Search PubMed⌕ Search

Biomedical subjects

Mark A Haidekker

Publications and source records attributed to Mark A Haidekker.

6 recordsLinked to original sources

Extracellular signal-regulated kinase activation and endothelin-1 production in human endothelial cells exposed to vibration.

Hand-arm vibration syndrome is a vascular disease of occupational origin and a form of secondary Raynaud's phenomenon. Chronic exposure to hand-held vibrating tools may cause endothelial injury. This study investigates the biomechanical forces involved in the transduction of fluid vibration in the endothelium. Human endothelial cells were exposed to direct vibration and rapid low-volume fluid oscillation. Rapid low-volume fluid oscillation was used to simulate the effects of vibration by generating defined temporal gradients in fluid shear stress across an endothelial monolayer. Extracellular signal-regulated kinase (ERK1/2) phosphorylation and endothelin-1 (ET-1) release were monitored as specific biochemical markers for temporal gradients and endothelial response, respectively. Both vibrational methods were found to phosphorylate ERK1/2 in a similar pattern. At a fixed frequency of fluid oscillation where the duration of each pulse cycle remained constant, ERK1/2 phosphorylation increased with the increasing magnitude of the applied temporal gradient. However, when the frequency of flow oscillation was increased (thus decreasing the duration of each pulse cycle), ERK1/2 phosphorylation was attenuated across all temporal gradient flow profiles. Fluid oscillation significantly stimulated ET-1 release compared to steady flow, and endothelin-1 was also attenuated with the increase in oscillation frequency. Taken together, these results show that both the absolute magnitude of the temporal gradient and the frequency/duration of each pulse cycle play a role in the biomechanical transduction of fluid vibrational forces in endothelial cells. Furthermore, this study reports for the first time a link between the ERK1/2 signal transduction pathway and transmission of vibrational forces in the endothelium.

Blotting, Western↗

Hydrophilic molecular rotor derivatives-synthesis and characterization.

Recent research shows high potential for some p-N,N-dialkylaminobenzylidenecyanoacetates, part of a group known as fluorescent molecular rotors, to serve as fluorescent, non-mechanical viscosity sensors. Of particular interest are molecules compatible with aqueous environments. In this study, we present the synthesis and physical characterization of derivatives from 9-(2-carboxy-2-cyanovinyl)-julolidine and related molecules. All compounds show a power-law relationship of fluorescence emission with the viscosity of the solvent, different mixtures of ethylene glycol and glycerol to modulate viscosity. Compounds with high water solubility exhibit the same behavior in aqueous solutions of dextran, where the dextran concentration was varied to modulate viscosity. In addition, some compounds have been found to have low sensitivity towards changes in the pH in the physiological range. The compounds presented show promise to be used in biofluids, such as blood plasma or lymphatic fluid, to rapidly and non-mechanically determine viscosity.

Acetates↗

Computerized methods for X-ray-based small bone densitometry.

Animal models have been widely used to correlate in vivo changes in bone mineral density (BMD) with changes in disease state of bone. In small animal models, e.g. the hindlimb suspension model of bone loss, a non-invasive assessment of BMD is required. X-ray radiography has been surpassed in some cases by quantitative computed tomography (QCT) and dual X-ray absorptiometry (DEXA) quantitation. However, there are drawbacks in using the computerized methods, especially for small animals. In this paper, we present image-processing algorithms to quantitatively determine bone area and mineral density in digitized radiographs. Image calibration is based on a calibration step wedge, and the algorithm automatically detects the steps and computes the calibration data. In addition, we demonstrate how the algorithm can accurately determine the cortical outline of the bone and provide reliable data and statistics for small animal studies. A downloadable implementation example for the popular NIH Image package is provided.

Absorptiometry, Photon↗

Cell membrane fluidity changes and membrane undulations observed using a laser scattering technique.

Local transversal micromotions of cell membranes have been reported. These may provide the physical basis for changes in membrane fluidity. In this study, tissue scattering properties are used to measure the magnitude of transversal micromotions under varying stimuli. Laser light is directed at the cell surface at a low incident angle of 12 degrees so that reflected or refracted light does not enter the microscope objective. Scattered light showed strong low-frequency intensity fluctuations with random-walk behavior. Fluctuations were quantified by the median coefficient of variation over the entire observed cell area. Incubation of the cells with protein crosslinkers (paraformaldehyde) and metabolic suppressors (sodium azide) suppressed these fluctuations by 62 and 44%, respectively. The application of hypoosmotic media caused an increase of fluctuation magnitude by 23% (p < 0.005). Agents that increase membrane fluidity (2% ethanol and xenon) increased fluctuation magnitude by 15 and 31%, respectively (p < 0.05). Cessation of the ethanol and xenon exposure led to partial recovery of the fluctuation magnitude, which was nonsignificant for ethanol. This study shows a strong link between membrane fluidity and transversal membrane undulations and provides an important step in the understanding of the mechanosensing function of the cell membrane.

Cell Line, Tumor↗

Phospholipid-bound molecular rotors: synthesis and characterization.

Molecular rotors are fluorescent molecules with a viscosity-sensitive quantum yield that are often used to measure viscosity changes in cell membranes and liposomes. However, commercially available molecular rotors, such as DCVJ (1) do not localize in cell membranes but rapidly migrate into the cytoplasm leading to unreliable measurements of cell membrane viscosity. To overcome this problem, we synthesized molecular rotors covalently attached to a phospholipid scaffold. Attaching the rotor group to the hydrophobic end of phosphatidylcholine (PC) did not affect the rotor's viscosity sensitivity and allowed adequate integration into artificial bilayers as well as complete localization in the plasma membrane of an endothelial cell line. Moreover, these new rotors enabled the monitoring of phospholipid transition temperature. However, attachment of the rotor groups to the hydrophilic head of the phospholipid led to a partial loss of viscosity sensitivity. The improved sensitivity and exclusive localization in the cell plasma membrane exhibited by the phospholipid-bound molecular rotors suggest that these probes can be used for the study of membrane microviscosity.

Cell Line↗

A novel approach to blood plasma viscosity measurement using fluorescent molecular rotors.

Molecular rotors, a group of fluorescent molecules with viscosity-dependent quantum yield, were tested for their suitability to act as fluorescence-based plasma viscometers. The viscosity of samples of human plasma was modified by the addition of pentastarch (molecular mass 260 kDa, 10% solution in saline) and measured with a Brookfield viscometer. Plasma viscosity was 1.6 mPa x s, and the mixtures ranged up to 4.5 mPa x s (21 degrees C). The stimulated light emission of the molecular rotors mixed in the plasma samples yielded light intensity that was nonoverlapping and of significantly different intensity for viscosity steps down to 0.3 mPa x s (n = 5, P < 0.0001). The mathematical relationship between intensity (I) and viscosity (eta) was found to be eta = (kappaI)(nu). After calibration and scaling the fluorescence based measurement had an average deviation versus the conventional viscometric measurements that was <1.8%. These results show the suitability of molecular rotors for fast, low-volume biofluid viscosity measurements achieving accuracy and precision comparable to mechanical viscometers.

Blood Viscosity↗