Search PubMed⌕ Search

Biomedical subjects

M Wendt

Publications and source records attributed to M Wendt.

At least 55 records · Page 3Linked to original sources

No risk of metal toxicity in combined spinal-epidural anesthesia.

UNLABELLED: Using the single level needle-through-needle technique for combined spinal-epidural anesthesia (CSE) may introduce very fine metal particles abraded by the spinal needle from the inner ground edge of the Tuohy needle into the patient. Either the local anesthetic administered epidurally or the peridural catheter may also pass intrathecally through the hole in the dura made by the spinal needle. To examine these concerns, the needle-through-needle technique was simulated in an in vitro model (18-gauge Tuohy needle; 27- or 29-gauge Quincke needle). The presence of abraded metal particles was identified by atomic absorption spectrography (AAS). The needles were then examined under an electron microscope. Metal particles could not be identified by using AAS in the needle-through-needle technique after normal clinical use, nor could traces of use be revealed by using an electron microscope to examine the Tuohy needle. With intentionally rough handling and caudal orientation of the spinal needle tip, minimal scratches could be seen by using an electron microscope, but there were no metal particles detected by AAS. In an anatomical preparation, the possible passage of the epidural catheter anesthetic through the dural puncture hole into the cerebrospinal fluid compartment was investigated endoscopically. Neither passage of dyed epidural local anesthetic nor penetration of the epidural catheter into the cerebrospinal fluid compartment could be demonstrated by endoscopy. We conclude that the needle-through-needle-technique is an acceptable way of performing CSE anesthesia. Endangering the patient by an unintentionally intrathecal misplacement of the epidural catheter seems to be very unlikely based on our in vitro model if small spinal needles (27- or 29-gauge) are used. IMPLICATIONS: Atomic absorption spectrography shows no contamination of the intrathecal compartment by abraded metal particles from the Tuohy needle by combined spinal-epidural anesthesia with the needle-through-needle technique. In vitro, neither passage of dyed epidural local anesthetic nor penetration of the epidural catheter into the cerebrospinal fluid compartment could be demonstrated by endoscopy.

Anesthesia, Epidural↗

[Pulse sequences and visualization of instruments].

While initially advocated primarily for intrasurgical visualization (e.g., craniotomy), interventional MRI rapidly evolved into roles in image-guided localization for needle-based procedures, and thermal ablation of cancer. In this contest, MRI pulse sequences and scanning methods serve one of four primary roles: (1) speed improvement, (2) device localization, (3) anatomy/lesion differentiation and (4) temperature sensitivity. The first part of this manuscript deals with passive visualization of MR-compatible needles and the effects of field strength, sequence design, and orientation of the needle relative to the static magnetic field of the scanner. Issues and recommendations are given for low-field as well as high-field scanners. The second part contains methods reported to achieve improved acquisition efficiency over conventional phase encoding (wavelets, locally focused imaging, singular value decomposition and keyhole imaging). Finally, the last part of the manuscript reports the current status of thermosensitive sequences and their dependence on spinlattice relaxation time (T1), were diffusion coefficient (D) and proton chemical shift (delta).

Animals↗

[MRI-assisted bile duct drainage: evaluation of passive catheter imaging in an animal model].

PURPOSE: To investigate interactive MR-assisted bile duct drainage in pigs with the passive visualization technique using near real-time imaging. METHODS: 8 bile duct drainages were placed in an open low-field MR system (0.2 Tesla) in 4 pigs with surgically induced cholestasis. After planning the intervention with magnetic resonance cholangiography (MRC), both the puncture and catheter placement were interactively guided using a fast T2-weighted true FISP sequence. RESULTS: MRC enabled interventional planning in all puncture attempts. Punctures were unproblematic in all attempts, the bile ducts were punctured 6 times after the first and twice after the second attempt. Placement of the passively visible catheter was successful in all animals. The applied sequence enables interactive fluoroscopy-like positioning of the devices. CONCLUSION: The procedure introduced here enables reliable and fast placement of a bile duct drainage in an animal model using a low-field MR system.

Animals↗

[Ventilation-perfusion distribution with volume-reduced, pressure-limited ventilation with permissive hypercapnia].

PURPOSE: Low volume pressure-limited ventilation with permissive hypercapnia (PH) may decrease the mechanical stress of the lung in acute respiratory insufficiency. Alveolar PCO2 is a determinant of regional ventilation, whereas increased mixed-venous and arterial PCO2 may affect systemic and pulmonary haemodynamics. The aim of this study was to analyse the ventilation-perfusion (VA/Q) distribution during controlled ventilation with permissive hypercapnia. METHODS: The study was approved by the ethical committee of the Ernst-Moritz-Arndt University of Greifswald. Eleven patients with severe ARDS (lung injury severity score 2.77 +/- 0.47) were studied. Intrapulmonary shunt (QS/QT, % of QT), lung areas with 0.005 < or = VA/Q < or = 0.1 ("low" VA/Q, % of QT), lung areas with 10 < or = VA/Q < or = 100 ("high" VA/Q, % of VE), dead space ventilation (VD/VT = VA/Q > 100, % of VE) and the mean distribution of ventilation (Vmean VA/Q) and perfusion (Qmean VA/Q) were determined by the multiple inert gas elimination technique during normocapnic (NC) and hypercapnic (HC) mechanical ventilation. In addition, systemic mean arterial and pulmonary arterial pressure, cardiac output (CO) and arterial and mixed venous partial pressures for oxygen (PaO2, PvO2) and carbondioxide (PaCO2, PvCO2) were assessed. RESULTS: Low-volume pressure-limited ventilation was associated with moderate hypercapnia (PaCO2 = 61 +/- 12 mmHg vs. 39 +/- 6 mmHg, p < 0.01). QS/QT increased (28 +/- 16% [NC] vs. 36 +/- 17% [HC], p < 0.05), whereas Qmean VA/Q decreased from 1.01 +/- 0.37 (NC) to 0.65 +/- 0.49 (HC), (p < 0.01) and Vmean VA/Q decreased from 1.54 +/- 0.58 (NC) to 1.12 +/- 0.93 (HC) (p < 0.05). Hypercapnia induced mild systemic hypotension and pulmonary hypertension. CO increased from 10.8 +/- 2.3 l/min to 11.6 +/- 2.6 l/min (p < 0.05). PaO2 was almost unchanged, but PvO2 increased significantly from 40 +/- 4 mmHg (NC) to 49 +/- 7 mmHg (HC) (p < 0.01). CONCLUSION: The mechanical ventilation with permissive hypercapnia may increase shunt due to alveolar derecruitement and an impaired hypoxic pulmonary vasoconstriction. PaO2 was unchanged due to an increased CO, PvO2 and--to a lesser extent--shift of the oxyhaemoglobin dissociation curve.

Adult↗

[Dissociative stupor--differential diagnosis of coma following injury].

Two cases are described in which a dissociative stupor originating from conversion neurosis simulated a coma following a sustained trauma. At first both patients showed no response to being addressed or to pain stimuli. They presented an upward eye gaze deviation, cardiorespiratory functions were stable. Following extensive diagnostic procedures revealing no organic cause for the clinical symptoms, the diagnosis of a hysterical consciousness disorder was stated. Symptoms of conversion neuroses include lacking call response, gait disorder, seizure-like conditions and strength diminution in one or more extremities. In these cases suspicious facts are the absence of injuries (for example by falling down or tongue bite during a dissociative attack), eye gaze deviation and the phenomenon that, when the patient's arm is raised above the head and let fall, it never hits the face but glides down beside the body.

Adult↗

The effect of dopexamine on ventilation perfusion distribution and pulmonary gas exchange in anesthetized, paralyzed patients.

UNLABELLED: We studied the effects of the beta2-adrenoceptor and DA1-receptor agonist dopexamine on ventilation perfusion (V(A)/Q) distribution in anesthetized, paralyzed patients (n = 17) undergoing major abdominal surgery. Intrapulmonary shunt (Q(S)/Q(T)) (percentage of cardiac output [CO]), perfusion of low V(A)/Q areas (percentage of CO), ventilation of high V(A)/Q areas (percentage of total ventilation [V(E)]), and dead space ventilation [percentage of V(E)]) were calculated from the retention/excretion data of six inert gases. In the control state, Q(S)/Q(T) was 11% +/- 9% (mean +/- SD) and little perfusion of low V(A)/Q areas (3% +/- 4%) was observed. Infusion of 1.0 microg kg(-1) x min(-1) dopexamine had no effect on Q(S)/Q(T) and low V(A)/Q areas despite an increased CO (7.7 +/- 2.2 L/min versus 6.2 +/- 1.2 L/min; P < 0.01). Pao2 increased from 15.5 +/- 5.6 kPa (116 +/- 42 mm Hg) to 17.3 +/- 6.3 kPa (130 +/- 47 mm Hg) (P < 0.05). Infusion of 2.0 microg x kg(-1) x min(-1) dopexamine further increased CO to 8.4 +/- 2.7 L/min (P < 0.01) without alterations of Q(S)/Q(T), perfusion of low V(A)/Q areas, and Pao2. We concluded that dopexamine (1.0 microg x kg(-1) x min(-1) and 2.0 microg x kg(-1) x min(-1)) has no adverse effects on V(A)/Q relationships and Q(S)/Q(T) in anesthetized, paralyzed patients. IMPLICATIONS: The I.V. administration of vasoactive drugs can improve oxygen delivery to different organ systems but may impair pulmonary gas exchange. In anesthetized, paralyzed patients, we studied the effects of beta2-adrenoceptor and DA1-receptor agonist dopexamine on ventilation perfusion distribution. Dopexamine (1.0 microg x kg(-1) x min(-1) and 2.0 microg x kg(-1) min(-1)) improved cardiac output and oxygenation without alterations of intrapulmonary shunt.

Adrenergic beta-Agonists↗

In vitro investigation of cerebrospinal fluid leakage after dural puncture with various spinal needles.

UNLABELLED: Postspinal headache is one of the most common complications of spinal anesthesia and has repeatedly led to controversy concerning needle size and configuration. In an in vitro investigation, we measured cerebrospinal fluid (CSF) leakage with Sprotte, Whitacre, Quincke, and Atraucan needles under physiological conditions in human dura. The puncture characteristics were examined under an electron microscope. The pencil-point needles show 2-3 times less leakage of CSF compared with the cutting Quincke needles of corresponding size. Between the Sprotte and the Whitacre needles, there were no significant differences. The least loss of CSF occurred with the 26-gauge Atraucan needle. Under the electron microscope, a sharply delineated, persistent perforation channel was shown with the Quincke needles, which may explain the high CSF loss. With pencil-point needles, which push the tissue apart bluntly, a large opening on the inside is found, with some tearing of the dura. However, in contrast to the cutting needles, a persistent perforation channel is not manifested. The 26-gauge Atraucan needle, which both cuts and pushes apart conically, shows a relatively discrete opening on the inside, with slight tears in the dura and arachnoidea but without a visible perforation channel. The results of our study show that larger needles (26-gauge Atraucan) that are easier to handle can lead to good and, in some cases even better, puncture results if they have characteristics of both the cutting and the pencil-point needles. IMPLICATIONS: We compared several brands of pencil-point and standard cutting spinal needles of varying sizes. All pencil-point needles had less cerebrospinal fluid leakage, the least loss occurring with 26-gauge Atraucan needles. Electron microscopic examination of the dura after puncture showed characteristic findings with each needle type. We conclude that the combined cutting and pencil-point characteristics seen in the Atraucan needle may have clinical advantages.

Cerebrospinal Fluid↗

Methods for providing probe position and temperature information on MR images during interventional procedures.

Interventional magnetic resonance imaging (MRI) can be defined as the use of MR images for guiding and monitoring interventional procedures (e.g., biopsy, drainage) or minimally invasive therapy (e.g., thermal ablation). This work describes the development of a prototype graphical user interface and the appropriate software methods to accurately overlay a representation of a rigid interventional device [e.g., biopsy needle, radio-frequency (RF) probe] onto an MR image given only the probe's spatial position and orientation as determined from a three-dimensional (3-D) localizer used for interactive scan plane definition. This permits 1) "virtual tip tracking," where the probe tip location is displayed on the image without the use of separate receiver coils or a "road map" image data set, and, 2) "extending" the probe to predict its path if it were directly moved forward toward the target tissue. Further, this paper describes the design and implementation of a method to facilitate the monitoring of thermal ablation procedures by displaying and overlaying temperature maps from temperature sensitive MR acquisitions. These methods provide rapid graphical updates of probe position and temperature changes to aid the physician during the actual interventional MRI procedures without altering the usual operation of the MR imager.

Animals↗

Dynamic tracking in interventional MRI using wavelet-encoded gradient-echo sequences.

This work describes a newly developed magnetic resonance imaging (MRI) data-acquisition strategy which replaces the standard Fourier phase-encoding with the spatially localized coefficients of wavelet-encoding and offers a new technique for image guidance when combined with a dynamic tracking algorithm. By using this new technique, only a specific fraction of the entire raw data set needs to be updated and reconstructed to visualize the movement of an interventional device during an MR guided procedure. The combination of wavelet-encoding and a dynamic tracking algorithm was implemented in two-dimensional and three-dimensional gradient-echo sequences on a 0.2-T open C-arm-shaped MR system (Siemens, Erlangen Germany) and tested in phantom and in vitro experiments. When applying the wavelet-encoding direction parallel to the movement of a straight interventional device, only those spatially localized wavelet-coefficients mainly affected by the interventional device are updated. This led to potential increases of the image frame rate by a factor of up to seven.

Animals↗

Intrathoracic and pulmonary blood volume during CO2-pneumoperitoneum in humans.

BACKGROUND: Induction of CO2-pneumoperitoneum may have significant effects on systemic and pulmonary haemodynamics. We hypothesized that intrathoracic (ITBV) and pulmonary blood volume (PBV) are affected during intra-abdominal CO2-insufflation, which may be pronounced by positional changes of the patient. METHODS: Sixteen anaesthetized patients were studied before, during and after CO2-pneumoperitoneum for laparoscopic cholecystectomy. A dye indicator technique was used to assess ITBV and PBV. In addition, gas exchange and haemodynamics were recorded. RESULTS: In the supine position, induction of CO2-pneumoperitoneum had no effects on ITBV, PBV and cardiac output. Mean systemic arterial pressure increased from 10.9 +/- 1.5 kPa (82 +/- 11 mmHg) to 12.7 +/- 1.5 kPa (95 +/- 11 mmHg, P < 0.01). In the reverse Trendelenburg position ITBV decreased from 19.8 +/- 5.1 ml.kg-1 to 16.7 +/- 3.7 ml.kg-1 (P < 0.05) during CO2-insufflation, but increased to control values after 20 min. PBV decreased from 4.2 +/- 1.2 ml.kg-1 to 3.4 +/- 1.1 ml.kg (P < 0.05) and remained decreased during CO2-pneumoperitoneum. Calculated venous admixture was unchanged throughout the study. Deflation of CO2-pneumoperitoneum increased ITBV (22.4 +/- 5.2 ml.kg-1, P < 0.05) and cardiac output above control values. CONCLUSIONS: In anaesthetized-paralyzed patients in the reverse Trendelenburg position intra-abdominal CO2-insufflation is associated with significant alterations of ITBV and PBV. The release of CO2-pneumoperitoneum is associated with a re-distribution of blood into the thorax.

Abdomen↗

Histology and ultrastructure of the urothelium lining the ureter and the renal pelvis in sows.

The histology and ultrastructure of the urothelium lining the ureter and renal pelvis in sows was examined using light microscopy, and scanning and transmission electron microscopy. The epithelium of both the ureter and the renal pelvis were similar and consisted of the basal, the intermediate and the superficial cells. The luminal surface of the superficial cells was characterized by microplicae. Transmission electron microscopy showed that the luminal membrane of these cells showed trilaminar asymmetric unit membrane. Tight junctions linked the lateral parts of the superficial cells, while the intermediate and the basal cells were connected to each other and the basal cells with the basal membrane through desmosomes and hemidesmosomes, respectively. Clusters of mitochondria were observed throughout the urothelium. Unlike that of the basal cells, the Golgi complex and the endoplasmic reticulum were well developed in the superficial and intermediate cells. Lysosomes and vesicles were observed only in the superficial and the intermediate cells. Fine cytoplasmic filaments, although very few in the basal cells, were observed throughout the epithelium. The results are compared and discussed with the findings reported on the urotherlium of other mammalian species and humans.

Animals↗

Delayed low density lipoprotein (LDL) catabolism despite a functional intact LDL-apolipoprotein B particle and LDL-receptor in a subject with clinical homozygous familial hypercholesterolemia.

We identified a 38-yr-old male patient with the clinical expression of homozygous familial hypercholesterolemia presenting as severe coronary artery disease, tendon and skin xanthomas, arcus lipoides, and joint pain. The genetic trait seems to be autosomal recessive. Interestingly, serum concentrations of cholesterol responded well to diet and statins. We had no evidence of an abnormal low density lipoprotein (LDL)-apolipoprotein B (apoB) particle, which was isolated from the patient using the U937 proliferation assay as a functional test of the LDL-binding capacity. The apoB 3500 and apoB 3531 defects were ruled out by PCR. In addition, we found no evidence for a defect within the LDL-receptor by skin fibroblast analysis, linkage analysis, single-strand conformational polymorphism and Southern blot screening across the entire LDL-receptor gene. The in vivo kinetics of radioiodinated LDL-apoB were evaluated in the proband and three normal controls, subsequently. The LDL-apoB isolated from the patient showed a normal catabolism, confirming an intact LDL particle. In contrast the fractional catabolic rate (d-1) of autologous LDL in the subject and the normal controls revealed a remarkable delayed catabolism of the patient's LDL (0.15 vs. 0.33-0.43 d-1). In addition, the elevation of LDL-cholesterol in the patient resulted from an increased production rate with 22.8 mg/kg per day vs. 12.7-15.7 mg/kg per day. These data indicate that there is another catabolic defect beyond the apoB and LDL-receptor gene causing familial hypercholesterolemia.

Adult↗

[Application of the laryngeal mask for elective percutaneous dilatation tracheotomy].

Percutaneous dilatational tracheostomy is an increasingly accepted procedure for bed-side tracheostomy. The exact positioning of the endotracheal tube, the localization of the point for puncturing the trachea and damage to the endotracheal tube and the cuff as well as to the bronchoscope due to the puncturing process are technical problems which can endanger the course of the operation. In a prospective randomized study, we examined whether use of the laryngeal mask airway (LMA) is a real alternative to the endotracheal tube during tracheostomy. Of 48 consecutive patients only 43 fulfilled all criteria for this study: PaO2 > 100 mmHg, PaCO2 < 45 mmHg (in patients with head injury < 35 mmHg) under intermittent positive pressure ventilation (IPPV) with a mean ventilation pressure of < 25 mmHg and an FiO2 of 1.0. Patients with intestinal obstruction, hemorrhages of the mouth and nose and unfavourable anatomic conditions were not included in this study. Three more patients had to be excluded from the study because of technical problems. In 21 patients tracheostomy was performed using an endotracheal tube (ET group) and in 19 patients using a LMA (LM group). After positioning of the endotracheal tube or the LMA, tracheostomy was performed in the usual way. Arterial blood gases (PaO2 and PaCO2) were investigated before positioning of the endotracheal tube or the LMA, five minutes after this procedure and five minutes after the end of tracheostomy. Mean arterial pressure (MAP), heart frequency (HF) and peripheral oxygen saturation (SpO2), endexpiratory CO2 partial pressure (PetCO2) and minute ventilation volume (MVV) were registered every 60 seconds. The ET group and LM group did not differ regarding basic diseases, age and severity of illness. Before the beginning of tracheostomy, there were no differences in MAP, HF, SpO2, PetCO2 and PaCO2 between the two groups. Before tracheostomy, only PaO2 was significantly higher in the LM group than in the ET group. Immediately before the insertion of the tracheal cannula and five minutes after the end of tracheostomy, there were no differences in the measured parameters of the two groups. An increase in PetCO2 and a decrease in minute ventilation volume were observed in both groups. Regarding technical complications, the LMA is a safe alternative to the endotracheal tube. The choice of method should depend on the basic disease and the patient's ventilation requirements at the time of tracheostomy, while there is still a call for safe instruments guaranteeing sufficient sealing of the respiratory tract during the dilatational tracheostomy and simultaneous avoidance of technical problems during puncturing of the trachea and widening of the point of puncturing.

Adult↗

Primer design for a prokaryotic differential display RT-PCR.

We have developed a primer set for a prokaryotic differential display of mRNA in the Enterobacteriaceae group. Each combination of ten 10mer and ten 11mer primers generates up to 85 bands from total Escherichia coli RNA, thus covering expressed sequences of a complete bacterial genome. Due to the lack of polyadenylation in prokaryotic RNA the type T11VN anchored oligonucleotides for the reverse transcriptase reaction had to be replaced with respect to the original method described by Liang and Pardee [ Science , 257, 967-971 (1992)]. Therefore, the sequences of both the 10mer and the new 11mer oligonucleotides were determined by a statistical evaluation of species-specific coding regions extracted from the EMBL database. The 11mer primers used for reverse transcription were selected for localization in the 3'-region of the bacterial RNA. The 10mer primers preferentially bind to the 5'-end of the RNA. None of the primers show homology to rRNA or other abundant small RNA species. Randomly sampled cDNA bands were checked for their bacterial origin either by re-amplification, cloning and sequencing or by re-amplification and direct sequencing with 10mer and 11mer primers after asymmetric PCR.

Bacteria↗

Decorin and suramin inhibit ocular fibroblast collagen production.

BACKGROUND: The process of ocular wound healing with respect to glaucomatous filtering procedures is of current interest. Delaying this response in patients could possibly lead to more favorable surgical results. So far, only highly toxic antimetabolites have come into frequent clinical use. The possible efficacy of other groups of substances such as growth factor inhibitors has not yet been examined in vitro. METHODS: We exposed Tenon's capsule fibroblasts in tissue culture to various concentrations of decorin and suramin. The dose responses of type I and type III collagen to these inhibitors were measured using an ELISA-type dot blot assay. Total cellular protein production was assayed by measuring the incorporation of tritiated leucine. RESULTS: At a concentration of 10 micrograms/ml, suramin reduced the collagen production by more than 80%. Decorin, at a concentration of 100 micrograms/ml, reduced type I collagen production by about 50% while type III collagen was reduced by 80%. At these concentrations, the total cellular protein production was not inhibited. CONCLUSIONS: Both suramin and decorin, which specifically inhibit the action of growth factors on target cells, reduce the production of collagen synthesis by Tenon's capsule fibroblasts. This is a specific effect, because total protein production is not influenced. This sets these substances apart from antimetabolites. Decorin and suramin may have clinical relevance in that they appear to interfere with ocular wound healing more specifically than the substances so far frequently used.

Antineoplastic Agents↗

[Circulatory reactions under spinal anesthesia. The catheter technique versus the single dose procedure].

UNLABELLED: Life-threatening cardiovascular complications are a serious risk even for healthy patients during spinal/epidural anaesthesia. The incidence of fatal cardiovascular complications for epidural anaesthesia is 1:10000, for spinal anaesthesia 1:7000. In contrast, general anaesthesia has an overall mortality of only 1:28000. Administration of IV fluids to minimise the haemodynaemic reactions of beginning sympatholysis is not always sufficient. In this study, we examined whether fractionated application of local anaesthetics via a spinal catheter would provide better haemodynamic stability. METHODS: In a prospective study, we examined the haemodynaemic reactions of 300 patients during single-dose (n = 150) versus continuous spinal anaesthesia (CSA) (n = 150). Isobaric bupivacaine 0.5% was given through a 29 G Quincke needle (3.5 ml) or a 28 G spinal catheter (1.5 ml as a bolus, followed by 1 ml/10 min until an anaesthetic level of T12 was reached). RESULTS: The sensory and motor effects of both methods were comparable. The T12 level of anaesthesia was achieved with the single-dose method after 10.5 min and with the continuous method after 19.1 min. After single-dose anaesthesia, the blood pressure dropped by 16.5% and the heart rate by 12% compared to the control values. During CSA no significant blood pressure changes were recorded; the heart rate decreased by 8%. In 15 cases vasoconstrictors had to be given to stabilise the lowered blood pressure after single-dose anaesthesia. CONCLUSION: With the use of CSA, the haemodynamic effects of sympatholysis can be minimised. This method thus has advantages, especially for high-risk cardiovascular patients.

Adult↗