Strategy for on-line preconcentration in chromatographic separations.

In chromatographic separations, the heights of peaks are proportional to the concentrations of sample components present in an injected mixture. In general, an increase in the peak height cannot be achieved by simply increasing the injection time or the sample plug length. An exception occurs if some form of on-line preconcentration is possible. We present a new strategy for achieving on-line preconcentration by the use of a porous chromatographic material that acts as a solid-phase extractor as well as a stationary-phase separator. We are able to realize significant on-line preconcentration using capillary columns filled with a photopolymerized sol-gel (PSG). More than 2-cm plugs of sample solution can be loaded into the capillary and concentrated using a running buffer that is the same as the injection buffer (to avoid solvent gradient effects). As a demonstration, mixtures of three different polycyclic aromatic hydrocarbons, eight different alkyl phenyl ketones, and five different peptides in solutions of aqueous acetonitrile have been injected onto the PSG column and separated by capillary electrochromatography. The preconcentration is marked in terms of peak heights, with up to 100-fold increase for the PAH mixture, 30-fold for the alkyl phenyl ketone mixture, and 20-fold for the peptide mixture. Preconcentration takes place because of the high mass-transfer rates possible in the highly porous structure, and the extent of preconcentration follows the retention factor k for a given analyte.

Journal Article↗

On-line preconcentration in capillary electrochromatography using a porous monolith together with solvent gradient and sample stacking.

Preconcentration effects of solvent gradient and sample stacking are investigated on a photopolymerized sol-gel (PSG) in capillary electrochromatography. The porous PSG monolith has a high mass-transfer rate. This characteristic promotes preconcentration of dilute samples. Plugs of samples more than 2 cm in length prepared in the separation solution (nongradient condition) are injected onto the PSG column. The extent of preconcentration is quite significant, showing up to a 100-fold increase in peak heights of the separated analytes. Even larger preconcentrations are achieved under gradient conditions by dissolving the sample in a matrix with a higher concentration of noneluting solvent (water). For eight alkyl phenyl ketones and four polycyclic aromatic hydrocarbons that serve as neutral test analytes, improvements in peak heights obtained under gradient conditions can be more than a 1000-fold. Indeed, injection of a 91.2-cm plug, which is more than 3 times the total length of the capillary, was possible with only a minor loss in resolution. Five peptides serve as charged test analytes. Nongradient conditions in which the sample is hydrodynamically injected onto the PSG column show sizable preconcentration because of sample stacking. The use of a solvent gradient with the same ionic strength, however, does not appear to have practical value because of destacking caused by the changing organic composition that affects the conductivity. As an alternative preconcentration method, we demonstrate that electric field-enhanced sample injection on the PSG yielded up to a 1000-fold improvement in detection sensitivity for the test peptides.

Angiotensin II↗

Photopolymerized sol-gel monoliths for capillary electrochromatography.

A solution of methacryloxypropyltrimethoxysilane in the presence of an acid catalyst, water, toluene, and a photoinitiator was irradiated at 365 nm for 5 min in a 75-microm i.d. capillary to prepare a porous monolithic sol-gel column by a one-step, in situ, process. The photopolymerized sol-gel (PSG) column shows reversed-phase behavior. Using this column, a variety of low-molecular-weight neutral compounds, including polycyclic aromatic hydrocarbons, alkyl benzenes, alkyl phenyl ketones, and steroids are separated from mixtures. Various different operational parameters, such as buffer composition, field strength, and column temperature, were varied to assess their influence on column performance. Use of PSG as a stationary phase for a pressure-driven separation is also demonstrated.

Journal Article↗

Photopolymerized sol-gel frits for packed columns in capillary electrochromatography.

Porous sol-gel frits are fabricated in a capillary column by filling it with a solution of 3-(trimethoxysilyl)propyl methacrylate, hydrochloric acid, water, toluene (porogen), and a photoinitiator (Irgacure 1800) and exposing it to UV light at 365 nm for 5 min. The separation column (30 cm x 75 microm I.D.) contains between the inlet and outlet frits a 15-cm packed segment filled with 5-microm silica particles modified with the chiral compound (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine. A detection window (1 mm long) is placed immediately after the outlet frit. To demonstrate the performance of this chiral separation column, mixtures of 16 different amino acids (three of which are not naturally occurring) derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole were separated by capillary chromatography. The enantiomeric separation of the column results in a resolution ranging from 1.21 to 8.29, and a plate height ranging from 8.7 to 39 microm.

Chromatography, Micellar Electrokinetic Capillary↗

Softening of fused-silica capillaries during particle packing.

When a semipreparative capillary electrochromatography (CEC) capillary is packed with silica particles and exposed to solvent, its mechanical strength is markedly reduced. In our studies, a fused-silica capillary (internal diameter > 200 microm and wall thickness < 150 microm) was packed under pressure (approximately 200 psi) with spherical silica particles (1.5-5 microm) suspended in water or various common organic solvents. After one hour of exposure, the capillary can be readily deformed, and it keeps its deformed shape upon release of the force causing deformation. It is suggested that capillary softening is promoted through the propagation of internal microcracks that have been caused by action of the particles during packing in the presence of solvent. Application of a protective coating to the inside of the capillary is found to reduce or eliminate capillary softening.

Chromatography, Liquid↗

Enantiomeric separation of amino acids and nonprotein amino acids using a particle-loaded monolithic column.

A solution is prepared of 5 microm silica particles modified with (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine (particle 1) or (S)-N-3,5-dinitrophenylaminocarbonyl-valine (particle 2) suspended in liquid tetraethylorthosilicate, ethanol, and aqueous hydrochloric acid. This solution is injected under pressure into a 30 cm long, 75 microm inner diameter capillary column and heated for 1 h at 120 degrees C after which the modified particles are embedded in a monolithic column of sol gel. The packed column measures approximately 15 cm from the inlet to the window used to view the laser-induced fluorescence. Thirteen different amino acids and three nonprotein amino acids are derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) before injection onto the column for capillary electrochromatographic separation. The enantiomeric separation of the monolithic column packed with particle 1 results in a resolution ranging from 1.14 to 4.45, whereas that packed with particle 2 results in a resolution ranging from 0.79 to 1.17. On the basis of resolution and amount of chiral packing material the enantiomeric separation obtained by capillary electrochromatography is judged to be superior to that obtained previously with high performance liquid chromatography (HPLC).

Amino Acids↗

Automated capillary electrochromatography: reliability and reproducibility studies.

The routine application of capillary electrochromatography (CEC) is demonstrated by incorporating 75 microns I.D. capillaries packed with 3 microns octadecylsilica (ODS) particles into a commercial CZE instrument. A mixture of several neutral compounds is separated into its components with an average efficiency up to 181 000 plates/m in less than 8 min. Hundreds of consecutive runs are performed over a period of weeks from which it is concluded that the reproducibility of the capacity factors is better than 2% and that CEC separations can be achieved in a reliable and routine manner.

Chromatography↗