Search PubMed⌕ Search

Biomedical subjects

M Yoshikawa

Publications and source records attributed to M Yoshikawa.

At least 127 records · Page 7Linked to original sources

Ileal perforation due to a Richter hernia at the drain insertion site following an operation for idiopathic rectal perforation: report of a case.

A case of a Richter hernia at the insertion site of the drainage tube following open abdominal surgery is reported. A 54-year-old man underwent an emergency operation for an idiopathic rectal perforation. A partial resection of the rectum and drainage using four 10-mm (outer diameter) drainage tubes with round cross sections was performed. Despite an uneventful early postoperative course, an emergency reoperation was required for peritonitis due to a bowel perforation 14 days after removing the drain inserted into the rectosacral space. A laparotomy revealed an incarcerated Richter hernia with ileal perforation through the 10-mm drainage site. The postoperative course after a partial resection of the ileum and drainage with Penrose drains was uneventful. This is the first report of a Richter hernia through the insertion site of a drainage tube in abdominal surgery. The possible occurrence of a Richter hernia in cases with postoperative drainage using large-size round drainage tubes should thus be considered in such patients.

Drainage↗

The relation of fat-free mass to maximum exercise performance in patients with chronic obstructive pulmonary disease.

To assess the factors determining maximum exercise performance in patients with chronic obstructive pulmonary disease (COPD), we examined nutritional status with special reference to body composition and pulmonary function in 50 stable COPD patients. Nutritional status was evaluated by body weight and body composition, including fat mass (FM) and fat-free mass (FFM) assessed by bioelectrical impedance analysis (BIA). Exercise performance was evaluated by maximum oxygen uptake (Vo(2max)) on a cycle ergometer. A total of 50 patients (FEV(1) = 0.98 L) was divided randomly into either a study group (group A, n = 25) or validation group (group B, n = 25). Stepwise regression analysis was performed in group A to determine the best predictors of Vo(2max) from measurements of pulmonary function and nutritional status. Stepwise regression analysis revealed that Vo(2max) was predicted best by the following equation in group A: Vo(2max) (mL/min) = 10.223 x FFM (kg) + 4.188 x MVV (L/min) + 9.952 x DL(co) (mL/min/mmHg) - 127.9 (r = 0.84, p < 0. 001). This equation was then cross-validated in group B: Measured Vo(2max) (mL/min) = 1.554 x Predicted Vo(2max) (mL/min) - 324.0 (r = 0.87, p < 0.001). We conclude that FFM is an important factor in determining maximum exercise performance, along with pulmonary function parameters, in patients with COPD.

Aged↗

Human skin xenograft rejection in CD45 exon-6 knockout mice: the implication of involvement of a direct pathway.

The results of previous studies indicate that only CD4+ T cells generated via the indirect pathway play an essential role in causing discordant skin xenograft rejection. The present study was conducted in an attempt to clarify further the roles of effector T cells generated via direct pathways on discordant xenograft rejection using CD45 exon-6 knockout (CD45-/-; C57BL/6 (B6): H-2b) mice. It has been strongly suggested that CD45 exon-6 knockout mice have profound impairment in T-cell functions via an indirect pathway. When human skin was grafted onto untreated normal C57BL/6 (B6; H-2b) mice, rejection occurred within 12 days; however, in the CD45 exon-6 knockout mice, the grafts lasted for slightly longer as in fully allogeneic C3H (H-2k) skin rejection, with a mean survival time +/- SD of 19.4 +/- 1.5 days and median survival times of 19 days. The difference in survival periods between the human and C3H skin grafts in the CD45 knockout mice was not statistically significant. Both CD4+ and CD8+ T cells seemed activated in the spleens of these CD45 exon-6 knockout mice 10 days after the human skin grafting. These results suggest that effector T cells generated via a direct pathway can cause discordant skin xenograft rejection, and that CD45 exon-6 knockout mice can generate effector T cells via a direct pathway to reject discordant skin xenografts, similarly to fully allogeneic skin allografts.

Animals↗

Possible involvement of 5-HT and 5-HT2 receptors in acceleration of gastrointestinal transit by escin Ib in mice.

We have reported previously that escin Ib accelerated gastrointestinal transit (GIT) in mice, and that its effect may be mediated by the release of endogenous prostaglandins (PGs) and nitric oxide (NO). In this study, the possible involvement of 5-HT and 5-HT receptors in the GIT acceleration of escin Ib was investigated in mice. The acceleration of GIT by escin Ib (25 or 50 mg/kg, p.o.) was attenuated by pretreatment with ritanserin (0.5-5 mg/kg, s.c., a 5-HT(2A/2C/2B) receptor antagonist), but not with MDL 72222 (1 and 5 mg/kg, s.c.) and metoclopramide (10 mg/kg, s.c.) (5-HT3 receptor antagonists) or tropisetron (1 and 10 mg/kg, s.c., a 5-HT(3/4) receptor antagonist). Furthermore, pretreatment with ketanserin (0.05-5 mg/kg, s.c.), haloperidol (1-5 mg/kg, s.c.) and spiperone (0.5-5 mg/kg, s.c.) (5-HT2A receptor antagonists), as well as a bolus of dl-p-chlorophenylalanine methyl ester (PCPA, 1000 mg/kg, p.o., 1, 6 or 24 h before administration of the sample) (an inhibitor of 5-HT synthesizing enzyme tryptophan hydroxylase) and reserpine (5 mg/kg, p.o.) (a 5-HT depletor), but not 6-hydroxydopamine (80 mg/kg, i.p., a dopamine depletor) or repeated PCPA (300 mg/kg x2, p.o., 72 and 48 h before administration of the sample), also attenuated the effects of escin Ib. It is postulated that escin Ib accelerates GIT, at least in part, by stimulating the synthesis of 5-HT to act through 5-HT2, possibly 5-HT2A receptors, which in turn causes the release of NO and PGs.

Animals↗

Inability of cyclophosphamide-induced tolerance to permit engraftment of pluripotent stem cells contained in a moderate number of syngeneic bone marrow cells.

We have previously described cyclophosphamide (CP)-induced tolerance that comprises an intravenous (i.v.) injection of 1 x 10(8) allogeneic spleen cells (SC) followed, 2 days later, by an intraperitoneal (i.p.) administration of 200 mg/kg of CP. By using this method, we were able to readily induce both long-lasting mixed chimerism and skin allograft tolerance in most of H-2 matched combinations, but not in H-2 mismatched combinations. In the present study, we have investigated whether the treatment with SC followed by 200 mg/kg CP can permit engraftment of syngeneic pluripotent hematopoietic stem cells (HSC), and whether CP itself can permit the HSC engraftment. Recipient B6 (H-2b; Ly-5.2) mice received 1 x 10(7), 5 x 10(7) or 1 x 10(8) SC from syngeneic B6.Ly-5.1 (H-2b; Ly-5.1) mice and administered 2 day later 200 mg/kg CP. Using anti-Ly-5.1 and Ly-5.2 mAbs and a flow cytometry, the origins of lymphoid and myeloid cells injecting the recipients were observed over time. Chimerism was at least initially detectable in all groups treated with SC alone (without 200 mg/kg CP), but became undetectable by 32 weeks after the treatment with SC alone. In recipient B6 mice treated with B6.Ly-5.1 SC and 200 mg/kg CP, on the other hand, lymphoid-chimerism was detectable at 32 weeks in a transferred cell dose-dependent manner, but granulocyte-chimerism indicating pluripotent HSC engraftment disappeared earlier than 32 weeks after the treatment. In order to further evaluate the effect of CP itself on HSC engraftment, recipient B6 mice were given various doses of CP (50-400 mg/kg) and were injected with T cell-depleted 1 x 10(7) BMC from B6.Ly-5.1 mice. Multilineage mixed chimerism over 32 weeks was induced in only one of 11 B6 mice treated with 400 mg/kg CP followed by B6.Ly-5.1 BMC, although lymphoid chimerism was induced temporarily in recipient B6 mice treated with 200 mg/kg CP followed by B6.Ly-5.1 BMC and persistently in most of recipient B6 mice treated with 400 mg/kg CP followed by B6.Ly-5.1 BMC.

Animals↗

Clinical evaluation of sonoelasticity measurement in liver using ultrasonic imaging of internal forced low-frequency vibration.

The aim of this study is to evaluate liver elasticity noninvasively. We have already proposed an ultrasonic imaging system that can reconstruct vibration maps inside tissue under forced mechanical vibration. With this system, shear elastic properties of soft tissue can be evaluated as vibration velocities. Theoretically, these velocities increase with the increase of tissue elasticity. Sonoelasticity imaging was performed on 236 patients with chronic hepatitis and liver cirrhosis, and 50 healthy volunteers. The average of the velocities was 598.8 +/- 151.7 cm/s in healthy volunteers, 984.4 +/- 362.5 cm/s in chronic hepatitis and 1189.0 +/- 411.7 cm/s in liver cirrhosis. The average velocity of Child C group was statistically faster than those of Child A and B groups. Fibrotic rate from biopsy specimens statistically had the strongest positive correlation with velocities. With our system, the degree of liver fibrosis and function can be estimated objectively and noninvasively.

Adult↗

Accumulation of 4-hydroxynonenal-modified proteins in hippocampal CA1 pyramidal neurons precedes delayed neuronal damage in the gerbil brain.

It has been proposed that reactive oxygen species and lipid peroxidation have a role in the delayed neuronal death of pyramidal cells in the CA1 region. To explore the in situ localization and serial changes of 4-hydroxy-2-nonenal-modified proteins, which are major products of membrane peroxidation, we used immunohistochemistry of the gerbil hippocampus after transient forebrain ischemia with or without preconditioning ischemia. The normal gerbil hippocampus showed weak immunoreactivity for 4-hydroxy-2-nonenal-modified proteins in the cytoplasm of CA1 pyramidal cells. 4-hydroxy-2-nonenal immunoreactivity showed no marked changes after preconditioning ischemia. In the early period after ischemia and reperfusion, there was a transient increase of nuclear 4-hydroxy-2-nonenal immunoreactivity in CA1 pyramidal neurons. In contrast, cytoplasmic immunoreactivity transiently disappeared during same period and then increased markedly from 8h to seven days. One week after ischemia, 4-hydroxy-2-nonenal immunoreactivity was observed within reactive astrocytes in the CA1 region. Early nuclear accumulation of 4-hydroxy-2-nonenal in CA1 neurons may indicate a possible role in signal transduction between the nucleus and cytoplasm/mitochondria, while delayed accumulation of 4-hydroxy-2-nonenal-modified proteins in the cytoplasm may be related to mitochondrial damage. We conclude that 4-hydroxy-2-nonenal may be a key mediator of the oxidative stress-induced neuronal signaling pathway and may have an important role in modifying delayed neuronal death.

Aldehydes↗

Alcohol absorption inhibitors from bay leaf (Laurus nobilis): structure-requirements of sesquiterpenes for the activity.

Through a bioassay-guided separation using inhibitory activity on blood ethanol elevation in oral ethanol-loaded rat, various sesquiterpenes having an alpha-methylene-gamma-butyrolactone moiety, costunolide (1), dehydrocostus lactone (2), zaluzanin D (3), reynosin (4), santamarine (5), 3alpha-acetoxyeudesma-1,4(15),11(13)-trien-12,6alpha-+ ++olide (6) and 3-oxoeudesma-1,4,11(13)-trien-12,6alpha-olide (7), were isolated as the active principle from the leaves of Laurus nobilis (bay leaf, laurel). In order to characterize the structure requirement for the activity, several reduction products (2a-2d) and amino acid adducts (2e, 2f) of the alpha-methylene-gamma-butyrolactone moiety were synthesized from 2 and the inhibitory activities of these sesquiterpenes, together with alpha-methylene-gamma-butyrolactone (12) and its related compounds (13-16), were examined. These results indicated that the gamma-butyrolactone or gamma-butyrolactol moiety having alpha-methylene or alpha-methyl group was essential for the inhibitory activity on ethanol absorption. Since 1, 2 and 12 showed no significant effect on glucose absorption, these sesquiterpenes appeared to selectively inhibit ethanol absorption. In addition, the acute toxicities of 1 and 2 in a single oral administration were found to be lower than that of 12.

4-Butyrolactone↗

Two basic residues, Lys-107 and Lys-118, of RuvC resolvase are involved in critical contacts with the Holliday junction for its resolution.

BACKGROUND: Crystallographic and mutational studies of Escherichia coli RuvC Holliday junction resolvase have revealed that a catalytic site of each subunit is composed of four acidic residues at the bottom of the putative DNA-binding cleft, whose surface contains eight basic residues. RESULTS: To elucidate the functional roles of the basic residues on the cleft surface, we constructed a series of mutant ruvC genes and characterized their properties in vivo and in vitro. Among them, two RuvC mutants with a single alteration, K107A and K118A, were defective in UV-repair and showed a dominant negative effect. The purified K107A and K118A proteins showed reduced binding activity to the junction DNA in the presence of Mg2+ under high salt conditions. Mn2+ increased both the junction binding and cleaving activities of the mutant proteins. In the absence of a divalent cation, the wild-type, K107A and K118A proteins did not bind to junction DNA under high salt conditions, but the D7N mutant, with an alteration of the catalytic centre, was able to bind to the junction efficiently. CONCLUSION: The results presented here, in conjunction with previous crystallographic studies, suggest that the catalytic complex which is formed through interactions of acidic residues, Mg2+ and a cleavable phosphodiester bond, is stabilized by Lys-107 and Lys-118 via electrostatic interactions with the DNA backbone, a process which is critically important for the cleavage reaction to take place. One or two basic residues near the catalytic centre have also been found in other RNase H superfamily proteins, indicating that this is the conserved reaction mechanism in this superfamily.

Amino Acid Sequence↗

Mutational analysis of the functional motifs of RuvB, an AAA+ class helicase and motor protein for holliday junction branch migration.

Escherichia coli RuvB protein, together with RuvA, promotes branch migration of Holliday junctions during homologous recombination and recombination repair. The RuvB molecular motor is an intrinsic ATP-dependent DNA helicase with a hexameric ring structure and its architecture has been suggested to be related to those of the members of the AAA+ protein class. In this study, we isolated a large number of plasmids carrying ruvB mutant genes and identified amino acid residues important for the RuvB functions by examining the in vivo DNA repair activities of the mutant proteins. Based on these mutational studies and amino acid conservation among various RuvBs, we identified 10 RuvB motifs that agreed well with the features of the AAA+ protein class and that distinguished the primary structure of RuvB from that of typical DNA/RNA helicases with seven conserved helicase motifs.

Amino Acid Sequence↗

Accumulation of copper in the liver and hepatic injury in chronic hepatitis C.

BACKGROUND AND AIMS: Relationships between chronic liver disease and trace metals have not been clearly understood. To examine connections between severity of hepatic fibrosis in chronic hepatitis C and copper, iron and zinc we measured the contents of these metals in liver tissue and serum in the patients. METHODS: Forty-one patients (26-62 years), 13 with fibrosis representing grade F1, 16 with F2, seven with F3, and five with F4, entered this study. Metals were quantified in needle liver-biopsy specimens by particle-induced X-ray emission. In serum, metals were measured by flameless atomic absorption spectrometry. RESULTS: Hepatic copper content increased with progression of hepatic fibrosis (P < 0.05). The copper content correlated positively with bilirubin (r = 0.466, P = 0.0023), and with type IV collagen (r = 0.402, P = 0.0086) and correlated negatively with albumin (r = -0.404, P = 0.080). However, hepatic iron and zinc contents did not show a significant differences between grades of fibrosis. CONCLUSIONS: Copper accumulation in fibrotic livers caused by chronic hepatitis C may contribute to hepatic injury. The real mechanism is not known at present, but excess copper may damage the liver by oxidative stress.

Adult↗

Analysis of the arterial blood pressure waveform using Fast Fourier Transform technique during left ventricular nonpulsatile assistance: in vitro study.

The arterial blood pressure waveform is variable during left ventricular assistance. The aim of this study is to examine the correlation between the left ventricular assist device (LVAD) condition and the arterial blood pressure waveform in a fixed cardiac output condition using a mock circuit. This mock circulation loop was composed of an aortic compliance chamber, a left atrial compliance chamber, a pneumatic pulsatile pump as a native heart, and a rotary blood pump representing the LVAD with left atrial drainage. The Fast Fourier Transform technique was utilized to analyze the arterial blood pressure waveform and calculate the pulsatility index (PI) and the pulse power index (PPI). The PI and PPI decreased with the increase of the LVAD rotational speed, exponentially. There was a significant negative correlation between the PI, PPI, and the LVAD rotational speed, flow rate, and assist ratio. The best correlation was observed between the PPI and the assist ratio (r = 0.986). From this viewpoint, an ideal LVAD condition may be estimated from the pulsatility change of the arterial blood pressure waveform.

Blood Pressure↗

Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study.

The control system for an implantable rotary blood pump is not clearly defined. A detection system is considered to be necessary for pump flow monitoring and abnormal conditions such as back flow or a sucking phenomenon where the septum or left ventricle wall is sucked into the cannula, etc. The ultrasound flowmeter is durable and reliable but the control system should not be totally dependent on the flowmeter. If the flowmeter breaks, the rotary blood pumps have no control mechanism. Therefore, the authors suggest controlling the pumps by an intrinsic parameter. One left ventricular assist device (LVAD) calf model was studied where the flow rate and waveform of the pump flow proved to identify the sucking phenomenon. Thus, the pump flow rate was calculated from the required power, motor speed, and heart rate. The value of the coefficient of determination (R2) between the measured and estimated pump flow rate was 0.796. To estimate this abnormal phenomenon, 2 methods were evaluated. One method was the total pressure head in which the pump flow rate and motor speed were estimated. During normal conditions the total pressure head is 79.5 +/- 7.0 mm Hg whereas in the abnormal condition, it is 180.0 +/- 2.8 mm Hg. There was a statistical difference (p < 0.01). Another method is using a current waveform. There is an association between the current and pump flow waves. The current was differentiated and squared to calculate the power of the differentiated current. The normal range of this value was 0.025 +/- 0.029; the abnormal condition was 11.25 +/- 15.13. There was a statistical difference (p < 0.01). The predicted flow estimation method and a sucking detection method were available from intrinsic parameters of the pump and need no sensors. These 2 methods are simple, yet effective and reliable control methods for a rotary blood pump.

Animals↗

Right ventricular assist system feedback flow control parameter for a rotary blood pump.

At least 25-30% of patients with a permanent implantable left ventricular assist device (LVAD) experience right ventricular failure; therefore, an implantable biventricular assist system (BiVAS) with small centrifugal pumps is being developed. Many institutions are focusing and developing a control system for a left ventricular assist system (LVAS) with rotary blood pumps. These authors feel that the right ventricular assist system (RVAS) with rotary blood pumps should be developed simultaneously. A literature search indicated no recent reports on the effect of hemodynamics and exercise with this type of nonpulsatile implantable RVAS. In this study, a calf with an implantable right ventricular assist system (RVAS) was subjected to 30 min of exercise on a treadmill at 1.5 mph, resulting in excellent hemodynamics. The input voltage remained unchanged. Hemodynamic recordings were taken every 5 min throughout the testing period, and blood gas analysis was done every 10 min. Oxygen uptake (VO2), oxygen delivery (DO2), and oxygen extraction (O2ER) were calculated and analyzed. Two different pump flows were investigated: Group 1 low assist (<3.5 L/min) and Group 2 high assist (>3.5 L/min). In both groups, the RVAS flow rates were unchanged while the pulmonary artery (PA) flow increased during exercise; also, the heart rate and right atrial pressure (RAP) increased during exercise. There were no significant differences in the 2 groups. The PA flow correlates to the heart rate during exercise. In all of the tests, the VO2 and DO2 increased during exercise. Regarding VO2, no changes were observed during the different flow conditions; however, the DO2 of Group 2 was higher than that of Group 1. Because the implantable RVAS did not have pump flow changes during the test conditions, it was necessary to incorporate a flow control system for the implantable RVAS. During exercise with an implantable RVAS rotary blood pump, incorporating the heart rate and VO2 as feedback parameters is feasible for controlling the flow rate.

Animals↗

Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump.

The Gyro centrifugal pump, PI (permanently implantable) series, is being developed as a totally implantable artificial heart. Our final goal is to establish a "functional TAH," a totally implantable biventricular assist system (BiVAS) with centrifugal pumps. A plastic prototype pump, Gyro PI 601, was evaluated through in vitro and in vivo studies as a single ventricular assist device (VAD). Based upon these results, the pump head material was converted to a titanium alloy, and the actuator was modified. These titanium Gyro pumps, PI 700 series, also were subjected to in vitro and in vivo studies. The Gyro PI 601 and PI 700 series have the same inner dimensions and characteristics, such as the eccentric inlet port, double pivot bearing system, secondary vane, and magnet coupling system; however, the material of the PI 700 is different from the PI 601. The Gyro PI series is driven by the Vienna DC brushless motor actuator. The inlet cannula of the right ventricular assist system (RVAS) specially made for this system consists of 2 parts: a hat-shaped silicone tip biolized with gelatin and an angled wire reinforced tube made of polyvinylchloride. The pump-actuator package was implanted into 8 calves in the preperitoneal space, bypassing from the left ventricle apex to the descending aorta for the left ventricular assist system (LVAS) and bypassing the right ventricle to the main pulmonary artery for the RVAS. According to the PI 601 feasibility protocol, 2 LVAS cases were terminated after 2 weeks, and 1 LVAS case and 1 RVAS were terminated after 1 month. The PI 700 series was implanted into 4 cases: 3 LVAS cases survived for a long term, 2 of them over 200 days (72-283 days), and 1 RVAS case survived for 1 month and was terminated according to the protocol for a short-term antithrombogenic screening and system feasibility study. Regarding power consumption, the plastic pump cases demonstrated from 6.2 to 12.1 W as LVAS and 7.3 W as RVAS, the titanium pump cases showed from 10.4 to 14.2 W as LVAS and 15.8 W as RVAS. All cases exhibited low hemolysis. The renal function and the liver function were maintained normally in all cases throughout these experimental periods. In the 2 RVAS cases, pulmonary function was normally maintained. No calves demonstrated thromboembolic signs or symptoms throughout the experiments except Case 1 with the plastic pump. However, in the plastic pump cases, bilateral renal infarction was suspected in 2 cases during necropsy whereas no abnormal findings were revealed in the titanium pump cases. There were also no blood clots inside the PI 700 series. As for the 601, the explanted pumps demonstrated slight thrombus formations at the top and bottom pivots except in 1 case. The Gyro PI series, especially the PI 700 series, demonstrated superior performance, biocompatibility, antithrombogenicity and low hemolysis. Also, the durability of the actuator was demonstrated. Based on these results, this titanium centrifugal pump is suitable as an implantable LVAS and RVAS. It is likely that the Gyro PI series is a feasible component of the BiVAS functional TAH.

Animals↗

Gyro pump wear and deformation analysis in vivo study: creep deformation.

The Gyro pump has a double pivot bearing system to support its impeller. In this study, the integrity of the bearing system was examined after ex vivo studies. The pumps were implanted into calves and evaluated for different periods as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to a test of 30 days, 1 for 15 days, 4 for 14 days, 1 for 10 days, 1 for 7 days, 2 for 4 days, and 4 for 2 days. One additional pump was subjected to percutaneous cardiopulmonary support (PCPS) condition for 6 days (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an achieved clotting time (ACT) of 200-250 s during the LVAD study and 250-300 s during the PCPS study. After the experiment, the pumps were disassembled, and the wear and deformation of male and female bearings were analyzed. There were no dimensional changes on male bearings but there were on female bearings. Wear and deformation of the female bearings were calculated as follows: wear and deformation = (depth of female before pumping) - (depth after pumping). Thirteen assembled Gyro pumps were disassembled to measure the depth of the female bearings before pumping. There was no statistical relationship between the wear and deformation and the motor speed x driving period. From these results, the deformation was not due to wear but to the creep or elastic deformation. This study suggested that the double pivot bearing system of the Gyro pump is highly durable.

Animals↗

Antithrombogenicity evaluation of a centrifugal blood pump.

The Gyro C1E3 pump was developed not only for cardiopulmonary bypass but also as a short-term assist device. The main purpose of this study was to examine the correlation between the thrombus formation factor and the Gyro C1E3 pumps. Seven pumps were implanted into 3 calves and evaluated for different periods of duration as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to percutaneous cardiopulmonary support condition (PCPS) (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an activated clotting time (ACT) of 200-250 during the LVAD study and 250-300 during the PCPS study. After the experiment, the pumps were disassembled and examined. In cases where there were any blood-derived deposits inside the pumps, the dry weight of these thrombi that adhered to the bearing area of the pump was measured. A multiple correlation was attempted to speculate possible thrombus formation. The estimated dry weight of thrombi was calculated from pump flow rate, pumping day, motor speed, and activated clotting time. This equation was estimated dry weight of thrombi = 1.140 x pump flow rate -0.001 motor speed + 1.652 pumping time -0.041 x ACT + 2.198 R2 = 0.944. This study suggested that there was a possibility to calculate the amount of adhered thrombus formation from pump flow rate, motor speed, pumping day, and ACT.

Animals↗

Particles released from the Gyro C1E3 during simulated extracorporeal circulation.

Evaluation of released particles from the blood pump during extracorporeal circulation is an important aspect because the particles may cause microembolism. The Gyro C1E3 is a centrifugal blood pump that has an impeller suspended by double pivot bearings inside the housing; therefore, it is important to evaluate the released particles. The C1E3 was driven for 14 days to simulate clinical left ventricular assist device (LVAD) and percutaneous cardiopulmonary support (PCPS). Also, a roller pump was driven for 2 days as a comparison. Released particles were weighed and examined by SEM. After 14 days of pumping, the particles from the C1E3 were 238.6 microg in an LVAD condition. The particles with the roller pump were 270.2 microg after only 2 days. Average particle sizes with the roller pump and C1E3 were 3.7 and 0.6 microm, respectively. These results suggest that the Gyro C1E3 substantially reduces the risk of microembolism from released particles.

Biocompatible Materials↗