Computer dosimetry of 192Ir wire.

The dosimetry of 192Ir linear sources with a commercial treatment planning computer system has been evaluated. Reference dose rate data were selected from the literature and normalized in a manner consistent with our clinical and dosimetric terminology. The results of the computer calculations are compared to the reference data and good agreement is shown at distances within about 7 cm from a linear source. The methodology of translating source calibration in terms of exposure rate for use in the treatment planning computer is developed. This may be useful as a practical guideline for users of similar computer calculation programs for iridium as well as other sources.

Brachytherapy↗

The effect of thickness of the waterproofing sheath on the calibration of photon and electron beams.

The TG-21 protocol recommends using a thin sheath for waterproofing an ion chamber used in the calibration of photon and electron beams. A thickness of 0.5 mm is suggested for a material having a composition and density close to that of water. This work investigates the effect on the calibration of photon beams ranging from Co60 to 25 MV, and electron beams ranging from nominal energies of 7-18 MeV, for changes in the thickness of the waterproofing sheath from 0.5 to 5.5 mm. For photon beams, a maximum change of 1.2% was found for the 25-MV x-ray beam. For electron beams, a maximum change of 0.5% was found for 10-MeV electrons. It is concluded that the thickness of the waterproofing sheath is not a very sensitive variable, assuming the thickness is between 0.5 and 2.0 mm.

Calibration↗

Film dosimetry of small electron beams for routine radiotherapy planning.

The characteristics of very small fields, 1 X 1 and 2 X 2 cm, of electron beams of nominal energies, 5, 7, 10, 12, 15, and 18 MeV have been studied and compared to a 10 X 10 cm field. A parallel-plate ion chamber and film have been used to obtain various dose parameters. The central axis depth dose measurements, field flatness, uniformity index, and relative output factors are presented. It was found that satisfactory results for determining the relative output factor can be obtained from film data using a scanning densitometer. It is our conclusion that film dosimetry is acceptable in determining the necessary clinical parameters needed to treat patients with fields as small as 2 X 2 cm. For the 1 X 1 cm field size and for the electron energies greater than 10 MeV, there was substantial disagreement between the ion chamber and film data in the buildup region as well as the regions beyond the depth of maximum dose to the depth of 90% dose.

Electrons↗

Performance characteristics of an orthovoltage x-ray therapy machine.

Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output factors, field flatness, uniformity index, and filtration characteristics of the beams are studied. Selected results are reported.

Humans↗

Comparison of measured and calculated dose distributions around an iridium-192 wire.

The relative dose distribution around a 5.0-cm-long piece of 192Ir wire has been measured using LiF chips. Measurements were made at distances of 0.25 to 5.0 cm away from the source and distances of 0.0 to 4.0 cm along the source. In addition, measurements were also made at several distances along the axis of the source. Attention was paid to the errors associated with these measurements. A comparison was made between a commercial software program, ISODOS, an analytical solution to the Sievert integral, and the measurements. Good agreement was obtained at distances along and away from the source. Major disagreements were found at points along the source axis.

Humans↗