Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra.

Partial least-squares (PLS) calibration models have been generated from a series of near-infrared (near-IR) and Raman spectra acquired separately from sixty different mixed solutions of glucose, lactate, and urea in aqueous phosphate buffer. Independent PLS models were prepared and compared for glucose, lactate, and urea. Near-IR and Raman spectral features differed substantially for these solutes, with Raman spectra enabling greater distinction with less spectral overlap than features in the near-IR spectra. Despite this, PLS models derived from near-IR spectra outperformed those from Raman spectra. Standard errors of prediction were 0.24, 0.11, and 0.14 mmol L(-1) for glucose, lactate, and urea, respectively, from near-IR spectra and 0.40, 0.42, and 0.36 mmol L(-1) for glucose, lactate, and urea, respectively, from Raman spectra. Differences between instrumental signal-to-noise ratios were responsible for the better performance of the near-IR models. The chemical basis of model selectivity was examined for each model by using a pure component selectivity analysis combined with analysis of the net analyte signal for each solute. This selectivity analysis showed that models based on either near-IR or Raman spectra had excellent selectivity for the targeted analyte. The net analyte signal analysis also revealed that analytical sensitivity was higher for the models generated from near-IR spectra. This is consistent with the lower standard errors of prediction.

Calibration↗

In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels.

We have performed in vivo measurements of near-infrared rat skin absorption in the 4000-5000-cm(-1) spectral range (2.0-2.5-microm wavelength) during a glucose clamp experiment in order to identify the presence of glucose-specific spectral information. Spectra were collected during an initial 3-h period where the animal's blood glucose concentration was held at its normal value. The blood glucose level was then increased above 30 mM by venous infusion of glucose and held for 2 h, after which it was allowed to return to normal. Spectra were recorded continuously during the procedure and are analyzed to identify spectral changes associated with changes in glucose concentration. Because the change in absorbance due to an increase in glucose concentration is small compared to changes due to other variations (e.g., the thickness of the skin sample), a simple subtraction of absorbance spectra from the hyperglycemic and euglycemic phases is not instructive. Instead, a set of principal components is established from the euglycemic period where the glucose concentration is constant. We then examine the change in absorbance during the hyperglycemic period that is orthogonal to these principal components. We find that there are significant similarities between these orthogonal variations and the net analyte signal of glucose, which suggests that glucose spectral information is present. The analysis described here provides a procedure by which the analytical significance of a multivariate calibration can be evaluated.

Animals↗

Noninvasive glucose sensing.

The ability to measure glucose noninvasively in human subjects is a major objective for many research groups. Success will revolutionize the treatment of diabetes by providing a means to improve glycemic control, thereby delaying the onset of the medical complications associated with this disease. This article focuses on the current state of the art and attempts to identify the principal areas of research necessary to advance the field. Two fundamentally different approaches are identified for the development of noninvasive glucose sensing technology. The indirect approach attempts to measure glucose on the basis of its effect on a secondary process. The direct approach is based on the unique chemical structure of the glucose molecule. Advances for each approach are limited by issues of selectivity. Several critical parameters are discussed for the direct approach, including issues related to the optical path length, wavelength range, dimensionality of the multivariate calibration model, net analyte signal, spectral variance, and assessment of the chemical basis of measurement selectivity. A set of publication standards is recommended as a means to enhance progress toward a successful noninvasive monitor.

Animals↗

Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy.

Optical properties of whole bovine blood are examined under conditions of different glucose loadings. A strong dependency is established between the scattering properties of the whole blood matrix and the concentration of glucose. This dependency is explained in terms of variations in the refractive index mismatch between the scattering bodies (predominately red blood cells) and the surrounding plasma. Measurements in the presence of a well-known glucose transport inhibitor indicate that variations in refractive index mismatch are related to the penetration of glucose into the red blood cells and demonstrate that increased scattering involves the uptake of glucose by red blood cells. Finally, multivariate calibration models are presented for the measurement of glucose in a whole blood matrix. These models are based on near-infrared spectral data collected from 80 different samples prepared from a single whole blood matrix. Calibration studies are performed over the combination, first-overtone, and short-wavelength spectral regions. The best calibration model is generated from combination region spectra, providing a standard error of prediction (SEP) of less than 1 mM over the concentration range of 3-30 mM. The model based on the first-overtone region is slightly degraded but still provides acceptable performance (SEP = 1.20 mM). The model based on the short-wavelength region is further degraded (SEP = 2.53 mM). To rationalize these results, an analysis of the selectivity of the calibration models is performed by computing the glucose net analyte signal. It is established that the models based on the combination and first-overtone regions are dominated by glucose absorption information, while the model computed from the short-wavelength region is based primarily on scattering information. This result provides evidence that absorption information is needed in order to obtain a glucose calibration model with acceptable performance.

Animals↗

Tunable laser diode system for noninvasive blood glucose measurements.

Optical sensing of glucose would allow more frequent monitoring and tighter glucose control for people with diabetes. The key to a successful optical noninvasive measurement of glucose is the collection of an optical spectrum with a very high signal-to-noise ratio in a spectral region with significant glucose absorption. Unfortunately, the optical throughput of skin is low due to absorption and scattering. To overcome these difficulties, we have developed a high-brightness tunable laser system for measurements in the 2.0-2.5 microm wavelength range. The system is based on a 2.3 microm wavelength, strained quantum-well laser diode incorporating GaInAsSb wells and AlGaAsSb barrier and cladding layers. Wavelength control is provided by coupling the laser diode to an external cavity that includes an acousto-optic tunable filter. Tuning ranges of greater than 110 nm have been obtained. Because the tunable filter has no moving parts, scans can be completed very quickly, typically in less than 10 ms. We describe the performance of the present laser system and avenues for extending the tuning range beyond 400 nm.

Blood Glucose↗

Comparison of combination and first overtone spectral regions for near-infrared calibration models for glucose and other biomolecules in aqueous solutions.

Partial least squares calibration models are compared for the measurement of glucose, lactate, urea, ascorbate, triacetin, and alanine in aqueous solutions from single-beam spectra collected over the first overtone (6500-5500 cm(-1)) and the combination (5000-4000 cm(-1)) regions of the near-infrared spectrum. Spectra are collected under two sets of conditions with one designed for combination spectra and the other designed for first overtone spectra. As part of the optimization of conditions, an exponential function is presented that accurately characterizes the strong dependency between spectral quality and sample thickness. Sample thickness set for the first overtone and combination spectra are 7.5 and 1.5 mm, respectively. Independent calibration models are established for each solute from both combination and first overtone spectra. Direct comparison reveals superior performance by models generated from combination spectra, particularly for glucose and urea. Standard error of prediction (SEP) values are 1.12 and 0.45 mM for glucose models generated from first overtone and combination spectra, respectively. SEP values for urea are 7.33 and 0.10 mM for first overtone and combination spectra, respectively. Such high SEP values for urea with first overtone spectra correspond to an inability to quantify urea from these spectra because of a lack urea-specific molecular absorption features in this spectral region. Net analyte signal (NAS) is used to quantify the degree of selectivity provided within the first overtone and combination spectral regions. The superior selectivity of combination spectra is confirmed by comparing the length of the NAS vectors for each matrix component.

Calibration↗

On-line monitoring of human prostate cancer cells in a perfusion rotating wall vessel by near-infrared spectroscopy.

PC-3 human prostate cancer cells have been cultivated in a rotating wall vessel in which glucose, lactate, and glutamine profiles were monitored noninvasively and in real time by near-infrared (NIR) spectroscopy. The calibration models were based on off-line spectra from tissue culture experiments described previously (Rhiel et al., Biotechnol Bioeng 77:73-82). Monitoring performance was improved by Fourier filtering of the spectra and initial off-set adjustment. The resulting standard errors of predictions were 0.95, 0.74, and 0.39 mM for glucose, lactate, and glutamine, respectively. The concentration of ammonia could not be accurately measured from the same spectra. In addition, metabolite uptake and production rates were determined for PC-3 prostate cancer cells during exponential growth in batch-mode cultivation. Cells grew with a doubling time of 21 h and consumed glucose and glutamine at rates of 6.8 and 1.8 x 10(-17) mol/cell.s, respectively. This resulted in lactate and ammonia production rates of 11.9 and 1.3 x 10(-17) mol/cell.s, respectively. Compared with other monitoring technologies, this technology has many advantages for spaceflights and stand-alone units; for instance, calibration can be performed at one time and then applied in a reagentless, low-maintenance way at a later time. The resulting concentration information can be incorporated into closed-loop control schemes, thereby leading to better in vitro models of in vivo behavior.

Ammonia↗

Pure component selectivity analysis of multivariate calibration models from near-infrared spectra.

A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-)(1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.

Calibration↗

Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared spectrum.

Molar absorptivities are measured for water, glucose, alanine, ascorbate, lactate, triacetin, and urea in the near-infrared spectral region at 37 degrees C. Values are based on the Beer-Lambert law and cover the first overtone (1550-1850 nm; 6450-5400 cm(-1)) and combination (2000-2500 nm; 4000-5000 cm(-1)) spectral windows through aqueous media. Accurate calculations demand accounting for the impact of water displacement upon dissolution of solute. In this regard, water displacement coefficients are measured and reported for each solute. First overtone absorptivities range from 2 to 7 x 10(-5) mM(-1)mm(-1) for all solutes except urea, for which absorptivity values are below 0.5 x 10(-5) mM(-1) mm(-1) across this spectral range. Molar absorptivities over the combination spectral region range from 0.8 to 3.2 x 10(-4) mM(-1) mm(-1), which is a factor of four to five greater than the first overtone absorptivities. Accuracy of the measured values is assessed by comparing calculated or modeled spectra with spectra measured from standard solutions. This comparison reveals accurately modeled spectra in terms of magnitude and position of solute absorption bands. Both actual and modeled spectra from glucose solutions reveal positive and negative absorbance values depending on the measurement wavelength. It is shown that the net absorbance of light is controlled by the magnitude of the absorptivity of glucose compared to the product of the absorptivity of water and the water displacement coefficient for glucose.

Glucose↗

Online measurement of urea concentration in spent dialysate during hemodialysis.

BACKGROUND: We describe online optical measurements of urea in the effluent dialysate line during regular hemodialysis treatment of several patients. Monitoring urea removal can provide valuable information about dialysis efficiency. METHODS: Spectral measurements were performed with a Fourier-transform infrared spectrometer equipped with a flow-through cell. Spectra were recorded across the 5000-4000 cm(-1) (2.0-2.5 microm) wavelength range at 1-min intervals. Savitzky-Golay filtering was used to remove baseline variations attributable to the temperature dependence of the water absorption spectrum. Urea concentrations were extracted from the filtered spectra by use of partial least-squares regression and the net analyte signal of urea. RESULTS: Urea concentrations predicted by partial least-squares regression matched concentrations obtained from standard chemical assays with a root mean square error of 0.30 mmol/L (0.84 mg/dL urea nitrogen) over an observed concentration range of 0-11 mmol/L. The root mean square error obtained with the net analyte signal of urea was 0.43 mmol/L with a calibration based only on a set of pure-component spectra. The error decreased to 0.23 mmol/L when a slope and offset correction were used. CONCLUSIONS: Urea concentrations can be continuously monitored during hemodialysis by near-infrared spectroscopy. Calibrations based on the net analyte signal of urea are particularly appealing because they do not require a training step, as do statistical multivariate calibration procedures such as partial least-squares regression.

Calibration↗

Multivariate calibration standardization across instruments for the determination of glucose by Fourier transform near-infrared spectrometry.

The transfer of multivariate calibration models is investigated between a primary (A) and two secondary Fourier transform near-infrared (near-IR) spectrometers (B, C). The application studied in this work is the use of bands in the near-IR combination region of 5000-4000 cm(-)(1) to determine physiological levels of glucose in a buffered aqueous matrix containing varying levels of alanine, ascorbate, lactate, triacetin, and urea. The three spectrometers are used to measure 80 samples produced through a randomized experimental design that minimizes correlations between the component concentrations and between the concentrations of glucose and water. Direct standardization (DS), piecewise direct standardization (PDS), and guided model reoptimization (GMR) are evaluated for use in transferring partial least-squares calibration models developed with the spectra of 64 samples from the primary instrument to the prediction of glucose concentrations in 16 prediction samples measured with each secondary spectrometer. The three algorithms are evaluated as a function of the number of standardization samples used in transferring the calibration models. Performance criteria for judging the success of the calibration transfer are established as the standard error of prediction (SEP) for internal calibration models built with the spectra of the 64 calibration samples collected with each secondary spectrometer. These SEP values are 1.51 and 1.14 mM for spectrometers B and C, respectively. When calibration standardization is applied, the GMR algorithm is observed to outperform DS and PDS. With spectrometer C, the calibration transfer is highly successful, producing an SEP value of 1.07 mM. However, an SEP of 2.96 mM indicates unsuccessful calibration standardization with spectrometer B. This failure is attributed to differences in the variance structure of the spectra collected with spectrometers A and B. Diagnostic procedures are presented for use with the GMR algorithm that forecasts the successful calibration transfer with spectrometer C and the unsatisfactory results with spectrometer B.

Algorithms↗

Near-infrared spectroscopic measurement of urea in dialysate samples collected during hemodialysis treatments.

Single-beam spectra were collected over the combination region of the near-infrared spectrum for 80 samples collected from 15 people over a two-week period. Partial least-squares (PLS) regression was used to generate an optimized calibration model for urea. PLS calibration models accurately measure urea in the spent dialysate matrix. Prediction errors are on the order of 0.15 mM, which is sufficient for the clinical assessment of the dialysis process. In addition, the feasibility of a global calibration model is demonstrated by generating a calibration model from samples and spectra obtained from 12 people to predict the level of urea in samples collected from 3 different people. In this case, the standard error of prediction is 0.09 mM. Spectra were modified in order to systematically examine the impact of resolution and noise. Little impact is observed by altering the spectral resolution from 4 to 32 cm-1. Spectral noise, however, plays an important role in the accuracy of these calibration models. Increasing the magnitude of the spectral noise increases the prediction errors and increases the width of the spectral range necessary for extracting the analytical information. The utility of the method is demonstrated by analyzing dialysate samples collected during actual dialysis treatments. In addition, the necessary resolution and spectral quality necessary for reliable on-line urea monitoring is identified. These findings indicate that a dedicated, on-line urea spectrometer must posses a resolution of 16 cm-1 coupled with a sample thickness of 1.5 mm and spectral noise levels on the order of 25 micro-absorbance units when measured as the root-mean-square (RMS) noise of 100% lines.

Hemodialysis Solutions↗

Continuous oxygen monitoring of mammalian cell growth on space shuttle mission STS-93 with a novel radioluminescent oxygen sensor.

A compact, flow-through oxygen sensor device based on luminescence quenching was used to monitor dissolved oxygen levels during mammalian cell growth on the STS-93 mission of the Columbia space shuttle. Excitation of an oxygen-sensitive ruthenium complex was provided by a radioluminescent light source (0.9 mm in diameter, 2.5 mm long), and the intensity of the resulting luminescence was measured by a simple photodiode detector. The use of radioluminescence for the excitation light source is a unique approach that provides many features important for long-term and remote monitoring applications. For the spaceflight experiment, human lung fibroblast cells (WI-38) were grown in hollow-fiber bioreactors. Oxygen concentration was measured in the flow path both before and after the bioreactor cartridge in order to gain information about the metabolism of the cells. The sensor was found to be nonperturbing to cell growth and withstood the challenging physical conditions of shuttle launch and landing while maintaining a stable calibration function. In addition, the sensor provided physically meaningful oxygen predictions.

Aerospace Medicine↗

Calibration standardization algorithm for partial least-squares regression: application to the determination of physiological levels of glucose by near-infrared spectroscopy.

Calibration standardization methodology for near-infrared (near-IR) spectroscopy is described for updating a partial least-squares calibration model to take into account changes in instrumental response. The guided model reoptimization (GMR) algorithm uses a transfer set of eight samples to characterize the new response and a database of previously acquired spectra used to develop the original calibration model. The samples in the transfer set need not have been measured under the old instrumental conditions, making the algorithm compatible with samples that change over time. The spectra comprising the transfer set are used to guide an iterative optimization procedure that (1) finds an optimal subset of samples from the original database to use in computing the updated model and (2) finds an optimal set of weights to apply to the spectral resolution elements in order to minimize the effects of instrumental changes on the computed model. The optimization relies on an alternating grid search and stepwise addition/deletion steps. The algorithm is evaluated through the use of combination region near-IR spectra to determine physiological levels of glucose in a synthetic biological matrix containing bovine serum albumin and triacetin in phosphate buffer. The ability to update a calibration to account for changes in the response of a Fourier transform spectrometer over four to six years is examined in this study. Separate spectral databases collected in 1994 and 1996 are used with a transfer set and separate test set of spectra collected in 2000. With the 1994 database, the standardization algorithm achieves a standard error of prediction (SEP) of 0.69 mM for the 2000 test set. This compares favorably to SEP values > 2 mM when the original 1994 calibration model is used without standardization. A similar improvement in the prediction performance of the 2000 test set is obtained after standardization with the 1996 database (SEP = 0.70 mM).

Algorithms↗

Multivariate calibration models for lysozyme from near-infrared transmission spectra in scattering solutions of monodisperse microspheres.

The ability to quantify lysozyme is demonstrated for a series of aqueous samples with different degrees of scattering. Near-infrared spectra are collected for two sets of lysozyme/scattering solutions. In both sets of samples, the solutions are composed of lysozyme dissolved in acetate buffer with suspended monodisperse latex microspheres of polystyrene. The diameter of the microspheres is 6.4 microm for the first set and 0.6 microm for the second. For each set, the amount of microspheres range from 0.005 to 0.998 wt %, the lysozyme concentrations range from 0.834 to 28.6 mg/mL, and solution compositions are designed to minimize correlations between the concentration of lysozyme and percentage of microspheres. Near-infrared spectra are collected individually for each set of solutions. Single-beam spectra are collected over the combination spectral range (5000-4000 cm(-1), 2.0-2.5 microm) by transmitting the incident radiation through a 1.5-mm-thick sample that is maintained at 21 degrees C. Partial least-squares calibration models are evaluated individually for each data set both with and without wavelength optimization. Results indicate that models from raw, nonmodified, single-beam spectra are incapable of extracting lysozyme concentration from these highly scattering solutions. Accurate concentration measurements are possible, however, by implementing either a multiplicative scatter correction to the single-beam spectra or by taking the ratio of these single-beam spectra to an appropriate reference spectrum. In addition, digital Fourier filtering of these spectra enhances model performance. The best calibration model in the presence of 6.4-microm microspheres is obtained from multiplicative scatter corrected single-beam spectra over the 4550-4190-cm(-1) spectral range. The mean percent error of prediction (MPEP) and standard error of prediction (SEP) for this model are 2.2% and 0.28 mg/mL, respectively. Likewise, the multiplicative scatter corrected spectra with wavelength optimization provided the best calibration model for the 0.6-microm data set. In this case, the MPEP and SEP are 2.3% and 0.44 mg/mL, respectively. In addition, the ability to predict lysozyme concentrations is evaluated for the situation where the degree of scattering is greater in the predication samples compared to the calibration samples. Differences in the prediction ability are noted between the 6.4- and 0.6-microm data sets.

Microspheres↗

Nondestructive near-infrared spectroscopic measurement of multiple analytes in undiluted samples of serum-based cell culture media.

An adaptive calibration procedure is used to build selective multivariate calibration models for the measurement of glucose, lactate, glutamine, and ammonia in undiluted serum-based cell culture media. This adaptive procedure removes metabolism-induced covariance between these analytes in a series of calibration samples collected during the cultivation of PC-3 human prostate cancer cells. Partial least-squares calibration models are generated from single-beam near-infrared (NIR) spectra collected over the 4800- to 4200-cm(-1) combination spectral range. Calibration models were generated with both the full spectral range and optimized spectral ranges. In both cases, the number of model factors was optimized and model validity was determined by comparing analyte concentrations predicted from a series of independent and unaltered samples that were obtained during a subsequent cultivation of the PC-3 cells. Similar analytical performance was achieved with fewer model factors when the optimized spectral range was used. The lowest standard errors of prediction were 0.82, 0.94, 0.55, and 0.76 mM for glucose, lactate, glutamine, and ammonia, respectively. Different spectral ranges were optimal for each analyte and the optimized spectral range coincided with the distinguishing spectral features of the analyte. The results of this study demonstrate that NIR spectroscopy can be used effectively in the off-line measurement of important nutrients (glucose and glutamine) and byproducts (lactate and ammonia) in a serum-based animal cell culture medium.

Algorithms↗

Monitoring and controlling the dissolved oxygen (DO) concentration within the high aspect ratio vessel (HARV).

A probe-type oxygen sensor was developed utilizing a radioluminescent (RL)-based light source and a ruthenium-based sensing chemistry for monitoring the dissolved oxygen (DO) concentration in a modified version of the NASA-designed high aspect ratio vessel (HARV), a batch rotating wall vessel. This sensor provided the means to monitor the DO concentration in the HARV without influencing the flow pattern, thereby retaining the low shear HARV environment conducive to the formation of 3-dimensional cell aggregates. This sensor lost significant signal as a result of exposure to the first three autoclave cycles, but only minimal change in signal was observed following exposure to subsequent autoclave cycles. A new calibration model requiring only one fitted parameter was developed that accurately fit data over the entire range from 0% to 100% oxygen saturation. The ability for DO concentration control within the vessel was demonstrated by using this sensor to monitor the DO concentration inside the HARV.

Animals↗

Evaluating prostate cancer cell culturing methods: a comparison of cell morphologies and metabolic activity.

LNCaP prostate cancer cells were grown under four unique cultivation conditions. Two types of bioreactor systems were used to observe the influence of low-shear culture conditions allowing for three-dimensional growth: a) a perfusion rotating wall vessel (RWV) bioreactor; and b) a high aspect ratio vessel (HARV) RWV bioreactor, with periodic medium exchanges (fed-batch). In addition, two growth methods utilized tissue culture flasks (TCFs): a) unaltered or conventional TCFs; and b) poly(2-hydroxyethyl methacrylate) [poly(HEMA)] coated TCFs, to inhibit cell attachment. Comparisons were drawn based on qualitative observation of cell morphology and quantitative metabolic data. Similar cellular metabolism was demonstrated for cells grown under each condition. The degree of aggregation, however, varies considerably. Spherical shaped aggregates with diameters of 1 to 3 mm were produced when cells were grown within the perfusion-RWV bioreactor. All other growth conditions produced irregular shaped aggregates of various sizes. Quantitative results demonstrated the expected glucose utilization concomitant with lactate accumulation. Immunohistochemical evaluations were unremarkable for all four cultivation conditions. Results demonstrate that use of the perfusion-RWV bioreactor is advantageous in obtaining spherical aggregates, while grown in a controlled environment.

Bioreactors↗