Search PubMed⌕ Search

Biomedical subjects

M Weyand

Publications and source records attributed to M Weyand.

At least 73 records · Page 4Linked to original sources

Beating heart implantation of a wearable NOVACOR left-ventricular assist device.

Implantable left-ventricular assist devices (LVAD) are successfully used as a bridge to transplant if the patient's condition is worsening and no donor organ is available. They allow recovery of compromised organ function. However, postoperative bleeding, thrombemboelism, and right-heart failure may jeopardize the important improvement of organ function and may even lead to death. We introduce our strategy for implantation of the Novacor LVAD system, which aims at minimal bleeding and maintained right-heart function. The Novacor LVAD was implanted with the heart beating during extracorporeal circulation in 8 patients, 3 of whom had previous cardiac surgery. Postoperatively, no patient developed right heart failure or had to undergo redo thoracotomy.

Adult↗

Multiple cardiac procedures after heart transplantation: a case report.

We report on a 56-year-old patient who underwent coronary artery bypass grafting, tricuspid valve replacement, and pacemaker implantation within 49 months after heart transplantation. This case readily demonstrates that multiple cardiac procedures can be safely performed after heart transplantation and may thus serve as an alternative to retransplantation.

Cardiac Surgical Procedures↗

Coronary compliance in patients following orthotopic heart transplantation. An intravascular ultrasound study.

BACKGROUND: The aim of this study was to investigate coronary compliance in patients early and 71.8 weeks after orthotopic heart transplantation. METHODS: Thirty patients (mean age 51.4 years, women n = 6) underwent coronary angiography early after orthotopic heart transplantation (mean interval 11.6 +/- 5.5 weeks), by which time 12 recipients had already been treated for episodes of rejection. A total of 153 different coronary segments were investigated using a mechanical 30 MHz intravascular ultrasound system. In all segments, the intimal index and the circumferential extension of the vessel wall, which had a three-layered appearance, were assessed. Systolic-diastolic changes in area, and pressure with respect to vessel wall area, were used to study normalized compliance. All measurements were repeated in a subgroup of 13 patients 71.8 +/- 10.7 weeks after transplantation. RESULTS: At the first investigation, the mean intimal index of all estimated cross-sectional areas was 0.07 +/- 0.10. The mean circumferential extension of the 'three-layered' coronary vessel wall was 74 degrees +/- 101 degrees. No correlation could be found between normalized compliance and the intimal index (r = -0.322, P < 0.001) or between normalized compliance and the circumferential extension of the three-layered vessel wall (r = -0.362, P < 0.001). Donor age did not correlate with normalized compliance either (r = -0.515, P = 0.004). In 12 patients with proven rejection periods before the first investigation, normalized compliance was significantly lower (1.76 +/- 0.81 mmHg-1) than in those without rejection (2.95 +/- 1.22 mmHg-1, P = 0.005). Both the intimal index and the circumferential extension of the three-layered architecture of the vessel wall were significantly higher in recipients with rejection periods. A comparison of the subgroup of 13 recipients between first and second investigation showed that the intimal index increased slightly from 0.03 +/- 0.03 to 0.09 +/- 0.13 (ns) 71.8 weeks after transplantation, but that normalized compliance did not differ significantly between the first and the follow-up investigation. CONCLUSIONS: Early after orthotopic heart transplantation, normalized compliance does not correlate with donor age or the extent of atherosclerotic vessel alterations identifiable by intravascular ultrasound. Early rejection periods are associated with reduced coronary arterial compliance. Using intravascular ultrasound, this adverse functional effect on arterial compliance can be observed together with an increase in the intimal index.

Adult↗

[Conventional nuclear medical diagnosis in the after care of heart transplantation].

Actually more than 80% of heart recipients survive the first postoperative year. Early death is mainly caused by rejection and acute infection. After the first year progressive graft atherosclerosis has the greatest impact on prognosis. The review presents scintigraphic methods that have reached clinical impact in the diagnosis of rejection and vascular complications. Immunoscintigraphy with 111In-labelled monoclonal antibodies against myosin proved to be of importance in the diagnosis of rejection especially in long-term follow-up. Perfusion scintigraphy reveals vital and ischemic myocardium. In heart transplant recipients radionuclide ventriculography has been widely replaced by echocardiography. Up to now, the evaluation of increasing nerval integration with 123I-MIBG has not reached clinical impact.

Actuarial Analysis↗

Simultaneous evaluation of fatty acid metabolism and myocardial flow in an explanted heart.

UNLABELLED: The biodistribution of the fatty acid analog [131I]PHIPA 3-10, was compared to the flow tracer 99mTc-sestamibi by quantitative analysis in a dual-isotope study performed during a heart transplantation. METHODS: Iodine-131-PHIPA 3-10 and 99mTc-sestamibi were injected simultaneously approximately 20 min prior to the start of surgical procedure. Scintigraphic images of the sliced explanted heart were compared to the preoperative in vivo scans using [123I]PHIPA 3-10, 201TI and 99mTc-sestamibi. In 14 tissue samples of the explanted heart, the radioactive contents from [131I]PHIPA 3-10 and 99mTc-sestamibi were calculated as %ID/g-values and correlated with the corresponding histology. RESULTS: In the preoperative scans, a mismatch of fatty acid uptake and perfusion ([123I]PHIPA 3-10 > flow) was observed which indicated residual viable myocardium, while a matched defect was associated with scar. In viable myocardium, there was a significantly higher accumulation of [131I]PHIPA 3-10 compared to 99mTc-sestamibi (mean 5.9 x 10(-3) versus 2.7 x 10(-3)%ID/g),whereas in scars the uptake of both tracers was comparable (1.2 x 10(-3) versus 1.4 x 10(-3)%ID/g). CONCLUSION: Myocardial viability can be defined more accurately with radioiodinated PHIPA 3-10 than with 99mTc-sestamibi. The differences of biodistribution in viable myocardium and scars indicate that not only perfusion but also the metabolic state of the myocardium can be evaluated with radioiodinated PHIPA 3-10.

Coronary Circulation↗

[Intravascular sonographic findings after orthotopic heart transplantation: comparison with clinical factors].

30 patients (mean age 51.4 +/- 11.6 years; female n = 6) were studied early after orthotopic heart transplantation (11.6 +/- 5.5 weeks). Twelve recipients had undergone specific treatment for biopsy proven rejection. Using a mechanical intravascular ultrasound device (3.5-F catheter), 153 coronary artery segments (16 left coronary main stem, 122 left anterior descending artery, 15 left circumflex artery) were studied. Intimal index and circumferential extension of a three-layer appearance of the vessel wall were assessed. In all segments, systolic-diastolic changes in area (delta A) with respect to vessel area and pressure (delta P) were used to study normalized compliance (normalized compliance = [delta A/A]/delta P [mm Hg-1 x 10(3)]). Intravascular ultrasound findings were correlated to perioperative ischemia time, LDL/HDL-ratio, Lp(a) and donor age. In a subgroup of 13 recipients, intravascular ultrasound investigation was repeated after an interval of 67.4 +/- 10.2 weeks. At first investigation, mean intimal index of all coronary segments was 0.07 +/- 0.10. Mean circumferential extension of a three-layer appearance of the vessel wall was 84 +/- 112 degrees. Normalized compliance was 2.43 +/- 1.90 mm Hg-1 in the left main stem 2.45 +/- 1.47 mm Hg-1 within the left anterior descending artery, and 2.66 +/- 1.72 mm Hg-1 within the circumflex artery (differences n.s.). No correlation was found between intimal index and normalized compliance (r = -0.322), nor between circumferential extension of intimal thickening and normalized compliance (r = -0.362). Furthermore, there was no correlation between normalized compliance and donor age. Normalized compliance was significantly lower in recipients with proven rejection than in those without (1.76 +/- 0.81 versus 2.95 +/- 1.22 mm Hg-1, p = 0.005). Both, intimal index and circumferential extension of intimal thickening, were significantly higher in recipients following rejection periods (p < 0.05). The extent of coronary vessel wall alterations on ultrasound correlated to donor age but not to perioperative ischemia time, LDL/HDL-ratio and Lp(a). Re-investigation of a subgroup of 13 recipients 67.4 +/- 10.2 weeks after the first study showed an insignificant increase of the intimal index (from 0.03 to 0.09) and of the circumferential extension of intimal thickening (from 40 to 111 degrees). Normalized compliance changed from 2.53 +/- 1.48 to 2.87 +/- 1.33 mm Hg-1 (differences n.s.). Early after orthotopic heart transplantation, a significant correlation between atherosclerotic coronary vessel wall alterations assessed by intravascular ultrasound and donor age can be confirmed. Heart recipients following rejection periods present with significantly more atherosclerotic vessel wall alterations and a severely reduced compliance of the coronary vessels.

Adult↗

Clinical and invasive 7-month follow-up of a patient with a synthetic coronary graft.

The PossisR polytetrafluoroethylene Permaflow is a synthetic coronary graft which incorporates a Venturi resistor and which is anastomosed to the superior vena cava. Multiple anastomoses to the coronary vessels can be established in sequence until the graft is finally connected to the aorta. This aortocaval fistula enables permanent flow within the synthetic graft. We present the post-operative clinical and invasive findings of a 69-year-old female patient with a PossisR coronary graft. Follow-up angiography 3 and 7 months post-operatively showed patency of both coronary anastomoses and sufficient run-off to the native vessel segments. The left-right shunt induced by the graft was hemodynamically insignificant. Left ventricular function had improved significantly. 30 MHz intravascular ultrasound of the proximal part of the PossisR graft did not show an extra inner layer at the luminal side of the synthetic graft wall, so that relevant intimal thickening could be excluded after an interval of 7 months post implantation. Using an intravascular imaging technique, focal atherosclerotic lesions or thrombotic graft wall alterations could also be ruled out.

Aged↗

[Pulmonary varicose veins. Case report and review of the literature].

Pulmonary varicosis is a rare, presumably congenital localized dilatation of a pulmonary vein which is often associated with cardiac disease. We describe a case featuring enlargement of a pulmonary varix after mitral valve replacement, caused by mitral regurgitation, and discuss diagnostic possibilities, differential diagnosis and various development of this vascular malformation. A detailed review of the literature is given.

Adolescent↗

Successful long-term course after heart transplantation for anthracycline cardiomyopathy in a young boy despite neurological complications.

A now 14-year-old boy underwent orthotopic heart transplantation at the age of 13 for anthracycline cardiomyopathy which was a sequela of polychemotherapy for embryonal teratocarcinoma at the age of 1 year. Despite perioperative cerebellar infarction with signs of herniation which required emergency right cerebellar hemispherectomy the long-term course after 18 months turned out to be favorable with complete medical and psychosocial rehabilitation.

Adolescent↗

[Allograft vasculopathy in the early phase of orthotopic heart transplantation: angiography, intravascular ultrasound and functional in vivo findings].

Accelerated graft coronary atherosclerosis disease is the main reason for long-term mortality and morbidity of heart transplant recipients. The aim of this in vivo study was to evaluate coronary atherosclerotic vessel abnormalities and endothelial function using angiography, intravascular ultrasound, and intracoronary acetylcholine infusion. Fourteen patients (11 male, 3 female; mean age 49.3 years) were examined early after heart transplantation (mean interval after transplantation: 11 weeks) because of coronary artery disease (n = 8), idiopathic dilatative cardiomyopathy (n = 7), mitral valve replacement (n: 1) or left atrial filiae of a leiomyosarcoma (n = 1). Mean age of the donor hearts (female n = 8) was 29 years; 3 patients received double- and 14 patients triple-immunosuppression. All patients underwent biplane ventriculography and coronary angiography; a total of 120 coronary segments (main stem 21, left anterior descending artery 85, circumflex artery 14) was examined by intravascular ultrasound (20 MHz, 3.5 F catheters). In 13 patients, acetylcholine was infused into the proximal left anterior descending artery (0.15 microgram/min to 150.0 micrograms/min) to evaluate vasomotion within this segment. Ventriculography demonstrated regional wall abnormalities in 2 patients, angiography revealed 9 noncritical stenotic segments in 5 patients. Intravascular ultrasound detected 52 cross-sectional areas with a three-layer appearance indicating intimal thickening. Mean circumferential expansion of intimal proliferation was 192 degrees and mean intimal thickness was 0.35 mm. Only 5 segments of the sonographically pathological cross-sectional areas showed angiographic evidence of atherosclerotic lesions. After intracoronary infusion at a lower dose (0.15 and 1.5 micrograms/min) of acetylcholine, vasoconstriction was observed in 2 patients, at a dose of 15.0 and 150.0 micrograms/min in 10 patients. This response to acetylcholine did not depend on the intravascular or angiographical extent of atherosclerotic vessel abnormalities. In heart transplant recipients, coronary artery abnormalities can already be depicted at an early stage using intravascular ultrasound. The majority of patients show coronary vasoconstriction following infusion of acetylcholine at a higher dose. Further investigation is necessary to clarify whether the depicted vessel wall abnormalities can already be interpreted as newly developed graft atherosclerosis and whether abnormal vasomotion after acetylcholine is indicative of endothelial dysfunction.

Acetylcholine↗

[Hypertonic-hyperoncotic volume replacement (7.5% NaCl/10% hydroxyethyl starch 200.000/0.5) in patients with coronary artery stenoses].

OBJECTIVES: To determine the efficacy and safety of intravascular volume augmentation with a hypertonic saline-hyperoncotic HES solution prior to CABG. DESIGN: Randomized, double-blind, clinical trial. PATIENTS: Consecutive sample of 37 patients scheduled for elective CABG; mean age 64.5 (41-80; range) years and weight 74 (51-111) kg. INTERVENTIONS: Continuous, central-venous infusion of either 250 ml (approx. 3.5 ml/kg) HES (0.9% NaCl/10% hydroxyethyl starch 200.000/0.5) or HT-HES (7.5% NaCl/10% hydroxyethyl starch 200.000/0.5) in 15 minutes, following induction of anesthesia. MEASUREMENTS AND MAIN RESULTS: Groups were similar with respect to age, weight, and sex. 15 min. after fluid loading, cardiac index, pulmonary artery pressure, and wedge pressure had increased from baseline in both groups (p < 0.05), with a greater increase in the HT-HES-group (p < 0.05). In eight out of 18 patients, who had received HT-HES, transient drops in arterial blood pressure (mean 20% from baseline, range 10-35%) were observed during the first 5 minutes of infusion. Seven of the HT-HES-group patients developed transient left ventricular failure, predominantly 5-20 min. after infusion. No incidence of initial hypotension or LVF was observed in the HES-group. CONCLUSIONS: In patients with coronary artery disease, volume augmentation with hypertonic-hyperoncotic solutions may induce transient hypotension and post-infusion hypervolemic left heart failure.

Adult↗

Technique of aortic valve replacement with the Edwards stentless aortic bioprosthesis 2500.

Aortic valve replacement with a stentless device ought to result in superior hemodynamic function, because obstructing stents and sewing rims are eliminated. From 15 June 1991 to 15 October 1991, 15 patients underwent aortic valve replacement with the newly designed Edwards stentless aortic bioprosthesis 2500. Patients' ages ranged from 51 to 70 years (mean 61 years). Preoperatively 4 patients presented with aortic regurgitation, 7 with aortic stenosis and 4 with combined lesions; 7 patients were male and 8 female. No additional cardiac or noncardiac diseases were encountered. The operations were performed under normothermic extracorporeal cardiopulmonary bypass and cold cardioplegic cardiac arrest. The implanted valves ranged from 21 mm to 27 mm in diameter. Ten patients received a subcoronary implantation with the lower row of stitches made up of interrupted sutures and the upper row of a continuous suture. In 5 patients the so-called miniroot technique was used, also with lower interrupted sutures and running upper sutures, after adaptation of coronary ostia to the performed openings in the graft. Aortic cross-clamp time ranged between 73 min and 94 min (mean 82 min). There was no operative mortality or morbidity. Postoperative echocardiography showed no signs of aortic valve regurgation in any patient and continuous wave-Doppler measurements showed that resting pressure gradients across the aortic valve were absent or low. Our preliminary experiences with a stentless aortic xenograft valve show that in presence of an increased cross-clamp time an improved hemodynamic function will be obtained. Further studies will be needed, however, to establish the long-term behavior of this device.

Aortic Valve Insufficiency↗