Search PubMed⌕ Search

Biomedical subjects

M Zankl

Publications and source records attributed to M Zankl.

At least 19 recordsLinked to original sources

Human exposure to space radiation: role of primary and secondary particles.

Human exposure to space radiation implies two kinds of risk, both stochastic and deterministic. Shielding optimisation therefore represents a crucial goal for long-term missions, especially in deep space. In this context, the use of radiation transport codes coupled with anthropomorphic phantoms allows to simulate typical radiation exposures for astronauts behind different shielding, and to calculate doses to different organs. In this work, the FLUKA Monte Carlo code and two phantoms, a mathematical model and a voxel model, were used, taking the Galactic Cosmic Rays (GCR) spectra from the model of Badhwar and O'Neill. The time integral spectral proton fluence of the August 1972 Solar Particle Event (SPE) was represented by an exponential function. For each aluminium shield thickness, besides total doses the contributions from primary and secondary particles for different organs and tissues were calculated separately. More specifically, organ-averaged absorbed doses, dose equivalents and a form of 'biological dose', defined on the basis of initial (clustered) DNA damage, were calculated. As expected, the SPE doses dramatically decreased with increasing shielding, and doses in internal organs were lower than in skin. The contribution of secondary particles to SPE doses was almost negligible; however it is of note that, at high shielding (10 g cm(-2)), most of the secondaries are neutrons. GCR organ doses remained roughly constant with increasing Al shielding. In contrast to SPE results, for the case of cosmic rays, secondary particles accounted for a significant fraction of the total dose.

Astronauts↗

Pitfalls and modelling inconsistencies in computational radiation dosimetry: lessons learnt from the QUADOS intercomparison. Part I: Neutrons and uncertainties.

The QUADOS EU cost shared action conducted an intercomparison on the usage of numerical methods in radiation protection and dosimetry. The eight problems proposed were intended to test the usage of Monte Carlo and deterministic methods by assessing the accuracy with which the codes are applied and also the methods used to evaluate uncertainty in the answer gained through these methods. The overall objective was to spread good practice through the community and give users information on how to assess the uncertainties associated with their calculated results.

Bayes Theorem↗

Pitfalls and modelling inconsistencies in computational radiation dosimetry: lessons learnt from the QUADOS intercomparison. Part II: Photons, electrons and protons.

'QUADOS', a concerted action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance to the radiation dosimetry community, five of which involved photon and proton transport. This paper focuses on a discussion of lessons learned from the participation in solving the photon and charged particle problems. The lessons learned from the participation in solving the neutron problems are presented in a companion paper (in this issue).

Angioplasty↗

Average glandular dose conversion coefficients for segmented breast voxel models.

For 8 voxel models of a compressed breast (4-7 cm thickness and two orientations for each thickness) and 14 radiation qualities commonly used in mammography (HVL 0.28-0.50 mm Al), tissue dose conversion coefficients were calculated for a focus-to-film distance of 60 cm using Monte Carlo methods. The voxel models were segmented from a high-resolution (slice thickness of 1 mm) computed tomography data set of an ablated breast specimen fixated while being compressed. The contents of glandular tissues amounted to 2.6%, and were asymmetrically distributed with regard to the midplane of the model. The calculated tissue dose conversion coefficients were compared with the recent literature values. These earlier tissue dose conversion coefficients were also calculated using Monte Carlo methods and breast models of various thickness, but these consist of homogeneous mixtures of glandular and adipose tissues embedded in 5 mm pure adipose tissue both at the entrance and exit sides. The results show that the new glandular tissue dose conversion coefficients agree well with the literature values for those cases where the glandular tissue is predominantly concentrated in the upper part of the model. In the opposite case, they were lower by up to 40%. These findings reveal a basic problem in patient dosimetry for mammography: glandular dose is not only governed by the average breast composition, which could be derived from the breast thickness, but also by the local distribution of glandular tissue within the breast, which is not known.

Air↗

The application of FLUKA to dosimetry and radiation therapy.

The FLUKA Monte Carlo code has been evolving over the last several decades and is now widely used for radiation shielding calculations. In order to facilitate the use of FLUKA in dosimetry and therapy applications, supporting software has been developed to allow the direct conversion of the output files from standard CT-scans directly into a voxel geometry for transport within FLUKA. Since the CT-scan information essentially contains only the electron density information over the scanned volume, one needs the specific compositions for each voxel individually. We present here the results of a simple algorithm to assign tissues in the human body to one of four categories: soft-tissue, hard-bone, trabecular-bone and porous-lung. In addition, we explore the problem of the pathlength distributions in porous media such as trabecular bone. A mechanism will be implemented within FLUKA to allow for variable multipal fixed density materials to accommodate the pathlength distributions discovered.

Algorithms↗

Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources.

This paper aims at comparing dosimetric assessments performed with three Monte Carlo codes: EGS4, MCNP4c2 and MCNPX2.5e, using a realistic voxel phantom, namely the Zubal phantom, in two configurations of exposure. The first one deals with an external irradiation corresponding to the example of a radiological accident. The results are obtained using the EGS4 and the MCNP4c2 codes and expressed in terms of the mean absorbed dose (in Gy per source particle) for brain, lungs, liver and spleen. The second one deals with an internal exposure corresponding to the treatment of a medullary thyroid cancer by 131I-labelled radiopharmaceutical. The results are obtained by EGS4 and MCNPX2.5e and compared in terms of S-values (expressed in mGy per kBq and per hour) for liver, kidney, whole body and thyroid. The results of these two studies are presented and differences between the codes are analysed and discussed.

Computer Simulation↗

QUADOS intercomparison: a summary of photon and charged particle problems.

QUADOS, a Concerted Action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance to the radiation dosimetry community, five of which involved photon and proton transport. This paper focuses on the analysis of the photon and charged particle problems. The neutron problems were presented in a paper at the NEUDOS9 conference.

Algorithms↗

Photon dose conversion coefficients for human teeth in standard irradiation geometries.

Photon dose conversion coefficients for human tooth materials are computed in energy range from 0.01 to 10 MeV by the Monte Carlo method. The voxel phantom "Golem" of the human body with newly defined tooth region and a modified version of the EGS4 code have been used to compute the coefficients for 30 tooth cells with different locations and materials. The dose responses are calculated for cells representing buccal and lingual enamel layers. The computed coefficients demonstrate a strong dependence on energy and geometry of the radiation source and a weaker dependence on location of the enamel voxels. For isotropic and rotational radiation fields, the enamel dose does not show a significant dependence on tooth sample locations. The computed coefficients are used to convert from absorbed dose in teeth to organ dose or to integral air kerma. Examples of integral conversion factors from enamel dose to air kerma are given for several photon fluences specific for the Mayak reprocessing plant in Russia. The integral conversion factors are strongly affected by the energy and angular distributions of photon fluence, which are important characteristics of an exposure scenario for reconstruction of individual occupational doses.

Humans↗

Role of shielding in modulating the effects of solar particle events: Monte Carlo calculation of absorbed dose and DNA complex lesions in different organs.

Distributions of absorbed dose and DNA clustered damage yields in various organs and tissues following the October 1989 solar particle event (SPE) were calculated by coupling the FLUKA Monte Carlo transport code with two anthropomorphic phantoms (a mathematical model and a voxel model), with the main aim of quantifying the role of the shielding features in modulating organ doses. The phantoms, which were assumed to be in deep space, were inserted into a shielding box of variable thickness and material and were irradiated with the proton spectra of the October 1989 event. Average numbers of DNA lesions per cell in different organs were calculated by adopting a technique already tested in previous works, consisting of integrating into "condensed-history" Monte Carlo transport codes--such as FLUKA--yields of radiobiological damage, either calculated with "event-by-event" track structure simulations, or taken from experimental works available in the literature. More specifically, the yields of "Complex Lesions" (or "CL", defined and calculated as a clustered DNA damage in a previous work) per unit dose and DNA mass (CL Gy-1 Da-1) due to the various beam components, including those derived from nuclear interactions with the shielding and the human body, were integrated in FLUKA. This provided spatial distributions of CL/cell yields in different organs, as well as distributions of absorbed doses. The contributions of primary protons and secondary hadrons were calculated separately, and the simulations were repeated for values of Al shielding thickness ranging between 1 and 20 g/cm2. Slight differences were found between the two phantom types. Skin and eye lenses were found to receive larger doses with respect to internal organs; however, shielding was more effective for skin and lenses. Secondary particles arising from nuclear interactions were found to have a minor role, although their relative contribution was found to be larger for the Complex Lesions than for the absorbed dose, due to their higher LET and thus higher biological effectiveness.

Astronauts↗

Intercomparison on the usage of computational codes in radiation dosimetry.

'QUADOS', a Concerted Action of the European Commission, has run an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of Monte Carlo, analytic and semi-analytic codes or deterministic methods. Its main aim was to provide a snapshot of the methods and codes currently in use. It also intended to furnish information on the methods used to assess the reliability of computational results and disseminate 'good practice' throughout the radiation dosimetry community. Eight problems were selected for their relevance to the radiation dosimetry community, three of which involve neutron transport. This paper focuses on the analysis of the neutron problems.

Algorithms↗

Spectra of scattered photons in large absorbers and their importance for the values of radiation weighting factor wR.

In its review of the present values of radiation weighting factor w(R) and of possible revisions of this factor, the German Radiation Protection Commission has recommended to maintain the approach of ICRP 60 to base the selection of the w(R) value for a given radiation (e.g. fission neutrons) on observed values of the relative biological effectiveness (RBE) of this radiation 'regardless of whether the reference radiation is X rays or gamma rays'. The physical background of the German recommendation is the buildup of a strong field of energy-degraded Compton scattered photons in the human body if exposed to an external field of high-energy photons, so that the total radiation field inside the body is a mixture comprising low and high photon energies. Therefore, it is appropriate that the selection of the w(R) value of the given radiation is guided by RBE values averaged over X rays and gamma rays as the reference radiations. In support of this rationale, the present paper provides a sample of Monte Carlo calculated scattered photon spectra in large absorbers exposed to high-energy photons. Depth-dependent fractional dose contributions of the scattered photons are tabulated for incident energies from 1 to 10 MeV, and estimates of the influence of their degraded energies on the biological effectiveness of the incoming radiation are presented. Accordingly, we point out that it is appropriate to use, for the purposes of 'risk projection', RBE values averaged over X and gamma reference radiations.

Environmental Exposure↗

Adult female voxel models of different stature and photon conversion coefficients for radiation protection.

This paper describes the construction of three adult female voxel models, two whole-body and one from head to thighs, from computed tomographic data of 3 women of different stature. Voxel models (also called phantoms) are human models based on computed tomographic or magnetic resonance images obtained from high resolution continuous scans of a single individual. The gray-scale data or information content of the medical images are interpreted into tissues (i.e., organs), a process known as segmentation. The phantoms, consisting of millions of volume elements, called voxels, provide a three-dimensional representation of the human body and the spatial form of its constituent organs and structures. They were initially developed for radiation protection purposes to estimate the organ and effective doses and hence the risk to a person or population due to an irradiation. This paper also presents conversion coefficients for idealized geometries of external photon exposures of energies 10 keV-1 MeV for the three female models, calculated with a Monte Carlo code. Until now there were not any published data on conversion coefficients for explicit female voxel models. Such sets of conversion coefficients exist for voxel adult males or for MIRD-type male, female, and hermaphrodite models. Numerical differences of the calculated conversion coefficients for the voxel female models and MIRD-type models can amount up to 60% or more for external exposures and are due to the improved anatomical realism of the voxel models. The size of the model also has an effect on the conversion coefficients, particularly for deeper lying organs and energies below 200 keV. The three separate sets of conversion coefficients allow one to choose the most suitable model according to the size of the individual as well as to study the dosimetric variations due to the size of the model.

Adult↗

Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.

The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.

Computer Simulation↗

The application of voxel phantoms to the internal dosimetry of radionuclides.

Extensive calculations of specific absorbed fractions (SAFs) for monoenergetic photon sources were performed using a Monte Carlo photon transport code together with seven male and female adult voxel models based on computed tomographic data of real persons. These models offer greater realism with respect to organ topology than the mathematical phantoms commonly used in the past. Due to individual anatomical differences, large variations in photon SAFs between the voxel models were found that can amount to orders of magnitude for very low photon energies. However, in many cases, the larger differences were found between MIRD-type and voxel models, since the inter-organ distances tend to be larger in the MIRD-type phantoms than in reality, due to over-simplification of organ shapes. Furthermore, organ absorbed doses per incorporated activity were evaluated for two selected radiopharmaceuticals. Although a method was found to largely eliminate the influence of organ mass on SAFs for organ self-absorption, the absorbed dose coefficients varied by several tens of per cent between the individual voxel models, thus indicating a significant influence of individual photon SAFs for organ cross-fire on organ absorbed dose. Again, 43% of the MIRD organ dose values were outside the range of doses spanned by the voxel models. Effective dose showed a variation of only up to 26% between the single voxel models for the radiopharmaceuticals considered.

Adult↗

Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation.

There is a need to calculate specific absorbed fractions (SAFs) in voxel phantoms for internal dosimetry. For this purpose, an EGS4 user code for calculating SAFs using voxel phantoms was developed on the basis of an existing EGS4 user code for external dosimetry (UCPIXEL). In the developed code, the transport of photons, electrons and positrons in voxel phantoms can be simulated, particularly the transport simulations of secondary electrons in voxel phantoms. The evaluated SAFs for the GSF 'Child' voxel phantom using the developed code were found to be in good agreement with the GSF evaluated data. In addition, SAFs in adult voxel phantoms developed at JAERI were evaluated using the developed code and were compared with several published data. It was found that SAFs for organ self-absorption depend on the organ masses and would be affected by differences in the structure of the human body.

Absorption↗

Monte Carlo calculation and experimental verification of the photon energy response of tooth enamel in a head-sized plexiglas phantom.

The use of electron paramagnetic resonance (EPR) tooth dosimetry for calculation of organ doses requires conversion of the measured absorbed dose in enamel. Before deriving conversion factors from simulation calculations with a realistic anthropomorphic human phantom, in the current study a simplified phantom was chosen to compare EPR measurement and Monte Carlo calculation. The dose response of tooth enamel of molars at various positions inside a cylindrical Plexiglas phantom of head-size was calculated hy Monte Carlo modelling in parallel photon beams of X rays of 63 keV equivalent energy and 60Co gamma rays (1.25 Mev). For X ray exposure, preliminary results of EPR dosimetry with tooth enamel samples prepared from molars irradiated in the phantom were in agreement with calculation. The mean value of the ratio of the measured to the calculated dose was 0.93 +/- 0.08.

Adult↗

The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.

The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization of a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters. In the present study, chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage (102 kVp and 141 kVp), nominal speed class (160 and 320), maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R=12) and air gap). The air kerma at the entrance surface was measured for all patients and the risk-related dose H(Golem), based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values, was calculated. Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels, density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H(Golem) was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp, an air gap, a screen-film system with speed 320 and an optical density of 1.8.

Adult↗