Search PubMed⌕ Search

Biomedical subjects

M V Kamath

Publications and source records attributed to M V Kamath.

At least 37 records · Page 2Linked to original sources

Cerebral evoked responses to gastrointestinal stimulation in humans.

Recent advances have permitted recording of evoked potentials (EPs) in response to electrical and mechanical stimulation of the gastrointestinal (GI) organs via methods used primarily in clinical neurophysiology. Current research involving stimulation of the esophagus, rectum, and colon, and recording the corresponding responses on the scalp, is being practiced in only a few laboratories. This review examines the engineering aspects of recording EPs, such as characteristics of the stimuli, placement of stimulus electrodes in the GI tract, and enhancement of evoked potential signals. We also discuss the physiological concepts involved in the generation of EPs, and how these compare with somatosensory evoked responses. Current experimental techniques employed by various investigators and results reported from their laboratories are compared. We believe that cerebral EPs to GI stimulation could be useful in studying a number of pathophysiological conditions such as gastroesophageal reflux disease, diffuse esophageal spasm, chronic inflammatory bowel disorders, chronic abdominal pain, and irritable bowel syndrome, among others. We hope that the present review will generate interest in the use of EPs arising out of GI stimulation, aiding in understanding their physiological implications in healthy subjects and in GI disorders.

Cerebral Cortex↗

Regional distribution and kinetics of [18F]6-flurodopamine as a measure of cardiac sympathetic activity in humans.

OBJECTIVES: To determine whether an increase in cardiac sympathetic activity produced by exercise or sublingual glyceryl trinitrate causes an increased rate of loss of fluorine-18 from the myocardium after intravenous [18F]6-fluorodopamine ([18F]F-DA) in normal volunteers. In addition, to determine the contribution of non-specific uptake of [18F]F-DA in the myocardium in patients with recent heart transplant. PROTOCOL: [18F]F was prepared by direct electrophilic fluorination of dopamine. Nine healthy volunteers each received 1.85 x 10(8) Bq (168-250 micrograms) [18F]F-DA over a period of 3 min and were scanned for 2 h in an ECAT 953/31 tomograph. Three controls were scanned before and after vigorous cycle exercise and two were scanned before and after sublingual glyceryl trinitrate. In addition, two patients (1 and 2 years post-heart transplant) underwent a myocardial perfusion study with ammonia labelled with nitrogen-13 followed by an [18F]F-DA study. RESULTS: There was intense uniform uptake of [18F]F-DA throughout the myocardium in the healthy volunteers. The time course of 18F in the myocardium under resting conditions fitted a biexponential function with mean half-times of 8.0 and 109 min. Vigorous exercise produced a three to fivefold increase in the rate of loss of 18F compared with that when resting. After glyceryl trinitrate, one control had a profound reduction in blood pressure (23%) and twofold increase in the rate of loss of myocardial 18F. The other control had no physiologically significant change in blood pressure, heart rate, or rate of loss of myocardial 18F. Uptake of [18F]F-DA in the two posttransplant patients was confined to a small anterobasal region adjacent to the atrioventricular groove, while blood flow, as measured with [13N] ammonia, was uniformly distributed throughout the myocardium. Partial reinnervation of the myocardium was confirmed by the presence of distinct low frequency spectral peaks of the heart rate power spectrum in both patients. CONCLUSIONS: These results suggest that the uptake of [18F]F-DA reflects the distribution of cardiac sympathetic innervation and that the rate of loss of 18F from the myocardium partially reflects spill over of noradrenaline. The technique may be useful in investigating various cardiac conditions in which the sympathetic system is compromised.

Adult↗

Double blind placebo controlled trial of short term transdermal scopolamine on heart rate variability in patients with chronic heart failure.

OBJECTIVE: To test the hypothesis that short term application of transdermal scopolamine increases heart rate variability (HRV) and restores sympathovagal balance in patients with stable congestive heart failure (CHF). DESIGN: A double blind placebo controlled crossover study. SETTING: Tertiary referral centre. PATIENTS: Twelve patients (mean age 66 (10)) with New York Heart Association class II-IV CHF. All patients had coronary artery disease (mean left ventricular ejection fraction 26.7 (8.9) %). INTERVENTION: Patients were randomly assigned to receive either a placebo skin patch or a transdermal scopolamine patch (Transderm, 0.05 mg/h). Patches remained in place for 48 hours with a 24 hour washout period before crossover. OUTCOME MEASURES: HRV was derived from (a) 24 hour time domain indices (mean RR interval, standard deviation of interbeat interval, and the baseline width of the frequency distribution of RR intervals) and (b) short data set (2.2 mm) power spectral measurements using autoregressive modelling. Autospectral measures were performed in both resting supine and standing (orthostatic) states. The 24 hour Holter record was obtained during the second day of patch application. RESULTS: There was a small but significant (P < 0.05) increase in all time domain HRV variables with scopolamine. There was a paradoxical fall in low frequency (LF) spectral power induced by orthostasis during baseline (-30%) and placebo (-34%) states. Conversely, scopolamine was associated with a 14% increase in LF power during orthostatic stress. Scopolamine thus significantly reduced the orthostatic fall in LF (P < 0.01) compared with either baseline or placebo values. No difference in circadian rhythm was seen between the scopolamine and placebo treatment periods. However, the abrupt fall in the high frequency (vagal) power during the early morning sleep-wake hours was reduced by scopolamine. Scopolamine was also associated with a significant rightward shift in the resting LF central frequency consistent with a vagomimetic effect. CONCLUSION: Patients with chronic stable CHF showed a paradoxical fall in the low frequency (sympathetic) power during orthostatic stress. Transdermal scopolamine applied over a 48 hour period partially restored the balance between sympathetic tone and vagal activity in CHF patients and maintained this balance during orthostatic stress.

Administration, Cutaneous↗

Variable clinical expression of mosaic trisomy 16 in the newborn infant.

Trisomy 16 is common in embryos and fetuses aborted early during development. Mosaicism for trisomy 16 is sometimes encountered during prenatal diagnosis, particularly with chorionic villi biopsy specimens, and, until recently, was thought to be confined to the placenta. However, recently, several liveborn infants with trisomy 16 mosaicism have been described. We report on an additional liveborn infant with trisomy 16 mosaicism and compare the clinical findings with those of the previously reported cases in an attempt to delineate a mosaic trisomy 16 syndrome. Cytogenetic analysis from our patient showed that there was a different proportion of abnormal cells in different tissues and that the anomaly was undetectable in blood lymphocyte cultures. This observation was consistent with some of the previous reports. DNA analysis of parents and child was carried out using a polymorphic dinucleotide marker that maps to the long arm of chromosome 16. This analysis showed that the extra chromosome 16 in the infant was maternal in origin and suggested that the nondisjunction was probably a first meiotic division error. Our results suggest that an investigation of multiple tissues is required before concluding that mosaicism is confined to the placenta. We conclude that a finding of trisomy 16 mosaicism at prenatal diagnosis should be regarded with extreme caution. This diagnosis may be associated with a highly variable phenotype that may occasionally be compatible with extrauterine life.

Abnormalities, Multiple↗

Operation Everest II: an indication of deterministic chaos in human heart rate variability at simulated extreme altitude.

It has been shown that fluctuation of human heartbeat intervals (heart rate variability, HRV) reflects variations in autonomic nervous system activity. We studied HRV at simulated altitudes of over 6000 m from Holter electrocardiograms recorded during the Operation Everest II study (Houston et al. 1987). Stationary, approximately 30-min segments of HRV data from six subjects at sea level and over 6000 m were supplied to (1) spectral analysis to evaluate sympathetic and parasympathetic nervous system (SNS, PNS) activity, (2) the analysis of Poincaré section of the phase space trajectory reconstructed on a delayed coordinate system to evaluate whether there was fluctuation with deterministic dynamics, (3) the estimation of the correlation dimension to evaluate a static property of putative attractors, and (4) the analysis of nonlinear predictability of HRV time series which could reflect a dynamic property of the attractor. Unlike HRV at sea level, the recordings at over 6000 m showed a strong periodicity (period of about 20 s) with small cycle-to-cycle perturbation. When this perturbation was expressed on a Poincaré section, it seemed to be likely that the perturbation itself obeyed a deterministic law. The correlation dimensions of these recordings showed low dimensional values (3.5 +/- 0.4, mean +/- SD), whereas those of the isospectral surrogates showed significantly (P < 0.05) higher values (5.3 +/- 0.5) with embedding dimensions of 5.6 +/- 0.9.(ABSTRACT TRUNCATED AT 250 WORDS)

Altitude↗

Distortion-product and click-evoked otoacoustic emissions of preterm and full-term infants.

Full-term and preterm infants were evaluated with click-evoked and distortion-product otoacoustic emissions (CEOEs and DPOEs). The CEOEs and DPOEs recorded from each individual ear were analyzed by calculating the root-mean-square levels within half-octave bands. The fail criterion of the OE tests was that the half-octave RMS DPOE or CEOE levels of an ear under test were below the 10th percentile of full-term newborns in two or more bands. The DPOE data were collected from 118 ears of 61 premature babies; 80 (68%) ears passed the DPOE test, 30 (25%) ears without middle ear effusions failed the test, and 8 (7%) ears with effusions also failed. The CEOE data were collected from 128 ears of 65 premature babies; 102 (80%) ears passed the CEOE test, 18 (14%) ears without middle ear effusions failed the test, and 8 (6%) ears with effusions also failed. In 23 of 80 ears (29%) that passed the DPOE test and in 23 of 102 ears (23%) that passed the CEOE test, RMS OE levels of preterm infants were above the 90th percentile of full-term newborns. The analyses of the combined DPOE and CEOE data obtained from a group of 25 ears of full-term newborns and from a group of 72 ears of preterm babies showed statistically significant correlations between the DPOE and CEOE root-mean-square levels in each of the half-octave bands in the 1.4 to 4 kHz region. For 42 preterm infants tested with auditory brain stem response (ABR), specificity was 86% for CEOE and 74% for DPOE. All infants who failed the ABR also failed OE tests. To the best of our knowledge, this study is the first using combined DPOEs, CEOEs, and ABRs for preterm babies. It showed the feasibility of DPOEs and CEOEs for this population.

Acoustic Impedance Tests↗

Power spectral analysis of heart rate variability: a noninvasive signature of cardiac autonomic function.

Power spectral analysis of short segments of beat-to-beat heart rate variability (PS/HRV) reveals three distinct peaks. In human PS/HRV, the high frequency (HF) band (0.15 to 0.4 Hz) is correlated with respiratory driven vagal efferent input to the sinus node. The low frequency band (LF) 0.06 to 0.15 Hz is believed to be due to baroreceptor mediated blood pressure control. Therefore, PS/HRV represents a noninvasive signature of the balance between sympathetic and parasympathetic components of the autonomic nervous system. This paper reviews the literature on the methodological issues relevant to signal processing, computational, and clinical applications of PS/HRV. Factors affecting the power in the LF and HF bands are examined in healthy controls. Recent work from several laboratories suggests that PS/HRV is a potentially powerful tool for exploring neurocardiac dysfunction in patients with a variety of cardiac and autonomic disorders. Mathematical models which simulate neurocardiac control are examined. Concerns regarding the lack of standardization between different laboratories are expressed. As the PS/HRV attains the status of a clinical diagnostic test, we hope that this review serves as a source of integrated information for researchers in this field.

Adult↗

Neural regulation of heart rate variability in endurance athletes and sedentary controls.

OBJECTIVE: The aim was to examine the cardiac autonomic responses to orthostatic stress and recovery from steady state exercise in endurance trained athletes and sedentary subjects. METHODS: The power spectrum of heart rate variability was measured before and after exercise in 10 male long distance runners and 14 male sedentary control subjects. Both groups were comparable in sex, age, and body mass index. Continuous ECG recordings were obtained during the following physiological manoeuvres: 45 min supine rest state; 10 min standing; 15 min steady state exercise at 50% maximum workload, and 15 min while supine during post-exercise recovery. The resting heart rate of athletes was lower than controls, at 52(SD 4.9) v 67(8.7) beats.min-1, p < 0.001. Power spectrum analysis was performed using autoregressive modelling. RESULTS: The resting high frequency (HF) vagal component was higher in athletes than controls, at 62 (10.7) v 44(22.4) beats.min-1.Hz-1, p < 0.05. The resting low frequency (LF) peak power was significantly reduced in athletes, at 54(9.9) v 70(19.5) in control, p < 0.05. Although no group differences were observed during upright posture or exercise, the LF:HF area ratio had already returned to pre-exercise levels within 5 min of recovery in athletes. Conversely, it required up to 15 min of recovery before a noticeable decrease in the LF:HF area ratio was seen in controls. CONCLUSIONS: These data support the hypothesis that endurance training modifies heart rate control in whole or in part through neurocardiac mechanisms.

Adult↗

Neurocardiac responses to vagoafferent electrostimulation in humans.

UNLABELLED: To determine if cardiac vagal tone is enhanced by vagal electrostimulation (VES), we examined the heart rate autospectrum (HRA) in eight patients with implanted stimulators for complex partial seizures. In four patients the VES was activated at 30 Hz and 500-msec pulse (HiStim group) compared to 2 Hz and 130-msec pulse for the LoStim group (n = 4). Continuous ECG and respiratory waveforms were recorded for 45 minutes every 8 hours (7-8 AM; 3-4 PM 11-12 PM) during resting supine wakeful epochs both before and 15 days after surgical implantation. From the HRA cardiac sympathovagal balance was expressed as the ratio of the low frequency (LF) power to the high frequency (HF) power. RESULTS: There were no presurgical differences between the groups in heart rate, its variance, or the energies contained in any autospectral band. The LoStim group showed no significant change in heart rate (HR), HF peak power, or LF:HF ratios during 2 weeks of VES. Conversely, in the HiStim group, the LF:HF peak power ratio (an expression of sympathetic dominance) decreased from 2.5 +/- 1.5 preimplant to 1.5 +/- 0.49 (P < 0.02) with VES. During VES there was a significantly higher HF power in the HiStim compared to LoStim group. No diurnal variations in HRA values were seen for either group. CONCLUSIONS: (1) A relationship exists between selective vagal nerve electrostimulation and the HRA; and (2) high stimulation frequency of the vagus nerve in man is associated with sustained augmentation of cardiac vagal tone throughout a 24-hour cycle.

Adult↗

Effect of vagal nerve electrostimulation on the power spectrum of heart rate variability in man.

The power spectrum of heart rate variability contains low frequency (LF = 0.08-0.12 Hz) and high frequency (HF = 0.18-0.30 Hz) components said to represent neurocardiac rhythms. To verify whether such a relationship exists we report a unique study where the heart rate autospectrum was determined in a 28-year-old epileptic male patient with an implanted vagal electrical stimulator. The stimulator was activated at 20 Hz, 300 microseconds pulse, and 1.25 V. Continuous ECG and respiratory waveform records were obtained over 45 minutes every 8 hours (7-8 AM; 3-4 PM; 11-12 PM) with the stimulator ON, then 24 hours OFF and then 24 hours ON again. The overall LF:HF peak ratio increased from 0.64 to 1.99 (P less than 0.001) after the stimulator was turned OFF. There was a dramatic increase in the LF peak power (greater than 60%) and a corresponding decrease in the HF peak power (greater than 65%) when the stimulator was turned OFF. These values were reversed when the stimulator was turned ON again. In the early morning and late evening hours, there was a significant rightward shift in the LF peak power frequency (average 0.057 to 0.075 Hz) whenever the stimulator was ON. Otherwise, there were no significant circadian variations in any of the autospectral components. The results demonstrate an unequivocal relationship between selective vagal nerve electrostimulation and alterations in the heart rate autospectrum.

Adult↗

A randomized placebo-controlled double-blind study of danazol in hemophilia A.

A randomized double-blind placebo-controlled crossover trial of danazol was carried out in 19 cases of hemophilia A. Danazol was given for 3 months at a dose of 150 mg/day to patients under 15 years of age, and 300 mg/day to older patients. The basal factor VIII:C level was 8.3 +/- 5.6% (mean +/- SD), and after 3 months of danazol treatment was 15.3 +/- 11.0% (p = 0.02). Six patients (basal factor VIII:C 2-22%) showed a 1.36- to 2.87-fold elevation of factor VIII:C levels after danazol. 0/2, 1/4 and 5/13 cases of severe, moderate and mild disease, respectively, responded. Decreases in the number of bleeding episodes and cryoprecipitate requirement were seen in the responders. No adverse reactions to danazol were encountered. Danazol appears to raise the factor VIII:C levels in selected cases of hemophilia A.

Adolescent↗

Diurnal variations of neurocardiac rhythms in acute myocardial infarction.

To determine the diurnal pattern of cardiac autonomic tone in acute myocardial infarction (AMI), this study examined the power spectrum of heart rate (HR) variability in 24 patients during a single 24-hour segment within 4 days of AMI. Patients were nonrandomly allocated to a group (n = 14) without autonomic drugs and to a group (n = 10) already receiving beta blockers at the time of AMI. With use of autoregressive modeling, the power spectrum of HR variability was computed from continuous 1-hour electrocardiographic segments recorded at equally spaced intervals; 7 to 8 A.M., 3 to 4 P.M., and 11 to 12 P.M. All patients were supine, awake and pain free during recordings. There were no differences in HR, HR variance or the low-frequency peak power (0.06 to 0.1 Hz) from one temporal sequence to another. For the patients not taking beta blockers, the high-frequency peak power (0.2 to 0.36 Hz) or vagal component increased significantly from 3 P.M. to 11 P.M. (28 +/- 11 to 45 +/- 20 beats/min2.Hz-1, p less than 0.01). There was a significant decrease in the low- to high-frequency peak power and area ratios from 3 P.M. to 11 P.M. All power spectral parameters in the patients taking beta blockers remained unchanged over 24 hours. There was significantly heightened vagal modulation of sinus node activity in those receiving beta blockers, especially at 7 A.M. and 3 P.M. The data suggest that under steady-state wakeful conditions in the early recovery phase after an AMI, vagal tone is more pronounced during the late evening hours with a possible shift to relative sympathetic dominance during early morning and midafternoon hours.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists↗

Effects of steady state exercise on the power spectrum of heart rate variability.

The effects of steady state exercise on the power spectrum of heart rate variability were studied in 19 healthy subjects. Continuous ECG signals were recorded during 1) 15 min of rest in the supine state, 2) 10 min of standing, 3) 10 min of steady state exercise at 50% of maximum predicted power output on a cycle ergometer, and 4) 15 min of post-exercise recovery in the supine state. Autoregressive modeling was used to determine the power spectrum of heart rate variability. While orthostatic stress produced a significant 51% increase in the ratio of low to high frequency peak spectral power, steady state exercise caused a significant suppression of both low and high frequency components. The low frequency peak power rose to significantly high levels throughout 15 min of the post-exercise recovery period. There was a significant leftward shift in the frequency of the low frequency peak with exercise and a rightward shift during the recovery supine state. These results suggest that neuroregulatory control of heart rate plays a major role in adaptive responses to orthostatic stress and post-exercise recovery, while humoral factors are probably more important in maintaining heart rate during steady state exercise.

Adult↗

Large pericardial effusion after cardiac surgery: role of echocardiography in diagnosis and management.

We performed M-mode and two-dimensional (2-D) echocardiograms prospectively in 140 patients an average of eight days after open heart surgery. Large pericardial effusions occurred in 13 patients; three had complete circumcardiac pericardial effusion, four had local anterior adhesions, five had extensive anterior adhesions (posterior loculated effusion), and one had a large loculated pericardial effusion contiguous to the right atrium. In five patients with tamponade, the effusion was drained, with immediate reversal of symptoms and signs of tamponade. In the other eight patients, who had no deterioration in cardiovascular status, the effusion was not drained; instead, these patients were treated medically with indomethacin and observed with serial echocardiograms, and the effusions eventually disappeared. The most consistent echocardiographic differences between the five patients with and the eight patients without tamponade were that patients with tamponade had larger posterior pericardial effusions, more severe left atrial compression, and more indentation of the right atrial wall. Echocardiography plays an essential role in diagnosis and management of large pericardial effusions after open heart surgery. Patients with large pericardial effusions who are clinically stable need only medical management, including serial echocardiograms, but drainage is indicated if the cardiovascular or respiratory status worsens. Certain echocardiographic findings indicate a high probability of tamponade.

Adult↗

Monitoring spinal cord blood flow using hydrogen polarography.

Spinal cord blood flow (SCBF) is an important physiological variable that may undergo changes following cord injury. We measured SCBF in healthy dogs whose cord had been cooled, a technique that is useful for treating spinal cord injured patients. A microcomputerized system developed for efficient recording of SCBF on-line is described in this paper.

Animals↗

Microcomputerized on-line evaluation of heart rate variability power spectra in humans.

The heart rate variability power spectra is computed using an on-line microcomputer system. In normal subjects (n = 10), standing and post-exercise states demonstrated statistically significant increases (p less than 0.05) in the peak power at 0.1 Hz. During exercise, the peak power at 0.1 Hz was reduced significantly (p less than 0.05). In patients with myocardial infarction, either the peak at 0.1 Hz or the peak associated with breathing frequency was augmented. Our system is mobile and is useful especially when on-line heart rate variability power spectra are required in experimental or clinical situations.

Adult↗

Statistical pattern classification of clinical brainstem auditory evoked potentials.

The brainstem auditory evoked potentials (BAEPs) recorded in the neurological clinic were classified using the Bayes classifier (BC) and Fisher's linear discriminant function (FLD). The latencies of initial five peaks, interpeak intervals were examined for optimum features to develop classifiers. The accuracy of classification was 85.3% when absolute latencies of peaks III, IV and V were used as features. The BC gave better performance than FLD, indicating that second order statistics of BAEPs for normal and pathological classes are different. The results of this study indicate that latencies alone give enough information for recognizing normal from pathological BAEPs, using physician's evaluation of BAEPs as the reference.

Adult↗