Search PubMed⌕ Search

Biomedical subjects

Marc L Schermerhorn

Publications and source records attributed to Marc L Schermerhorn.

15 recordsLinked to original sources

Current status of carotid artery stenting.

This Clinical Update summarizes the results of larger case series, industry-sponsored registries, and randomized trials of carotid artery stenting (CAS). In >20 case series that studied >24,000 patients undergoing CAS, 51% of patients were symptomatic, most procedures (97%) resulted in successful stent deployment, and 30-day stroke rates varied from 1% to 8%, with a trend toward lower rates as experience and embolic protection device (EPD) use increased. In 12 industry-sponsored registries (none were published in peer-reviewed journals), 30-day stroke rates varied from 2% to 7%, and 30-day combined adverse events, including stroke, death, and myocardial infarction, were 3% to 9%. More than 12 randomized trials comparing CAS and carotid endarterectomy (CEA) have been initiated since 1998. Results have varied over time, depending on the population studied and the technology used. However, the largest and most recent results of the completed SAPPHIRE trial in high-risk patients undergoing CAS with the use of EPDs demonstrated that CAS is at least not inferior to CEA, with a 1-year combined adverse event rate of 12% for CAS and 20% for CEA (P = .05). Other ongoing trials will address not only whether CAS could be superior to CEA in high-risk patients but also, more importantly, whether CAS is beneficial in other subgroups, such as low-risk and asymptomatic patients.

Angioplasty↗

Outcomes of renal artery angioplasty and stenting using low-profile systems.

OBJECTIVE: Renal artery percutaneous transluminal angioplasty (RPTA) and stenting (RAS) are accepted therapies for selected patients with renovascular hypertension and chronic renal insufficiency. We evaluated the outcomes and complications of RAS performed by vascular surgeons at our institution with modern low-profile systems. METHOD: We retrospectively analyzed all RPTA and RAS procedures attempted with the use of low-profile systems from June 2000 to September 2003. Eighty-two patients (96 arteries) with atherosclerotic renal artery stenosis were treated. Indication for treatment was hypertension in 44 (54%) and chronic renal insufficiency in 38 (46%). Technical success, complication rates, clinical success for control of hypertension or renal insufficiency, restenosis, and survival were reviewed with a mean follow-up of 1 year. RESULTS: Ninety-three arteries were treated with stents, three with RPTA only. Primary technical success was 95%, with 98% overall technical success. Major complications occurred in 6.1% and minor complications in 1.2%. Hypertension was improved in 81% at 1 year. Renal function was improved in 23%, stable in 53%, and worse in 24% at 1 year. Restenosis was seen by routine duplex surveillance in 25% at 1 year. Restenosis associated with clinical deterioration and confirmed by angiogram was seen in 10%. The overall 3-year survival was 83%. CONCLUSION: RPTA/RAS can be performed with low-profile systems with excellent technical success, low complication rates, and clinical outcomes that compare favorably with prior reports.

Angioplasty, Balloon↗

Restenosis in gold-coated renal artery stents.

BACKGROUND: Gold coating improves stent visibility under fluoroscopy. This is particularly valuable for precise stent placement during renal artery stenting (RAS). There is conflicting evidence regarding restenosis with gold-coated stents. To evaluate the effect of gold coating on restenosis after renal stenting, we reviewed the results of all patients undergoing RAS in our practice. METHODS: A retrospective cohort study of all patients undergoing RAS between June 2000 and September 2003 was performed. During this time, both gold-coated and stainless steel stents were used. Restenosis (>60% diameter) was determined by serial follow-up duplex exams (peak systolic velocity >180 cm/s and renal-aortic ratio >3.5). Restenosis rates were determined by using the Kaplan-Meier life-table method. Variables potentially affecting restenosis were evaluated with the log-rank test and Cox proportional hazards modeling. RESULTS: RAS was performed in 97 arteries (78 patients). Gold-coated (NIRoyal) stents were placed in 59 arteries (48 patients). Stainless steel stents (Corinthian, Genesis, and Herculink) were placed in 38 arteries (34 patients). Patient demographics, indication for treatment, technical success, and complications did not differ between gold and stainless steel stent groups. Mean follow-up was 15 months for gold-coated stents and 18 months for stainless steel stents (NS). By life-table method, 1-year and 2-year freedom from restenosis rates were 84% and 78% in arteries treated with stainless steel stents versus 69% and 39% in those treated with gold-coated stents (P = .012, log-rank test). By multivariate analysis, only the use of gold-coated stents (P = .018; hazard ratio [HR], 3.3; 95% confidence interval [CI], 1.2 to 8.7) and bilateral disease (P = .046; HR, 2.3; 95% CI, 1.02 to 5.2) predicted restenosis. Stent diameter, patient demographics, and indication for RAS had no effect on restenosis by univariate analysis. According to American Heart Association criteria, 87% of patients in the stainless steel group had improved blood pressure at 1 year, compared with 77% in the gold-coated stent group (Kaplan-Meier; P = .042, log-rank test). There were no significant differences in the effect of RAS on serum creatinine levels between the two groups. CONCLUSION: Gold-coated renal stents had a substantially higher rate of restenosis than stainless steel stents in our series. These findings have led us to abandon the use of gold-coated stents for RAS. Patients who have received gold-coated stents for the treatment of atherosclerotic renal artery stenosis should be followed closely for evidence of restenosis.

Aged↗

Mesenteric stenting for chronic mesenteric ischemia.

BACKGROUND: Mesenteric stenting has not been widely adopted for the treatment of chronic mesenteric ischemia (CMI). The recent availability of embolic protection and low-profile devices with the theoretical ability to decrease perioperative bowel necrosis, led us to begin using mesenteric stenting for patients with CMI. We review our initial experience to examine short-term outcomes. METHODS: We performed a retrospective analysis of all patients who were treated by vascular surgeons with mesenteric stenting for CMI. Patients with acute mesenteric ischemia were excluded. We evaluated perioperative morbidity and mortality, restenosis, recurrent symptoms, and reintervention. Kaplan-Meier methods were used to assess events during follow-up. We also compared these outcomes with a historical control group of patients treated with open surgical revascularization. RESULTS: Fourteen patients underwent mesenteric stenting over the past 3 years. Mean age was 73, and 64% were women. There was no perioperative or 30-day mortality or major morbidity. Early restenosis and recurrent symptoms occurred in 10% and 9% of patients at 6 months. At a mean follow-up of 13 months, 53% of patients underwent reintervention. However, 93% were symptom-free at their last follow-up. Compared with open surgery, stent patients had lower perioperative major morbidity (30% vs 0%, P < .01) and shorter hospital and intensive care unit length of stay (median 10 days vs 2 days, and 3 days vs 0 days, respectively, P < .01 for both). However, stent patients were seven times as likely to develop restenosis (P < .01), four times more likely to develop recurrent symptoms (P < .01), and 15 times more likely to undergo reintervention (P < .01). There was one death 13 months after stenting due to mesenteric infarction in a patient lost to follow-up. One patient was successfully converted to open surgery after a second restenosis. He had regained 20 pounds and was determined to be a better operative candidate than at his initial presentation. There was no perioperative or 30-day mortality or major morbidity with reintervention after mesenteric stenting. CONCLUSION: Mesenteric stenting for CMI can be performed with low perioperative risk. However, stenting is associated with early restenosis and recurrent symptoms requiring secondary procedures. Patients with severe nutritional depletion or high surgical risk may benefit from mesenteric stenting for CMI, but close follow-up is required. Later open surgery can be performed for restenosis if nutritional status and surgical risk are improved, or repeat angioplasty and stenting can be effectively performed if operative risk remains high.

Aged↗

Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

OBJECTIVE: The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. METHODS: Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. RESULTS: CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). CONCLUSIONS: When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.

Aged↗

Stent-graft treatment of a large internal carotid artery vein graft aneurysm.

Aneurysm degeneration of internal carotid artery interposition vein grafts can occur, and their repair can be complicated by repeated neck dissection and difficulty in obtaining distal artery control. We used a covered stent graft to exclude a large internal carotid artery interposition vein graft aneurysm. Retrograde flow was induced in the internal carotid artery so that an embolization protection balloon could be placed through the aneurysm. The stent graft was then placed with embolization protection. The repair was performed without complication, and the aneurysm remained successfully excluded at 6-month follow-up.

Aneurysm↗

Early results of stent-grafting to treat diffuse aortoiliac occlusive disease.

INTRODUCTION: Diffuse aortoiliac occlusive disease or isolated external iliac artery occlusion >or=10 cm long typically are treated with surgical bypass grafting because of limited durability of stent placement. We evaluated the results of stent-graft placement as an option for treatment of these diseases. METHODS: Demographic data for patients undergoing stent-grafting in one or more iliac artery segments were recorded. Technical, clinical, and hemodynamic success, and aortoiliac primary and secondary patency were analyzed with Society for Vascular Surgery/American Association for Vascular Surgery criteria. RESULTS: Thirty-four consecutive patients underwent stent-graft treatment because of rest pain (65%) or tissue loss (35%). Mean patient age was 63 years, and 38% of patients were women. Ninety-one percent of patients had hypertension, 71% had coronary artery disease, 21% had renal insufficiency (serum creatinine > 2.0 mg/dL), and 26% had diabetes; 71% were active smokers. TransAtlantic Inter-Society Consensus C or D disease was present in 85% of patients, complete common or external iliac artery occlusion was present in 41%, and external iliac artery disease requiring treatment was present in 94% of patients. Mean lesion length was 13.7 +/- 8 cm. Technical, hemodynamic, and clinical success was achieved in all patients in whom the lesion could be crossed with a wire. Ankle-brachial index increased from.30 +/-.03 to.59 +/-.04. Self-expanding stent grafts were used (Wallgraft, Boston Scientific, Boston, Mass, in 88% of patients; Viabahn, W. L. Gore, Flagstaff, Ariz, in 12% of patients). Concomitant common femoral endarterectomy was performed in 53% of patients. At 12 months, primary patency was 70% and primary assisted patency was 88%. Four stent grafts became occluded because of distal external iliac artery or proximal common femoral artery disease, which required subsequent common femoral endarterectomy and either external iliac artery stent grafting or extraanatomic bypass grafting. Eighty percent (four of five) of primary patency failures were in patients who did not undergo concomitant common femoral endarterectomy at initial stent graft placement. CONCLUSION: Early results of stent-graft placement to treat diffuse aortoiliac occlusive disease appear better than our recent experience with stenting alone. Concomitant common femoral endarterectomy or better assessment of femoral disease may improve durability.

Adult↗

Blinded comparison of preoperative duplex ultrasound scanning and contrast arteriography for planning revascularization at the level of the tibia.

PURPOSE: We examined whether preoperative duplex ultrasound scanning (DU) could replace contrast material-enhanced arteriography (CA) in selecting the recipient artery of tibial or peroneal artery bypass grafts. METHODS: In patients who underwent tibial or peroneal artery bypass grafting because of critical ischemia, images were obtained of the lower extremity arterial circulation with both DU and CA. Vascular surgeons, blinded to the operation performed, reviewed either DU or CA images for arterial visualization and patency. The tibial or peroneal artery best suited to receive the bypass graft was selected by surgeons using only data from either DU or CA images. This selection was compared with the artery actually used at bypass surgery. RESULTS: Preoperative DU and CA data for 40 lower extremities in 38 patients undergoing bypass grafting at the level of the tibia provided 110 arteries: 38 anterior tibial arteries, 32 peroneal arteries, and 40 posterior tibial arteries. Ten arteries (8 peroneal, 2 anterior tibial) were not identified with DU, and 1 artery (anterior tibial) was not identified with CA. DU enabled prediction of the artery actually used in 88% of patients (35 of 40), whereas CA enabled prediction of the artery actually used in 93% of patients (37 of 40; P =.59). Duplicate findings at DU and CA enabled selection of 85% of arteries actually used (95% confidence interval, 71%-93%). Arteries used for bypass grafting had significantly higher peak systolic velocity (35 cm/s vs 25 cm/s; P =.04), higher end-diastolic velocity (15 cm/s vs 9 cm/s; P =.005), and greater diameter (2.4 mm vs 1.7 mm; P =.003) compared with arteries not selected for bypass grafting. CONCLUSION: Findings at DU and CA typically agree when used to select tibial or peroneal arteries for bypass grafting. With DU there is occasional difficulty in identification of the peroneal artery, but selection of the actual artery used is accurate. Peak systolic velocity, end-diastolic velocity, and diameter characteristics correlate with arteriographic criteria for tibial bypass target artery selection. If DU enables adequate identification of a target artery for bypass grafting, and especially if the peroneal artery is seen, findings at CA are not likely to alter bypass execution.

Adult↗

Endovascular repair of abdominal aortic aneurysm without preoperative arteriography.

OBJECTIVE: Clinical trials of endovascular aortic aneurysm repair (EVAR) have required both preoperative aortography and computed tomography (CT). We codeveloped specialized three-dimensional (3-D) reconstruction and computer-aided measurement, planning, and simulation software (3-D CAMPS) based on CT or magnetic resonance imaging, to eliminate the need for preoperative arteriography. METHODS: EVAR with 3-D CAMPS as the sole preoperative imaging method was performed in 196 patients from 1996 to 2001, with six endograft types in three configurations. Physical examination, abdominal radiography, and CT (3D-CAMPS) were performed at 1, 6, and 12 months, then annually. RESULTS: For a subset of cases in which a comparison could be made, 3-D CAMPS was superior to angiography for prediction of endograft length and iliac access. Hospital mortality was zero, and 30-day mortality was 0.5%. In three patients immediate conversion to open repair (1.5%) was necessary because of previously unknown stent-graft mechanical limits. Incidence of endoleak was 15% at 1 month, 10% at 6 months, 6% at 12 months, and 7% at 24 months, and 92% of endoleaks were type II. Mean follow-up was 18 months. Aneurysm-related mortality was zero. Nineteen secondary procedures (all endovascular) were performed in 16 patients (8%). For all graft types, freedom from secondary procedure was 94% at 1 year and 90% at 2 years, and this was better for endografts ultimately approved by the US Food and Drug Administration (96% at 1 year, 95% at 2 years; P =.02). No known measurement-related complications occurred in the series. Results for secondary intervention and endoleak compare favorably to series with similar endograft types. CONCLUSIONS: EVAR can be performed with 3-D CAMPS as the sole preoperative imaging method to achieve outcomes comparable to the best series published for each endograft type. CT with 3-D CAMPS can effectively eliminate the need for preoperative arteriography and avert associated morbidity, expense, and exposure to contrast agent and radiation.

Aged↗

Early results of external iliac artery stenting combined with common femoral artery endarterectomy.

PURPOSE: The endovascular approach to external iliac artery (EIA) disease extending into the common femoral artery (CFA) has been avoided because of problems with stent placement across the inguinal ligament. Surgical treatment for this disease distribution includes extensive endarterectomy or bypass procedures or both. We report our initial experience with a combined open and endovascular approach to these patients. METHODS: We performed a retrospective analysis of all patients who underwent intraoperative EIA stenting after CFA endarterectomy/patch angioplasty between 1997 and 2000. Stents were positioned to end at the proximal endarterectomy endpoint, without crossing the inguinal ligament. Technical success, hemodynamic success, and clinical success were determined according to Society of Vascular Surgery/International Society of Cardiovascular Surgery criteria. Life-table analysis was performed for patency. RESULTS: Thirty-four patients (mean age, 68 years; 23 male, 11 female) had combined endovascular and open treatment of iliofemoral occlusive disease. Indications were claudication in 41% and critical limb ischemia in 59%. Femoral reconstruction included endarterectomy with patch angioplasty in all patients. EIA stent deployment incorporated the stenotic iliac segment and the proximal endpoint of the endarterectomy in all patients. Four patients (12%) also needed common iliac angioplasty at the same time for proximal iliac disease, and 14 patients (41%) also needed distal revascularization for associated femoropopliteal or tibial disease. Technical success and hemodynamic success were achieved in 100% of patients. Clinical success was achieved in 97% of patients. The mean postoperative increase in ankle-brachial index in patients with inflow procedures only was 0.36 (range, 0.1 to 0.85). The overall complication rate was 15%. With a mean follow-up period of 13 months (range, 0.5 to 28 months), 1-year primary patency and primary-assisted patency rates were 84% and 97%, respectively. No perioperative mortality was seen. CONCLUSION: EIA stenting as an adjunct to CFA endarterectomy/patch angioplasty allows for more localized surgery than conventional bypass. This approach also allows a better interface between the stent and endarterectomy than staged preoperative stenting. Technical success and early patency rates are excellent.

Aged↗

Prediction of early graft failure with intraoperative completion duplex ultrasound scan.

PURPOSE: The purpose of this study was to determine intraoperative hemodynamic parameters that predict early failure of infragenicular vein grafts with intraoperative completion duplex ultrasound scan. METHODS: We reviewed the results of intraoperative duplex scans that were selectively performed after completion of 45 tibial/pedal vein bypass grafts at high risk for failure. Bypass was performed for rest pain (39%) or tissue loss (61%), and 60% of the cases were disadvantaged because of compromised vein quality or poor arterial outflow. A 10-MHz low-profile transducer was used to scan the entire graft at bypass completion. All grafts were determined to be technically adequate (absence of retained valves, arteriovenous fistulas, or localized velocity increases and the presence of bypass-dependent distal pulses). Peak systolic velocity (PSV) and end diastolic velocity (EDV) were also measured at each anastomosis, in the outflow artery and in the proximal and distal portions of each graft. Resistive indices (RI) were calculated at each measurement point (PSV-EDV/PSV). Statistical analysis was performed with unpaired t test, chi(2) test, and multivariate analyses. RESULTS: Twenty infragenicular vein bypass grafts (44%) thrombosed within 12 months. Intraoperative hemodynamic parameters were significantly different between grafts that remained patent or thrombosed. EDV was lower (5 +/- 1 cm/s versus 13 +/- 3 cm/s; P =.02) and RI was higher (0.90 versus 0.81; P <.01) in the proximal portions of grafts that thrombosed within 12 months. Distal EDV was also lower (6 +/- 1 cm/s versus 15 +/- 2 cm/s; P <.01) and distal RI was higher (0.89 versus 0.78; P <.01) in grafts that thrombosed. With multivariate analysis, only low distal EDV was predictive of early graft failure (P <.05). Distal bypass EDV of less than 8 cm/s predicated early graft thrombosis with 76% sensitivity and 75% specificity (positive predictive value, 71%; negative predictive value, 78%). Absence of diastolic flow (EDV of 0 cm/s) predicted early graft failure with 100% specificity and 100% positive predictive value. CONCLUSION: In this initial experience, low EDV measured with intraoperative duplex scan was associated with early thrombosis of tibial level vein grafts. When such values are observed, measures should be taken to improve graft hemodynamic parameters. Prospective study of infragenicular vein bypass grafts may better define hemodynamic parameters predictive of early graft thrombosis.

Aged↗

Internal iliac occlusion without coil embolization during endovascular abdominal aortic aneurysm repair.

PURPOSE: When abdominal aortic aneurysms and common iliac artery (CIA) aneurysms undergo concomitant endovascular repair, endograft limb extension into the external iliac artery is often necessary. Usually, the internal iliac artery (IIA) is coil embolized in such a case to prevent endoleak. It has been our practice to coil embolize the IIA only in cases where there is not adequate stent graft seal in the CIA immediately proximal to the IIA origin (effectively sealing the entire IIA origin). In this study, we evaluated the outcomes of this approach. METHODS: We retrospectively reviewed 204 consecutive endovascular abdominal aortic aneurysm repairs at Dartmouth-Hitchcock Medical Center from 1996 to 2001. Computed tomographic angiography with three-dimensional reconstruction was the primary preoperative imaging modality, and the decision to cover the IIA without concomitant coil embolization was based before surgery on the presence of adequate graft oversizing (> or =10% to 15%) in the most distal 5 mm of CIA and 15 mm of proximal external iliac artery, respectively. RESULTS: The IIA was occluded 33 times in 31 patients. In 22 cases (67%), the IIA was covered without coil embolization (COVER group). The remaining 11 patients (33%) with inadequate graft oversizing in the CIA underwent IIA coil embolization (COIL group). The follow-up periods for the COVER and COIL groups were 19 +/- 2 months and 10 +/- 3 months, respectively. All operations in both groups were technically successful without evidence of endoleak at completion angiography. No endoleaks, graft migrations, or aneurysm enlargements were associated with the covered or coiled IIAs during the follow-up period. No clinical sequelae were seen in the COVER group, with the exception of buttock claudication in six patients (27%) that resolved completely in five patients. In the COIL group, five patients (45%) had buttock claudication. In addition, one case of buttock necrosis and one case of ischemic neuropathy occurred in the COIL group. CONCLUSION: Covering the IIA without coiling effectively excluded the CIA aneurysm in every case and was associated with a low incidence rate of complications compared with coil embolization. With detailed preoperative imaging and patient selection, IIA coil embolization may not be necessary in as many as two thirds of patients who need IIA occlusion.

Aged↗

Life expectancy after endovascular versus open abdominal aortic aneurysm repair: results of a decision analysis model on the basis of data from EUROSTAR.

BACKGROUND/OBJECTIVES: Although endovascular abdominal aortic aneurysm (AAA) repair (ENDO) has decreased operative morbidity risks compared with open AAA repair (OPEN), risks of rupture and reintervention are higher after ENDO. We used decision analysis to examine the effect of these competing risks on quality-adjusted life expectancy (QALE) after ENDO and OPEN. METHODS: We used a Markov decision-analysis model to simulate hypothetic cohorts of patients undergoing ENDO or OPEN. Patients moved through a multistate transition model according to probabilities derived from the literature, the EUROSTAR database (for ENDO) and Medicare claims data (for OPEN). Our primary outcome measure was QALE after surgery. We used sensitivity analysis to determine which factors most influenced this outcome. RESULTS: In the base-case analysis of 70-year-old men, life expectancy after ENDO was 7.09 quality-adjusted life years compared with 7.03 quality-adjusted life years for OPEN, a difference of 3 weeks. Sensitivity analysis showed that at less than age 64 years, OPEN results in greater QALE. However, the difference in QALE was small (<3 months) across the entire range of ages studied (60 to 85 years). The optimal strategy was sensitive to changes in ENDO and OPEN operative mortality rate, rupture rate after ENDO, late conversion to OPEN rate, ENDO revision rate, and OPEN reoperation rate. However, the difference between OPEN and ENDO strategies was small across the plausible range of most of these variables. CONCLUSION: For most patients who are candidates for AAA repair, ENDO and OPEN result in similar QALE. Decision analysis suggests that OPEN may be preferred for younger patients with low operative risk and ENDO may be preferred for older patients with higher operative risk. However, given the similarity in overall outcome, patient preference should be weighed heavily in decision making.

Aged↗

Open surgical repair versus endovascular therapy for chronic lower-extremity occlusive disease.

Chronic lower-extremity occlusive disease is most often manifested by mild symptoms of claudication that can be managed conservatively. When conservative therapy fails, endovascular procedures may be effective, particularly if the disease extent is minimal. Surgery may be considered for selected patients with claudication who fail endovascular therapy or are not candidates for it. Patients with more severe symptoms of lower-extremity occlusive disease typically have more extensive disease that is treated best with surgery or with a combination of surgery and endovascular therapy. Occasionally, endovascular procedures are performed on patients with more extensive disease who are poor candidates for traditional open surgery because of severe comorbidity. Further advances in endovascular technology may improve patency after endovascular procedures in these patients.

Angioplasty, Balloon↗