Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures.

BACKGROUND AND OBJECTIVE: This study was performed to compare three disposable airway devices, the LMA Unique (LMA-U), the Ambu laryngeal mask (Ambu LM) and the Soft Seal laryngeal mask (Soft Seal LM) for elective general anaesthesia during controlled ventilation in non-paralysed patients. METHODS: One hundred and twenty ASA I-III patients scheduled for routine minor obstetric surgery were randomly allocated to the LMA-U (n = 40), Ambu LM (n = 40) or Soft Seal LM (n = 40) groups, respectively. Patients were comparable with respect to weight and airway characteristics. A size 4 LMA was used in all patients and inserted by a single experienced anaesthesiologist. Oxygenation, overall success rate, insertion time, cuff pressure and resulting airway leak pressure were determined as well as a subjective assessment of handling and the incidence of sore throat, dysphagia and hoarseness. RESULTS: Time of insertion was shortest with the Ambu LM, while failure rates were comparable with the LMA-U, the Ambu LM and the Soft Seal LM (median 19 s; range 8-57 s; success rate 100% vs. 14; 8-35; 97% vs. 20; 12-46; 95%). Insertion was judged 'excellent' in 75% of patients in the LMA-U group, in 70% of patients in Ambu LM group and in 65% of patients in the Soft Seal LM group. There was no difference between devices with respect to postoperative airway morbidity at 6 h or 24 h following surgery. CONCLUSIONS: All three disposable devices were clinically suitable with respect to insertion times, success rates, oxygenation, airway and leak pressures, as well as to subjective handling and postoperative airway morbidity.

Air Pressure↗

Monitoring of cerebral oxygenation with near infrared spectroscopy and tissue oxygen partial pressure during cardiopulmonary resuscitation in pigs.

BACKGROUND AND OBJECTIVE: The present study was designed to compare cerebral oxygenation measured with near infrared spectroscopy and local brain tissue oxygen partial pressure, respectively, in pigs during cardiopulmonary resuscitation. Since tissue overlying the brain may have an impact on near infrared spectroscopy readings, we tested whether optode placement on intact skin or on the skull yielded comparable results. METHODS: Twelve healthy pigs were anaesthetized and subjected to continuous haemodynamic, near infrared spectroscopy and brain tissue oxygen partial pressure monitoring. After 4 min of untreated ventricular fibrillation, cardiopulmonary resuscitation was started and arginine vasopressin was administered repeatedly three times. Near infrared spectroscopy values recorded were both the tissue oxygenation index and the tissue haemoglobin index as well as relative changes of chromophores (haemoglobin and cytochrome oxidase). Four animals served as control and were measured with both near infrared spectroscopy optodes mounted on the intact skin of the forehead, while in the remaining eight animals, one near infrared spectroscopy optode was implanted directly on the skull. RESULTS: Near infrared spectroscopy readings at the skin or at the skull differed consistently throughout the study period. After arginine vasopressin administration, near infrared spectroscopy values at the different locations showed a transient dissociation. In contrast to near infrared spectroscopy measured on intact skin, near infrared spectroscopy readings obtained from skull showed a significant correlation to brain tissue oxygen partial pressure values (r = 0.67, P < 0.001). CONCLUSION: Near infrared spectroscopy readings obtained from skin and skull differed largely after vasopressor administration. Near infrared spectroscopy optode placement therefore may have an important influence on the tissue region investigated.

Animals↗

The influence of xenon on regulation of the autonomic nervous system in patients at high risk of perioperative cardiac complications.

BACKGROUND: As xenon anaesthesia (XE) does not produce haemodynamic depression its use may be of benefit in patients at high risk of intraoperative haemodynamic instability and perioperative cardiac complications. XE (n=22) was compared with total i.v. anaesthesia (TIVA, n=22) for differences in autonomic regulation, peri- and postoperative performance. METHODS: Patients undergoing abdominal aortic surgery were studied at five events: T1: baseline awake; T2: anaesthesia induction; T3: before aortic cross-clamping; T4: after aortic cross-clamping; T5: after aortic declamping. T3-T5: end-tidal xenon concentration 60 (5)%. Intraoperative analysis: heart rate, heart rate variability, blood pressure and cardiac output. Postoperative analysis: 24 h Holter ECG, intensive care unit and hospital stay, and patient's outcome after 6 months. RESULTS: XE in contrast to TIVA increased parasympathetic and decreased sympathetic activity. Median low to high frequency decreased significantly in the XE group after start of XE (P<0.05) and remained significantly lower during all events after start of XE as compared with TIVA (P=0.0001). After start of XE heart rate of these patients was significantly lower as compared with TIVA (P=0.04). Cardiac output increased significantly in TIVA after aortic declamping (P<0.05). Outcome parameters did not differ significantly between groups. CONCLUSIONS: XE patients demonstrated lower sympathetic and higher parasympathetic activity as compared with TIVA patients. This was reflected by significant differences in haemodynamics but did not correlate with a better postoperative outcome. Thus, it remains controversial whether XE provides benefits in high risk patients.

Aged↗

Bispectral index-controlled anaesthesia for electroconvulsive therapy.

BACKGROUND: The suggested induction dose of methohexital for electroconvulsive therapy (ECT) varies widely influencing efficacy of ECT and safety of anaesthesia. Bispectral index (BIS), a monitor of consciousness, may be useful to assure adequate hypnosis with optimized methohexital dose. METHODS: Patients with medically resistant major depression (ICD10), scheduled for multiple ECT's, were studied. Depth of anaesthesia was BIS controlled. ECT was not performed until BIS dropped below 50. Initially anaesthesia was induced with methohexital 1.0 mg kg(-1), and stepwise reduced by 0.1 mg kg(-1) during consecutive treatments. If BIS did not drop below 50, the methohexital was supplemented by further boluses of 0.5 mg kg(-1), until the desired level of hypnosis was reached. The adequacy of the anaesthetic recommendation for methohexital (1.0-1.5 mg kg(-1)) as well as the psychiatric recommendation (0.75-1 mg kg(-1)) was investigated. RESULTS: One-hundred and nine ECT's in 14 patients were studied. The recommended anaesthetic dose (1.0-1.5 mg kg(-1)) was inadequate in 40% of the treatments, with 12% exceeding 1.5 mg kg(-1), and 28% below 1.0 mg kg(-1). Psychiatric recommendation (0.75-1.0 mg kg(-1)) was inadequate in 49%, with 39% exceeding 1.0 mg kg(-1) and 10% undershooting at 0.75 mg kg(-1). CONCLUSIONS: Methohexital for ECT showed a great variability, exceeding as well as undershooting the dosage recommendations widely. BIS monitoring may be useful to secure adequate hypnosis during muscle relaxation and treatment and may optimize ECT efficacy.

Aged↗

Changes of local brain tissue oxygen pressure after vasopressin during spontaneous circulation.

BACKGROUND: Brain tissue oxygen pressure (PbtO2) correlates to cerebral blood flow (CBF) during spontaneous circulation, with one important regulator being nitric oxide (NO). Although it is established that arginine vasopressin (AVP) improves CBF and global cerebral oxygenation during cardiopulmonary resuscitation, it is unknown whether similar beneficial effects are present during spontaneous circulation. The purpose of this study was to investigate the effects of AVP with and without pre-treatment with the NO synthase inhibitor N-omega-nitro-L-arginine methyl ester (L-NAME) on local brain tissue oxygenation in a beating heart model. METHODS: Following approval of the Animal Investigational Committee, nine healthy piglets underwent general anaesthesia, and were instrumented with a probe in the cerebral cortex to measure PbtO2. Each animal was assigned to receive AVP (0.4 U . kg(-1)), and after a wash-out period, L-NAME (25 mg x kg(-1) over 20 min) followed by AVP (0.4 U x kg(-1)). After each AVP administration, nitroglycerine (25 microg x kg(-1) over 1 min) as a NO donor was infused to test the vascular reactivity independently from NOS inhibition. FINDINGS: Three minutes after administration of AVP, PbtO2 increased significantly (P < .05; mean +/- SEM, 31 +/- 11 versus 43 +/- 14 mm Hg, +39%), compared with baseline. After pre-treatment with L-NAME, the changes of PbtO2 after AVP were not significant (32 +/- 11 versus 28 +/- 10, -13%) when compared with the baseline. CONCLUSION: In this beating heart porcine model, local brain tissue oxygenation was improved after AVP alone, but not after inhibition of NO synthesis with L-NAME.

Animals↗

Arginine vasopressin reduces cerebral oxygenation and cerebral blood volume during intact circulation in swine---a near infrared spectroscopy study.

BACKGROUND AND OBJECTIVE: The aim of the present study was to investigate the impact of arginine vasopressin (AVP), a drug currently under investigation for use during cardiopulmonary resuscitation, on cerebral oxygenation and cerebral blood volume (CBV) in pigs with intact systemic circulation using near infrared spectroscopy. METHODS: Nine healthy pigs were anaesthetized and subjected to invasive haemodynamic monitoring as well as to non-invasive determination (with near infrared spectroscopy) of changes in the Tissue Oxygenation Index (TOI is the ratio of oxygenated to total tissue haemoglobin), Tissue Haemoglobin Index (THI, representing CBV) and cytochrome oxidase (deltaCytOx, representing the balance of intracellular oxygen supply). RESULTS: At both 3 and 5 min after AVP administration, TOI, THI and deltaCytOx were significantly (P < 0.001) reduced compared to baseline, while cerebral perfusion pressure increased significantly (P < 0.001). The effects of AVP on TOI and THI lasted longer than on deltaCytOx. There were no significant changes with respect to the intracranial pressure throughout the study period. CONCLUSIONS: No improvement of cerebral oxygenation was detected after AVP administration in swine with an intact systemic circulation. In contrast to recently published investigations, AVP provoked a sustained drop in indices of cerebral oxygenation and CBV.

Animals↗

A comparison of the proseal laryngeal mask airway, the laryngeal tube S and the oesophageal-tracheal combitube during routine surgical procedures.

BACKGROUND AND OBJECTIVE: This study was performed to compare three supraglottic airway devices: the ProSeal laryngeal mask airway (PLMA), the laryngeal tube S (LTS) and the oesophageal-tracheal combitube (OTC) during routine surgical procedures. METHODS: Ninety American Society of Anesthesiologists (ASA) I-III patients scheduled for routine minor obstetric surgery were randomly allocated to the PLMA (n = 30), the LTS (n = 30) or the OTC (n = 30) group, respectively. The overall success rate, insertion time, cuff pressures and resulting airway leak pressures were determined as well as a subjective assessment of handling and the incidence of sore throat, dysphagia and hoarseness were performed. RESULTS: Insertion time until the first adequate ventilation was significantly (P < 0.0001) shorter in the PLMA (median 29 s; 25-75th percentile 25-48 s; range 10-161 s; success rate 100%) and in the LTS group (38 s; 30-44 s; 13-180 s; 100%) compared to the OTC group (75 s; 48-98 s; 35-180 s; 90%). In vivo cuff pressures and airway leak pressures increased with the inflating cuff volume in all devices and were highest in the OTC group. Postoperatively, patients in the PLMA and the LTS group complained significantly less about sore throat (P < 0.001 and 0.05) and dysphagia (P < 0.001 and 0.02) compared to the OTC group, while there was no difference regarding the incidence of hoarseness. Subjective assessment of handling was comparable with the PLMA and the LTS, but inferior with the OTC. CONCLUSIONS: In conclusion, both PLMA and LTS proved to be suitable for routine surgical procedures and proved to be superior to the OTC which cannot be recommended for routine use.

Blood Pressure↗

Comparison of xenon-based anaesthesia compared with total intravenous anaesthesia in high risk surgical patients.

Xenon, a noble gas with anaesthetic and analgesic properties, has gained renewed interest due to its favourable physical properties which allow a rapid emergence from anaesthesia. However, high costs limit its use to a subset of patients who may benefit from xenon, thereby offsetting its costs. To date, there are only limited data available on the performance of xenon in high risk patients. We studied 39 patients with ASA physical status III undergoing aortic surgery. The patients were randomly assigned to either a xenon (Xe, n = 20) or a TIVA (T, n = 19) group. Global cardiac performance and myocardial contractility were assessed using transoesophageal echocardiography, and myocardial cell damage with troponin T and CK-MB. Echocardiographic measurements were made prior to xenon administration, following xenon administration, and after clamping of the abdominal aorta, after declamping and at corresponding time points in the TIVA group. Laboratory values were determined repeatedly for up to 72 h. Data were analysed using two-way anova factoring for time and anaesthetic agent or with ancova comparing linear regression lines. No significant differences were found in global myocardial performance, myocardial contractility or laboratory values at any time during the study period. Mean (SEM) duration of stay on the ICU (xenon: 38 +/- 46 vs. TIVA 25 +/- 15 h) or in hospital (xenon: 14 +/- 12 vs. TIVA 10 +/- 6 days) did not differ significantly between the groups. Although xenon has previously been shown to exert superior haemodynamic stability, we were unable to demonstrate an advantage of xenon-based anaesthesia compared to TIVA in high risk surgical patients.

Aged↗

[Procedure optimization in hospital management].

Starting January 1st 2004 the German diagnosis-related group (DRG) system was established for in-patient cases. Consequently, the detection and realization of cost-saving potentials are becoming more and more important. For a successful future, efficient allocation of resources is essential. Economically, anaesthesia-related time delays during perioperative work-flow should be minimized. Since numerous entities contribute to perioperative care, it is extremely complex to analyze and optimize this process flow. In this publication single steps leading to an optimized perioperative process flow will be presented: documentation of predefined time points, calculation of relevant time intervals and analysis of key numbers for complex settings. Single steps of the given process analysis will be demonstrated using data from surgical patients at the University Hospital Schleswig-Holstein, Campus Kiel. The attached data collection sheets can be used by interested hospital departments and are meant to serve as a template for further process analyses. Based on the shown analysis, an example will be given to develop an optimized work-flow as a standard operating procedure (SOP). The implementation of the SOP module in an interdisciplinary clinical pathway (CP), which defines efficient medical care from admission to discharge, is mainly responsible for decreased process costs but increased quality of care.

Anesthesia Department, Hospital↗

[Implementation of an internal transfer pricing system for anaesthesia services].

Internal transfer pricing system (ITPS) of anaesthesia services is established to guarantee a close connection of delivered service and the budget of the department of anaesthesia. In most cases a time-based system is used with the pricing unit being calculated as the quotient from the enumerator "costs" divided by the denominator "anaesthesia time in minutes". The implementation of a transfer pricing system requires the identification of all relevant costs caused by the department of anaesthesia and a cost centre structure is needed which allocates all costs correctly according to their cause. The regulations regarding cost calculations as defined by the German DRG System should be considered. To generate valid data not only the necessary technical infrastructure is needed, but also detailed training of the staff and plausibility checks are needed to ensure correct and complete data. Subsequent agreements with the hospital administration are necessary in order to adjust the system if extrinsic cost increases occur. This paper gives a step-by-step guidance for the successful implementation of an internal transfer pricing system based on anaesthesia time.

Anesthesia Department, Hospital↗

A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways.

Tracheal intubation with the intubating laryngeal mask airway or the Bonfils intubation fibrescope was performed in 80 patients with predicted difficult airways. Mallampati score, thyromental distance, mouth opening and mobility of the atlanto-occipital joint were used to predict difficult airways. The overall success rate, time to the first adequate lung ventilation and time taken for the successful placement of the tracheal tube were recorded, as well as a subjective assessment of the handling of the device and the incidence of postoperative sore throat and hoarseness. The median [range] time to the first adequate ventilation was significantly shorter with the intubating laryngeal mask airway than with the Bonfils intubation fibrescope (28 [6-85] s vs. 40 [23-77] s, p < 0.005). Tracheal intubation was significantly slower with the intubating laryngeal mask airway than with the Bonfils intubation fibrescope (76 [45-155] s vs. 40 [23-77] s, p < 0.0001. Patients in the Bonfils group suffered less sore throat and hoarseness than those in the other group.

Adolescent↗

Effect of xenon anaesthesia on accuracy of cardiac output measurement using partial CO2 rebreathing.

Cardiac output (CO) determination based on partial CO(2) rebreathing has recently been introduced into clinical practice. The determination of flow is crucial for exact CO readings and the physical properties of xenon, i.e. high density and viscosity, may influence flow readings. This study compared echocardiography-derived CO measurements with the partial rebreathing method during total intravenous (TIVA) vs. xenon-based anaesthesia. Thirty-nine patients ASA physical status III undergoing aortic reconstruction were randomly assigned to receive either xenon (Xe, n = 20) or TIVA (T, n = 19) based general anaesthetic. Paired measurements were taken before xenon administration, after xenon administration, before and after clamping of the abdominal aorta and after declamping and at corresponding time points in the TIVA group. Data were analysed with a Bland-Altmann plot. Bias and precision were acceptable and comparable before xenon administration (T 0.54 +/- 0.92 l.min(-1) vs. Xe 0.11 +/- 1.1 l.min(-1)), but after xenon administration CO was largely overestimated by partial CO(2) rebreathing (T 0.04 +/- 0.91 l.min(-1) vs. Xe -4.0 +/- 2.1 l.min(-1)). In the TIVA group, bias and precision after declamping increased significantly (P < 0.01) compared to all time points except baseline. In its current application, the NICO cardiac output monitor appears to be inappropriate for determination of CO during xenon based anaesthesia.

Aged↗

Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy.

Failed tracheal intubation due to a difficult airway is an important cause of anaesthetic morbidity and mortality. This study was undertaken to evaluate the effectiveness of the Bonfils intubation fibrescope for tracheal intubation after failed direct laryngoscopy. Twenty-five patients undergoing coronary artery bypass grafting were enrolled in the study after two attempts at conventional laryngoscopy by a board certified anaesthetist had failed. Intubation with the Bonfils fibrescope was successful on the first attempt in 22 patients (88%) and on the first or second attempt in 24 patients (96%); in one patient intubation was impossible. Median (IQR [range]) time to intubation using the Bonfils intubation fibrescope was 47.5 (30-80 [20-200]) s. Tracheal intubation using the Bonfils intubation fibrescope appears to be a simple and effective technique for the management of a difficult intubation.

Aged↗

Establishment of T cell-specific and natural killer cell-specific unigene sets: towards high-throughput genomics of leukaemia.

We report the establishment of highly non-redundant unigene sets consisting of cDNA clones derived from T lymphocytes and natural killer cells. Each set consists of 10 506 and 13 409 clones, respectively, arrayed on nylon membranes in duplicate. The sets provide an excellent tool for genome-wide gene expression analysis studies in immunology research.

Blotting, Northern↗

Automated image analysis for array hybridization experiments.

MOTIVATION: Image analysis is a major part of data evaluation for array hybridization experiments in molecular biology. The program presented here is designed to analyze automatically images from hybridization experiments with various arrangements: different kinds of probes (oligonucleotides or complex probes), different supports (nylon filters or glass slides), different labeling of probes (radioactively or fluorescently). The program is currently applied to oligonucleotide fingerprinting projects and complex hybridizations. The only precondition for the use of the program is that the targets are arrayed in a grid, which can be approximately transformed to an orthogonal equidistant grid by a projective mapping. RESULTS: We demonstrate that our program can cope with the following problems: global distortion of the grid, missing of grid nodes, local deviation of the spot from its specified grid position. This is checked by different quality measures. The image analysis of oligonucleotide fingerprint experiments on an entire genetic library is used, in clustering procedures, to group related clones together. The results show that the program yields automatically generated high quality input data for follow up analysis such as clustering procedures. AVAILABILITY: The executable files will be available upon request for academics.

Algorithms↗