Search PubMed⌕ Search

Biomedical subjects

M V Kameneva

Publications and source records attributed to M V Kameneva.

34 records · Page 2Linked to original sources

Effect of perfluorochemical emulsion on blood trauma and hemorheology.

One of the major problems of development and improvement of heart assist devices is the reduction of blood cell damage. The extremely high levels of shear stress, turbulence, prolonged contact between blood and foreign surfaces, and other abnormal hydrodynamic circumstances have been shown to cause hemolysis, activation of platelets, and changes in mechanical properties of red blood cells. Hemolysis, in turn, can drastically increase red blood cell aggregation at low shear conditions. A new pharmacologic approach to reduce blood trauma and improve rheologic properties of blood subjected to mechanical stress was investigated. These experiments showed that the replacement of 20% of the plasma volume with Fluosol (Alpha Therapeutic Corp., Los Angeles, CA), a perfluorochemical that transports oxygen, reduced mechanical fragility of human (P < 0.01) and ovine (P = 0.054) red blood cells by approximately 30%. The same replacement of plasma with Fluosol reduced hemolysis (plasma free Hb) by approximately 40% compared to control (P < 0.05) during in vitro pumping of blood with a centrifugal pump. A 20% replacement of plasma volume with Fluosol remarkably reduced low shear blood viscosity (from 31.9 +/- 6.1 to 18.2 +/- 4.8 cP, for shear rate gamma = 0.277 sec-1) and erythrocyte sedimentation rate (from 16.7 +/- 9.2 to 3.1 +/- 3.1) mm/hr) in human blood. Decrease of these parameters indicates the reduction of red blood cell aggregation. Results of this study demonstrate the potential feasibility of Fluosol to improve mechanical properties of blood in patients with heart assist devices.

Animals↗

Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system.

Nimbus Inc. (Rancho Cordova, CA) and the University of Pittsburgh have completed the second year of development of a totally implanted axial flow blood pump under the National Institutes of Health Innovative Ventricular Assist System Program. The focus this year has been on completing pump hydraulic development and addressing the development of the other key system components. Having demonstrated satisfactory pump hydraulic and biocompatibility performance, pump development has focused on design features that improve pump manufacturability. A controller featuring full redundancy has been designed and is in the breadboard test phase. Initial printed circuit layout of this circuit has shown it to be appropriately sized at 5 x 6 cm to be compatible with implantation. A completely implantable system requires the use of a transcutaneous energy transformer system (TETS) and a diagnostic telemetry system. The TETS power circuitry has been redesigned incorporating an improved, more reliable operating topography. A telemetry circuit is undergoing characterization testing. Closed loop speed control algorithms are being tested in vitro and in vivo with good success. Eleven in vivo tests were conducted with durations from 1 to 195 days. Endurance pumps have passed the 6 month interval with minimal bearing wear. All aspects of the program continue to function under formal quality assurance.

Heart-Assist Devices↗

Chronic animal health assessment during axial ventricular assistance: importance of hemorheologic parameters.

Chronic testing of the Nimbus/UOP Axial Flow Pump was performed on 22 calves for periods of implantation ranging from 27 to 226 days (average, 74 days). The following parameters were measured: plasma free hemoglobin, blood and plasma viscosity, erythrocyte deformability and mechanical fragility, oxygen delivery index (ODI), blood cell counts, hematocrit, hemoglobin, blood urea nitrogen, creatinine, bilirubin, total protein, fibrinogen, and plasma osmolality. Most of the above parameters were stable during the full course of support. Compared with baseline, statistically significant differences during the entire period of implantation were only found in: hematocrit (p<0.001), hemoglobin (p<0.005), red blood cell (RBC) count (p<0.001), and whole blood viscosity (p<0.01). Plasma viscosity and ODI were mostly stable during the period of implantation. In some animals, an acute increase in fibrinogen concentration, plasma and blood viscosity, and a decrease in ODI were found to be early signs of the onset of infection. A small (10%) decrease in deformability of RBCs was found during the first 2 weeks after implantation. This alteration in RBC deformability was highly correlated (r = 0.793) with changes in total plasma protein concentration that fell more than 15% (p<0.001) during the same period. Mechanical fragility of RBCs was found to be slightly increased after implantation. Plasma free hemoglobin remained close to baseline level (p>0.2). After the first 2 weeks of the postoperative period, pump performing parameters for all animals were consistent and stable. In general, the Nimbus/UOP Axial Flow Pump demonstrated basic reliability and biocompatibility and did not produce significant alterations in the mechanical properties of blood or animal health status. The pump provided adequate hemodynamics and was well tolerated by the experimental animal for periods as long as 7.5 months. Monitoring rheologic parameters of blood is very helpful for evaluation of health during heart-assist device application.

Animals↗

Decrease in red blood cell deformability caused by hypothermia, hemodilution, and mechanical stress: factors related to cardiopulmonary bypass.

During extracorporeal circulation in cardiopulmonary bypass (CPB) surgery, blood is exposed to anomalous mechanical and environmental factors, such as high shear stress, turbulence, decreased oncotic pressure caused by dilution of plasma, and moderate and especially deep hypothermia widely applied during CPB in infants. These factors cause damage to the red blood cells (RBCs), which is manifest by immediate and delayed hemolysis and by changes in the mechanical properties of RBCs. These changes include, in particular, decrease in RBC deformability impeding the passage of RBCs through the microvessels and may contribute to the complications associated with CPB surgery. We investigated in vitro the independent and combined effects of hypothermia, plasma dilution, and mechanical stress on deformability of bovine RBCs. Our studies showed each of these factors to cause a significant decrease in the deformability of RBCs, especially acting synergistically. The impairment of RBC deformability caused by hypothermia was found to be more pronounced for RBCs suspended in phosphate buffered saline (PBS) than for RBCs suspended in plasma. The decrease in RBC deformability caused by mechanical stress was significantly exacerbated by dilution of plasma with PBS. In summary, results of our in vitro study strongly point to a possible detrimental consequence of conventional CPB arising from increased RBC rigidity, which may lead to impaired microcirculation and tissue oxygen supply.

Animals↗

Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension.

The purpose of this study was to evaluate the real time relationship between pump flow and pump differential pressure (D-P) during experimentally induced hypertension (HT). Two calves (80 and 68 kg) were implanted with the EVA-HEART centrifugal blood pump (SunMedical Technology Research Corp., Nagano, Japan) under general anesthesia. Blood pressure (BP) in diastole was increased to 100 mm Hg by norepinephrine to simulate HT. Pump flow, D-P, ECG, and BP were measured at pump speeds of 1,800, 2,100, and 2,300 rpm. All data were separated into systole and diastole, and pump flow during HT was compared with normotensive (NT) conditions at respective pump speeds. Diastolic BP was increased to 99.3+/-4.1 mm Hg from 66.5+/-4.4 mm Hg (p<0.01). D-P in systole was under 40 mm Hg (range of change was 10 to 40 mm Hg) even during HT. During NT, the average systolic pump flow volume was 60% of the total pump flow. However, during HT, the average systolic pump flow was 100% of total pump flow volume, although the pump flow volume in systole during HT decreased (33.1+/-5.7 vs. 25.9+/-4.0 ml/systole, p<0.01). In diastole, the average flow volume through the pump was 19.6+/-6.9 ml/diastole during NT and -2.2+/-11.1 ml/diastole during HT (p<0.01). The change in pump flow volume due to HT, in diastole, was greater than the change in pump flow in systole at each pump speed (p<0.001). This study suggests that the decrease of mean pump flow during HT is mainly due to the decrease of the diastolic pump flow and, to a much lesser degree, systolic pump flow.

Animals↗

Heparin effect on red blood cell aggregation.

We studied the effect of relatively high dosages of heparin (25-150 U/ml) on some rheological parameters of donor blood. It was found that heparin increased the erythrocyte sedimentation rate (ESR) and low shear blood viscosity at all concentrations studied. The increase of these parameters indicates an elevation in RBC aggregation. In all samples with a heparin concentration of 100 U/ml, the average ESR was increased by approximately 75% (p < 0.001); whole blood viscosity increased under shear rate, gamma = 0.277 sec-1, by approximately 30% (p < 0.001). Since bolus injection of heparin may result in transient high local concentration, these results suggest a possible additional adverse effect to the well known heparin effect on platelet aggregation.

Anticoagulants↗

A sheep model for the study of hemorheology with assisted circulation. Effect of an axial flow blood pump.

Hemorheologic investigations were performed on nine sheep during the in vivo evaluation of a new axial flow ventricular assist device, the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, CA). Blood hematocrit, plasma and whole blood viscosity, red blood cell (RBC) deformability and aggregation, plasma fibrinogen, and free hemoglobin (hemolysis) levels were measured. Changes in the main rheologic parameters of sheep blood relative to the pre-implant values were minor and transient. The exception was RBC aggregation, which appeared on the third day of implantation. (Sheep blood does not normally demonstrate RBC aggregation.) Sheep RBCs started to form classic rouleaux typically on the third post-operative day simultaneously with increasing fibrinogen level. To investigate the relative effects of mechanical stress and elevated fibrinogen levels on RBC aggregability, in vitro studies were conducted with blood from control sheep. These studies indicated that neither mechanical trauma nor elevated fibrinogen alone caused RBC aggregation as seen in vivo. However, combined mechanical stress and elevated fibrinogen did cause this unusual effect for sheep blood.

Animals↗

In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods.

Continuing in vivo trials are being conducted at the University of Pittsburgh using the Nimbus axial flow blood pump (AxiPump). To date, 14 sheep experiments have been performed to address several issues related to short-term support. Six acute experiments (< 6 hr) have been performed to assess hemodynamics related to speed regulation and to determine anatomic placement of the pump and cannulae. Eight short-term survival studies lasting up to 6 days have been performed to evaluate biocompatibility and system reliability, and to establish clinical management protocols. The AxiPump has been used as a left ventricular assist device (LVAD), right ventricular assist device (RVAD), and biventricular assist device (BiVAD) with left ventricular and right atrial cannulation. The AxiPump has demonstrated the ability to assume complete support of either the pulmonary or systemic circulation, or both. We have determined that sufficient surgical access may be obtained through left lateral thoracotomy for both LVAD and RVAD insertion. In the absence of post operative anticoagulation therapy, we have detected subclinical renal cortical infarctions in 6 of 8 short-term animals. Thrombus deposition has been observed at the ventricular cannula tip in 4 of 8 cases--necessitating design changes. Two short-term experiments have been terminated because of bleeding--one due to inflow cannula obstruction and one due to cannula failure. Plasma free hemoglobin levels were all below 15 mg/dl, except for one case complicated by inflow obstruction.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Mechanisms of red blood cell trauma in assisted circulation. Rheologic similarities of red blood cell transformations due to natural aging and mechanical stress.

Clinical experience with circulatory support devices has typically shown alteration of patient blood rheology exhibited through increasing blood viscosity and decreasing erythrocyte deformability. Our hemorheologic studies have additionally shown a remarkable increase in red blood cell (RBC) aggregation in the blood of artificial heart patients as compared to healthy donors. These hemorheologic changes may be caused by mechanical trauma to RBCs. The authors hypothesize that the mechanical trauma process, from a rheologic point of view, could be analogous to an "accelerated" RBC aging process. The hypothesis was examined through in vivo and in vitro experiments on RBCs, age-separated on the basis of density, specifically to identify the rheologic similarities between aged and mechanically traumatized RBCs. Older RBCs demonstrated an increased mechanical fragility, a decreased deformability, and a increased ability to aggregate as compared to younger RBCs. RBCs exposed to mechanical stress demonstrated similar alterations in the same rheologic parameters. Our experiments have also shown that mechanical stress decreases the negative surface charge of RBCs as is known to occur in aged RBCs. Similarities found between the processes of RBC mechanical trauma and senescence enhance our understanding of mechanisms of subhemolytic trauma incurred in assisted circulation. This may improve the design and evaluation of future heart assist devices through minimizing shear induced blood trauma.

Animals↗

Continued development of the Nimbus/University of Pittsburgh (UOP) axial flow left ventricular assist system.

Nimbus and the University of Pittsburgh (UOP) have continued the development of a totally implanted axial flow blood pump under the National Institutes of Health (NIH) Innovative Ventricular Assist System (IVAS) program. This 62 cc device has an overall length of 84 mm and an outer diameter of 34.5 mm. The inner diameter of the blood pump is 12 mm. It is being designed to be a totally implanted permanent device. A key achievement during the past year was the completion of the Model 2 pump design. Ten of these pumps have been fabricated and are being used to conduct in vitro and in vivo experiments to evaluate the performance of different materials and hydraulic components. Efforts for optimizing the closed loop speed control have continued using mathematical modeling, computer simulations, and in vitro and in vivo testing. New hydraulic blade designs have been tested using computational fluid dynamics (CFD) and flow visualization. A second generation motor was designed with improved efficiency. To support the new motor, a new motor controller fabricated as a surface mount PC board has been completed. The program is now operating under a formal QA system.

Animals↗

Plasma protective effect on red blood cells exposed to mechanical stress.

Hemodilution with plasma expanders is a widely applied practice during extracorporeal circulation and hemodialysis. Despite the immediate beneficial effects of hemodilution, such as reduction of blood viscosity and red blood cell (RBC) aggregation, elevation of blood flow in the microcirculation, etc., the dilution of plasma may cause some unfavorable effects on RBCs, amplifying the mechanical damage caused by circulatory assist devices. The authors investigated the effect of partial and total replacement of plasma on susceptibility of human and bovine RBCs to mechanical stress in vitro. Hemolysis was measured after the exposure of RBCs suspended in different media to similar mechanical stress. Experiments were performed at room temperature with control of osmolality and viscosity of the suspension media. The lowest hemolysis was obtained for RBCs suspended in serum, plasma, and albumin solutions. Hemolysis in PBS and Dextran suspensions was more than three times higher than that in plasma (p < 0.001). The protective effect depended upon protein concentration. Human RBCs were found to be significantly more sensitive to mechanical stress than bovine RBCs in all investigated suspension media (p < 0.005). Human RBCs from men suspended in plasma were found to be significantly (p < 0.05) more fragile than RBCs from women. The presence of even small amounts of plasma (such as 25%) in the suspension media significantly (p < 0.001) decreased hemolysis. However, a 30% replacement of plasma with PBS or Dextran solutions caused a statistically significant (p < 0.001) increase in mechanical hemolysis. This suggests that a decrease in the concentration of plasma proteins due to hemodilution may elevate blood damage during extracorporeal circulation and hemodialysis.

Animals↗