Search PubMed⌕ Search

Biomedical subjects

M Traisnel

Publications and source records attributed to M Traisnel.

At least 19 recordsLinked to original sources

Vascular prostheses with controlled release of antibiotics Part 2. In vitro biological evaluation of vascular prostheses treated by cyclodextrins.

Viability tests by the colony forming method show no toxicity for all CDs (beta-CD, gamma-CD, HPbeta-CD and HPgamma-CD) and their associated polymer. A survival rate of 100% is observed for all CDs at high concentration 400 ppm. Proliferation tests revealed a low proliferation of L132 cells on grafted vascular prostheses and untreated prostheses and good proliferation on Melinex (film form of PET). A proliferation of 17% is observed after 3 days of incubation and decrease at 4% after 6 days on prostheses. Melinex exhibits a proliferation rate as the controls. Vitality tests confirm proliferation tests and show a good vitality of cells even for low cell amounts. From these experiments it becomes obvious that the decreasing proliferation rate is not a cytotoxic effect but is due to the chemical and/or physical surface characteristics. A similar result is obtained for cell adhesion kinetics between grafted vascular prostheses and control. After 2 h adhesion, a lower adhesion is observed on untreated prostheses. Theses results were confirmed by immunochemistry and morphology tests. This cell adhesion inhibiting effect of the PET prostheses contributes to a better "survival" of vascular prostheses without secondary obstruction or stenosis.

Anti-Bacterial Agents↗

Vascular prostheses with controlled release of antibiotics Part 1: Surface modification with cyclodextrins of PET prostheses.

Vascular prostheses were functionalised with the aim to obtain a slow release of antibiotics in order to reduce postoperative infections. The original process that we present in this paper is based on the use of a family of cage molecules named cyclodextrins (CD). These compounds have the ability to form reversible inclusion complexes with drugs such as antibiotics. The aim of this work was to graft CD onto the prosthesis, so that an antibiotic can be bound on it by this inclusion phenomenon, and then be progressively released over a prolonged period by a complex dissociation mechanism. This paper presents the first part of this research program and concerns mainly the study of the functionalization parameters. It presents surface characterization results of the modified prostheses. The PET prostheses were immersed into a solution containing a cross linking agent, cyclodextrins (beta-CD, gamma-CD, HP-beta-CD and HP-gamma-CD) and a catalyst and were padded. Grafting occurred by the mean of a thermofixation step at a temperature comprised between 140 and 180 degrees C. It was observed that the support was permanently modified when the CD polymer that coated the fibres resisted to the final washing process. Grafting rates of 12 wt% in CD polymer could be reached. It was also observed that the fibre coating reaction induced an increase of the permeability of the grafts.

Anti-Bacterial Agents↗

Physico-chemical and biological evaluation of excimer laser irradiated polyethylene terephthalate (pet) surfaces.

The aim of this work was to investigate the consequences of excimer laser irradiation on the physico-chemical and biological properties of polyethylene terephthalate (PET) films, currently used for medical devices. Three PET films from different origins were studied in the present work, chosen with respect to their chemical and physical properties, which are of high importance for ulterior medical application as vascular prostheses. Multiple assays were carried out to characterize the physical and chemical effects of the laser irradiation: surface morphology tests (light microscopy, Dektak profilometer and confocal laser scanning microscopy) showed the strong transformation of the surface with the laser treatment. Contact angle measurements revealed a significant increase of the surface energy for each PET depending on the applied fluency. Finally XPS characterization of the surface demonstrated the appearance of new chemical species favorable for cell attachment. This aspect had to be strongly considered regarding to the multiple biological effects of laser irradiated surfaces on living cells. Different cell culture experiments were carried out with L132 human epithelial cells after 6-days culture: proliferation and vitality rate, cell adhesion and cell morphology. Results clearly revealed that laser treatment improved cell proliferation (up to 140% with respect to controls), vitality (10% higher than controls), morphology and adhesion kinetics (more than 16% of control). A significant correlation (R2=0.906) was also established on one PET between the fluencies of laser treatment and the cellular response. These results emphasized high importance of the choice of the PET material for a medical application: only one of the three considered PET films showed really improved cellular response.

Biocompatible Materials↗

Vascular PET prostheses surface modification with cyclodextrin coating: development of a new drug delivery system.

PURPOSE: Cyclodextrins (CDs) are torus shaped cyclic oligosaccharides with a hydrophobic internal cavity and a hydrophilic external surface. We performed and analysed an antibiotic binding on Dacron (polyethyleneterephtalate, PET) vascular grafts, previously coated with CDs based polymers. METHODS: The CDs coating process was based on the pad-dry-cure method patented in our laboratory. The Dacron prostheses were immersed into a solution containing a polycarboxylic acid, a cyclodextrin and a catalyst, and placed into a thermofixation oven before impregnation with an antibiotic solution (Vancomycin). Biocompatibility tests were performed with L132 human epithelial cells. The antibiotic release in an aqueous medium was assessed by batch type experiments using UV spectroscopy. RESULTS: Viability tests confirmed that the CDs polymers coating the Dacron fibers were not toxic towards L132 cell. Cell proliferation was similar on coated and uncoated grafts. A linear release of Vancomycin was observed over 50 days. CONCLUSION: Our results demonstrate the feasibility of coating CDs onto vascular Dacron grafts. Biological tests show no toxicity of the different cyclodextrins coated. A linear release of antibiotics was depicted over 50 days, demonstrating that cyclodextrin grafting was an efficient drug delivery system.

Anti-Bacterial Agents↗

Surface analyses of micro-arc oxidized and hydrothermally treated titanium and effect on osteoblast behavior.

Osteoblast adhesion on the implant material surface is essential for the success of any implant in which osteointegration is required. Surface properties of implant material have a critical role in the cell adhesion progress. Titanium and its alloys are widespread and increasingly used as implant material in dentistry and orthopedics because of their excellent biocompatibility, which is attributed to a passive layer of TiO2 on the surface. In this study, the micro-arc oxidizing (MAO) and hydrothermally synthesizing (HS) methods were used to modify the TiO2 layer on the titanium surface. The surface microstructure was observed by scanning electron microscopy. The surface energy was assessed. The mouse osteoblastic cell line (MC3T3-E1) was seeded on the treated surfaces to evaluate their effect on cell behavior. This included cell adhesion kinetics, cell proliferation, cell morphology, and cytoskeletal organization. The surface structure of MAO samples exhibited micropores with a diameter of 1-3 microm, whereas the MAO-HS-treated samples showed additional multiple crystalline microparticles on the microporous surface. The surface energy of MAO and MAO-HS was higher than that of titanium. The cell adhesion rate was higher on the MAO-HS surface than on the MAO and titanium surface, but without any significant difference between them. After 3 days of culture, cells proliferated significantly more on the MAO and titanium surface than on the MAO-HS surface. The cytoskeletal organization was analyzed by actin and vinculin staining on all the samples. We conclude that the MAO and MAO-HS methods change the surface energy of TiO2 layer on the titanium surface. This may have an influence on the initial cell attachment. Other surface characteristics may be involved in the cell proliferation, which is different from cell attachment on the sample surface. A longer-duration cell experiment should be conducted to see the effect on cell differentiation. Future in vivo evaluation may give further evidence to optimize the surface character of this kind of implant material.

Actins↗

Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use.

Orthodontic arcs and wires are mostly realised from alloys and constitute the motor of dental shifting. Ti-base alloys rapidly replaced the formerly used stainless steel wires due to their excellent corrosion resistance, their high mechanical characteristics and their increased biocompatibility. NiTiNOL shape memory alloys add to these advantages their ability of deforming force. NiTiNOL, highly pure Nickel (hp-Ni) and commercially pure titanium (cp-Ti) were tested by electrochemical assays in artificial saliva and in vitro biological tests with L132 cells and HEPM cells. All tests gave concordant results: the electrochemical assays, the proliferation test, the colony forming method, and the inflammatory test clearly show, that nickel is a corrosive and a cytotoxic material. Ti and NiTiNOL are cytocompatible and in particular corrosion resistant. No significant differences are observed for both materials on the electrochemical and the biological level as well. The NiTiNOL shape memory alloy is a master trump for dental practitioners to repair occlusal defects by shifting teeth under optimal biological conditions. In spite of its high Ni-content, it is biocompatible. It considerably reduces the tune of therapeutic treatment, facilitate the occlusal concept and leads to a result of high clinical quality.

Alloys↗

[The electrochemical behavior of TiTa30 and TiNb30 alloys for implantology].

The electrochemical behavior in artificial saliva of TiNb30 and TiTa30 alloys were compared with that of commercial pure titanium. The anodic potential, the current density, the passivation potential and the galvanic corrosion vs. Au were determined. Both alloys have a similar behavior to that of pure titanium. Crevace corrosion, which is very weak in pure Ti, is completely inhibited by the addition of Nb or Ta.

Alloys↗

[Pharmaceutical technology: development and research].

Production of pharmaceutics cannot be compared to the manufacture of consumer goods: pharmaceutical manufacturing is the study and bulk manufacture of the ingredients from which medicines are made, and is concerned with the mixing, preparing, packing, of the ingredients into a dosage form for the patient, in according to the good manufacturing practices (GMP). Development and manufacture are not discrete activities but links in a single chain of activity. Research and development, pharmaceutical training, regulatory requirements: these concepts are present with three ways: bioavailability, targeting and compliance.

Dosage Forms↗

[HPLC used in the validation of simple methods for research of degradation products in essential drug tablets].

HPLC have been used to validate simple methods to be employed in developing countries (DC) for the quality control of drugs. As the important lack of analytical material in DC, colorimetric methods have been used. These are subjected to visual appreciation of the color intensity. Two essential drugs have been selected: aspirin, hydrochlorothiazide. For each compound, standardization of concentration's degradation product by colorimetry and HPLC have been achieved in proximity of the restricted norms of pharmacopoeia. These results have been applied to tablets exposed to stressed conditions (t(0) = 60 and humidity = 75%). The results obtained by colorimetric method were similar to HPLC's ones.

Aspirin↗

Corrosion of surgical implants.

Corrosion on orthopaedic implants has been studied. Twelve intramedullary nails and twelve osteosynthesis plates were implanted up to eight and thirteen years, respectively. Analysis of biological fluids from all patients was carried out and revealed high concentrations of nickel and chromium that correlated to the implantation time. All implants were corroded by both crevice and intergranular corrosion. Intergranular corrosion is related to mechanical and heating treatments. Crevice-like corrosion is probably enhanced by sulphur present in amino-acids. Electronic probe analysis shows the reaction study between both sulphur and nickel and sulphur and chromium. These results are compared to the metal distribution in body fluids. After a certain incubation time the corrosion accelerates as is characteristic for crevice-like corrosion processes. Studies of the distribution rate of two Ni-Fe-Cr dental alloys in a cell culture system give similar results: metal-ion release increases with the exposure time.

Bone Nails↗

[Non-destructive quality control of tablets by photoacoustic infrared spectrometry. Analysis in primary packaging].

We have studied the feasibility of the photoacoustic detection in Fourier transform infrared spectrometry for the quality control of drug tablets. Beyond the non destructive character of the method, the main advantage which has been established is the precocity of impurity detection on the tablet outside. The direct recording of spectra through PVC lead to interesting results for study of tablets under blister.

Drug Packaging↗