Head-scatter factors and effective x-ray source positions in a 25-MV linear accelerator.

The behavior of the effective source position and the correction factor associated with the collimator opening (head-scatter factor) were investigated for the 6- and 25-MV x-ray beams of a linear accelerator. The primary photon fluence was measured in air for square field sizes from 5 x 5 cm to 40 x 40 cm at distances from the nominal source of 80 to 140 cm, for open and wedged fields (wedge angle 60 deg). An inverse-square analysis shows that, for open fields, the effective source position of the accelerator is about the same (approximately 1 cm downstream) at 6 and 25 MV, for all field sizes. For the wedged fields, the effective source position depends on field size and ranges from about 2 to 4 cm. The head-scatter correction factors for given collimator settings were found to be essentially independent of distance at both energies.

Mathematics↗

Equivalent squares of irregular photon fields.

The tables of equivalent fields published by the British Journal of Radiology (BJR) are intended for calculation of depth-dose functions in rectangular photon fields. We have investigated the validity of the equivalent-field concept for fields of arbitrary shape over a range of photon energies, field sizes and depths. We show that the empirical scatter-radius function (Day function) used to generate the equivalent-field tables is a good approximation to the average over energy of normalized scatter-air ratios extracted from BJR beam data for depths up to 10 cm. However, this function tends to diverge from the data as depth increases. Accuracy can be improved by making the Day function depend on depth. Equivalent squares, determined by sector integration of the original or modified Day functions, are suitable for megavoltage photon-beam dose calculations at central-axis and off-axis points in irregular as well as rectangular fields.

Biometry↗

Head-scatter factors in rectangular photon fields.

Head-scatter factors were measured for a range of field sizes of rectangular shape from a linear accelerator that provides 6 and 25 MV photon beams. For a given field length and width, exchange of the inner and outer collimator pairs produces differences in the head-scatter factor of up to about 2% and 3% in open and wedged fields, respectively. Dependence on elongation deviates by up to 2% from that given by the equivalent squares. Such effects can easily be taken into account by using head-scatter data that have been directly measured in rectangular fields or by applying empirical corrections to values for square or equivalent square fields.

Biophysical Phenomena↗