Search PubMed⌕ Search

Biomedical subjects

Manabu Tokeshi

Publications and source records attributed to Manabu Tokeshi.

35 records · Page 2Linked to original sources

Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection.

This paper presents a capillary-to-microchip connection, which can be used as an interface for coupling capillary electrophoresis (CE) with a thermal lens microscope (TLM). It is difficult to directly apply TLM to samples in a capillary with a curved surface, and such an interface chip at the end of a CE separation column is needed for reliable TLM measurements. The dependence of the TLM signal intensity on the TLM detection point in the interface chip and the dependence of the theoretical plate number of CE separation on the channel dimensions of the interface chip were investigated and optimized with a mixture of 4-dimethylaminoazobenze-4'-sulfonyl (DABSYL)-derivatized amino acids (glycine, alanine, methionine, and proline) as a model sample. By using an optimized interface chip, theoretical plate numbers of DABSYL-glycine, -methionine, -alanine, and -proline were obtained to be 104000, 95000, 104000, and 95000, respectively.

Amino Acids↗

Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection.

A microchip-based enzyme-linked immunosorbent assay (microELISA) system was developed and interferon-gamma was successfully determined. The system was composed of a microchip with a Y-shaped microchannel and a dam structure, polystyrene microbeads, and a thermal lens microscope (TLM). All reactions required for the immunoassay were done in the microchannel by successive introduction of a sample and regents. The enzyme reaction product, in a liquid phase, was detected downstream in the channel using the TLM as substrate solution was injected. The antigen-antibody reaction time was shortened by the microchip integration. The limit of the determination was improved by adopting the enzyme label. Moreover, detection procedures were greatly simplified and required time for the detection was significantly cut. The system has good potential to be developed as a small and automated high throughput analyzer.

Enzyme-Linked Immunosorbent Assay↗

Micro wet analysis system using multi-phase laminar flows in three-dimensional microchannel network.

A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.

Glass↗

Spectroscopic analysis of liquid/liquid interfaces in multiphase microflows.

Microscopic quasi-elastic laser scattering (muQELS) spectroscopy has been developed for analysis of interfacial phenomena at laminar multiphase microflow in a microchannel. Transport phenomena of a metal chelate through a water/toluene interface were measured, and transient adsorption of the chelate in the initial step of the transport was measured. A water/methanol miscible interface was also measured, and the interfacial free energy of a miscible interface was determined for the first time. The muQELS is expected to be very effective not only for physicochemical investigations of transport and mixing, but also for elemental process analysis of heterogeneous reactions.

Journal Article↗

Microchip-based chemical and biochemical analysis systems.

This review focuses on chemical and biochemical analysis systems using pressure-driven microfluidic devices or microchips. Liquid microspace in a microchip has several characteristic features, for example, short diffusion distances, high specific interfacial area and small heat capacity. These characteristics are the key to controlling micro unit operations and constructing new integrated chemical systems. By combining multiphase laminar flow and the micro unit operations, such as mixing, reaction, extraction and separation, continuous flow chemical processing systems are realized in the microchip format. By applying these concepts, several different analysis systems were successfully integrated on a microchip. In this paper, we introduce the microchip-based chemical systems for wet analysis of cobalt ion, multi-ion sensors, immunoassay, and cellular analysis.

Animals↗

Microchannel-assisted thermal-lens spectrometry for microchip analysis.

Microchannel-assisted thermal lens spectrometry (MATLS) was developed for microchip analysis. This method utilized a photothermal effect in a very small space and rapid thermal conduction between a solid-liquid interface to produce a temperature gradient in the microchannel. In order to examine the mechanism experimentally, we constructed a detection system of laser defocus setup in which an excitation beam was not tightly focused, but it irradiated the microchannel homogeneously. The signal intensity dependence on modulation frequency of excitation and on solvent was investigated with the laser defocusing setup. The results of this investigation indicated that the mechanism of MATLS worked as expected. Since the mechanism of MATLS does not require directivity and coherence of the laser beam, other incoherent lightsources can be used as excitation light for sensitive detections. Finally, we considered some future applications utilizing the mechanism.

Semiconductors↗

Chemicofunctional membrane for integrated chemical processes on a microchip.

Here we report a design and synthesis of a chemically functional polymer membrane by an interfacial polycondensation reaction and multilayer flow inside a microchannel. Single and parallel dual-membrane structures are successfully prepared by using organic/aqueous two-layer flow and organic/aqueous/organic three-layer flow inside the microchannel followed by an interfacial polycondensation reaction. By using the inner-channel membrane, permeation of ammonia species through the inner-channel membrane is successfully achieved. Furthermore, horseradish peroxidase is immobilized on one side of the membrane surface to integrate the chemical transform function onto the inner-channel membrane. Here substrate permeation through the membrane and subsequent chemical transformation at the membrane surface are realized. The polymer membrane prepared inside the microchannel has an important role in ensuring stable contact of different phases such as gas/liquid or liquid/ liquid and the permeation of chemical species through the membrane. Furthermore, membrane surface modification chemistry allows chemical transformation of permeated chemical species. These methods are expected to lead to development of complicated and sophisticated chemical systems involving membrane permeation and chemical reactions.

Journal Article↗

Chemical processing on microchips for analysis, synthesis, and bioassay.

This review describes our recent research on miniaturization of chemical systems. We have developed a miniaturization methodology based on pressure-driven multiphase laminar flow and a highly sensitive detection tool, the thermal lens microscope. Some representative applications of the methodology in the fields of analysis, synthesis, and bioassay are described.

Microscopy↗

An interface chip connection between capillary electrophoresis and thermal lens microscope.

A thermal lens microscope (TLM) detection of capillary electrophoresis (CE) utilizing microchip technology was developed. Fused-silica capillaries with an inner diameter of 50 microm were directly connected to a microchannel in a microchip. The detection limit by TLM was estimated as 2.8 x 10(-7) absorbance by measuring pure water. The detection limit of derivatized amino acids determined by CE-TLM was estimated as 2.4 x 10(-8) M, which was 100 times lower than that of conventional absorbance detection.

Amino Acids↗

Integration of chemical and biochemical analysis systems into a glass microchip.

This review focuses on the integration of chemical and biochemical analysis systems into glass microchips for general use. By combining multiphase laminar flow driven by pressure and micro unit operations, such as mixing, reaction, extraction and separation, continuous-flow chemical processing systems can be realized in the microchip format, while the application of electrophoresis-based chip technology is limited. The performances of several analysis systems were greatly improved by microchip integration because of some characteristics of microspace, i.e., a large specific interface area, a short molecular diffusion time, a small heat capacity and so on. By applying these concepts, several different analysis systems, i.e., wet analysis of cobalt ion, multi-ion sensor, immunoassay, and cellular analysis, were successfully integrated on a microchip. These microchip technologies are promising for meeting the future demands of high-throughput chemical processing.

Biosensing Techniques↗

Nanochannels on a fused-silica microchip and liquid properties investigation by time-resolved fluorescence measurements.

We have fabricated nanometer-sized channels, demonstrated a technique for the introduction of liquid into the channels, and carried out time-resolved fluorescence measurements of aqueous solutions. In this study, 330-nm- and 850-nm-sized channels were fabricated on fused-silica substrates by fast atom beam etching and hydrofluoric acid bonding methods. A liquid introduction method utilizing capillary action was demonstrated. The liquid introduction was observed under an optical microscope, and the liquid velocity during the introduction was analyzed by surface energy and macroscale hydrodynamics. The liquid velocity due to capillary action in the nanometer-sized channel seemed more than four times slower than the estimation. Then, aqueous solutions of rhodamine 6G (R6G), sulforhodamine 101 (SR101), and rhodamine B (RB) in the channels were measured by time-resolved fluorescence spectroscopy; spectra of the same solution in a 250-microm-sized channel were also measured as a reference for the macrospace. Although the fluorescence spectra in the 330-nm-, 850-nm- and 250-microm-sized channels agreed with one another, the fluorescent decays in the nanometer-sized channels were faster for R6G and SR101 and slower for RB than the respective decays in the 250-microm-sized channels. The results suggested the solutions had lower dielectric constants and higher viscosities in the nanometer-sized channels.

Journal Article↗

Glass microchip with three-dimensional microchannel network for 2 x 2 parallel synthesis.

An integrated multireactor system for 2 x 2 parallel organic synthesis has been developed on a single glass microchip. Three-dimensional channel circuits in the chip were fabricated by laminating three glass plate layers. The fabrication method is a straightforward extension of the conventional one, and topological equivalence for any three-dimensional circuits can be constructed easily with it. 2 x 2 phase-transfer amide formation reactions, which constitute a simple model for combinatorial synthesis, were successfully carried out on the microchip, and the integrity of the three-dimensional circuits was confirmed. Combinatorial chemistry with multi-microreactors, in conjunction with a high-throughput screening method based on micro-TAS technologies, is expected to provide an efficient tool for drug discovery.

Journal Article↗

Pile-up glass microreactor.

We made a 'pile-up' microreactor in which ten levels of microchannel circuits were integrated to form a single glass entity. Solutions were distributed to each layer via cylindrical holes with a diameter much larger than that of the microchannel. Fabrication of the pile-up reactor was completed using only conventional photolithography, wet etching and thermal bonding techniques, and no special facilities or instruments were required. An amide formation reaction between amine in aqueous solution and acid chloride in organic solution was carried out using the pile-up reactor. The yield of the amide formation reaction is dependent on the size of the specific surface area between the two solutions, and the small space inside the microchannels is good for acquiring a large specific surface area without any stirring processes. The maximum throughput for the ten-layered pile-up reactor was ten times larger than that of a single-layered one, yet the reaction yield was still high. Productivity of the pile-up reactor for the reaction was as high as on a gram per hour scale. This value suggests that many conventional plants producing fine chemicals can be replaced by microreactors through the numbering-up technology.

Journal Article↗

Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels.

We demonstrated a liquid/liquid and a gas/liquid two-phase crossing flow in glass microchips. A 250-microm-wide microchannel for aqueous-phase flow was fabricated on a top glass plate. Then, as a way to utilize the surface energy difference for stable phase confluence and separation, a 250-microm-wide microchannel for organic-phase (or gas-phase) flow was fabricated on a bottom glass plate and the wall was chemically modified by octadecylsilane (ODS) group. The top and bottom plates were sealed only by pressure. A microchannel pattern was designed so that the two phases made contact at the crossing point of the straight microchannels. The crossing point was observed with an optical microscope. Results showed that the ODS modification of the microchannel wall clearly improved stability of the interface between the two fluids. Pressure difference between fluids was measured and the interface of water and nitrobenzene was stable for the pressure difference from +300 Pa to -200 Pa. The pressure drop in a countercurrent flow configuration was also estimated, and the pressure difference required to realize the counter current flow was less than the allowable pressure range. Finally, we discussed the advantages of utilizing this approach.

Journal Article↗

Single-cell analysis by a scanning thermal lens microscope with a microchip: direct monitoring of cytochrome c distribution during apoptosis process.

We developed a microsystem for cell experiments consisting of a scanning thermal lens microscope detection system and a cell culture microchip. The microchip system was good for liquid control in microspace, and this results in secure cell stimulation and coincident in vivo observation of the cell responses. The system could detect nonfluorescent biological substances with extremely high sensitivity without any labeling materials and had a high spatial resolution of approximately 1 microm. This system was applied to monitoring of cytochrome c distribution in a neuroblastoma-glioma hybrid cell cultured in the microflask (1 mm x 10 mm x 0.1 mm; 1 microL) fabricated in a glass microchip. Cytochrome c release from mitochondria to cytosol during the apoptosis process was successfully monitored with this system. The cytochrome c detected with this system was estimated to be approximately 10 zmol. We concluded that the system was suitable for measuring the distribution of chemical substances in a single cell because the microchip is good for liquid handling in microspace and the thermal lens microscope has high sensitivity and spatial resolution.

Apoptosis↗

Continuous-flow chemical processing on a microchip by combining microunit operations and a multiphase flow network.

A new design and construction methodology for integration of complicated chemical processing on a microchip was proposed. This methodology, continuous-flow chemical processing (CFCP), is based on a combination of microunit operations (MUOs) and a multiphase flow network. Chemical operations in microchannels, such as mixing, reaction, and extraction, were classified into several MUOs. The complete procedure for Co(II) wet analysis, including a chelating reaction, solvent extraction, and purification was decomposed into MUOs and reconstructed as CFCP on a microchip. Chemical reaction and molecular transport were realized in and between continuous liquid flows in a multiphase flow network, such as aqueous/aqueous, aqueous/organic, and aqueous/organic/aqueous flows. When the determination of Co(II) in an admixture of Cu(II) was carried out using this methodology, the determination limit (2sigma) was obtained as 18 nM, and the absolute amount of Co chelates detected was 0.13 zmol, that is, 78 chelates. The sample analysis time was faster than that of a conventional processing system. Moreover, troublesome operations such as phase separation and acid and alkali washing, all necessary for the conventional system, were simplified. The CFCP methodology proposed here can be applied to various on-chip applications.

Journal Article↗

Microchip-based immunoassay system with branching multichannels for simultaneous determination of interferon-gamma.

A bead-bed immunoassay system suitable for simultaneous assay of multiple samples was constructed on a microchip. The chip had branching multichannels and four reaction and detection regions; the constructed system could process four samples at a time with only one pump unit. Interferon gamma was assayed by a 3-step sandwich immunoassay with the system coupled to a thermal lens microscope as a detector. The biases of the signal intensities obtained from each channel were within 10%, and coefficients of variation were almost the same level as the single straight channel assay. The assay time for four samples was 50 min instead of 35 min for one sample in the single-channel assay; hence higher throughput was realized with the branching structure chip.

Animals↗