Search PubMed⌕ Search

Biomedical subjects

Maciej Zborowski

Publications and source records attributed to Maciej Zborowski.

26 records · Page 2Linked to original sources

Bone mass is preserved in a critical-sized osteotomy by low energy pulsed electromagnetic fields as quantitated by in vivo micro-computed tomography.

The effectiveness of non-invasive pulsed electromagnetic fields (PEMF) on stimulating bone formation in vivo to augment fracture healing is still controversial, largely because of technical ambiguities in data interpretation within several previous studies. To address this uncertainty, we implemented a rigorously controlled, blinded protocol using a bilateral, mid-diaphyseal fibular osteotomy model in aged rats that achieved a non-union status within 3-4 weeks post-surgery. Bilateral osteotomies allowed delivery of a PEMF treatment protocol on one hind limb, with the contralateral limb representing a within-animal sham-treatment. Bone volumes in both PEMF-treated and sham-treated fibulae were assessed simultaneously in vivo using highly sensitive, high-resolution micro-computed tomography (microCT) over the course of treatment. We found a significant reduction in the amount of time-dependent bone volume loss in PEMF-treated, distal fibular segments as compared to their contralateral sham-treated bones. Osteotomy gap size was significantly smaller in hind limbs exposed to PEMF over sham-treatment. Therefore, our data demonstrate measurable biological consequences of PEMF exposure on in vivo bone tissue.

Animals↗

Magnetic cell separation: characterization of magnetophoretic mobility.

Magnetic cell separation has become a popular technique to enrich or deplete cells of interest from a heterogeneous cell population. One important aspect of magnetic cell separation is the degree to which a cell binds paramagnetic material. It is this paramagnetic material that imparts a positive magnetophoretic mobility to the target cell, thus allowing effective cell separation. A mathematical relationship has been developed to correlate magnetic labeling to the magnetophoretic mobility of an immunomagnetically labeled cell. Four parameters have been identified that significantly affect magnetophoretic mobility of an immunomagnetically labeled cell: the antibody binding capacity (ABC) of a cell population, the secondary antibody amplification (psi), the particle-magnetic field interaction parameter (DeltachiV(m)), and the cell diameter (D(c)). The ranges of these parameters are calculated and presented along with how the parameters affect the minimum and maximum range of magnetophoretic mobility. A detailed understanding of these parameters allows predictions of cellular magnetophoretic mobilities and provides control of cell mobility through selection of antibodies and magnetic particle conjugates.

Antigen-Antibody Reactions↗

Splitter imperfections in annular split-flow thin separation channels: experimental study of nonspecific crossover.

The separation performance of a split-flow thin (SPLITT) separation device depends on uniformity of channel thickness and the precise placement of the flow splitters at fixed distances between the channel walls. The observation of nonspecific crossover, that is, the transport of sample materials across the channel thickness without the influence of an applied field, has routinely been taken to indicate the presence of irregularities in splitter shape or placement. Computational fluid dynamics software may be used to predict the influence of splitter imperfections on nonspecific crossover, where it is assumed that sample transport is by convection alone. A previous study has shown how small inlet splitter imperfections can account for the relatively low levels of nonspecific crossover observed with typical annular SPLITT devices. This study, however, could not distinguish between the possible sources of nonspecific crossover; hydrodynamic lift or shear-induced diffusion could have contributed. To confirm the validity of the computational approach, a series of experiments has been carried out on a channel having a deliberately and severely bent splitter. Nonspecific crossover was measured for a range of inlet and outlet flow rate ratios, with the bent splitter placed at both the channel inlet and outlet. The severity of the splitter distortion was sufficient to produce significant nonspecific crossover over a wide range of flow conditions. Good agreement was found between experiment and prediction based on computational fluid dynamics, with experiment generally showing only slightly higher crossover than prediction. The quantitative agreement for this extreme case suggests that the contribution to nonspecific crossover due to geometrical imperfections can be well described using computational fluid dynamics.

Chemical Fractionation↗

Characterization of antibody binding to three cancer-related antigens using flow cytometry and cell tracking velocimetry.

Proper antibody labeling is a fundamental step in the positive selection/isolation of rare cancer cells using immunomagnetic cell separation technology. Using either a two-step or single-step labeling protocol, we examined a combination of six different antibodies specific for three different antigens (epithelial specific antigen, epithelial membrane antigen, and HER-2/Neu) on two different breast cancer cell lines (HCC1954 and MCF-7). When a two-step labeling protocol was used (i.e., anti-surface marker-fluoroscein-isothiocyanate [FITC] [primary Ab], anti-FITC magnetic colloid [secondary Ab]) saturation of the primary antibody was determined using fluorescence intensity measurements from flow cytometry (FCM). The saturation of the secondary antibody (or saturation of a single-step labeling) was determined using magnetophoretic mobility measurements from cell tracking velocimetry (CTV). When the maximum magnetophoretic mobility was the primary objective, our results demonstrate that the quantities necessary for antibody saturation with respect to fluorescence intensity were generally higher than those recommended by the manufacturer. The results demonstrate that magnetophoretic mobility varies depending on the types of cell lines, primary antibodies, and concentration of secondary magnetic colloid-conjugated antibody. It is concluded that saturation studies are a vital preparatory step in any separation method involving antibody labeling, especially those that require the specificity of rare cell detection.

Antigen-Antibody Reactions↗

Splitter imperfections in annular split-flow thin separation channels: effect on nonspecific crossover.

The separation performance of split-flow thin (SPLITT) separation channels generally falls short of ideal behavior. There are many possible contributing factors to the loss of separation resolution, and these are discussed in the text. The possibility that small imperfections in the splitters play a significant role is examined in this study. Computational fluid dynamics is used to determine the flow pattern within an annular SPLITT channel having small imperfections in the inlet splitter. These results are used to calculate the nonspecific crossover of particles from the inner annular inlet to the outer annular outlet under various flow rate regimes. Nonspecific crossover, obtained through convective transport alone, and not the result of field-induced transport, is often used as a check of channel behavior. The results of a typical experimental determination of nonspecific crossover are included for comparison. It is concluded that geometrical imperfections can indeed play a significant role in the loss of resolution observed for these systems.

Cell Separation↗

Red blood cell magnetophoresis.

The existence of unpaired electrons in the four heme groups of deoxy and methemoglobin (metHb) gives these species paramagnetic properties as contrasted to the diamagnetic character of oxyhemoglobin. Based on the measured magnetic moments of hemoglobin and its compounds, and on the relatively high hemoglobin concentration of human erythrocytes, we hypothesized that differential migration of these cells was possible if exposed to a high magnetic field. With the development of a new technology, cell tracking velocimetry, we were able to measure the migration velocity of deoxygenated and metHb-containing erythrocytes, exposed to a mean magnetic field of 1.40 T and a mean gradient of 0.131 T/mm, in a process we call cell magnetophoresis. Our results show a similar magnetophoretic mobility of 3.86 x 10(-6) mm(3) s/kg for erythrocytes with 100% deoxygenated hemoglobin and 3.66 x 10(-6) mm(3) s/kg for erythrocytes containing 100% metHb. Oxygenated erythrocytes had a magnetophoretic mobility of from -0.2 x 10(-6) mm(3) s/kg to +0.30 x 10(-6) mm(3) s/kg, indicating a significant diamagnetic component relative to the suspension medium, in agreement with previous studies on the hemoglobin magnetic susceptibility. Magnetophoresis may open up an approach to characterize and separate cells for biochemical analysis based on intrinsic and extrinsic magnetic properties of biological macromolecules.

Cell Movement↗

Magnetic field visualization in applications to pulsed electromagnetic field stimulation of tissues.

Electromagnetic field visualization is important in multidisciplinary research on the molecular basis of therapeutic effects of pulsed electromagnetic fields (PEMF). We have compared classic PEMF representations by two-dimensional field lines and field magnitude contour plots with a field representation using three-dimensional field isosurfaces. Field simulations were performed for a clinically approved Spinal-Stim Lite system (Orthofix Inc., McKinney, TX). The relatively simple coil system geometry and the predominantly dielectric properties of the surrounding medium (air and human connective tissue) allowed us to develop analytical expressions for the field. The field model was validated by comparison with experimentally measured field values, and with values calculated using a commercial finite-element analysis software package. Two-dimensional field representations by field lines and field contour plots were less intuitive than three-dimensional field isosurface representations to members of the group without an engineering background. Field isosurfaces, represented as three-dimensional solids, allowed for direct visualization of PEMF targeting of individual organs (lumbar spine), the extent of the therapeutic field value, and the directional field characteristics. The dynamic characteristic of the field was well illustrated by a sequence of field isosurfaces corresponding to the evolution with time of the electric current waveform (sawtooth) powering the coils. The isosurface representation of the field can be extended to any three-dimensional coil system geometry using plotting capabilities of current computer algebra software packages.

Computer Simulation↗

Magnetophoretic cell sorting is a function of antibody binding capacity.

Antibody binding capacity (ABC) is a term representing a cell's ability to bind antibodies, correlating with the number of specific cellular antigens expressed on that cell. ABC allows magnetically conjugated antibodies to bind to the targeted cells, imparting a magnetophoretic mobility on each targeted cell. This enables sorting based on differences in the cell magnetophoretic mobility and, potentially, a magnetic separation based on the differences in the cell ABC values. A cell's ABC value is a particularly important factor in continuous magnetic cell separation. This work investigates the relationship between ABC and magnetic cell separation efficiency by injection of a suspension of immunomagnetically labeled quantum simply cellular calibration microbeads of known ABC values into fluid flowing through a quadrupole magnetic sorter. The elution profiles of the outlet streams were evaluated using UV detectors. Optimal separation flow rate was shown to correlate with the ABC of these microbeads. Comparing experimental and theoretical results, the theory correctly predicted maximum separation flow rates but overestimated the separation fractional recoveries.

Antibody Affinity↗