Rapid and continuous monitoring of cerebral perfusion by magnetic resonance line scan assessment with arterial spin tagging.

A new approach is presented for rapid and continuous monitoring of cerebral perfusion which is based upon line-scan MR column imaging with arterial spin tagging (AST) of endogenous water. Spin tagging of arterial water protons is accomplished using adiabatic fast passage inversion, followed by acquisition of the perfusion sensitive MR signal from a column placed at the desired level through the brain using line scan localization techniques. A perfusion sensitive line scan is followed by a non-perfusion sensitive line scan, and perfusion is calculated pixel-by-pixel from the intensity difference of the two lines. Continuous perfusion measurements are reported with temporal resolution of 10 s in pixels of volume 0.027 cm3 or less. Examples of the methodology are given during hypercapnic challenge induced with carbon dioxide, and during an ischemic event induced by reversible middle cerebral artery occlusion. The method is also used to characterize the signal response as a function of arterial inversion time and post inversion acquisition delay. These methods permit rapid and continuous monitoring of cerebral perfusion with high spatial resolution, and can be interleaved with MR measurements of diffusion and T1 to follow the progression of cerebral events during physiological or pharmacological intervention.

Animals↗

MR perfusion imaging in human brain using the UNFAIR technique. Un-inverted flow-sensitive alternating inversion recovery.

Pulsed arterial spin labeling magnetic resonance techniques have been developed recently to estimate cerebral blood flow (CBF). Flow-sensitive alternating inversion recovery (FAIR) is one such technique that has been implemented successfully in humans. Un-inverted FAIR (UNFAIR) is an alternative technique in which the flow-sensitive image is acquired following inversion of all spins outside the slice of interest, and the control image is acquired without any spin labeling. This approach is potentially more efficient than FAIR since the UNFAIR control image is entirely flow independent and need only be acquired once. Here, we describe implementation of the sequence on a clinical 1.5 T magnetic resonance system. Both FAIR and UNFAIR perfusion-weighted images were obtained from six normal volunteers. Wash-in/wash-out curves measured in cortical gray and white matter were practically identical for the two techniques, as predicted by our model.

Adult↗

High resolution renal diffusion imaging using a modified steady-state free precession sequence.

A modified steady-state free precession (SSFP) diffusion sequence is proposed for high resolution renal imaging. A pair of bipolar diffusion gradients was used to minimize the errors in measured apparent diffusion coefficient (ADC) caused by variations in T1, T2, and RF flip angle that have been observed with previously employed SSFP diffusion sequences. Motion sensitivity was reduced by the use of compensated gradients, frame-by-frame averaging, and a repetition time of 22 ms, which for a single-acquisition 128 x 128 image requires only 3 s. High resolution was achieved by signal averaging. The modified sequence was applied to in vivo diffusion measurements. In six normal rat kidneys the ADCs (mean +/- SD; x 10(-3) mm2/s) of the cortex, outer medulla, and inner medulla were 2.28 +/- 0.05, 2.38 +/- 0.10, and 2.95 +/- 0.05, respectively. The technique requires relatively large gradients to achieve adequate diffusion weighting.

1-Propanol↗