Search PubMed⌕ Search

Biomedical subjects

Magnus Gustafsson

Publications and source records attributed to Magnus Gustafsson.

13 recordsLinked to original sources

Observing the stereodynamics of chemical reactions using randomly oriented molecular beams.

A new method is demonstrated to study the stereodynamics of simple chemical reactions that does not require the use of oriented (or aligned) molecular beams or measurements of the orientation state of product molecules. Instead, it is shown that by numerically combining accurate measurements of the state-to-state differential cross section for two or more rotational states of the reagent molecule, the separate contribution from the individual helicity states can be extracted. New molecular beam experiments are conducted for the D+H(2)-->HD+H reaction that confirm the validity of the method.

Journal Article↗

The state-to-state-to-state model for direct chemical reactions: application to D+H2-->HD+H.

A simple theoretical model is developed to predict the state-to-state dynamics of direct chemical reactions. Motivated by traditional ideas from transition state theory, expressions are derived for the reactive S matrix that may be computed using the local transition state dynamics. The key approximation involves the use of quantum bottleneck states to represent the near separable dynamics taking place near the transition state. Explicit expressions for the S matrix are obtained using a Franck-Condon treatment for the inelastic coupling between internal states of the collision complex. It is demonstrated that the energetic thresholds for various initial reagent states of the D+H(2) reaction can be understood in terms of our theory. Specifically, the helicity of the reagent states are found to correlate directly to the symmetry of the quantum bottleneck states, which thus possess very different thresholds. Furthermore, the rotational product state distributions for D+H(2) are found to be associated with interfering pathways through the quantum bottleneck states.

Journal Article↗

Observation of Feshbach resonances in the F + H2 --> HF + H reaction.

Reaction resonances, or transiently stabilized transition-state structures, have proven highly challenging to capture experimentally. Here, we used the highly sensitive H atom Rydberg tagging time-of-flight method to conduct a crossed molecular beam scattering study of the F + H2 --> HF + H reaction with full quantum-state resolution. Pronounced forward-scattered HF products in the v' = 2 vibrational state were clearly observed at a collision energy of 0.52 kcal/mol; this was attributed to both the ground and the first excited Feshbach resonances trapped in the peculiar HF(v' = 3)-H' vibrationally adiabatic potential, with substantial enhancement by constructive interference between the two resonances.

Electrons↗

State to state to state dynamics of the D+H2 -->HD+H reaction: control of transition-state pathways via reagent orientation.

The influence of reagent rotation on the dynamics of the D+H2 -->HD+H reaction is studied. The state-resolved differential cross section is measured using the Rydberg-atom scheme in a crossed beam experiment. It is found that the H2 rotation has a strong influence on the results. This effect was traced to the selection of the quantum bottleneck states through reagent orientation, thus suggesting a novel strategy to control the transition-state pathways in direct chemical reactions.

Journal Article↗

Microfluidic analysis of antibody specificity in a compact disk format.

A new and flexible technology for high throughput analysis of antibody specificity and affinity is presented. The method is based on microfluidics and takes advantage of compact disks (CDs) in which the centrifugal force moves fluids through microstructures containing immobilized metal affinity chromatography columns. Analyses are performed as a sandwich assay, where antigen is captured to the column via a genetically attached His6-tag. The antibodies to be analyzed are applied onto the columns. Thereafter, fluorescently labeled secondary antibodies recognize the bound primary antibodies, and detection is carried out by laser-induced fluorescence. The CDs contain 104 microstructures enabling analysis of antibodies against more than 100 different proteins using a single CD. Importantly, through the three-dimensional visualization of the binding patterns in a column it is possible to separate high affinity from low affinity binding. The method presented here is shown to be very sensitive, flexible and reproducible.

Animals↗

Comparison of different IMAC techniques used for enrichment of phosphorylated peptides.

Four commercially available immobilized metal ion affinity chromatography (IMAC) methods for phosphopeptide enrichment were compared using small volumes and concentrations of phosphopeptide mixtures with or without extra-added bovine serum albumin (BSA) nonphosphorylated peptides. Addition of abundant tryptic BSA peptides to the phosphopeptide mixture increases the demand for selective IMAC capture. While SwellGel gallium Discs, IPAC Metal Chelating Resin, and ZipTipMC Pipette Tips allow for the possibility of enriching phosphopeptides, the Gyrolab MALDI IMAC1 also presents the possibility of verifying existing phosphopeptides after a dephosphorylation step. Phosphate-containing peptides are identified through a mass shift between phosphorylated and dephosphorylated spectra of 80 Da (or multiples of 80 Da). This verification is useful if the degree of phosphorylation is low in the sample or if the ionization is unfavorable, which often is the case for phosphopeptides. A peptide mixture in which phosphorylated serine, threonine, and tyrosine were represented was diluted in steps and thereafter enriched using the four different IMAC methods prior to analyses with matrix assisted laser desorption/ionization mass spectrometry. The enrichment of phosphopeptides using SwellGel Gallium Discs or Gyrolab MALDI IMAC1 was not significantly affected by the addition of abundant BSA peptides added to the sample mixture, and the achieved detection limits using these techniques were also the lowest. All four of the included phosphopeptides were detected by MALDI-MS only after enrichment using the Gyrolab MALDI IMAC1 compact disc (CD) and detection down to low femtomole levels was possible. Furthermore, selectivity, reproducibility, and detection for a number of other phosphopeptides using the IMAC CD are reported herein. For example, two phosphopeptides sent out in a worldwide survey performed by the Proteomics Research Group (PRG03) of the Association of Biomolecular Resource Facilities (ABRF) were detected and verified by means of the 80 Da mass shift achieved by on-column dephosphorylation.

Animals↗

Detection of phosphorylated peptides in proteomic analyses using microfluidic compact disk technology.

A compact disk (CD)-based microfluidic method for selective detection of phosphopeptides by mass spectrometry is described. It combines immobilized metal affinity chromatography (IMAC) and enzymatic dephosphorylation. Phosphoproteins are digested with trypsin and processed on the CD using nanoliter scale IMAC with and without subsequent in situ alkaline phosphatase treatment. This is followed by on-CD matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Dephosphorylation of the IMAC-enriched peptides allows selective phosphopeptide detection based on the differential mass maps generated (mass shifts of 80 Da or multiples of 80 Da). The CD contains 96 microstructures, each with a 16 nL IMAC microfluidic column. Movement of liquid is controlled by differential spinning of the disk. Up to 48 samples are distributed onto the CD in two equal sets. One set is for phosphopeptide enrichment only, the other for identical phosphopeptide enrichment but combined with in situ dephosphorylation. Peptides are eluted from the columns directly into MALDI target areas, still on the CD, using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into a MALDI mass spectrometer for analysis down to the femtomole level. The average success rate in phosphopeptide detection is over 90%. Applied to noncharacterized samples, the method identified two novel phosphorylation sites, Thr 735 and Ser 737, in the ligand-binding domain of the human mineralocorticoid receptor.

Alkaline Phosphatase↗

Far-infrared absorption by collisionally interacting nitrogen and methane molecules.

Quantum line shape calculations of the rototranslational enhancement spectra of nitrogen-methane gaseous mixtures are reported. The calculations are based on a recent theoretical dipole function for interacting N(2) and CH(4) molecules, which accounts for the long-range induction mechanisms: multipolar inductions and dispersion force-induced dipoles. Multipolar induction alone was often found to approximate the actual dipole surfaces of pairs of interacting linear molecules reasonably well. However, in the case of the N(2)-CH(4) pair, the absorption spectra calculated with such a dipole function still show a substantial intensity defect at the high frequencies (>250 cm(-1)) when compared to existing measurements at temperatures from 126 to 297 K, much as was previously reported.

Journal Article↗

Integrated sample preparation and MALDI mass spectrometry on a microfluidic compact disk.

High-throughput microfluidic processing of protein digests integrated with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry on a compact disk (CD) is described. Centrifugal force moves liquid through multiple microstructures, each containing a 10-nL reversed-phase chromatography column. The CD enables parallel preparation of 96 samples with volumes ranging from one to several microliters. The peptides in the digests are concentrated, desalted, and subsequently eluted from the columns directly into MALDI target areas (200 x 400 microm) on the CD using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into the MALDI instrument for peptide mass fingerprinting and database identification at a routine sensitivity down to the 200-amol level. Detection of proteolytic peptides down to the 50-amol level is demonstrated. The success rate of the CD technology in protein identification is about twice that of the C(18) ZipTips and standard MALDI steel targets. The CDs are operated using robotics to transfer samples and reagents from microcontainers to the processing inlets on the disposable CD and spinning to control the movement of liquid through the microstructures.

Journal Article↗

Identification of endothelial proteins by MALDI-MS using a compact disc microfluidic system.

Vascular endothelial proteins have been analyzed using two-dimensional (2D) gel electrophoresis and subsequent mass spectrometry, with separate methods for the intervening sample preparations. Compact disc (CD) technology was found to be rapid, giving high overall yield both with ordinary Coomassie staining and with Sypro Ruby staining. Combined with automatic in-gel digestion, the CD technology has great capacity for large numbers of protein analysis, although for limited sample numbers, manual methods can give similar sequence coverage. In a test set of 48 samples, 45 proteins were identified using the CD preparation technique, 32 identified with higher sequence coverage using the CD technique, 7 with higher using ZipTips in a robotic workstation, and 5 with higher coverage using dried droplets of unpurified samples. In the process of these methodological comparisons, basic patterns for 116 endothelial proteins were defined, representing 297 separate protein spots on the 2D gels.

Compact Disks↗