Search PubMed⌕ Search

Biomedical subjects

M Tondeur

Publications and source records attributed to M Tondeur.

At least 37 records · Page 2Linked to original sources

Reproducibility of technetium-99m mercaptoacetyltriglycine clearance.

The aim of this paper was to determine the reproducibility (precision) of technetium-99m mercaptoacetyltriglycine (MAG3) clearance and to compare it with that of chromium-51 ethylenediamine tetra-acetic acid (EDTA). Twelve young volunteers (aged between 21 and 34 years), without any history of medical problems, were enrolled in this study. The test was performed twice, at an interval of 8 days and under similar physiological conditions. After the intravenous injection of both tracers, 15 blood samples were taken between 3 and 240 min. A biexponential fit was adapted to the plasma disappearance curves (5- to 120-min samples for 99mTc-MAG3 and 10- to 240-min samples for 51Cr-EDTA); the clearances were calculated according to Sapirstein and corrected for body surface area. The mean clearance values were 110 (range 85-130) and 226 (range 109-319)ml/min/1.73 m2, respectively, for 51Cr-EDTA and 99mTc-MAG3. For 51Cr-EDTA clearance, the mean difference between the first and the second measurement was -2.1% of the mean of the two successive values (SD: 8.4%). In ten cases, the difference was less than 12%; in two cases, the differences were 15% and 18%, respectively. For 99mTc-MAG3 clearance, the mean difference between the first and the second measurement was -20% of the mean of the two successive values (SD: 25%). In six cases, the difference was less than 12%; in four cases, between 15% and 40%; and in two cases, more than 60%. Methodological factors (impurities contained in the commercial kit, variable protein binding) as well as physiological factors (pH of urine, sodium load, stress) may explain the lack of precision of the 99mTc-MAG3 clearance. It is concluded that changes in 99mTc-MAG3 plasma clearance should be interpreted with care in daily routine.

Adult↗

The robustness of the Patlak-Rutland slope for the determination of split renal function.

The aim of this study was to evaluate the variability of the Patlak-Rutland slope as applied to the renal clearance method. We analysed the 99Tcm-mercaptoacetyltriglycine renograms of 17 non-selected patients (both children and adults, number of kidneys = 34) with a single kidney glomerular filtration rate of 6-73 ml min-1 1.73 m-2. the acquisition time for the renograms was 20 min with a frame duration of 20 s. First, correction for background activity was introduced using the perirenal area and the size ratio between the kidney and the perirenal area. The Patlak plot was then applied. The first two points were systematically rejected and a series of linear fits calculated from the experimental points, starting from the third point (i.e. 1 min). The final point of the fit never exceeded the time of the peak of the renogram minus one minute (Tmax - 1) and was always less than 5 min. Although simple visual inspection of the slopes would suggest that the experimental points were distributed accurately along a straight line, it appeared that the slope was strongly dependent on the number of points used for the determination of the fit. As a second step, we restricted the number of points for fitting to the time interval between 1 min and 2 min 40 s. This procedure appeared to show that the Patlak methodology is reliable, giving rise to only small variations in slope, depending on the number of points chosen. However, even in this narrow time interval, significant errors can be made, either because of the very early escape of the radionuclide or because of statistical noise (e.g. in renal failure the signal-to-noise ratio is unfavourable). Therefore, it is advisable, when using this methodology, to restrict the fitting procedure to the second minute of the study and to check visually that this fixed time interval gives rise to a slope that is well adapted to the Patlak plot.

Adult↗

Reproducibility of simplified techniques for the measurement of 51Cr-EDTA clearance.

The aim of this study was to assess the reproducibility of a number of simplified clearance methods using chromium-51 ethylenediamine tetraacetic acid (51Cr-EDTA) and to compare these with the multiple blood sample technique. Twenty-four healthy volunteers were enrolled into the study. The test was performed twice, 1 week apart and under similar physiological conditions. After intravenous injection of the tracer, 13 blood samples were taken between 5 and 240 min. The reference clearance was calculated after adapting a bi-exponential fit on the whole plasma disappearance curve. Simplified methods included the slope intercept method using different combinations of blood samples (2 and 4 h; 2, 3 and 4 h; 1.5, 2, 3 and 4 h; 1.5, 2 and 3 h) and several single clearance methods (Constable 3 h; Groth 3 h; Groth 4 h). The standard deviation of the differences between the first and second measurements were similar for all methods, confirming the comparable reproducibility of these methods.

Chromium Radioisotopes↗

Overall accuracy of technetium-99m-MAG3 clearance measurements obtained with a gamma camera heart curve.

UNLABELLED: The aim of the present study was to evaluate the accuracy of 99mTc-MAG3 clearance measurements using a precordial gamma camera curve calibrated by a single plasma sample. METHODS: Technetium-99m-MAG3 was administered to ten young normal volunteers. A 60-min gamma camera acquisition was performed. Five different segments of the gamma camera curve were determined: 3 min to 20 min, 3 min to 30 min, 3 min to 40 min, 3 min to 50 min and 3 min to 60 min. A biexponential function was fitted on each of these five different segments, which were thereafter calibrated using eight different blood samples. These blood samples were successively used for calibration at 5, 10, 15, 20, 30, 40, 50 and 60 min. The single injection, multiple plasma sample method was used as reference. RESULTS: Camera clearances varied markedly based on the length of the precordial curve and on the time of the calibration sample. Different regression equations were obtained for each duration of the camera curve, and for each blood sample timing. Correlation coefficients were > 0.95 in most cases recording period of at least 50 min, however, was necessary to obtain a s.e.e. better than those obtained using a single blood sample method without gamma camera curve. CONCLUSION: The 99mTc-MAG3 clearance determination using a gamma camera heart curve calibrated with a single blood sample does not necessarily improve the accuracy of the one blood sample method.

Adult↗

Electroencephalographic mapping and 99mTc HMPAO single-photon emission computed tomography in carbon monoxide poisoning.

STUDY OBJECTIVE: To investigate whether topographic analysis of EEG mapping and technetium-99m (99mTc) hexamethylpropylenamine oxide (HMPAO) brain single-photon emission computed tomography (SPECT) can detect cerebral anomalies in the acute phase of carbon monoxide poisoning. DESIGN: Twelve patients aged 18 to 55 years with severe carbon monoxide poisoning and no history of neurologic disorder were evaluated. Either nasal (5 patients) or hyperbaric (7 patients) oxygen therapy was administered. Criteria for hyperbaric oxygen therapy were blood CO of more than 20%, loss of consciousness, pregnancy, or signs of cardiac injury. After oxygen treatment, all patients had a blood CO value of 0% and no patient had persistent acute signs of toxicity. Patients then were investigated by confentional EEG, EEG mapping, and 99mTc HMPAO brain SPECT. These procedures were performed on the day of admission. PARTICIPANTS: After nasal (5 patients) or hyperbaric (7 patients) oxygen therapy was administered, 12 adults with severe carbon monoxide poisoning were evaluated. All studies were performed on the day of admission. MEASUREMENTS: Conventional EEG, EEG mapping, and 99mTc HMPAO brain SPECT. RESULTS: While classic EEG was normal in 9 of 12 patients and showed diffuse anomalies in 3, EEG mapping and 99mTc HMPAO brain SPECT demonstrated unilateral or bilateral regional anomalies in 8 of 12 patients. Anomalies were localized in temporo-parieto-occipital areas, the watershed areas of the major cerebral arteries, or in temporal cortex. CONCLUSION: These preliminary results suggest that EEG mapping and 99mTc HMPAO brain SPECT can be complementary tools to diagnose early regional cerebral anomalies in carbon monoxide-poisoned patients.

Acute Disease↗

Bilateral cerebral mediofrontal hypoactivity in Tc-99m HMPAO SPECT imaging.

Fifteen patients who had bilateral mediofrontal hypoactivity and 30 control subjects without this SPECT anomaly underwent Tc-99m HMPAO brain SPECT imaging. Bilateral mediofrontal hypoactivity was found in various neurologic disorders, including subcortical arteriosclerotic encephalopathy, lacunar state, chronic alcoholism, progressive nonvascular dementia, carbon monoxide poisoning, and diabetes mellitus. This SPECT abnormality was, however, specifically associated with three clinical signs: motor disabilities predominating in the lower limbs, urinary incontinence, and akinetic mutism.

Akinetic Mutism↗

360 degrees or 180 degrees for bone SPECT of the spine?

Acquisitions of 360 degrees are usually performed for bone single photon emission computed tomography (SPECT). However, the spine is a peripheral and median structure, it therefore seemed interesting to compare the 360 degrees and the posterior 180 degrees SPECT images. In a phantom study and in 25 adult patients, the 360 degrees SPECT images were compared with the posterior 180 degrees images obtained during the same acquisition: the posterior 180 degrees images are at least equivalent to the 360 degrees images. With a reduction in the examination time, SPECT could become easier to perform, especially in patients suffering from back pain.

Adult↗

Prediction of cerebral palsy in high-risk neonates: a technetium-99m-HMPAO SPECT study.

In infants who have experienced prenatal or perinatal injury, it is often difficult, on the basis of clinical examination and conventional investigations (electroencephalogram, cranial ultrasound scan), to diagnose those with brain damage and to predict the type and the severity of subsequent neurological handicaps. We investigated the predictive value of 99mTc-HMPAO brain SPECT performed in the first weeks of life in high-risk neonates. Right-left asymmetries in tracer uptake had no predictive value, regardless of their localization or severity. On the other hand, a change in antero-posterior rCBF distribution was found in 7/10 of neonates with adverse outcome (death, major neurological sequelae) and in none of the 78 neonates with no major motor neurological sequelae. Compared to conventional investigations, 99mTc-HMPAO brain SPECT did not provide additional predictive information when neurological examination, electroencephalogram and cranial ultrasonography were all normal or all abnormal. Conversely, in the 30 patients with anomalies on one or two of the above investigations, SPECT showed an abnormal antero-posterior pattern in 4/6 neonates with major neurological sequelae and no change in the antero-posterior rCBF distribution in the 24 infants who developed normally. In conclusion, our results suggest that 99mTc-HMPAO brain SPECT, when performed in the first weeks of life, can be useful in high-risk neonates to predict occurrence of major neurological handicaps. Because of the relative invasive character of HMPAO scan in neonates and the overall accuracy of the noninvasive tests, radionuclide examination should not be performed in every high-risk neonate. According to our results, 99mTc-HMPAO brain SPECT might be indicated in those children where noncongruent results were obtained with conventional studies.

Cerebral Palsy↗

[Neonatal abstinence syndrome: current and future aspects].

Pregnant heroin-addicted women constitute a major social problem that should not be ignored. Newborns may develop a neonatal abstinence syndrome (NAS). They present with behavioural troubles running a typical clinical course. The level of severity of NAS will be accurately determined, leading to definition of the most appropriate therapy. The best therapeutic formula appears to be paregoric elixir, mixed with phenobarbital if necessary. Least severe cases can be easily controlled by appropriate surrounding conditions. Pharmacological as well as physiopathological effects of opiates are described. Little is known about the long-term effects of opiate exposure; they apparently include frequent instrumental troubles. At the present time, the rapid intervention of a multidisciplinary team is recommended, taking charge of the mothers who should receive methadone in progressively tapering doses.

Female↗

Diagnosis of venous thrombosis in the legs using 81Krm venography.

Contrast venography, the accepted gold standard for the diagnosis of venous thrombosis of the leg, is a painful and invasive procedure with late side effects. There is controversy in literature reports about the sensitivity of 99Tcm-macroaggregated albumin (MAA) phlebography: indeed, using 99Tcm-MAA, poor results are obtained when one has to detect calf vein thrombosis. As with other isotopic procedures requiring a pedal injection of the tracer, the use of an injectable solution of 81Krm is a nonspecific method, based upon the abnormality in flow in the deep venous system which results from a deep venous thrombosis. However, when compared with 99Tcm-MAA, 81Krm offers theoretical advantages for phlebographic studies of the lower limbs. In this work 24 patients were studied both with contrast phlebography and with 81Krm. Although 81Krm provided images of high quality, there was a lack of sensitivity below the knee, where false negative results were observed. This could be explained by the fact that the radionuclide venographic procedures usually visualize only one or, in some cases, two of the three deep veins of the calf. Moreover, accurate differentiation between superficial and deep veins in the calf often appears difficult, even using a tourniquet.

Humans↗

Detection of bilateral and symmetrical anomalies in technetium-99m-HMPAO brain SPECT studies.

The detection of bilateral and symmetrical regional cerebral blood flow (rCBF) abnormalities requires knowledge of the antero-posterior rCBF distribution in normal subjects of all age groups. These data are very difficult to obtain in children for ethical reasons and in older subjects because of the necessity of recruiting a large number of healthy volunteers from each age group. Therefore, to obtain normal values of antero-posterior rCBF distribution, we have retrospectively selected a group of patients with a low probability of having cerebral lesions, whose 99mTc-HMPAO brain SPECT studies were analyzed semiquantitatively. Cerebellum/mean cerebral cortex index when compared to young adults was higher in the neonatal period, slightly lower between 2 mo and 15 yr, and more or less identical after 15 yr. Cortico/occipital indexes exhibit considerable changes during the first year of life due to important differences in maturation timing of cerebral cortical areas. After 1 yr, all cerebral cortical areas approximately displayed a parallel evolution. A slight increase in fronto/occipital and temporo/occipital indexes was, however, still observed during childhood, while in elderly subjects there was a trend towards a decrease in all cortico/occipital indexes (particularly in prefrontal and motor areas). Changes that occurred after 1 yr were, however, usually smaller than interindividual variation. Despite the large range of "normal" values, the antero-posterior analysis could be useful in various neurologic disorders, because it allows detection of symmetrical rCBF anomalies undiagnosed by the right-left analysis.

Adolescent↗

Technetium 99m mercaptoacetyltriglycine gamma camera clearance calculations: methodological problems.

Major sources of errors in the gamma-camera methods for the calculation of renal clearance are the accuracy of background correction for obtaining the true renal time-activity curve and the validity of the externally recorded pre-cordial activity as an estimate of the plasmatic time-activity curve. With technetium 99m mercaptoacetyltriglycine (99mTc-MAG3), because of its high protein plasma binding, one could expect minimal extravascular diffusion and hence a more accurate externally detected plasmatic curve. The high extraction rate should reduce the influence of the background, but, on the other hand, the effect of hepatobiliary excretion on the calculation of renal clearance might be significant. Our results suggest that the hepatobiliary excretion of 99mTc-MAG3 does not influence the gamma-camera renal clearance determination, even in patients with low renal function. However, the pre-cordial curve does not reflect accurately the plasmatic disappearance curve; its calibration with a single plasma sample taken at the 20th min is responsible for significant errors, probably because of an unfavourable ratio between the intravascular and extravascular activities at the 20th min.

Adult↗

Cerebral palsy: initial experience with Tc-99m HMPAO SPECT of the brain.

The outlook for children with cerebral palsy is determined by the severity of motor problems and the presence of associated disabilities, in which early detection remains a medical challenge. The authors studied 13 children (aged 13 months to 12 years) with cerebral palsy by means of single photon emission computed tomography (SPECT) of the brain with technetium-99m hexamethylpropyleneamineoxime (HMPAO). In all children with hemiplegia, SPECT demonstrated hypoperfusion in the hemisphere contralateral to the motor deficit. SPECT demonstrated normal findings in patients with mild diplegia; bilateral hypoperfusion in the superior motor cortex in patients with moderate di- or tetraplegia; and bilateral reduction of perfusion in the superior motor, inferior motor, prefrontal, and parietal cortices in patients with severe di- or tetraplegia. Results suggest that Tc-99m HMPAO SPECT of the brain is a valuable complementary tool for thorough neurologic assessment in cerebral palsy.

Brain↗