Search PubMedSearch

Biomedical subjects

M Urie

Publications and source records attributed to M Urie.

At least 19 recordsLinked to original sources

A pencil beam algorithm for proton dose calculations.

The sharp lateral penumbra and the rapid fall-off of dose at the end of range of a proton beam are among the major advantages of proton radiation therapy. These beam characteristics depend on the position and characteristics of upstream beam-modifying devices such as apertures and compensating boluses. The extent of separation, if any, between these beam-modifying devices and the patient is particularly critical in this respect. We have developed a pencil beam algorithm for proton dose calculations which takes accurate account of the effects of materials upstream of the patient and of the air gap between them and the patient. The model includes a new approach to picking the locations of the pencil beams so as to more accurately model the penumbra and to more effectively account for the multiple-scattering effects of the media around the point of interest. We also present a faster broad-beam version of the algorithm which gives a reasonably accurate penumbra. Predictions of the algorithm and results from experiments performed in a large-field proton beam are presented. In general the algorithm agrees well with the measurements.

Algorithms

Potential improvement of three dimension treatment planning and proton beams in fractionated radiotherapy of large cerebral arteriovenous malformations.

The treatment of large cerebral arteriovenous malformations is a surgical challenge, especially for deep seated brain locations. Furthermore, these lesions are unfit for radiosurgical approaches due to a high risk of complications secondary to high radiation doses to large brain volumes. Fractionated precision radiotherapy can potentially deliver high, uniform, target-contoured dose distributions optimizing the dose reduction to the critical surrounding brain. The results of a study are presented in such a way that dose distributions achievable with proton beams are compared to those with 10 MV x-rays; and the potential improvements with protons evaluated, relying heavily on dose-volume histograms to examine the coverage of the lesion as well as the dose to the normal brain, brain-stem, and optic chiasm.

Humans

Proton beams in radiation therapy.

The rationale for study of proton radiation therapy is that, for some anatomic sites and tumors, the treatment volume is smaller; i.e., there is less irradiation of nontarget tissue while the target is included in three dimensions at each treatment session. As a result, the dose to the target can be raised. The consequence is that the tumor control probability improves and the frequency and severity of treatment-related morbidity decrease. These results come about from the physical fact that the proton range in tissue is finite; in comparison, absorption of photons is an exponential function and, hence, some dose is received for the full-beam path through the body. Accordingly, the dose deep to the target for proton treatments can be zero for each beam path. This situation provides a virtually certain means of improving the treatment outcome for selected categories of patients. Experience to date with proton radiation therapy has been quite limited. As of June 1991, the total number of proton radiation-treated patients was 11,763 from the various centers. Of that number, approximately 46% and 32% have been treated for small benign intracranial lesions (principally pituitary adenomas and arteriovenous malformations) and for tumors of the eye, respectively. Thus, only some 2500 patients have been treated for all other tumor types. The results from three centers and approximately 2800 patients with uveal melanoma are that the local control rate was 96% (for failures in-field, marginal, and in other parts of the eye). The local control results for chondrosarcomas and chordomas of the skull base are 91% and 65%, respectively. These percentages compare with some 35% achieved with conventional treatment. Experience with arteriovenous malformations indicates that control of bleeding and disappearance of the lesion are comparable to those achieved by other procedures. The developments from the proton therapy programs have contributed greatly to radiation treatment planning, e.g., the first three-dimensional treatment planning system put into regular clinical use (uveal melanoma), beam's eye view, digital-reconstructed radiograph, dose-volume histograms, and definitions of the uncertainty in dose around any defined point. The potential for clinical gains is high. In May 1991, the Proton Radiation Oncology Group was formed to design, supervise, and coordinate clinical trials and to assist in data analysis. The efficacy of proton radiation therapy will be compared with that of photon therapy of the very highest technology.

Arteriovenous Malformations

Optimization of 3D radiation therapy with both physical and biological end points and constraints.

A new optimization model is described and its clinical usefulness is demonstrated. The optimization technique was developed to allow computer optimization of 3-dimensional radiation therapy plans with biological models of tumor and normal tissue response to radiation as well as with scores based on physical dose. The emphasis was placed on the optimization model, which should describe, as closely as possible, the goal of the radiation treatment, which is eradication of the tumor while sparing normal tissues. Since the statement of the goals may vary from case to case, a technique that allows a variety of objective functions and types of constraints was developed. The optimization algorithm is capable of handling nonlinear and even discrete score (objective) functions and constraints and effectively explores the vast space of feasible solutions in a relatively short time (minutes of MicroVax 3200 CPU time). An example of computer optimization of radiation therapy of a chordoma of the sphenoid bone using x-ray and proton beams is shown and compared with the best plans achieved by an experienced planner. Directions for future development of the algorithm, allowing optimization of beam orientation, are presented.

Chordoma

Dose-volume histograms.

A plot of a cumulative dose-volume frequency distribution, commonly known as a dose-volume histogram (DVH), graphically summarizes the simulated radiation distribution within a volume of interest of a patient which would result from a proposed radiation treatment plan. DVHs show promise as tools for comparing rival treatment plans for a specific patient by clearly presenting the uniformity of dose in the target volume and any hot spots in adjacent normal organs or tissues. However, because of the loss of positional information in the volume(s) under consideration, it should not be the sole criterion for plan evaluation. DVHs can also be used as input data to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). The sensitivity of TCP and NTCP calculations to small changes in the DVH shape points to the need for an accurate method for computing DVHs. We present a discussion of the methodology for generating and plotting the DVHs, some caveats, limitations on their use and the general experience of four hospitals using DVHs.

Humans

Considerations in fractionated proton radiation therapy: clinical potential and results.

Protons have a finite range in tissue and can provide a better concentration of radiation dose in the tumor than conventional X-rays in certain situations. The development of optimized treatment plans for X-rays and protons followed by a comparative evaluation is one method of selecting tumor sites best suited for proton treatment. The preliminary results of comparative treatment planning for base of skull tumors and carcinoma of the prostate are discussed. These comparisons suggest a clinical gain for proton treatment of tumors in these locations. The clinical experience with fractionated proton treatment of several tumor sites is also discussed. The results of high dose proton treatment of chordomas and low grade chondrosarcomas of the base of skull is particularly promising: an actuarial 5-year local control of 78% has been obtained in 50 patients followed for a minimum of 22 months.

Carcinoma

Large scale optimization of beam weights under dose-volume restrictions.

The problem of choosing weights for beams in a multifield plan which maximizes tumor dose under conditions that recognize the volume dependence of organ tolerance to radiation is considered, and its solution described. Structures are modelled as collections of discrete points, and the weighting problem described as a combinatorial linear program (LP). The combinatorial LP is solved as a mixed 0/1 integer program with appropriate restrictions on normal tissue dose. The method is illustrated through the assignment of weights to a set of 10 beams incident on a pelvic target. Dose-volume restrictions are placed on surrounding bowel, bladder, and rectum, and a limit placed on tumor dose inhomogeneity. Different tolerance restrictions are examined, so that the sensitivity of the target dose to changes in the normal tissue constraints may be explored. It is shown that the distributions obtained satisfy the posed constraints. The technique permits formal solution of the optimization problem, in a time short enough to meet the needs of treatment planners.

Humans

Fractionated proton radiation therapy of cranial and intracranial tumors.

Since 1973 fractionated proton radiation therapy has been used in the treatment of malignant disease. Protons have favorable physical characteristics that yield dose distributions superior to those of photons in certain clinical situations. As of December 31, 1987, 1,678 patients had been treated. Of these, 110 had chordomas or low-grade chondrosarcomas of the base of skull. The first 68 patients have a minimum follow-up of 17 months. The median dose was 69 Cobalt Gray Equivalent (CGE). (CGE is the dose in proton Gray multiplied by 1.1, which is the relative biological effectiveness for protons relative to 60Cobalt.) The actuarial 5-year local control rate is 82%, and the disease-free survival rate is 76%. Thirteen patients with meningiomas have been treated, following subtotal resection. The median dose was 59.4 CGE. With a median follow-up of 26 months, no patient has had tumor progression. In addition, nine patients with gliomas and 12 with craniopharyngiomas have been treated.

Adolescent

Increased efficacy of radiation therapy by use of proton beam.

Proton beam treatment techniques provide a powerful approach to improving dose distribution (decrease treatment volume towards target volume) and hence increasing dose to target with resultant higher tumor control rates and lesser morbity. To achieve these dose distributions in patients requires use of modern imaging techniques, rigid immobilization systems, confirmation of target position vis a vis the proton beam at each treatment session, treatment planning which feature beam's eye view, displays of uncertainty, dose at each anatomic point, boli based on accurate assessment of density along each pixel, etc. Experience at MGH/MEEI/HCL has yielded a disease-free survival of 78% for patients with chordoma/chondrosarcoma of base of skull. Local control is achieved by 98% of patients treated for choroidal melanoma.

Chondrosarcoma

Conservative treatment of uveal melanoma: local recurrence after proton beam therapy.

Twenty-three of 1006 (2.3%) uveal melanoma patients treated with proton beam therapy at the Harvard Cyclotron Laboratory between July 1975 and December 31, 1986 received additional treatment for documented (15 patients) or suspected (eight patients) tumor growth in the irradiated eye. Growth within the initially irradiated volume was documented at Massachusetts Eye and Ear Infirmary in 12 patients. Documented growth occurred in nine of 665 (1.4%) patients with small and intermediate size tumors, at times after treatment ranging from 6 to 48 months (median 16 months), and in three of 341 (.9%) patients with large tumors at 7, 11, and 12 months after treatment. Melanoma growing totally outside the treated volume was also documented in three additional patients at 7, 9, and 45 months; two of these were thought to be "ring melanomas". Eight patients had the treated eye removed elsewhere for suspected tumor growth. The additional treatment in these 23 patients was conservative in nine patients (repeat proton irradiation in five and laser photocoagulation in four). Thirteen underwent immediate enucleation and one had orbital exenteration. Ultimately, 17 of the 23 eyes (74%) were removed. Estimated probability of local control of the melanoma within the irradiated eye at 60 months was 96.3 +/- 1.5%. Dose distributions to the 12 patients with documented local failure within the irradiated volume were analyzed. Ten tumors recurred marginally in an area receiving less than the prescribed dose of 70 CGE (CGE = Cobalt Gray Equivalents = proton Gy X RBE 1.1), whereas only two recurred in the volume receiving full dose. Based on these data, it appears that a dose of 70 CGE in five fractions is associated with very high rates of local control in human uveal melanoma. It is reasonable to consider initiating studies using a lower total dose or a more protracted course, to determine if some of the observed complications are dose-related.

Adult

Neurovisual outcome following proton radiation therapy.

From February 1981 to January 1984, 20 patients with a tumor of the upper clivus received proton irradiation at the Harvard Cyclotron Laboratory. For 15 patients with known neurovisual status (including visual acuity, color vision, visual field, and fundus examinations) we obtained a cumulative dose-volume histogram (DVH) of the optic nerves (ON) and the optic chiasm. The prescribed tumor doses ranged from 66.6 to 74.4 Cobalt Gray Equivalent (CGE) with a daily fraction size of 1.8 to 2.1 CGE. CGE is used because modulated protons have an RBE of 1.1 compared to 60Co. The follow-up ranged from 30 to 68 months (median 52). Two patients developed, 10 and 36 months post irradiation, a progressive visual deterioration affecting both eyes. This was attributed to an ON and a chiasm injury in one patient and to bilateral ON injury in the other patient. In the first patient, the dose-volume analysis indicated that approximately half of the ON and of the chiasm had received 65 CGE and 55 CGE, respectively. In the second patient, it indicated that a quarter of the left ON (LON) had received 55 CGE whereas the dose to the right ON (RON) was significantly less. This patient had diabetes mellitus which may be a predisposing factor. From this study, a complication rate of 20% (1/5) is observed when a substantial portion of the ON is taken to 65 CGE, while it doesn't exceed 12.5% (2/16) and 7.5% (1/13) at 55 CGE for the ON and for the chiasm, respectively. This suggests a tolerance dose implying a 10% rate of major complications close to 55 CGE. When a tumor requires a high radiation-dose, the exclusion of these structures at 55 to 60 Gy is recommended.

Adult

The risk of enucleation after proton beam irradiation of uveal melanoma.

Enucleation after proton beam irradiation of uveal melanomas occurred in 64 (6.4%) of 994 eyes with a median follow-up time of 2.7 years. The median time between irradiation and enucleation in the 64 enucleated eyes was 13 months. The probability of retaining the eye was 95 and 90%, 2 and 5 years postirradiation, respectively. Three percent of eyes were enucleated during posttreatment year 1, and the yearly rate was 1% by the fourth year. No patient had enucleation later than 5 1/2 years posttreatment. The complication most likely to result in enucleation was neovascular glaucoma although this was frequently managed without enucleation. Other common reasons for enucleation were documented or suspected tumor growth and complete retinal detachment with associated loss of vision. The leading risk factors for enucleation were anterior tumor margin involving the ciliary body, tumor height greater than 8 mm, and proximity of the tumor to the fovea. Based on the presence or absence of these factors, 5-year eye retention rates were 99, 92, and 76% for low-, moderate-, and high-risk groups, respectively. Thus, the probability of eye retention after proton beam irradiation is high even among those at greatest risk of enucleation.

Eye Enucleation

Fractionated proton radiation therapy of chordoma and low-grade chondrosarcoma of the base of the skull.

Sixty-eight patients with chordoma or low-grade chondrosarcoma at the base of the skull received fractionated high-dose postoperative radiation delivered with a 160-MeV proton beam. Protons have favorable physical characteristics which allow the delivery of high doses of radiation to these critically located tumors. The methods employed for these treatments are described. These patients have been followed for at least 17 months and for a median of 34 months. The median tumor dose was 69 CGE (cobalt Gy equivalent): CGE is the dose in proton Gy multiplied by 1.1, which is the relative biological effectiveness for protons compared to cobalt-60. The daily dose was 1.8 to 2.1 CGE. For this group the 5-year actuarial local control rate is 82% and disease-free survival rate is 76%. The incidence of treatment-related morbidity has been acceptable.

Adolescent

Endocrine function following high dose proton therapy for tumors of the upper clivus.

The endocrine status of patients receiving proton radiation for tumors of the upper clivus was reviewed to evaluate the effect of high dose treatment on the pituitary gland. The fourteen patients had chordomas or low grade chondrosarcomas and were all treated by the same techniques. The median tumor dose was 69.7 Cobalt Gray Equivalent (CGE) with a range from 66.6 to 74.4 CGE. (CGE is used because modulated protons have an RBE of 1.1 compared to 60Co). The daily fraction size was 1.8-2.1 CGE. The median follow-up time is 48 months, ranging from 30 to 68 months. All treatments were planned using a computerized multi-dimensional system with the position of the pituitary outlined on the planning CT scan. Review of the dose distribution indicated that the dose to the pituitary ranged from 60.5 to 72.3 CGE, with a median of 67.6 CGE. One female patient had decreased thyroid and gonadotropin function at the time of diagnosis and has been on hormone replacement since that time. The other three females were all pre-menopausal at the time of radiotherapy. At this time four patients (3 males and 1 female) have developed endocrine abnormalities 14 to 45 months after irradiation. All four had evidence of hypothyroidism and two have also developed corticotropin deficiency. The three males had decreased testosterone levels; the female patient developed amenorrhea and hyperprolactinemia. All four are asymptomatic with ongoing hormone replacement.

Adolescent

Metastasis from uveal melanoma after proton beam irradiation.

The incidence of metastasis and prognostic factors for metastasis in 780 consecutive patients with uveal melanomas treated with proton beam irradiation were evaluated. Metastasis developed in 64 patients (8%). The median time from treatment to the diagnosis of metastasis was 2.1 years (range, 3 months to 7.3 years). The liver was primarily involved in 58 (90%) patients. The 5-year cumulative probability of metastasis developing was 20%. Prognostic factors for metastasis developing were quite comparable to those found for patients treated by enucleation and included largest tumor diameter, involvement of the ciliary body, older age, and extrascleral extension. Surgical localization, tumor height, and elevated liver enzymes before treatment were not important factors in the development of metastasis.

Adolescent

Uveal melanomas near the optic disc or fovea. Visual results after proton beam irradiation.

Proximity to the disc and fovea is a risk factor for visual loss after proton beam irradiation of uveal melanomas. Of 562 eyes treated over a 10-year period with pretreatment visual acuity of 20/200 or better, 363 (64.6%) contained tumors within 2 disc diameters (DD) of the disc or fovea. Rates of visual loss after treatment to worse than 20/200 and causes of visual decline were evaluated using Kaplan-Meier analysis. Cumulative rates of visual loss among subjects with tumors near the disc or fovea were 33 and 47% 1 and 2 years after treatment compared to 17 and 28%, respectively, for subjects with tumors located farther from both structures. The leading cause of visual loss in the first year among eyes with tumors near the disc or fovea was retinal detachment. Controlling for other predictors of visual loss to worse than 20/200, location near the disc or fovea was independently related to visual loss primarily due to retinal detachment, cataract, and radiation retinopathy. Despite the unfavorable location of these tumors, over half of patients with 20/200 or better pretreatment visual acuity had useful vision 2 years after treatment.

Cataract

Long-term results of proton beam irradiated uveal melanomas.

The first 128 consecutive patients with uveal melanomas treated with proton beam irradiation were studied in order to evaluate survival and visual acuity status of patients with relatively long-term follow-up. The median follow-up was 5.4 years, and no patient was lost to follow-up. All tumors showed regression. The most recent visual acuity was 20/40 or better in 35% and 20/100 or better in 58%. Eight eyes were enucleated because of complications. Metastasis developed in 26 patients (20.5%) from 3 months to 7 years after treatment. Results indicate that proton irradiation is quite successful for achieving local control of uveal melanomas. A large proportion of the treated eyes maintained useful vision. Five-year follow-up data indicate that proton irradiation has no deleterious effect on the likelihood of the development of metastasis.

Eye Diseases

Prognostic factors for metastasis following proton beam irradiation of uveal melanomas.

Prognostic indicators for the development of metastasis following proton beam irradiation of uveal melanomas were evaluated for 510 patients treated from 1975 to 1984. Thirty-three patients developed metastasis (6.5%) from 3 to 51 months following treatment. The primary site of metastasis was the liver in 28 cases (85%). Both demographic and clinical factors were considered. The three leading predictors of survival without metastasis after proton beam irradiation in order of importance were: (1) largest diameter of the tumor; (2) location of the anterior margin of the tumor; and (3) age at treatment. Worse prognosis was associated with largest tumor diameter greater than 15.0 mm, tumor involvement of the ciliary body and age at treatment older than 59 years.

Adult