Search PubMed⌕ Search

Biomedical subjects

M Watanuki

Publications and source records attributed to M Watanuki.

48 records · Page 3Linked to original sources

Purification and properties of cytochrome p-450 (11beta- and 18-hydroxylase) from bovine adrenocortical mitochondria.

We describe an improved procedure for the preparation of a cytochrome P-450 from bovine adrenocortical mitochondria which catalyzes 11beta- and 18-hydroxylation of steroids. The preparation is based upon chromatography on DEAE cellulose which separates the enzyme from the side-chain cleavage P-450, which can also be prepared in highly purified form from the same tissue extracts. The enzyme behaves as a single compound in glycerol density gradients. The enzyme aggregates at protein concentrations greater than 1 mg/ml to a series of forms of various molecular weights. On Sepharose 4B the enzyme shows a molecular weight of 185 000, while on glycerol density gradients a molecular weight of 1 - 10(6) is observed. The subunit molecular weight determined by electrophoresis on polyacrylamide gels with sodium dodecyl sulfate is 47 500 and the protein appears as a single band. The ratio of 11beta-/18-hydroxylase activities does not change significantly during purification and is constant through the protein peak on glycerol density gradients. Since there appears to be only one subunit species, it seems likely that the two hydroxylase activities are catalyzed by one protein.

Adrenal Cortex↗

The statistical distribution of macrophage migration distance and its application to MIF test.

The measurement of the distance of macrophage migration is very simple and reasonable as a technique in MIF assay. By the use of this technique, a large scale model experiment was performed and its data were analysed statistically. As the result of analysis, Student's t-test for significance of the difference between control and test readings of migration distance at low activity level in the MIF test was justified, and it was proved that it is applicable to the routine MIF test. In addition to this, the measurement of migration distance was compared with that of migration area.

Animals↗

Development of continuous recirculating peritoneal dialysis using a double lumen catheter.

Continuous recirculating peritoneal dialysis (CRPD) was newly introduced to improve solute removal efficiency in conventional dialysis therapies such as hemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD). In CRPD, a part of the dialysate in the peritoneal cavity was drained through a double-lumen catheter and purified by an extracorporeal dialyzer. Urea removal characteristics in CRPD were examined in a canine study. In this study, a recirculation-dialysis experiment using a dog weighing 9.0 kg was carried out under 100 and 200 ml/min of flow for recirculating and delivered dialysates, respectively. An FB-50H (Nipro Medical Industries, Ltd., Osaka, Japan) composed of cellulose diacetate membrane with 0.5 m2 of surface area and Dianeal-1.5 (Baxter Limited Laboratories, Tokyo, Japan) containing urea were used as the extracorporeal dialyzer and dialysate. Urea peritoneal and dialyzer dialysances (DBP and DBD) were 3.05 and 33.3 ml/min by computer simulation using a compartment model for CRPD. This DBP value can be estimated as 20.3 ml/min for a 60 kg human. From this result, time-averaged value for BUN over an 8 hr/day CRPD, combined with three exchanges/day as CAPD is estimated to be 34.3 mg/dl, which is much lower than 45.2 mg/dl for a 12 hr/week HD, or 53.0 mg/dl for conventional CAPD.

Animals↗