Speech understanding in background noise with the two-microphone adaptive beamformer BEAM in the Nucleus Freedom Cochlear Implant System.

OBJECTIVE: This paper evaluates the benefit of the two-microphone adaptive beamformer BEAM in the Nucleus Freedom cochlear implant (CI) system for speech understanding in background noise by CI users. DESIGN: A double-blind evaluation of the two-microphone adaptive beamformer BEAM and a hardware directional microphone was carried out with five adult Nucleus CI users. The test procedure consisted of a pre- and post-test in the lab and a 2-wk trial period at home. In the pre- and post-test, the speech reception threshold (SRT) with sentences and the percentage correct phoneme scores for CVC words were measured in quiet and background noise at different signal-to-noise ratios. Performance was assessed for two different noise configurations (with a single noise source and with three noise sources) and two different noise materials (stationary speech-weighted noise and multitalker babble). During the 2-wk trial period at home, the CI users evaluated the noise reduction performance in different listening conditions by means of the SSQ questionnaire. In addition to the perceptual evaluation, the noise reduction performance of the beamformer was measured physically as a function of the direction of the noise source. RESULTS: Significant improvements of both the SRT in noise (average improvement of 5-16 dB) and the percentage correct phoneme scores (average improvement of 10-41%) were observed with BEAM compared to the standard hardware directional microphone. In addition, the SSQ questionnaire and subjective evaluation in controlled and real-life scenarios suggested a possible preference for the beamformer in noisy environments. CONCLUSIONS: The evaluation demonstrates that the adaptive noise reduction algorithm BEAM in the Nucleus Freedom CI-system may significantly increase the speech perception by cochlear implantees in noisy listening conditions. This is the first monolateral (adaptive) noise reduction strategy actually implemented in a mainstream commercial CI.

Adult↗

Factors affecting the use of noise-band vocoders as acoustic models for pitch perception in cochlear implants.

Although in a number of experiments noise-band vocoders have been shown to provide acoustic models for speech perception in cochlear implants (CI), the present study assesses in four experiments whether and under what limitations noise-band vocoders can be used as an acoustic model for pitch perception in CI. The first two experiments examine the effect of spectral smearing on simulated electrode discrimination and fundamental frequency (FO) discrimination. The third experiment assesses the effect of spectral mismatch in an FO-discrimination task with two different vocoders. The fourth experiment investigates the effect of amplitude compression on modulation rate discrimination. For each experiment, the results obtained from normal-hearing subjects presented with vocoded stimuli are compared to results obtained directly from CI recipients. The results show that place pitch sensitivity drops with increased spectral smearing and that place pitch cues for multi-channel stimuli can adequately be mimicked when the discriminability of adjacent channels is adjusted by varying the spectral slopes to match that of CI subjects. The results also indicate that temporal pitch sensitivity is limited for noise-band carriers with low center frequencies and that the absence of a compression function in the vocoder might alter the saliency of the temporal pitch cues.

Acoustic Stimulation↗

Horizontal localization with bilateral hearing aids: without is better than with.

This paper studies the effect of bilateral hearing aids on directional hearing in the frontal horizontal plane. Localization tests evaluated bilateral hearing aid users using different stimuli and different noise scenarios. Normal hearing subjects were used as a reference. The main research questions raised in this paper are: (i) How do bilateral hearing aid users perform on a localization task, relative to normal hearing subjects? (ii) Do bilateral hearing aids preserve localization cues, and (iii) Is there an influence of state of the art noise reduction algorithms, more in particular an adaptive directional microphone configuration, on localization performance? The hearing aid users were tested without and with their hearing aids, using both a standard omnidirectional microphone configuration and an adaptive directional microphone configuration. The following main conclusions are drawn. (i) Bilateral hearing aid users perform worse than normal hearing subjects in a localization task, although more than one-half of the subjects reach normal hearing performance when tested unaided. For both groups, localization performance drops significantly when acoustical scenarios become more complex. (ii) Bilateral, i.e., independently operating hearing aids do not preserve localization cues. (iii) Overall, adaptive directional noise reduction can have an additional and significant negative impact on localization performance.

Acoustic Stimulation↗

Improved music perception with explicit pitch coding in cochlear implants.

Music perception and appraisal is very poor in cochlear implant (CI) subjects partly because (musical) pitch is inadequately transmitted by the current clinically used sound processors. A new sound processing scheme (F0mod) was designed to optimize pitch perception, and its performance for music and pitch perception was compared in four different experiments to that of the current clinically used sound processing scheme (ACE) in six Nucleus CI24 subjects. In the F0mod scheme, slowly varying channel envelopes are explicitly modulated sinusoidally at the fundamental frequency (F0) of the input signal, with 100% modulation depth and in phase across channels to maximize temporal envelope pitch cues. The results of the four experiments show that: (1) F0 discrimination of single-formant stimuli was not significantly different for the two schemes, (2) F0 discrimination of musical notes of five instruments was three times better with the F0mod scheme for F0 up to 250 Hz, (3) melody recognition of familiar Flemish songs (with all rhythm cues removed) was improved with the F0mod scheme, and (4) estimates of musical pitch intervals, obtained in a musically trained CI subject, matched more closely the presented intervals with the F0mod scheme. These results indicate that explicit F0 modulation of the channel envelopes improves music perception in CI subjects.

Adult↗

A flexible auditory research platform using acoustic or electric stimuli for adults and young children.

A user-friendly and versatile research platform for use in auditory experiments, referred to as APEX (Application for PsychoElectrical eXperiments), is described. The platform takes care of automatic stimulus presentation and collection of the subject's responses. Acoustical auditory, as well as electrical auditory experiments with CI recipients can be conducted. The platform currently supports LAURA, Nucleus CI22 and Nucleus CI24 cochlear implants. The graphical user interface for the subjects has been extended to allow for testing very young children, by embedding the psychophysical procedures in a computer game. The research platform is available free of charge.

Acoustic Stimulation↗

SVD-based optimal filtering for noise reduction in dual microphone hearing aids: a real time implementation and perceptual evaluation.

In this paper, the first real-time implementation and perceptual evaluation of a singular value decomposition (SVD)-based optimal filtering technique for noise reduction in a dual microphone behind-the-ear (BTE) hearing aid is presented. This evaluation was carried out for a speech weighted noise and multitalker babble, for single and multiple jammer sound source scenarios. Two basic microphone configurations in the hearing aid were used. The SVD-based optimal filtering technique was compared against an adaptive beamformer, which is known to give significant improvements in speech intelligibility in noisy environment. The optimal filtering technique works without assumptions about a speaker position, unlike the two-stage adaptive beamformer. However this strategy needs a robust voice activity detector (VAD). A method to improve the performance of the VAD was presented and evaluated physically. By connecting the VAD to the output of the noise reduction algorithms, a good discrimination between the speech-and-noise periods and the noise-only periods of the signals was obtained. The perceptual experiments demonstrated that the SVD-based optimal filtering technique could perform as well as the adaptive beamformer in a single noise source scenario, i.e., the ideal scenario for the latter technique, and could outperform the adaptive beamformer in multiple noise source scenarios.

Adult↗

Noise reduction results of an adaptive filtering technique for dual-microphone behind-the-ear hearing aids.

OBJECTIVE: The performance of an adaptive beam-former in a 2-microphone, behind-the-ear hearing aid for speech understanding in noisy environments was evaluated. Physical and perceptual evaluations were carried out. This was the first large-scale test of a wearable real-time implementation of this algorithm. The main perceptual research questions of this study were related to the influence on the noise reduction performance of (1) the spectro-temporal character of the jammer sound, (2) the jammer sound scene, (3) hearing impairment, and (4) the basic microphone configuration in the hearing aid. Four different speech materials were used for the perceptual evaluations. All tests were carried out in an acoustical environment comparable to living room reverberation. DESIGN: The adaptive beamformer was implemented in Audallion, a small, body-worn processor, linked to a Danasound 2-microphone behind-the-ear aid. The strategy was evaluated physically in different acoustical environments. Using speech reception threshold (SRT) measurements, the processing was evaluated perceptually and the different research questions addressed with three groups of subjects. Groups I, II, and III consisted of 10 normal-hearing, 5 hearing-impaired, and 7 normal-hearing persons, respectively. The tests were carried out in three spectro-temporally different jammer sounds (unmodulated and modulated speech weighted noise, multitalker babble) and in three different noise scenarios (single noise source at 90 degrees, noise sources at 90 degrees and 270 degrees relative to speaker position, diffuse noise scene). Two microphone configurations were compared: a device equipped with two omnidirectional microphones and a device equipped with one hardware directional and one omnidirectional microphone. In each of these conditions, the adaptive beamformer and the directional and omnidirectional microphone configurations were tested. RESULTS: The improvement in signal-to-noise ratio from the use of the adaptive beamformer did not depend on the spectro-temporal character of the jammer sounds and the speech materials used, although the absolute levels of the SRTs varied appreciably for different speech-noise combinations. The performance of the adaptive noise reduction depended on the jammer sound scene. CONCLUSIONS: No difference in signal-to-noise ratio improvement was observed between hearing-impaired and normal-hearing listeners, although individual SRT levels may differ. On average, an SRT improvement of 7.7 and 3.9 dB for a single noise source at 90 degrees and 5.9 and 3.4 dB for two noise sources at 90 degrees and 270 degrees was obtained for both normal-hearing and hearing-impaired listeners, using the adaptive beamformer and the directional microphone, respectively, relative to the omnidirectional microphone signal. In diffuse noise, only small improvements were obtained.

Adult↗

Relative contributions of temporal and place pitch cues to fundamental frequency discrimination in cochlear implantees.

The effect of the filter bank on fundamental frequency (F0) discrimination was examined in four Nucleus CI24 cochlear implant subjects for synthetic stylized vowel-like stimuli. The four tested filter banks differed in cutoff frequencies, amount of overlap between filters, and shape of the filters. To assess the effects of temporal pitch cues on F0 discrimination, temporal fluctuations were removed above 10 Hz in one condition and above 200 Hz in another. Results indicate that F0 discrimination based upon place pitch cues is possible, but just-noticeable differences exceed 1 octave or more depending on the filter bank used. Increasing the frequency resolution in the F0 range improves the F0 discrimination based upon place pitch cues. The results of F0 discrimination based upon place pitch agree with a model that compares the centroids of the electrical excitation pattern. The addition of temporal fluctuations up to 200 Hz significantly improves F0 discrimination. Just-noticeable differences using both place and temporal pitch cues range from 6% to 60%. Filter banks that do not resolve the higher harmonics provided the best temporal pitch cues, because temporal pitch cues are clearest when the fluctuation on all channels is at F0 and preferably in phase.

Adult↗