Search PubMed⌕ Search

Biomedical subjects

Marinko V Sarunic

Publications and source records attributed to Marinko V Sarunic.

3 recordsLinked to original sources

Real-time quadrature projection complex conjugate resolved Fourier domain optical coherence tomography.

We present a novel algorithm for full-range imaging by suppression of the complex conjugate artifact in phase-shifting Fourier domain optical coherence tomography. This technique utilizes the projection of multiple phase-shifted interferograms onto an orthogonal basis set to reconstruct the complex interferogram. Full-range imaging with >30 dB suppression of the symmetric artifact is demonstrated using a 3 x 3 fiber coupler swept source OCT system, providing a depth range of 6.6mm with -8 dB roll-off in sensitivity at the depth boundaries relative to DC. Real-time display of full-range images of the anterior segment of the human eye acquired in vivo at a line rate of 6.67 kHz are presented.

Algorithms↗

Full-field swept-source phase microscopy.

We present a full-field phase microscopy technique for quantitative nanoscale surface profiling of samples in reflection. This technique utilizes swept-source optical coherence tomography in a full-field common path interferometer for phase-stable cross-sectional acquisition without scanning. Subwavelength variations in surface sample features are measured without interference from spurious reflections by processing the interferometric phase at a selected depth plane, providing a 1.3 nm stability for high signal-to-noise ratio surface features. Nanoscale imaging was demonstrated by measuring the location of receptor sites on a DNA assay biochip and the surface topography of erythrocytes in a blood smear.

Cells, Cultured↗

Spectral domain second-harmonic optical coherence tomography.

Optical coherence tomography (OCT) provides micrometer-scale structural imaging by coherent detection of backscattered light. Molecular contrast in OCT has been demonstrated using transient absorption, coherent anti-Stokes Raman scattering, and second-harmonic (SH) generation. The sensitivity of molecular contrast signals can be enhanced by use of Fourier domain techniques. We have constructed a spectrometer-based Fourier domain SH-OCT system for simultaneous acquisition of the fundamental and SH signals. We report a >30 dB increase in SH sensitivity over a similar time domain SH-OCT system and demonstrate contrast between cartilage and bone using collagen as the contrast agent.

Equipment Design↗