Search PubMed⌕ Search

Biomedical subjects

M V Marx

Publications and source records attributed to M V Marx.

43 records · Page 3Linked to original sources

Cholecystojejunostomy varices demonstrated by enteroclysis.

Varices in unusual sites constitute a minor but significant cause of gastrointestinal bleeding in patients with liver disease. We report a case of varices across the anastomotic line between the jejunum and gallbladder after cholecystojejunostomy. Although such varices have been demonstrated by angiography, to our knowledge they have never been demonstrated by small bowel enema (enteroclysis). We report a case and describe the findings on enteroclysis.

Anastomosis, Surgical↗

Creation of reentry tears in aortic dissection by means of percutaneous balloon fenestration: gross anatomic and histologic considerations.

PURPOSE: To study the safety and efficacy of percutaneous fenestration in aortic dissection, transmural tears in canine and human aortae were created with conventional angioplasty balloons. MATERIALS AND METHODS: Tears created in the aortae of five living dogs were compared with tears created in postmortem specimens. Percutaneous fenestration was performed in a woman with acute type I dissection and ischemic hepatitis who died in multisystem failure, and the balloon tear was documented at autopsy. Additional tears in the human aorta were studied in necropsy specimens of normal, Marfanoid, atherosclerotic, and acutely and chronically dissected thoracic and abdominal aortae. RESULTS: In the canine aorta, transmural balloon tears resulted in rapid death of all five animals, and the tears were approximately 10% longer than tears created post mortem with the same balloon. In human aortic specimens, most transmural and all transseptal tears were linear and were oriented nearly perpendicular to the longitudinal axis of the aorta. Tears that were initiated near calcified plaques or large aortic branches extended in unpredictable directions. The transverse orientation of the tears coincided with the long axis of smooth muscle cells in the media of the intact aorta or the dissection septum. CONCLUSION: Percutaneous balloon fenestration, when performed in areas of the aorta relatively free of atherosclerosis, results in transverse tears in the aortic dissection septum. Percutaneous fenestration of the aortic dissection septum appears feasible and should be considered as a treatment option in carefully selected cases of aortic dissection with ischemic complications. A final conclusion regarding the safety and efficacy of percutaneous fenestration undertaken to relieve organ ischemia requires further clinical experience.

Aged↗

Canine model of acute aortic rupture: treatment with percutaneous delivery of a covered Z stent--work in progress.

PURPOSE: To develop a percutaneous treatment for aortic rupture with use of a covered intraluminal stent. MATERIALS AND METHODS: A transmural tear was created percutaneously in the thoracic aorta in six dogs with use of a 4-mm angioplasty balloon. Gianturco Z stents were covered with polytetrafluoroethylene, loaded into a 14-F sheath, and advanced through the femoral artery to the site of injury. Within 2 minutes after initiation of the injury, the stent was deployed. Homologous canine blood was given during the procedure. Dogs that survived 24 hours were then killed. RESULTS: The first stent did not expand completely, and the dog died in 1 hour. At necropsy, the first two dogs (1-hour and 8-hour survival) had a large left hemothorax and extensive periaortic hematoma, indicating intrathoracic exsanguination. The next four dogs were treated with a modified stent and survived 2 hours (n = 1), 8 hours (n = 1), and 24 hours (n = 2). At necropsy hemothorax did not exceed 15 mL, and periaortic hematomas were small. The cause of death in the two early casualties with the modified stent is uncertain. There were no signs of spinal cord injury despite occlusion of three pairs of intercostal arteries. CONCLUSION: The covered Z stent (in its modified form) tamponaded the aortic tear, preventing exsanguination. Long-term studies of biocompatibility of this device appear justified.

Acute Disease↗

Percutaneous feeding tube placement in pediatric patients: immediate and 30-day results.

PURPOSE: To evaluate fluoroscopically guided percutaneous feeding tube placement in pediatric patients. MATERIALS AND METHODS: Sixty-one procedures were performed. Periprocedural care protocol was changed after patient nine. Forty-eight-hour and 30-day outcomes were assessed. RESULTS: Almost 97% of procedures were successful. The 48-hour major and minor complication rates were 1.9% and 9.6%, respectively, after the initial nine procedures. Risk factors for early complications were the use of the initial care protocol (P < .01) and patient weight below the 50th percentile (P < .05). Major and minor 30-day complication rates were 8.3% and 12.0%, respectively. Risk factors for delayed complications were placement of a gastrojejunostomy tube rather than a gastrostomy tube (P < .05) and immunosuppression (P < .05). CONCLUSION: Percutaneous feeding tubes can be placed in children with a high rate of technical success. Optimal results require attention to periprocedural care. Morbidity is common during the first month of tube use.

Child↗

Evaluation of a new percutaneous stainless steel Greenfield filter.

PURPOSE: To evaluate a new percutaneous Greenfield filter with an alternating hook design and over-the-wire delivery system. MATERIALS AND METHODS: The alternating hook stainless steel Greenfield filter was evaluated in a prospective clinical trial between March 10, 1994, and January 27, 1995. Filters were placed in 75 patients in nine clinical centers and follow-up with radiographs and ultrasound scans was carried out at 30 days. RESULTS: Clinical trial results revealed successful placement in all patients. There were four cases of filter limb asymmetry (5.3%) without clinical sequelae, with one incidence of failure to span the cava. No significant migration was found. There were no clinically suspected pulmonary emboli, but one instance of probable caval penetration (1.7%) did occur. Caval occlusion was documented in three patients (5%). CONCLUSION: The percutaneous stainless steel Greenfield filter provides ease of insertion and improved deployment while maintaining the high standards of efficacy and safety associated with the standard and titanium Greenfield filters.

Adult↗

The dissected aorta: percutaneous treatment of ischemic complications--principles and results.

PURPOSE: Describe the principles and results of percutaneous treatment of ischemic complications of aortic dissection. MATERIALS AND METHODS: Twenty-four patients with aortic dissection complicated by ischemic compromise of the liver or bowel (n = 15), kidney (n = 18), or lower extremity (n = 13) were evaluated by means of aortography, intravascular ultrasound, and manometry, and were treated percutaneously. Visceral arteries were classified as obstructed or nonobstructed. Obstruction was classified as static, in which the dissecting hematoma extended into and narrowed the lumen of a branch artery, or dynamic, in which the dissection flap prolapsed into the vessel origin or narrowed the true lumen (TL) above it. Treatment consisted of vascular stents alone (n = 4), or balloon fenestration (n = 20) without (n = 8) or with (n = 12) vascular stents. RESULTS: Obstruction was present in 77 arteries and was static in 12 arteries, dynamic in 45 arteries, static and dynamic in 17 arteries, and indeterminate in three arteries. Percutaneous treatment did not alter false lumen (FL) pressure, but reduced the peak systolic interluminal pressure gradient from 28 mm Hg to 2 mm Hg and restored flow in 71 of 77 arteries (92%). Six patients died within 30 days (25% operative mortality), none as a result of the procedure. Two additional patients died in follow-up from complications of an expanding FL. Technical complications in two patients due to altered hemodynamics after initial intervention were recognized and corrected percutaneously during the same procedure. CONCLUSIONS: Percutaneous fenestration and endovascular stent deployment are indicated to restore blood flow to arteries compromised by aortic dissection. The prognosis of patients is related to the ischemic injury sustained prior to the percutaneous interventional procedure and, in patients with acute type I dissection who have not undergone surgery, to the preoperative stability of the FL.

Adult↗