Search PubMed⌕ Search

Biomedical subjects

Marco Scabia

Publications and source records attributed to Marco Scabia.

4 recordsLinked to original sources

FEMMINA real-time, radio-frequency echo-signal equipment for testing novel investigation methods.

Fast echographic multiparameter multi-image novel apparatus (FEMMINA), is a hardware and software platform dedicated to ultrasonic signal and image processing. FEMMINA is able to operate with sequences of radiofrequency (RF) frames. Its architecture is designed to be modular, expandable, and aimed at implementing different ultrasonic investigation techniques. The first experimental characteristic of this system is in its capability to operate in real time with ultrasonic RF signals, starting from acquisition up to processing, storage, and visualization. The second characteristic is the user-system interactivity that allows one to modify the operation appropriately while observing results. Currently, FEMMINA works in both typical experimental situations to study novel investigation techniques and clinical field to validate the proposed methods in different human districts.

Biomedical Research↗

ICARUS: imaging pulse compression algorithm through remapping of ultrasound.

In this work we tackle the problem of applying to echographic imaging those synthetic aperture focusing techniques (SAFT) in the frequency domain commonly used in the field of synthetic aperture radars (SAR). The aim of this research is to improve echographic image resolution by using chirp transmit signals, and by performing pulse compression in both dimensions (depth and lateral). The curved geometry present in the unfocused radio-frequency (RF) ultrasonic image is the main cause of inaccuracy in the direct application of frequency domain SAFT algorithms to echographic imaging. The focusing method proposed in this work, after pulse compression in the depth dimension, performs lateral focusing in the mixed depth-lateral spatial frequency domain by means of a depth variant remapping followed by lateral pulse compression. This technique has the advantage of providing a resolution that is uniform in nonfrequency selective attenuation media, and improved with respect to conventional time domain SAFT, without requiring the acquisition and processing of channel data necessary for the most advanced synthetic transmit aperture techniques. Therefore, the presented method is suitable for easy real-time implementation with current generation hardware.

Algorithms↗

A Doppler system for dynamic vector velocity maps.

The aim of the vector Doppler technique is the quantitative reconstruction of a velocity field independently of the ultrasonic probe axis to flow angle. In particular, vector Doppler is interesting for studying vascular pathologies related to complex blood flows. A problem of vector Doppler is data representation in real-time that should be easy to interpret for the physician. In this work, we present a technique for dynamic display of vector velocity maps and some experimental results obtained in vitro with 2-D vector Doppler on flow phantoms reproducing complex flow conditions. An improvement in the map presentation was obtained by using velocity vector field interpolation. In this work, we considered the problem of spatial sampling for vector Doppler, establishing a relationship between sampling steps and scanning system characteristics. Finally, we developed a novel multimedia solution that uses both interpolated images and sound to discriminate between laminar and turbulent flows.

Blood Flow Velocity↗

Hardware and software platform for real-time processing and visualization of echographic radiofrequency signals.

In this paper the architecture of a hardware and software platform, for ultrasonic investigation is presented. The platform, used in conjunction with an analog front-end hardware for driving the ultrasonic transducers of any commercial echograph, having the radiofrequency echo signal access, make it possible to dispose of a powerful echographic system for experimenting any processing technique, also in a clinical environment in which real-time operation mode is an essential prerequisite. The platform transforms any echograph into a test-system for evaluating the diagnostic effectiveness of new investigation techniques. A particular user interface was designed in order to allow a real-time and simultaneous visualization of the results produced in the different stages of the chosen processing procedure. This is aimed at obtaining a better optimization of the processing algorithm. The most important platform aspect, which also constitutes the basic differentiation with respect to similar systems, is the direct processing of the radiofrequency echo signal, which is essential for a complete analysis of the particular ultrasound-media interaction phenomenon. The platform completely integrates the architecture of a personal computer (PC) giving rise to several benefits, such as the quick technological evolution in the PC field and an extreme degree of programmability for different applications. The PC also constitutes the user interface, as a flexible and intuitive visualization support, and performs some software signal processing, by custom algorithms and commercial libraries. The realized close synergy between hardware and software allows the acquisition and real-time processing of the echographic radiofrequency (RF) signal with fast data representation.

Computer Graphics↗