Search PubMed⌕ Search

Biomedical subjects

M Yabashi

Publications and source records attributed to M Yabashi.

9 recordsLinked to original sources

Evidence for suppressed screening on the surface of high temperature La(2-x)SrxCuO4 and Nd2(2-x)CexCuO4 superconductors.

Hard x-ray photoemission spectroscopy (PES) of Cu core electronic states, with a probing depth of approximately 60 A, is used to show that the Zhang-Rice singlet feature is present in La2CuO4 but is absent in Nd2CuO4. Hole and electron doping in La(2-x)SrxCuO4 (LSCO) and Nd(2-x)CexCuO4 (NCCO) result in new well-screened features which are missing in soft x-ray PES. Impurity Anderson model calculations establish screening from doped states as its origin, which is strongly suppressed within 15 A of the surface. Complemented with x-ray absorption spectroscopy, the small chemical-potential shift in core levels (approximately 0.2 eV) are shown to be consistent with modifications of valence and conduction band states spanning the band gap (approximately 1 eV) upon hole and electron doping in LSCO and NCCO.

Journal Article↗

X-ray resonance in crystal cavities: realization of Fabry-Perot resonator for hard x rays.

X-ray back diffraction from monolithic two silicon crystal plates of 25-150 microm thickness and a 40-150 microm gap using synchrotron radiation of energy resolution DeltaE = 0.36 meV at 14.4388 keV clearly show resonance fringes inside the energy gap and the total-reflection range for the (12 4 0) reflection. This cavity resonance results from the coherent interaction between the x-ray wave fields generated by the two plates with a gap smaller than the x-ray coherence length. This finding opens up new opportunities for high-resolution and phase-contrast x-ray studies, and may lead to new developments in x-ray optics.

Journal Article↗

Nature of the well screened state in hard X-ray Mn 2p core-level photoemission measurements of La1-xSrxMnO3 films.

Using hard x-ray (HX; hnu=5.95 keV) synchrotron photoemission spectroscopy (PES), we study the intrinsic electronic structure of La(1-x)Sr(x)MnO(3) (LSMO) thin films. Comparison of Mn 2p core-levels with soft x-ray (SX; hnu approximately 1000 eV) PES shows a clear additional well-screened feature only in HX PES. Takeoff-angle dependent data indicate its bulk (> or =20 A) character. The doping and temperature dependence track the ferromagnetism and metallicity of the LSMO series. Cluster model calculations including charge transfer from doping-induced states show good agreement, confirming this picture of bulk properties reflected in Mn 2p core-levels using HX PES.

Journal Article↗

Deterministic retrieval of surface waviness by means of topography with coherent X-rays.

A surface profile retrieval technique from multiple X-ray total reflection images taken at various distances with full coherent illumination is demonstrated. An experiment was performed using the 1 km-long BL29XU beamline at the SPring-8 facility, Japan. Obtained results are compared with results from the optical metrology technique (Fizeau's interferometer). Good agreement between X-ray and optical methods proves the validity of the current approach. Meanwhile, the sensitivity of the X-ray technique is several times higher than that of the standard one. This technique is well suited to the needs of characterizing grazing optics for new-generation X-ray sources.

Journal Article↗

Measurement of x-ray pulse widths by intensity interferometry.

The pulse width of hard undulator radiation (32 ps width, energy 14 keV) was determined by intensity interferometry. The method, in combination with various x-ray monochromators, enables measurements to be taken over a wide range of time frames, from ns to fs. The applicable target includes measurements of ultrafast x-ray pulse widths from fourth generation synchrotron light sources.

Calibration↗

X-ray interferometry with multicrystal components using intensity correlation.

A theoretical relation between intensity correlation and interference was experimentally verified for the case of a large-separation skew-symmetric bicrystal interferometer. The intensity correlation was enhanced in the angular range where the interference fringes were clearly observed. An application investigating the interference condition of the interferometer is presented using the intensity-correlation technique.

Journal Article↗

Standard transport channels of X-ray beamlines at SPring-8.

SPring-8 is constructing most of its beamlines using a combination of standardized components. The structures of the beamlines are also standardized according to the light-source characteristics. Specifications of components as well as the unified method of assembly and alignment are described.

Journal Article↗

Two-photon correlations in X-rays from a synchrotron radiation source.

The intensity correlation experiment using visible light performed by Hanbury Brown & Twiss [Nature (London) (1956), 177, 27-29] is extended to X-ray wavelengths. Correlations of 14.4 keV X-ray photons from a synchrotron radiation source are observed by the coincidence counting technique. The high brilliance of synchrotron radiation available in the Tristan main ring enables the observation of two-photon correlations with a reasonable measurement time.

Journal Article↗