[Detection of the hemodynamic effects of renal artery stenosis with MRI flow measurement].

Data derived from the MR-CINE phase-contrast flow measurement of renal arteries correlates well with the angiographically detected degree of stenosis and scintigraphic measurements. MR data permit the quantitative analysis of altered hemodynamics and MR is a non-invasive substitute for angiography preoperatively and during follow-up. Angiography is indicated only for the evaluation of morphological criteria.

Adolescent↗

Nuclear magnetic resonance imaging with hyperpolarised helium-3.

BACKGROUND: Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. METHODS: A volunteer inhaled hyperpolarised 3He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 10(5) times larger than the polarisation of water protons. This enormous gain in polarisation easily overcomes the loss in signal due to the lower density of the gas. FINDINGS: The in-vivo experiment was done in a whole-body MRI scanner. The 3He image showed clear demarcation of the lung against diaphragm, heart, chest wall, and blood vessels (which gave no signal). The signal intensity within the air spaces was greatest in lung regions that are preferentially ventilated in the supine position; less well ventilated areas, such as the apices, showed a weaker signal. INTERPRETATION: MRI with hyperpolarised 3He gas could be an alternative to established nuclear medicine methods. The ability to image air spaces offers the possibility of investigating physiological and pathophysiological processes in pulmonary ventilation and differences in its regional distribution.

Adult↗

Improved visualization of breast lesions with gadolinium-enhanced magnetization transfer MR imaging.

A pulse sequence with magnetization transfer as the main contrast mechanism (MT-FLASH) was developed for improved imaging of breast lesions that requires neither fat suppression nor postprocessing. After optimization of the sequence in phantom and volunteer studies, a clinical pilot study with 14 patients was performed. In carcinomas the relative signal increase after Gd-DTPA administration was on average 34% in MT-FLASH images compared with 169% in conventional T1-weighted (T1W) three-dimensional FLASH images. In MT-FLASH images, all lesions demonstrated a signal intensity higher than that of fat; in T1W images, all lesions have a lower signal intensity. The average postcontrast carcinoma-to-fat contrast-to-noise ratios were +11.6 and -14.2, respectively. The conspicuity of 12 of 13 carcinomas was improved in postcontrast MT-FLASH imaging enables excellent visualization of Gd-DTPA-enhancing breast lesions.

Adult↗

Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized 3He.

The nuclear spin polarization of noble gases can be enhanced strongly by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization on the order of 0.4-0.6. This is about 10(5) times larger than the polarization of water protons at thermal equilibrium used in conventional MRI. We demonstrate that hyperpolarized 3He gas can be applied to nuclear magnetic resonance imaging of organs with air-filled spaces in humans. In vivo 3He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T. Anatomical details of the upper respiratory tract and of the lungs of a volunteer were visualized with the FLASH technique demonstrating the potential of the method for fast imaging of airways in the human body and for pulmonary ventilation studies.

Adult↗

Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

In this methodological paper the authors report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system that is usable at the MR and the linear accelerator installations. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings (closed rings made of massive metal) led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties-nearly no distortion and high mechanical stability-are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be "corrected" (reducing displacements to the size of a pixel) by calculations based on modeling the distortion as a fourth-order two-dimensional polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms obtained by a maximum-intensity projection algorithm. As a result, information about the hemodynamics of the AVM was provided by a three-dimensional (3D) phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, the origin of the feeding arteries, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. The different imaging techniques of MR provide a sensitive, noninvasive, 3D method for defining target volume, critical structures, and for calculating dose distributions for radiosurgery of cerebral arteriovenous malformations, because dose calculation of radiosurgery at sufficient accuracy can be based on 3D MR data of the geometrical conformation of the patient's head.

Algorithms↗

Safety of intrauterine contraceptive devices during MR imaging.

Three intrauterine contraceptive devices (IUD) were examined in an experimental in vitro setup to test their MR compatibility: Multiload CU375. Nova T (containing copper and silver), and Gyne T. The devices were fixed in a polyacrylamide gel and exposed to the magnetic field and the radiofrequency (RF) of standard MR sequences (spin-echo, turbo-spin-echo, turboFLASH, and magnetization transfer prepared FLASH). The RF power of a turbo-spin-echo sequence was increased by a factor of 5. Temperatures of the IUDs and the gel were measured during the MR examination. No deflection of the IUDs exposed to the magnetic field of 1.5 Tesla was detected. Under normal imaging conditions no temperature increase could be observed. Using an increased RF power, a maximal temperature rise of 0.4 degree C per examination was seen. No differences between the gel and the IUDs were observed, indicating that there is no specific heating of the tested IUDs.

Acrylic Resins↗

[The internet data highway. Are there radiologic applications?].

Today, the world-wide Internet offers a variety of radiological information that can be accessed via modem by every PC user. The available data supplement and extend the information from current sources (books, periodicals, etc.) with continuously updated information for all areas of medical interest. Current radiological applications are already established for training and review purposes. In the future, the Internet will offer extensive databases that can be accessed at any time. Despite the fact that quality-control aspects of the data offered have not been addressed, Internet already provides an enormous gain in information resources.

Computer Communication Networks↗

[Image-oriented planning of minimally invasive conformal irradiation of the head-neck area].

Modern imaging techniques are a substantial part of treatment planning for minimally invasive radiotherapeutic procedures. The aim is three-dimensional assessment of the target volume and adjacent critical structures. In this paper, we report on our clinical experience with a precise system for stereotactic image correlation. Hereby, the advantages of each imaging modality can be combined. Precise immobilization of the patient is a prerequisite. The immobilization method has an accuracy of less than 1 mm. This method was evaluated in a clinical study in which a tumor control rate of 93% was achieved in patients with brain metastases after stereotactic single high dose radiotherapy. This indicated the excellent reliability of this treatment planning method. The integration of functional image information, such as blood flow or activation of cerebral cortical areas, will be evaluated in the future.

Brain↗

Monitoring of task performance during functional magnetic resonance imaging of sensorimotor cortex at 1.5 T.

Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor activation task is-if at all-usually rated visually by subjective or semiquantitative methods (i.e., defining categories of performance such as neurological soft signs scales). Recently, instrumental methods for the measurement and analysis of motor performance have been developed. Pronation/supination (hand rotation) movement was shown to be an easily measurable and promising motor task. We have adapted a mechanic device (pronation/supination device, PSD) to monitor motor performance during the fMRI experiment. In a feasibility study, an investigation of fMRI activation strength dependence of sensorimotor cortices and supplementary motor area upon task frequency (25, 50, and 75 cycles/min) was carried out on 10 right-handed healthy volunteers. Furthermore, the authors report the observation of stimulus-induced activation changes in the cerebellum during pronation/supination movement.

Hand↗

Age dependency of the regional cerebral blood volume (rCBV) measured with dynamic susceptibility contrast MR imaging (DSC).

The changes of the regional cerebral blood volume (rCBV) with age were studied using dynamic susceptibility contrast MRI (DSC). We examined an unselected, random sample of 71 consecutive patients referred for work-up of suspected intracranial tumors (35 normal examinations, 36 tumors) with a standard 1.5 T clinical MR system. Determination of the rCBV was performed with a T2*-weighted simultaneous dual (SD) FLASH sequence (TR/TE1/TE2/alpha = 32/25/16/10 degrees, 55 images) after bolus injection of Gd-DTPA. Absolute quantification of the rCBV was achieved by normalizing the measured tissue concentration-time curves with the integrated arterial input function (AIF), which was simultaneously measured in the brain feeding arteries. The rCBV (mean +/- SD) was 8.4 +/- 2.9 ml/100 g and 4.2 +/- 1.7 ml/100 g in gray and white matter, respectively, with a decline of about 3% and 6% per decade for white and gray matter, respectively. We conclude that DSC using a SD FLASH sequence allows the simultaneous measurement of the AIF and the tissue concentration-time curve and thus an absolute quantification of the rCBV, which is the basis for interperson comparisons and follow-up studies.

Adult↗

A comparison of magnetization prepared 3D gradient-echo (MP-RAGE) sequences for imaging of intracranial lesions.

In a pilot study including 64 patients with different types of brain tumors we investigated four types of MP-RAGE sequences. The sequences differ in the length of the recovery period and the data acquisition mode (sequential vs. centric phase-encoding). The sequence with sequential encoding and a short recovery period provided images that reached the quality and reliability of spin-echo images. The other MP-RAGE sequences failed in providing equivalent information. In particular, a considerable number of small lesions identified in spin-echo images were not detected in MP-RAGE images. The impact of the evolving magnetization on the point spread function was analyzed by performing simulation calculations. It was found that lesions with short T1 times are rendered with low spatial resolution when sequence parameters are not set appropriately. The low overall quality of images obtained by sequences applying centric encoding may be explained by eddy current effects as reported in other recently published studies.

Brain Neoplasms↗

Cerebral arteriovenous malformations: improved nidus demarcation by means of dynamic tagging MR-angiography.

Our purpose was to further improve the target volume definition for radiosurgical treatment of cerebral arteriovenous malformations (AVMs) by means of dynamic MRA (dMRA) using a blood bolus tagging sequence. We therefore compare this technique with 3D-TOF-MRA and transfemoral high resolution angiography in plain film technique. Twenty patients with angiographically proven cerebral AVMs were investigated by dMRA, TOF-MRA, and conventional angiography during the MR-assisted radiosurgical planning protocol. The patient's head was fixed in an MR-compatible stereotactic device. The different angiography techniques were evaluated by consensus of two radiologists. AVMs were characterized by the number and origin of feeding arteries, the maximum diameter of the AVM nidus, and the venous drainage pattern. Dynamic MRA was able to demonstrate the complete AVM characteristics and hemodynamics in 12 out of 20 patients. In three patients with an AVM nidus smaller than 1 cm in diameter the technique could not reliably depict the malformation. Technical problems due to steel screws and pins in the initially used stereotactic frame occurred in five patients. Due to reduced vessel overlap and the lack of disturbances caused by formations with short T1 time, dMRA was superior to TOF-MRA in the detection and the exact localization of the AVM nidus in four patients. We conclude that dMRA is able to demonstrate reliably AVM characteristics and hemodynamics in AVMs with a nidus larger than 1 cm in diameter. Because of the improved demarcation of the AVM nidus, this technique may be a valuable adjunct to radiosurgery planning of cerebral AVMs.

Adult↗

Bone marrow uptake of fluorine-18-fluorodeoxyglucose following treatment with hematopoietic growth factors: initial evaluation.

Hematopoietic growth factors (HGF) such as G-CSF and GM-CSF stimulate cell growth of the bone marrow and thereby mitigate the myelotoxic effect of chemotherapy. Using 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for therapy response monitoring of patients with small-cell lung cancer, both an extension and an intensification of thoracic bone marrow uptake were noted in patients treated with HGF (n = 5) compared to those patients without HGF supplementation (n = 11). FDG uptake was a very sensitive marker of stimulated hematopoiesis, and both the extension and the intensification of uptake have to be noted during HGF therapy.

Adult↗

Macroscopic tumor volume of malignant glioma determined by contrast-enhanced magnetic resonance imaging with and without magnetization transfer contrast.

The purposes of this study were to compare the conspicuity and lesion volume of contrast-enhancing macroscopic malignant glioma determined by postcontrast magnetic resonance (MR) imaging with and without magnetization transfer (MT) saturation, and to discuss possible implications for radiotherapy planning. Nineteen patients (age 24-60 years) with histologically proven malignant glioma were prospectively examined by MR imaging. After the administration of gadolinium dimeglumine (0.1 mmol/kg body weight), the lesions were imaged with an MT-weighted FLASH (fast, low-angle shot) pulse sequence and with a conventional T1-weighted spin-echo (SE) sequence without MT saturation. The mean tumor volumes of gliomas measured on MT-weighted FLASH images were significantly (p < .01) larger than those obtained from T1-weighted SE images (45 +/- 15 cm3 vs. 33 +/- 10 cm3). The mean contrast-to-noise ratio of enhancing lesions on MT-weighted FLASH was 48 +/- 14 compared with 30 +/- 14 on SE images, representing a significant (p < .01) improvement. We conclude that the volume of contrast enhancement of malignant glioma identified on MT-weighted FLASH images represents the area of disrupted blood-brain barrier. If this volume of subtle contrast enhancement is caused by tumor infiltration and represents the boost target volume for stereotactic radiosurgery or brachytherapy, MT-weighted FLASH images would be better than T1-weighted SE images to define these volumes. These improved delineation of areas at highest risk for recurrence following radiation therapy should enhance the efficacy of treatment planning for high-boost therapy.

Adult↗

Functional magnetic resonance imaging in a stereotactic setup.

The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the patients has been immobilized for stereotactic treatment planning either with a self developed stereotactic ceramic frame and bony fixation or with an individual precision mask system made of light cast. It has been shown that this frame does not produce any image distortion. fMRI was performed using a modified FLASH sequence on a conventional 1.5 T MRI scanner with a specially developed linear polarized head coil. The imaging technique used was an optimized conventional 2D and 3D, first order flow rephased, gradient echo sequence (FLASH) with fat-suppression and reduce bandwidth (16-28 Hz/pixel) and TR = 80-120 ms, TE = 60 ms, flip angle = 40 degrees, matrix = 128 x 128, FOV = 150-250 mm, slice-thickness = 2-5 mm, NEX = 1, and a total single scan time for one image of about 7 sec. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. Statistical parametric maps based on student's test were calculated. Pixels with a highly significant signal increase (p < 0.001) are overlaid on T1w SE images. The primary motor and sensory cortex could be visualized with this method in all 10 patients that were imaged in this study. Due to tight fixation of the patient's skull there have been no motion artifacts. These results show that functional MRI is feasible in an stereotactic set-up with an standard 1.5 T scanner. This is a prerequisite for the exact pre therapeutic assessment of the function of cortical centers.

Brain↗

Unusual burns of the lower extremities caused by a closed conducting loop in a patient at MR imaging.

An extremely rare occurrence of third-degree burns was induced in the medial calves of a male patient with unusual anatomy (after resection and radiation therapy of a liposarcoma) during conventional magnetic resonance (MR) imaging on a clinical 1.5-T MR system that operated without any external conductor present and within safe limits. A closed conducting loop was inadvertently created, which caused focal increased temperature at the junction of his calves.

Adult↗

Cervical carcinoma: comparison of standard and pharmacokinetic MR imaging.

PURPOSE: To stage advanced cervical carcinoma with conventional or pharmacokinetic magnetic resonance (MR) imaging by correlating imaging findings with whole-mount specimens and histopathologic findings. MATERIALS AND METHODS: Twenty-six adult patients with primary cervical cancer (stages IIB-IVA) underwent T2-weighted turbo spin-echo (SE) MR imaging; gadolinium-enhanced, T1-weighted SE MR imaging; and gadolinium-enhanced, saturation-recovery, turbo fast low-angle shot MR imaging. All imaging findings were correlated with the whole-mount specimens and histopathologic findings. Signal intensity changes versus time were analyzed by using a pharmacokinetic model and parameter values displayed as a color-coded overlay. RESULTS: Histopathologic stages were IIB (n = 9), IIIB (n = 1), and IVA (n = 16). The overall accuracy for tumor staging was 73% for T2-weighted, 81% for T1-weighted, and 92% for pharmacokinetic MR imaging. Pharmacokinetic MR imaging was accurate (90%) in the diagnosis of tumor extension into the bladder and/or rectal wall but inaccurate (69%) in that of parametrial invasion. T2-weighted images were most accurate (86%) in the assessment of parametrial tumor extension but less accurate (69%) in that of bladder or rectal invasion. CONCLUSION: T2-weighted turbo SE images are still superior to contract medium-enhanced T1-weighted SE or pharmacokinetic MR images in the diagnosis of parametrial infiltration by uterine cervical carcinoma. However, pharmacokinetic MR imaging is a promising method for demonstrating and staging IVA disease.

Adenocarcinoma↗

Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging.

To assess the feasibility of helium-3 magnetic resonance (MR) imaging with a three-dimensional fast low-angle shot (FLASH) sequence, He-3 gas (volume, 300 mL; pressure, 3 x 10(5) Pa; polarized up to 45% by means of optimal pumping) was inhaled by five healthy volunteers and five patients with pulmonary diseases. All breath-hold examinations (22-42 seconds) were completed successfully. Normal ventilation was depicted with homogeneous high signal intensity, lesions were depicted as causing defects, and obstructive lung disease was depicted with severely inhomogeneous signal intensity.

Administration, Inhalation↗