Isoflavones of Belamcanda chinensis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Yamaki.
Explore the source record for details and available documents.
Some recently developed industrial ceramics have excellent machinability properties. The objective of this study was to evaluate the dental cutting behaviour of two machinable glass-ceramics, mica-containing Macor-M and apatite- and diopside-containing Bioram-M, and to compare them with the cutting behaviour of a composite resin typodont tooth enamel and bovine enamel. Weight-load cutting tests were conducted, using a diamond point driven by an air-turbine handpiece, While the transverse load applied on the point was varied, the handpiece speed during cutting and the volume of removal upon cutting were measured. In general, an increase in the applied load caused a decrease in cutting speed and an increase in cutting volume. However, the intensity of this trend was found to differ between four workpieces. Cutting Macor-M resulted in the second-most reduced cutting speed and the maximum cutting volume. Cutting Bioram-M gave the least reduced cutting speed and the minimum cutting volume. It was suggested that two machinable glass-ceramics could be employed as typodont teeth. This study may also contribute to the development of new restorative dental ceramic materials, prepared by machining.
One important mechanical property of dental ceramics is fracture toughness, KIC, which represents the serviceability in the oral cavity, such as the resistance to marginal fracture. KIC values of several dental ceramics, natural tooth enamel and industrial ceramics were examined by use of the indentation microfracture (IM) method. This technique was based on the series of radial cracks emanating from the corners of the Vickers indentation. It was observed that appropriate load levels should be selected on each specimen to induce radial/median cracks. For feldspatic dental porcelains, larger loads of 10, 20 and 30 kg were needed to determine their KIC values in the range 1.5-2.1 MN.m-3/2. For natural tooth enamel and a new apatite-based castable glass-ceramic, a smaller force of 1 kg was sufficient to decide the respective KIC values of about 0.9 and 1.8 MN.m-3/2. The KIC values of most dental ceramics examined were slightly higher than that of soda lime glass, but less than one-third that of zirconia. It was confirmed that the IM method is simple and cost-effective for evaluation of KIC of dental ceramics.
To examine whether or not the location of local abnormalities on body surface isochrone maps reflects the site of myocardial ischemia, 48 coronary artery disease patients without myocardial infarction were studied. Eighty-seven unipolar electrocardiograms distributed over the anterior chest and the back were recorded simultaneously before and after the submaximal treadmill exercise. For each lead, the duration from the QRS onset to the time of the most rapid decrease in QRS voltage was measured (index of ventricular activation [IVA]). Based o the data provided by these 87 leads, IVA isochrone maps (IVA map) in preexercise and in postexercise, as well as IVA maps showing the difference between preexercise and postexercise, were constructed. The IVA was defined as abnormal when it exceeded (mean + 2 SD) the normal range. We called the area with the abnormal IVA, the "+2SD area." In patients having a stenosis in the left anterior descending artery, the +2SD area in each map was located mainly on the left anterior chest, whereas in patients having a stenosis in the right coronary artery, the +2SD area in each map was located mainly on the right lower thoracic surface. Moreover, the +2SD area of patients with both left anterior descending and right coronary artery disease appeared on both the left anterior chest and the right lower thoracic surface. In patients with left circumflex artery disease, however, the location of the +2SD area did not suggest a stenotic site because of its small population. On the other hand, it was difficult to determine the ischemic site from the body surface distribution of ST segment depression.(ABSTRACT TRUNCATED AT 250 WORDS)
With the use of epicardial mapping, we investigated the electrical alternans of the ST segment during acute myocardial ischemia and studied the difference in ST alternans between dogs with resultant ventricular fibrillation and those without it. During the 7-minute occlusion of the left anterior descending coronary artery below its first diagonal branch, 60 epicardial unipolar electrograms were recorded simultaneously at 1-minute intervals by a computerized mapping system. ST alternans was found in the eight dogs we observed. The amplitude of ST alternans (difference in the ST segment elevation of two consecutive electrograms) was greater in dogs with ventricular fibrillation (n = 4) than in those without it (n = 4) (3.92 +/- 1.24 versus 0.58 +/- 0.49 mV, p less than 0.05). Three of the four dogs with ventricular fibrillation demonstrated discordant ST alternans (i.e., adjacent leads were out of phase). Results from the present study indicate that an increased amplitude and discordance of ST alternans during acute myocardial ischemia are related to ventricular fibrillation and act as indicators of time and spatial unevenness of ventricular repolarization.
In order to assess diastolic overload by electrocardiogram (ECG), we performed body surface ECG mapping (MAP), and then compared the results with echocardiographic, roentgenographic and cardiac catheterization findings. Eighty-seven unipolar electrocardiograms were simultaneously recorded for the following groups: 1) 40 normal subjects, 2) 46 patients with diastolic overload [32 patients with aortic regurgitation (AR) and 14 patients with mitral regurgitation (MR)]. QRS isopotential maps were constructed at 10, 20, 30, 40, 50 and 60 msec from the QRS onset. On the potential departure map, the area where the QRS voltage was greater than the normal limits (mean + 2SD of normal control) was designated as "+2SD area". In patients with diastolic overload, +2SD area was found on the left anterior chest and back at 40, 50 and 60 msec from QRS onset. Subjects were classified into the following 3 groups according to the location of their +2SD area: 1) group A (n = 23) in which the +2SD area was found on the left anterior chest and back, 2) group B (n = 17) in which the +2SD area was found only on the back, and 3) group N (n = 6) in which no +2SD area was found. Group A had a markedly greater left ventricular end-diastolic internal dimension than the other groups (A 63.6 +/- 6.8 mm, B 53.9 +/- 5.5 mm, N 50.7 +/- 6.0 mm, A vs. B, N p less than 0.01), and a greater cardiothoracic ratio than the other groups (A 58.5 +/- 5.6%, B 52.5 +/- 7.0%, N 52.3 +/- 4.7%, A vs. B, N p less than 0.01). There was no significant difference in wall thickness among the 3 groups. The regurgitation severity assessed by cardiac catheterization was greater in group A than in the other groups. Among AR patients, the +2SD area was located on the upper back and the upper anterior chest, whereas among MR patients, it tended to be located on the lower portions. The potential departure map is a useful noninvasive analytic method for determining the extent and grade of diastolic overload. Furthermore, the location of the +2SD area may be used to discriminate between AR and MR.
To evaluate the effect of the diamond grit size of commercial dental diamond points on the dental cutting, we conducted weight-load cutting tests on bovine enamel and glass-ceramic typodont teeth using 3 different diamond grit sizes and air-bearing and ball-bearing air-turbine driven handpieces. With the transverse load applied on the diamond point varied between 20 and 80 g, we measured rotational cutting speed and cutting volume. Generally, increases in applied load caused decreases in rotational cutting speed and increases in cutting volume. The intensity of this trend, however, differed between grit sizes. Regular grit diamond points most strongly showed this tendency, while super-fine grit diamond points were least affected. Fine grit diamond points behaved in a manner similar to regular grit points.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
To improve the diagnostic usefulness of electrocardiography (ECG) in determining the severity of left ventricular hypertrophy (LVH) with body surface mapping, 87 unipolar ECGs were recorded from 57 patients with left ventricular (LV) concentric hypertrophy and 30 with LV dilatation. Body surface ECG features due to LVH were evaluated by increase of QRS voltage and delayed local activation. We measured for each lead R voltage, net area of QRS (AQRS), ventricular activation time (VAT), and departure index (DI) of AQRS and VAT (DI = mean/SD). From these measurements, seven parameters were calculated for each patient: Rmax, the maximal R wave voltage; AQRSmax, the maximal AQRS; AQRS-Dmax, the maximal AQRS DI; AQRS-Darea, the area size where DIs of AQRS are more than 2; VATmax, the maximal VAT; VAT-Dmax, the maximal VAT DI; and VAT-Darea, the area size where DIs of VAT are more than 2. Among these parameters, the most effective for diagnosis of LVH were selected by stepwise multiple regression analysis. In the concentric hypertrophy group, the combination of VAT-Darea and Rmax was determined to be the best for estimating wall thickness. The regression equation determined from them correlated well to wall thickness (r = 0.73). In the LV dilatation hypertrophy group, only AQRSmax was selected for estimating LV dilatation. A good correlation between AQRSmax and LV internal dimension was observed (r = 0.73). With the body surface distribution of VAT prolongation, septal hypertrophy was separated from the other LVH. These were superior to the conventional method of 12-lead ECGs. ECG diagnosis of LVH severity improved by incorporating a mapping study. Also, prolongation of VAT and increase in QRS voltage were shown to be important when determining the severity of LVH.
The correlation between the treadmill exercise test results and the hemodynamic data of 152 patients with previous myocardial infarction were investigated. The patients were classified into 4 groups as follows: H1 left ventricular end-diastolic pressure (LVEDP) less than or equal to 12 mmHg and cardiac index (CI) greater than or equal to 3.0 L/min/m2; H2 LVEDP greater than 12 mmHg and CI greater than or equal to 3.0 L/min/m2; H3 LVEDP less than or equal to 12 mmHg and CI less than 3.0 L/min/m2; and H4 LVEDP greater than 12 mmHg and CI less than 3.0 L/min/m2. The duration of the exercise was significantly shortened for group H4 than group H1 (p less than 0.01). The maximal ST segment elevation (mSTe) was significantly increased for group H3 and group H4, versus group H1 (p less than 0.05). The number of ST segment elevations and mSTe/maximal heart rate were significantly increased for group H3 (p less than 0.05) and group H4 (p less than 0.01) versus group H1. The incidence of exercise-induced premature ventricular contractions (PVCs) was significantly increased in group H3 and group H4, versus group H1 (p less than 0.05). There were no significant differences in the maximal heart rate, double product, and ST segment depression among the 4 groups. Our data indicate that the groups with impaired left ventricular functions tend to decrease the duration of the exercise and to increase ST segment elevation and PVC frequencies during exercise.
Eighty-seven unipolar electrocardiograms were simultaneously recorded before and after symptom-limited treadmill exercise in 75 patients with coronary artery narrowing (greater than equal to 70%) and without previous myocardial infarction. Body surface distributions of ST segment depression were divided into 3 types; upper, lower, and diffuse types. Body surface distributions of U-wave inversion were divided into 2 types; upper, and lower types. These distribution patterns were compared with the location of ischemia determined by T1-201 exercise myocardial perfusion imaging. For ST-segment depression, a considerable number of patients had diffuse-type ST depression, whether the site of ischemia was anterior (22/32, 69%), inferior (18/27, 67%) or both (5/5, 100%). However, upper-type ST depression was associated with anterior ischemia, and lower-type ST depression, with inferior ischemia. The sensitivity and specificity of the spatial distribution of ST depression in identifying the myocardial ischemic site were 27% and 95% for anterior ischemia. The sensitivity and specificity of the spatial distribution of St depression in identifying the myocardial ischemic site were 27% and 95% for anterior ischemia respectively, and 28% and 88% for inferior ischemia, respectively. The incidence of U-wave inversion was moderate (29/75, 39%), but the distribution pattern was specific for the site of ischemia; upper-type U inversion associated with anterior ischemia, and lower type with inferior ischemia. The sensitivity and specificity were 59% and 100% for anterior ischemia respectively, and 22% and 100% for inferior ischemia respectively. By a combination of ST-depression and U-inversion, the sensitivity and specificity were 78% and 95% for anterior ischemia, and 44% and 88% for inferior ischemia. Body surface electrocardiographic mapping provided important information in the non-invasive diagnosis of the site of myocardial ischemia.
Machinable ceramics that can be cut and even lathed have recently been developed in industry. As a first step in evaluating the feasibility of such ceramics in dentistry, eight machinable ceramics were examined for color using the Vita shade guide and a chroma-meter reflectance instrument. We discovered that the studied machinable ceramics varied significantly from the Vita shade guide by the color difference vector, delta E. These machinable ceramics appeared very white and strongly opaque due to their high brightness (L*) values. For intra-oral applications, we expect that L* values of machinable ceramics will be reduced by modification of their microstructures, including their matrix and dispersed phases, while their excellent machinability due to the cleavage of dispersed crystals should be retained.
We examined the effects of air pressure on the free-running speed of air-bearing and torque-type ball-bearing air-turbine handpieces. The air pressure for the former should be kept at a certain high level to maintain the stable super-thin air-bearing film and to provide the quasi-constant speed of around 420,000 to 480,000 rpm. On the other hand, the air pressure for the latter could be adjusted to provide some varieties of speeds, ranging from about 150,000 to 320,000 rpm. Subsequently, to compare torque properties and cutting effectiveness between these two handpieces, weight-load cutting tests were conducted, using a glass-ceramic workpiece and a commercial diamond point. It was confirmed that the air-bearing handpiece had the lower torque power but exhibited better cutting effectiveness, compared with its counterpart.