Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm(3)-525 mm(3)), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (+/-7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (+/-11.1%) for the GE scanner, 9.7% (+/-9.6%) for the Philips scanner and 7.5% (+/-7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm(3). Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies.

Analysis of Variance↗

Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

The purpose of this study was to evaluate a new algorithm for the prediction of contrast enhancement from test bolus data in cardiac multislice spiral computed tomography (MSCT). An algorithm for the prediction of contrast enhancement using test bolus data was developed. A total of 30 consecutive patients (15 male, 69.5 +/- 9.6 years) underwent cardiac MSCT (12 x 0.75 mm, 120 kV, 500 mAs(eff.)) with a biphasic contrast material injection protocol. Contrast timing was derived from a standard 20 ml test bolus injection. Based on the test bolus time attenuation curves, expected enhancement values were computed for the ascending and descending aorta and the pulmonary trunk and compared with measured data from the cardiac CT scan. At the level of the test bolus measurement in the ascending aorta, the corresponding attenuation values were 309.4 +/- 49.6 Hounsfield Units (HU) for the predicted and 285.6 +/- 42.6 HU for the measured attenuation, respectively. The mean deviation between predicted and measured CT values was 32.8 +/- 48.2 HU (upper and lower limits of agreement 101.4/-53.8 HU), indicating a slight systematic tendency for overestimation. For 80% of the patients the prediction error was less than 50 HU. Prediction of contrast enhancement in cardiac MSCT from test bolus data is feasible with a relatively small mean deviation; 80% of the predictions were within a range that might be acceptable for routine clinical application.

Aged↗

Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT.

The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos exposure and smoking habits. Of these 316, 187 (mean age: 66.6 years) individuals were included in a prospective trial. Mean asbestos exposure time was 29.65 years and 89% were smokers. Screening was performed on a 16-slice MDCT (Siemens) with low-dose technique (10/20 mAs(eff.); 1 mm/0.5 mm increment). In addition to soft copy PACS reading analysis on a workstation with a dedicated lung analysis software (LungCARE; Siemens) was performed. One strongly suspicious mass and eight cases of histologically proven lung cancer were found plus 491 additional pulmonary nodules (average volume: 40.72 ml, average diameter 4.62 mm). Asbestos-related changes (pleural plaques, fibrosis) were visible in 80 individuals. Lung cancer screening in this high-risk cohort showed a prevalence of lung cancer of 4.28% (8/187) at baseline screening with an additional large number of indeterminate pulmonary nodules. Low-dose MDCT proved to be feasible in this highly selected population.

Aged↗

The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

The accuracy of coronary calcium scoring using 16-row MSCT comparing 1- and 3-mm slices was assessed. A thorax phantom with calcium cylinder inserts was scanned applying a non-enhanced retrospectively ECG-gated examination protocol: collimation 12 x 0.75 mm; 120 kV; 133 mAs(eff). Thirty-eight patients were examined using the same scan protocol. Image reconstruction was performed with an effective slice thickness of 3 and 1 mm. The volume score, calcium mass and Agatston score were determined. Image noise was measured in both studies. The volume score and calcium mass varied less than the Agatston score. The overall measured calcium mass compared to the actual calcium mass revealed a relative difference of +2.0% for 1-mm slices and -1.2% for 3-mm slices. Due to increased image noise in thinner slices in the patient study (26.1 HU), overall calcium scoring with a scoring threshold of 130 HU was not feasible. Interlesion comparison showed significantly higher scoring results for thinner slices (all P<0.001). A similar accuracy comparing calcium scoring results of 1- and 3-mm slices was shown in the phantom study; therefore, the potentially necessary increase of the patient's dose in order to achieve assessable 1-mm slices with an acceptable image-to-noise-ratio appears not to be justified.

Aged↗

Augmented reality visualization for CT-guided interventions: system description, feasibility, and initial evaluation in an abdominal phantom.

UNLABELLED: The purpose of this study was to evaluate the feasibility and performance of an augmented reality (AR) visualization prototype for virtual computed tomography (CT)-guided interventional procedures in a multimodality abdominal phantom. With the aid of AR guidance, three radiologists performed 30 attempts at targeting simulated liver lesions of different sizes (range, 5-15 mm) with a biopsy needle. The position of the needle tip relative to the lesion was verified by using ultrasonography and CT. With AR guidance, lesions were successfully targeted with the first needle pass in all cases. On the basis of these results, AR visualization for CT-guided intervention appears feasible and allows intuitive and accurate lesion targeting in a phantom. SUPPLEMENTAL MATERIAL: radiology.rsnajnls.org/cgi/content/full/2401040018/DC1

Abdomen↗

Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children.

PURPOSE: To evaluate the value of dose-reduced 16-slice multidetector-row spiral computed tomography (16-MDCT) using virtual tracheobronchoscopy (VTB) and virtual bronchography (VBG) in children with suspected tracheobronchial stenosis. MATERIALS AND METHODS: 12 children (4 d to 3 years, body weight 1.2 kg to 13.5 kg) with stridor and suspected tracheobronchial stenosis were examined by contrast-enhanced low-dose 16-MDCT. Conventional axial slices, MPRs, VTB, and VBG were calculated. Image findings were correlated with the results of fiberoptic bronchoscopy (12 out of 12) as a gold standard and subsequent surgery (8 out of 12). RESULTS: VTB and VBG demonstrated the fiberoptic bronchoscopically suspected tracheal stenosis in 11 of 12 children due to vascular compression because of the brachiocephalic trunk (6), a double aortic arch (2), a vascular compression of the left main bronchus (2), and a right aberrant subclavian artery (1). Eleven out of 12 stenoses were correctly depicted by conventional axial slices, MPRs, VTB, and VBG. Dose reduction was 79 to 85.8% compared to a standard adult chest CT. CONCLUSION: Dose-reduced 16-MDCT with the use of VTB and VBG is effective for the evaluation of tracheobronchial stenosis in children and correlates well with fiberoptic bronchoscopy.

Airway Obstruction↗

Variability of aortic valve calcification measurement with multislice spiral computed tomography.

OBJECTIVES: We sought to assess the variability of aortic valve calcifications (AVCs) regarding the reconstruction window at different heart phases using multislice-spiral computed tomography. MATERIALS AND METHODS: A total of 46 patients (26 men; mean age. 65 years) underwent AVC scoring with multislice-spiral computed tomography (12 x 0.75 mm, 120 kV, 133 mAseff). Image reconstruction was performed every 10% of the RR-interval (0-90%). AVC was quantified using Agatston score, calcium volume, and calcium mass. Images were assessed for least motion artifacts. Coefficients of variation and Wilcoxon test were calculated. RESULTS: AVC scores are lowest at 60% and highest at 0% of the RR-interval (P < 0.001). Mean coefficients of variation were 36.2% (Agatston score), 38.7% (calcium volume), and 32.9% (calcium mass). At 60% (50-70%). minimal motion artifacts and the lowest variability of the scores were found. CONCLUSIONS: AVC scores show large variability depending on the point of image reconstruction. Diastolic image reconstruction at 60% of the RR-interval is recommended.

Adult↗

Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study.

PURPOSE: We sought to investigate the influence of heart rate and temporal resolution on the assessment of left-ventricular (LV) function with multislice spiral computed tomography (CT). MATERIAL AND METHODS: A dynamic cardiac phantom was repeatedly scanned with a 64-slice CT scanner using a standardized scan protocol (64 x 0.6 mm, 120kV, 770mAs(eff), 330 milliseconds rotation time) at different simulated heart rates, ranging from 40 to 140 beats per minute. Images were reconstructed with an algorithm utilizing data from 1 to 4 cardiac cycles (RR intervals). Ejection fraction (EF), end-systolic, end-diastolic, and stroke volume as well as cardiac output were calculated. Results of the measurements were compared with the real volumes of the phantom. Interscan and intraobserver variability were calculated. RESULTS: Using a monosegmental reconstruction algorithm, the temporal resolution was fixed to 165 milliseconds. With bi-, tri-, and quad-segmental image reconstruction, mean temporal resolution was 128.3 +/- 33.2 milliseconds, 103.3 +/- 49.2 milliseconds, and 87.8 +/- 81.5 milliseconds, respectively. Multisegmental image reconstruction resulted in a lower deviation when comparing measured and real volumes. Using mono-, bi-, tri-, and quad-segmental image reconstruction, the percent deviation between measured and real values for EF was 8.2%, 4.5%, 3.3%, and 3.4%, respectively. Applying multisegmental image reconstruction with improved temporal resolution the deviation decreased with increasing heart rate when compared with mono-segmental image reconstruction. Interscan and intraobserver variability for EF were 1.1% and 1.9%, respectively. CONCLUSION: Enhanced temporal resolution improves the quantification of LV volumes in cardiac multislice spiral CT, enabling reliable assessment of LV volumes even at increased heart rates.

Algorithms↗

Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol.

OBJECTIVES: We sought to compare an 80-kVp coronary calcium scoring protocol with the standard protocol of 120 kVp in terms of accuracy and reproducibility and to assess its dose reduction potential. MATERIALS AND METHOD: An anthropomorphic heart phantom with calcium cylinders was scanned with different tube currents at 80 kVp and 120 kVp using a 16-slice multislice CT (MSCT) scanner. An adapted threshold for 80 kVp was calculated. Accuracy and reproducibility for calcium mass, volume, and Agatston score were analyzed using F-tests. The radiation doses needed to produce artifact-free images were determined. RESULTS: Accuracy (measurement errors: mass 120 kVp +4.6%, mass 80 kVp -6.9%, volume 120 kVp +78.8%, volume 80 kVp +58.2%) and reproducibility (F-tests: mass: P = 0.4998, volume: P = 0.9168, Agatston: P = 0.5422) were comparable at both tube voltages. Avoiding the appearance of artificial lesions, a CTDI(w,eff) of 10.7 mGy was needed at 120 kVp versus 4.6 mGy at 80 kVp (dose reduction of 57%). CONCLUSIONS: Using an 80-kVp protocol in coronary calcium scoring, a relevant dose reduction is possible without compromising reproducibility and accuracy.

Analysis of Variance↗

Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance.

PURPOSE: To prospectively compare the effects of two computer-aided detection (CAD) systems on the detection of small pulmonary nodules at multi-detector row computed tomography (CT) by using a consensus panel decision as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Multi-detector row CT scans were randomly chosen and prospectively evaluated in 25 patients. Two dedicated CAD systems-ImageChecker CT (R2 Technologies, Sunnyvale, Calif) and Nodule Enhanced Viewing (NEV) (Siemens Medical Solutions, Forchheim, Germany)-were used. Results were interpreted by three radiologists with 1, 3, and 6 years of experience. Images were evaluated without and with CAD software. The reference standard was assessed by a consensus panel consisting of all three radiologists and an adjudicator with 8 years of experience. RESULTS: A total of 116 pulmonary nodules (average diameter, 3.4 mm; average volume, 32.05 mm3) were found in all data sets during consensus interpretation, which included findings from the CAD software and all radiologists. Overall sensitivity was 73% with ImageChecker CT and 75% with NEV. Overall sensitivity without CAD was 68% for radiologist 1, 78% for radiologist 2, and 82% for radiologist 3. With ImageChecker CT, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 84% for radiologist 3. With NEV, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 86% for radiologist 3. The average number of false-positive findings was six (range, 0-14) with ImageChecker CT and eight (range, 0-22) with NEV. CONCLUSION: Radiologist performance in the interpretation of multi-detector row CT scans can be improved by using CAD systems, with a reduction in the number of false-negative diagnoses. No statistically significant difference in sensitivity was found between the two CAD systems.

Adult↗

Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm.

The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2+/-1.0 vs. 2.6+/-0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P<or=0.0001); the limits of agreement for the ejection fraction were 2.3+/-8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective.

Aged↗

Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study.

The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6+/-10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180x180, 220x220, 380x380 mm(2)). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180x180 mm(2) was 657.80+/-20.05. At a FOV of 220x220 mm(2) and 380x380 mm(2), the corresponding values were 657.04+/-21.36 and 655.04+/-20.74, respectively. The corresponding values in the patient study were 541.65+/-869.87, 541.91+/-872.57 and 536.61+/-867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180x180 mm(2) and 220x220 mm(2) (380x380 mm(2)), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring.

Adult↗

Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography.

The aims of this study were to optimize image quality for indirect CT venography (sequential versus spiral), and to evaluate different image reconstruction parameters for patients with suspected deep venous thrombosis (DVT). Fifty-one patients (26/25 with/without DVT) were prospectively evaluated for pulmonary embolism (PE) with standard multidetector-row computed tomography (MDCT) protocols. Retrospective image reconstruction was done with different slice thicknesses and reconstruction increments in sequential and spiral modes. All reconstructions were read for depiction of DVT and to evaluate best reconstruction parameters in comparison with the thinnest reconstruction ("gold standard"). Image noise and venous enhancement were measured as objective criteria for image quality. Subjective image quality was rated on a four-point scale. Effective dose was estimated for all reconstructions. In sequential 10/50 reconstruction DVT was completely detected in 13/26 cases, partially in 10/26 cases and was not detected at all in 3/26 cases, and 15/26, 9/26 and 2/26 cases for the 10/20 reconstruction, respectively. DVT was completely detected in all spiral reconstructions. Image noise ranged between 14.8-29.1 HU. Median image quality was 2. Estimated effective dose ranged between 2.3 mSv and 11.8 mSv. Gaps in sequential protocols may lead to false negative results. Therefore, spiral scanning protocols for complete depiction of DVT are mandatory.

Adult↗

CT imaging in acute pulmonary embolism: diagnostic strategies.

Computed tomography pulmonary angiography (CTA) has increasingly become accepted as a widely available, safe, cost-effective, and accurate method for a quick and comprehensive diagnosis of acute pulmonary embolism (PE). Pulmonary catheter angiography is still considered the gold standard and final imaging method in many diagnostic algorithms. However, spiral CTA has become established as the first imaging test in clinical routine due to its high negative predictive value for clinically relevant PE. Despite the direct visualization of clot material, depiction of cardiac and pulmonary function in combination with the quantification of pulmonary obstruction helps to grade the severity of PE for further risk stratification and to monitor the effect of thrombolytic therapy. Because PE and deep venous thrombosis are two different aspects of the same disease, additional indirect CT venography may be a valuable addition to the initial diagnostic algorithm-if this was positive for PE-and demonstration of the extent and localization of deep venous thrombosis has an impact on clinical management. Additional and alternate diagnoses add to the usefulness of this method. Using advanced multislice spiral CT technology, some practitioners have advocated CTA as the sole imaging tool for routine clinical assessment in suspected acute PE. This will simplify standards of practice in the near future.

Acute Disease↗

Coronary calcium scoring using 16-row multislice computed tomography: nonenhanced versus contrast-enhanced studies in vitro and in vivo.

OBJECTIVES: We sought to assess the agreement of coronary artery calcium score in nonenhanced and contrast-enhanced multislice-spiral computed tomography. MATERIALS AND METHODS: Vessel phantoms and 36 patients underwent nonenhanced and contrast-enhanced cardiac multislice-spiral computed tomography (Sensation 16; Siemens, Germany). Reconstruction-parameters: slice thickness 3 mm, increment 2 mm, kernels B35f and B30f. The Agatston score, calcium mass, and number of lesions were calculated. Images were scored using detection thresholds of 130 Hounsfield units (HU) and 350 HU. Based on the Agatston score, risk stratification was performed. RESULTS: In the phantom and patient study, altering the threshold from 130 to 350 HU led to a significant decrease in the mean Agatston score (phantom: 54.6%, patients: 66.7%) and calcium mass (33.0%, 47.0%) (B35f). Contrast-enhanced studies (threshold: 350 HU) showed an increase of the mean Agatston score (71.0%, 20.7%) and calcium mass (81.0%, 16.0%) when compared with nonenhanced scans (threshold: 350 HU). A total of 57% of all patients were assigned to different risk groups. CONCLUSIONS: Contrast material may simulate calcification; therefore, calculation of the coronary calcium score from contrast-enhanced images is not reliable.

Calcinosis↗

Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo.

OBJECTIVES: To compare coronary calcium scoring results (calcium volume, calcium mass, Agatston score, and number of lesions) of different slice thicknesses using a 16-slice CT (MSCT) scanner. MATERIALS AND METHODS: A nonmoving anthropomorphic thorax phantom with calcium cylinders of different sizes and densities was scanned 30 times with repositioning applying a standardized retrospectively ECG-gated MSCT (SOMATOM Sensation 16; Siemens, Forchheim, Germany) scan protocol: collimation 12 x 0.75 mm, tube voltage 120 kV, effective tube current time-product 133 mAs(eff). Fifty patients (29 male; age 57.2 +/- 8.4 years) underwent a nonenhanced scan applying the same scan protocol. Two image sets (effective slice thicknesses 3 mm and 1 mm) were reconstructed at 60% of the RR interval. Image noise was measured in both studies. Calcium volume, calcium mass and Agatston score were calculated using a commercially available software tool. RESULTS: Due to increased image noise in thinner slices, calcium scoring in all scans was performed applying a scoring threshold of 350 HU. In the phantom study, 1-mm slices showed significantly higher scoring results in respect to calcium volume (+8.2%), calcium mass (+12.5%), and Agatston score (+5.3%) (all P < 0.0001). In the patient study, 27 patients had coronary calcifications in 3-mm slices, and 31 patients had coronary calcifications in 1-mm slices. Thinner slices showed significantly higher scoring results in respect to volume (+47.1%), mass (+47.2%), and Agatston score (+29.7%) (all P < 0.0001). CONCLUSIONS: When comparing 3-mm and 1-mm slices in coronary calcium scoring in MSCT, thinner slices lead to significantly increased scoring results.

Aged↗

Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield.

OBJECTIVE: Our study was designed to quantify the effect of a standard gonad shield on the testicular radiation exposure due to scatter during routine abdominopelvic MDCT. SUBJECTS AND METHODS: Routine abdominopelvic MDCT was performed in 34 patients with gonadal lead shielding and 32 patients without this shielding; the testes were not exposed to the direct beam during the examination. We estimated the testicular dose administered with thermoluminescent dosimetry, taking into account each patient's body weight and body mass index (BMI). RESULTS: With a 1-mm lead shield, the mean testicular dose was reduced from 2.40 to 0.32 mSv, a reduction of 87%. The difference was found to be statistically significant (p < 0.0001). No correlation between testicular dose and body weight or BMI was found. CONCLUSION: Shielding the male gonads reduces the testicular radiation dose during abdominopelvic MDCT significantly and can be recommended for routine use.

Adult↗

Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

OBJECTIVE: The purpose of our study was to develop a simple protocol for reduction of radiation exposure without loss of diagnostic information in chest 16-MDCT. MATERIALS AND METHODS: Two hundred and four patients underwent MDCT of the thorax (Somatom Sensation 16, Siemens). Group 1 was scanned using a standard protocol with 100 mAs(effective) (mAs(eff)). Group 2 was scanned using a dose modulation template (CareDose). Group 3 was scanned with mAs(eff) = body weight (kg). Group 4 was scanned with a combination of weight-adapted mAs(eff) and dose modulation. All other parameters were kept constant. Signal-to-noise ratio was assessed as an objective measurement for image quality, and subjective image quality was rated by three experienced radiologists on a 4-point scale. Effective dose was calculated using dedicated software. RESULTS: The mean noise measurement values were 8.31 H for the 100 mAs(eff) protocol for the regression between weight and signal-to-noise (p < 0.0001), 9.08 H for group 2 (p < 0.0001), 9.0 H for group 3 (p = 0.5051), and 9.98 H for group 4 (p = 0.0152). The median image quality was 1 (1 = highest quality) in all subgroups. The mean effective dose was 6.83 mSv, 5.92 mSv, 4.73 mSv, and 3.97 mSv, respectively. The least correlation between weight and image noise was achieved for the individually weight-adapted protocol and in the weight-adapted with CareDose combination. CONCLUSION: By tube current time product adaptation (kg = mAs(eff)) combined with an online tube current modulation template, a well-balanced examination without significant loss of information was achieved for this specific scanner. Thus, individually adapted protocols for chest 16-MDCT can be recommended.

Algorithms↗