the other fecal tagging studies can be explained at least to a great extent by the relative content of other material with long T1 relaxation times, such as water or oral barium.

Colon↗

Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: comparison of image quality and artifacts.

PURPOSE: To compare image quality, artifacts, and signal-to-noise ratio (SNR) in cardiac cine TrueFISP magnetic resonance imaging (MRI) with and without parallel acquisition techniques (PAT). MATERIALS AND METHODS: MRI was performed in 16 subjects with a TrueFISP sequence (1.5 T; Magnetom Sonata, Siemens): TR, 3.0 msec; TE, 1.5 msec; flip angle (FA), 60 degrees. Three axes were scanned without PAT (no PAT) and using the generalized autocalibrating partially parallel acquisition (GRAPPA) and modified sensitivity encoding (mSENSE) reconstruction algorithms with an autocalibration mode to reduce scan time. A conventional spine array and a body flex array were used. Artifacts, image noise, and overall image quality were classified on a 4-point scale by an observer blinded to the implemented technique; for quantitative comparison, SNR was measured. RESULTS: With a PAT factor of two, acquisition time could be reduced by 39%. No PAT did not show artifacts, and GRAPPA revealed fewer artifacts than mSENSE. PAT provided inferior-quality scores concerning image noise and overall image quality. In quantitative measurements, GRAPPA and mSENSE (20.1 +/- 6.2 and 15.6 +/- 6.2, respectively) yielded lower SNR than no PAT (30.6 +/- 20.1; P < 0.05) and P < 0.001). CONCLUSION: Time savings in PAT are accompanied by artifacts and an increase in image noise. The GRAPPA algorithm was superior to mSENSE concerning image quality, noise, and SNR.

Adult↗

In vivo elasticity measurements of extremity skeletal muscle with MR elastography.

MR elastography (MRE) has been shown to be capable of non-invasively measuring tissue elasticity even in deep-lying regions. Although limited studies have already been published examining in vivo muscle elasticity, it is still not clear over what range the in vivo elasticity values vary. The present study intends to produce further information by examining four different skeletal muscles in a group of 12 healthy volunteers in the age range of 27-38 years. The examinations were performed in the biceps brachii, the flexor digitorum profundus, the soleus and the gastrocnemius. The average shear modulus was determined to be 17.9 (+/- 5.5), 8.7 (+/- 2.8), 12.5 (+/- 7.3) and 9.9 (+/- 6.8) kPa for each muscle, respectively. To ascertain the reproducibility of the examination, the stiffness measurements in two volunteers were repeated seven times for the biceps brachii. These examinations yielded a mean shear modulus of 11.3 +/-.7 and 13.3 +/- 4.7 kPa for the two subjects. For elasticity reconstruction, an automated reconstruction algorithm is introduced which eliminates variation due to subjective manual image analysis. This study yields new information regarding the expected variation in muscle elasticity in a healthy population, and also reveals the expected variability of the MRE technique in skeletal muscle.

Adult↗

Diffusive sensitivity to muscle architecture: a magnetic resonance diffusion tensor imaging study of the human calf.

The aim of this study was to examine the diffusive properties of adjacent muscles at rest, and to determine the relationship between diffusive and architectural properties, which are task-specific to muscles. The principle, second, and third eigenvalues, trace of the diffusion tensor, and two anisotropic parameters, ellipsoid eccentricity (e) and fractional anisotropy (FA), of various muscles in the human calf were calculated by diffusion tensor imaging (DTI). Linear correlations of the calculated parameters to the muscle physiological cross-sectional area (PCSA), which is proportional to maximum muscle force, were performed to ascertain any linear relation between muscle architecture and diffusivity. Images of the left calf were acquired from six healthy male volunteers. Seven muscles were investigated in this study. These comprised the soleus, lateral gastrocnemius, medial gastrocnemius, posterior tibialis, anterior tibialis, extensor digitorum longus, and peroneus longus. All data were presented as the mean and standard error of the mean (SEM). In general, differences in diffusive parameter values occurred primarily between functionally different muscles. A strong correlation was also found between PCSA and the third eigenvalue, e, and FA. A mathematical derivation revealed a linear relationship between PCSA and the third eigenvalue as a result of their dependence on the average radius of all fibers within a single muscle. These findings demonstrated the ability of DTI to differentiate between functionally different muscles in the same region of the body on the basis of their diffusive properties.

Diffusion Magnetic Resonance Imaging↗

Albumin targeting of damaged muscle fibres in the mdx mouse can be monitored by MRI.

Increased sarcolemmal permeability has been implicated as a major pathological event in muscular dystrophies. In our study, we evaluated whether damaged muscle fibres can be specifically targeted using albumin as a carrier. We tagged human serum albumin (HSA) with Gadolinium (Gd) and systemically applied this compound (Gd-DTPA-HSA) to wildtype and dystrophin-deficient mdx mice. We performed magnetic resonance imaging before and after intravenous administration of Gd-DTPA-HSA and found localised signal enhancement only in mdx skeletal muscle. We also examined skeletal muscle after contrast enhanced magnetic resonance imaging using anti-human albumin antibodies and demonstrated intracellular accumulation of Gd-DTPA-HSA in clusters of damaged mdx muscle fibres. Comparison of magnetic resonance imaging and histological data emphasised the value of contrast agent enhanced magnetic resonance imaging for the in vivo assessment of fibre damage in muscular dystrophies. Furthermore, our data provide evidence that albumin can be used as a carrier to target covalently bound molecules to degenerating muscle fibres.

Animals↗

Interventional MR angiography with a floating table.

A floating table was integrated into a setup for performance of interventional magnetic resonance (MR) angiography procedures with actively visualized catheters and biplanar real-time image fusion. The setup was evaluated by performing catheterizations in eight pigs. The floating table enabled the authors to follow actively visualized instruments in the pigs' vasculature during MR imaging-guided interventional angiography procedures while performing real-time biplanar MR imaging. Interventional MR angiography with a floating table enables the field of view to be moved along with the instrument tip to the region of interest and thus enhances the usability and flexibility of the interventional MR imaging setup.

Animals↗

Sparse imaging of the auditory oddball task with functional MRI.

Cortical reactions to rare task-related stimuli have been studied with electrophysiological methods in the assessment of the P300 component as well as in functional imaging studies with regard to oddball tasks. While functional magnetic resonance imaging studies using auditory stimuli have to deal with interference between auditory stimuli and scanner noise, the aim of our study was to assess auditory target processing with the sparse imaging method. Single volumes of echo-planar imaging were acquired 4 s following the onset of the stimuli of interest. In keeping with previous studies, target stimuli activated the insula, superior temporal gyrus, cingulate gyrus, middle frontal gyrus, parietal cortex and the cerebellum. Our results encourage the application of the sparse imaging method in experiments on cognitive processing elicited by auditory stimulation in a silent environment.

Acoustic Stimulation↗

Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion.

An integrated system for performing interventional magnetic resonance angiography (MRA) with actively visualized instruments and real-time image fusion was implemented on a 1.5 T scanner. True fast imaging with steady precession (TrueFISP) imaging provided high acquisition speed paired with high signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the simultaneous visualization of active instruments and arterial morphology. The system enabled simultaneous image reconstruction and image postprocessing of multiple receiver channels, with subsequent image fusion display in real time. Optional interleaved image acquisition in two planes provided additional important information for biplanar instrument guidance. Various vascular interventions, including selective catheterization and subsequent selective MRA of the abdominal aorta, renal arteries, superior mesenteric artery (SMA), hepatic artery, and aortic arch, were performed on 10 pigs under MR guidance. In terms of instrument contrast, image acquisition, reconstruction, and fusion speed, the setup represents a powerful platform for performing interventional MRA procedures.

Animals↗

[Interventional MRA: concepts for active visualization of catheters and stents].

A precondition to safe guidance of vascular guidewires and catheters during the course of magnetic resonance (MR)-guided vascular intervention is a high-contrast visualization of the instruments. The integration of miniature radiofrequency (RF) coils and coaxial cables into guidewires and catheters enables the reception of RF signal from the lumen of blood vessels, and thus the active visualization of the instruments. Moreover, metallic vascular implants (stents) can be modified to act as intravascular RF antennas that inductively couple their RF signal to a conventional surface RF coil. Such stent resonators show signal amplification inside the lumen of the stent and thus can be visualized with high contrast in MR images. Furthermore, once such a device has been implanted, the method offers the potential for non-invasive long-term follow-up of the stent patency.

Animals↗

Real-time MRI of joint movement with trueFISP.

PURPOSE: To develop a technique for dynamic magnetic resonance imaging (MRI) of joint motion based on a combination of real-time TrueFISP (fast imaging with steady state precession) imaging with surface radiofrequency (RF) coils. MATERIALS AND METHODS: The metacarpal, elbow, tarsal, and knee joint of five volunteers and the knees of four patients were examined with a real-time TrueFISP sequence during movement of the joints. RESULTS: All examined joints could be assessed under dynamic conditions with high image contrast and high temporal resolution. CONCLUSION: Dynamic MRI of joints with TrueFISP is feasible and can provide information supplemental to static joint examinations.

Elbow Joint↗

Inductively coupled stent antennas in MRI.

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis.

Animals↗

Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience.

A technique for performing whole-body magnetic resonance (MR) angiography with multi-station three-dimensional MR angiography by using a self-developed rolling table platform that integrates the surface coil was evaluated in three volunteers and 10 patients. Use of the surface coil resulted in high signal-to-noise and contrast-to-noise ratios, which translated into sensitivity and specificity of 95.3% and 95.2%, respectively, for detection of significant stenoses (luminal narrowing, >50%) in lower extremity peripheral vascular disease.

Adult↗

Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR imaging.

OBJECTIVE: The aim of our study was to evaluate whether a recently developed real-time steady-state free precession (trueFISP) cine sequence could be used to assess left ventricular function in a single breath-hold. CONCLUSION: Using real-time trueFISP permits one to assess left ventricular function in a single breath-hold. The dramatic reduction in data acquisition time does require some compromises. The temporal and spatial resolutions of images obtained with real-time trueFISP were considerably lower than those achieved with segmented trueFISP. Further reduction of the TR or the use of sensitivity encoding could improve temporal resolution and eliminate other limitations of real-time trueFISP.

Adult↗

MR imaging of the vessel wall.

Since the risks for thrombosis are more dependent on plaque composition than on the degree of luminal narrowing, the radiological assessment of atherosclerosis should extend beyond mere depiction of the arterial lumen. High-resolution MRI of the vessel wall can provide important information about the individual makeup of atherosclerotic plaques, potentially enabling early detection and characterization of lesions before narrowing of the vessel lumen occurs. The MR-based assessment of the vessel wall with sufficient spatial resolution and image contrast, however, remains challenging. Requirements include high signal-to-noise ratio, high contrast-to-noise ratio, good signal penetration depth and homogeneous signal throughout the vessel under investigation, as well as imaging protocols encompassing various contrast weightings. Numerous dedicated radiofrequency (RF) coils have been developed to achieve these goals employing either external surface phased-array coils, or alternatively, utilizing intravascular coils to image the vessel wall from inside the vessel and thus being invasive. For the non-invasive approach of imaging with surface coils, the carotid and the right coronary arteries have been favoured since they are of critical importance and since they are relatively superficial structures, accessible from the outside. To detect the early development of plaque and visualize it globally rather than locally, intravascular contrast agents on the basis of ultrasmall particles of iron oxide can be used as a marker of macrophage activity within the plaque. In the long run, it appears likely that the combination of luminal MR angiography with the administration of susceptibility-based contrast agents and subsequent high-resolution MR of detected atherosclerotic lesions with dedicated RF coils could evolve as the diagnostic concept of choice for the assessment of atherosclerotic disease.

Arteriosclerosis↗