Search PubMed⌕ Search

Biomedical subjects

M Simón

Publications and source records attributed to M Simón.

17 recordsLinked to original sources

Soil pollution by oxidation of tailings from toxic spill of a pyrite mine.

On the 25th April 1998, toxic water and tailings from a pyrite mine of Aznalcóllar (southern Spain) spilled into the Agrio and Guadiamar River Basin affecting some 40 km2. In five sectors throughout the basin, we monitored the physical and chemical properties of the tailings as well as the degree of pollution in the soils on four different sampling dates: 5 May, 20 May, 4 June and 22 July 1998. The characteristics of the tailings deposited on the soils are shown to be related to distance from the spill. The oxidation rate of the tailings and the solubilization of the pollutant elements were more pronounced in the middle and lower sectors of the basin, where the particle size was finer, the sulfur content higher and the bulk density less. The increases in water-soluble sulfates, Zn. Cd and Cu were very rapid (the highest values being reached 25 days after the spill) and intense (reaching 45% of the total Cu, 65% of the total Zn and Cd). Meanwhile, the increases in water-soluble As, Bi, Sb, Pb and Tl were far lower (ranging between 0.002% of the total Tl and 2.5% of the total As) and less rapid in the case of As, Bi and Pb (the highest values for these elements being reached 40 days after the spill). These soluble elements infiltrated the soils with the rainwater, swiftly augmenting the soil pollution. Twenty-five days after the spill, when the rainfall ranged between 45 and 63 mm, the first 10-cm of the soils in the middle and lower sectors of the basin exceeded the maximum concentration permitted for agricultural soils in Zn, Cu and Tl. At 40 days after the spill, when the rainfall ranged between 60 and 89 mm, all the soils reached or exceeded the maximum permitted concentrations for As and Tl. Nevertheless, the pollutants tended to concentrate in the first 10 cm of the soils without seriously contaminating either the subsoil or the groundwaters. Consequently, a rapid removal of the tailings and the ploughing of the first 25-30 cm of the soils would be urgent measures to diminish pollutant concentration in the soils affected by the spill.

Environmental Monitoring↗

[Pharmacovigilance study of azithromycin tablets (500 mg) in the treatment of adult patients with respiratory tract infections].

Our aim was to study a new form of azithromycin (500 mg tablets) in order to evaluate the tolerability and the influence of the ingestion of food on tolerability, the efficacy and treatment compliance in a large number of patients with respiratory tract infections. We carried out an open, non-comparative, multicenter, observational and prospective pharmacovigilance study of 3223 outpatients with respiratory tract infections randomly assigned to receive a daily dose of azithromycin for three months taken either during or outside meals. Patients were evaluated during an initial visit and two later ones in order to record the adverse events and establish the clinical efficacy. The diagnostics were as follows: pharyngotonsillitis (1200), acute otitis media (394), acute bronchitis (1134), exacerbation of chronic bronchitis (436), and community-acquired pneumonia (53). The overall therapeutic efficacy was satisfactory (cure or improvement) in 96% to 97% at the second visit and in 93% to 94% in the third (pharyngotonsillitis, 93%; acute otitis media, 91%; acute bronchitis, 94%; exacerbation of chronic bronchitis, 94%; and community-acquired pneumonia, 96%). A total of 170 adverse events were reported in 141 patients (4.4%); 12 were severe yet not related to the study medication. Eighty-eight patients showed adverse events presumed to be related to azithromycin; most were in the digestive tract. No differences in tolerability were observed in relation to food intake. Treatment compliance was high (97%). The elevated clinical efficacy, adequate compliance and the excellent tolerability profile of azithromycin tablets make them a safe and effective alternative in the treatment of respiratory tract infections.

Adolescent↗

Pollution of soils by the toxic spill of a pyrite mine (Aznalcollar, Spain).

On 25 April 1998 the retention walls broke open in a pond containing the residues from a pyrite mine of Aznalcollar (southern Spain), spilling some 45 x 10(5) m3 of polluted water and toxic tailings into the Agrio and Guadiamar River basin, affecting some 55 km2. On 5 May, seven sectors in the affected area were studied, analysing tailings, polluted water, and contaminated as well as uncontaminated soils. The principal pollutants were: Zn, Pb, Cu, As, Sb, Bi, Cd and Tl. The range of total contamination of each element was extremely broad, as penetration of the tailings depended on the soil characteristics. Most of the Cu, Zn and Cd penetrated the soil in the solution phase of the spill, while the other elements penetrated mostly as part of the solid phase. Zn exceeded the maximum concentrations permitted by the international community in four of the seven sectors studied, As in three, and the other elements only in one sector. Drying and consequent aeration of the tailings rapidly oxidized sulphides to sulphates, lowered the pH and solubilized the pollutants. Therefore, future rains could aggravate the pollution problem, if the tailings are not quickly removed.

Accidents, Occupational↗

Commutability and traceability: their repercussions on analytical bias and inaccuracy.

The commutability of calibrators and accuracy control materials affects the traceable link between patient sample results and standards. We sought to identify the repercussions of commutability on various aspects of laboratory practice (calibration, control of bias and accuracy assessment) and to discover the solutions that can reduce the problems produced by non-commutability with presently available resources. Ten serum constituents, ten comparison procedures and 37 analytical procedures were studied. The information concerning accuracy and bias provided from materials found to be commutable in previous works was challenged with native serum results for each routine and reference method compared, using Passing-Bablok regression and decision limits derived from biological variation. We found that: (1) Use of commutable control materials did not assure reliable information on the bias (systematic component of analytical error) of analytical procedures, and (2) Results from native serum and commutable controls were very highly concordant, indicating that these materials provide a good indication of the inaccuracy (total analytical error) of results. We suggest that the performance of individual laboratories would be better evaluated by occasional use of native sera with values assigned by reference methods in EQAS schemes. Moreover, our findings support the idea that manufacturers should assign values to calibrators using reference methods and native sera to reduce matrix effects and promote traceability.

Calibration↗

Current databases on biological variation: pros, cons and progress.

A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.

Clinical Laboratory Techniques↗

Our experience with Wallstent self-expanding metal prostheses in 65 patients with malignant dysphagia.

OBJECTIVE: to document the usefulness of self-expanding metal stents in patients with malignant dysphagia. METHOD: from January 1992 to January 1997 we implanted 75 Wallstent prostheses (28 uncovered AV, 20 uncovered Unistep, 15 covered Telestep, and 2 covered double-mesh Permalume stents) in 65 patients with malignant dysphagia. RESULTS: mean survival time was 100 days in patients with uncovered stents, and 215 days in patients with covered stents. Oral feeding was possible throughout the post-implantation course in 58 of 65 patients. Only two severe complications occurred: esophageal perforation with mediastinitis, and migration of the stent from the distal esophagus into the stomach. All implantation procedures were done under radiological guidance. For AV and Unistep prostheses we used a nasal approach without sedation, and for Telestep and Permalume stents we used an oral approach with sedation. CONCLUSIONS: Wallstent self-expanding metal stents are useful in palliating malignant dysphagia. The placement and implantation of these stents are straightforward.

Adult↗

Synthesis and evaluation of tacrine-huperzine A hybrids as acetylcholinesterase inhibitors of potential interest for the treatment of Alzheimer's disease.

Seventeen polycyclic compounds related to tacrine and huperzine A have been prepared as racemic mixtures and tested as acetylcholinesterase (AChE) inhibitors. The conjunctive pharmacomodulation of huperzine A (carbobicyclic substructure) and tacrine (4-aminoquinoline substructure) led to compound 7jy, 2.5 times less active than tacrine as AChE inhibitor, but much more active than its (Z)-stereoisomer (7iy). Derivatives 7dy and 7ey, lacking the ethylidene substituent, showed to be more active than tacrine. Many other structural modifications of 7jy led to less active compounds. Compounds 7dy and 7ey also showed to be much more active than tacrine in reversing the partial neuromuscular blockade induced by d-tubocurarine.

Acetylcholinesterase↗

Evaluation of the immunospecificity of the porin Om1 of Vibrio anguillarum serotype O1.

Three methods of immunoanalysis (immunoblot, ELISA and dot-blot) were used to evaluate the immunospecificity of the antiserum against the porin Om1 of Vibrio anguillarum serotype O1 with respect to all the serotypes of V. anguillarum, different Vibrio species and other Gram-negative genera. In the immunoblot analysis of the outer membrane proteins, this antiserum cross-reacted with the main outer membrane protein (MOMP) of all the Vibrio strains studied but not with other genera, except Plesiomonas shigelloides. However, when analyses were performed using whole cells as antigens (ELISA and dot-blot), the antiserum was more specific for V. anguillarum.

Animals↗

Procedure for studying commutability validated by biological variation.

In the field of laboratory medicine, the two quantitative approaches designed to identify the stabilized materials that produce results that are commutable with results from patients' samples were found to differ. In commutability evaluations, the responses of each material and each method studied are specific, thus, it is vital to standardise the procedure used for determining this characteristic. We incorporated statistical components from the two described methods that seemed to be consistent, and added a new element based on biological variation, to validate the criterion of acceptability that determines whether or not a material is commutable. The three methods for studying commutability (using the confidence interval [alpha = 0.05], the +/- 2s(yx) formula, and the limit based on biological variation as acceptability criteria) were applied to creatinine results from 31 stabilised materials and serum samples analysed with seven instruments, when compared against a reference method for creatinine analysis. Over the wide range of concentrations studied, the confidence interval limit and the biological variation limit coincided in the identification of commutable materials, whereas the +/- 2s(yx) was excessively permissive at normal and low concentration levels. We therefore recommend the use of Passing-Bablok regression with its confidence interval (alpha = 0.05) in studies concerning commutability. Using this method, commutability is simple to calculate with available software and, as validated by biological variation, results are reliable.

Chromatography, High Pressure Liquid↗

Commutability between stabilized materials and fresh human serum to improve laboratory performance.

With the recent advances in laboratory technology, many quality-related problems have been improved. However, the issue of commutability, a factor that greatly affects daily decisions concerning patient status, still remains to be solved. This paper determines the commutability between 27 stabilized materials (controls and calibrators) and clinical specimens for five serum quantities, using carrier-bound reagent chemistry and conventional wet methods. Our aim was to pinpoint the specific problems related to non-commutable calibrators and controls in our setting, and minimize their effect in daily practice. We found major difficulties in selecting appropriate accuracy controls in carrier-bound reagent techniques, and in finding materials commutable for several analytes simultaneously. Several suggestions for reducing problems related to non-commutability, such as procedures for assigning values to multicalibrators, are proposed. We explain the apparent incongruencies observed in daily quality surveillance, when data from different control materials (internal quality control and external quality assessment) are evaluated. The conclusions emphasize the need for a combined effort (manufacturers, organizers of external quality assessment schemes and individual laboratories) to find the cause of, and eliminate, the negative repercussions on laboratory performance produced by non-commutability.

Blood Chemical Analysis↗

Characterization of a porin from the outer membrane of Vibrio anguillarum.

The outer membranes of the 10 serovars of Vibrio anguillarum showed a common major protein with a size of around 40 kDa. Antibodies against the major outer membrane protein (MOMP) of V. anguillarum AO18 (serovar O1) cross-reacted with the MOMPs of all the other serovars but not with the outer membrane proteins of Escherichia coli. The MOMP of V. anguillarum serovar O1 was isolated, reconstituted to two-dimensional crystals, and structurally characterized by electron microscopy and image processing. The unit cell structure of the crystalline MOMP, as well as the secondary structure composition of the protein with a high amount of beta-structure, is strongly reminiscent of that of bacterial porins. The functional properties of the pores were investigated by conductance measurements with the MOMP reconstituted in planar lipid membranes. The V. anguillarum MOMP is characterized by a relatively weak cation selectivity and a moderate surface charge, and it shows voltage-dependent conductance effects. The MOMP is functionally similar to OmpF from E. coli, and it can be classified as a general diffusion porin.

Biological Transport↗

Biological variation in urine samples used for analyte measurements.

To determine the influence of biological variation on the reliability of data from different types of urine specimens, we measured nine analytes in first-morning, randomly collected, and 24-h samples of urine from 53 healthy individuals (14 men and 39 women). The urines were collected once a week for 10 weeks. The data obtained were used as a basis for specimen collection and to gain insight into the influence of urine quantities in the diagnosis, screening, and monitoring of patients. We found that 24-h urine expressed in output rather than concentration units is the most reliable specimen for diagnosis and monitoring for most of the analytes studied. On the basis of the ratio between estimated within- and between-subject variation, the tests with greatest medical usefulness for diagnosis and screening of specific pathologies are those measuring protein and sodium. Moreover, the results indicate that urine creatinine may be a poor test for diagnosis, monitoring, and screening.

Adult↗

[Transferability of results in hematologic determinations].

PURPOSE: To evaluate inaccuracy of the results attained in several Servei Catalá de la Salut laboratories in order to assess if quality purposes are accomplished and results are transferable between them. MATERIAL AND METHODS: Two types of haematological analysers are used: those based upon volumetric measurements and those using light dispersion for particle counting. Inaccuracy was ascertained in accordance to the inter-laboratory quality control programme. The inter-series study was performed with commercial control material in each laboratory with their own data, the monthly coefficient of variation being found, and the mean of the CV of 12 months was then calculated. Intra-series inaccuracy with commercial control material was assessed in each laboratory three times a day for 10 days, and the inaccuracy with fresh patient blood was examined daily in triplicate. The analytical inaccuracy attained in patient samples was also compared with that attained with stabilized control materials. RESULTS: The inaccuracy quality limits were exceeded in the haematological constituents under study. Quality objectives were accomplished in the inter-series inaccuracy study for red cell count, white cell count, MCV, granulocytes and lymphocytes. Repeat fresh patient-blood assays can be used to assess intra-series inaccuracy for red and white cell counts, but not for platelet count. CONCLUSIONS: Inaccuracy of the blood constituents studied is not transferable. Inaccuracy for the commonest haematological values is transferable between laboratories. Intra-series inaccuracy for red and white cell counts can be assessed by repeated use of fresh patient-blood when control material is not available. Patient samples are not advisable as a control of the white cell differential count for intra-series inaccuracy studies in those systems using volumetric principles.

Blood Cell Count↗

Migration of trace elements from pyrite tailings in carbonate soils.

In the carbonate soils contaminated by a toxic spill from a pyrite mine (Aznalcóllar, southern Spain), a study was made of a thin layer (thickness = 4 mm) of polluted soil located between the pyrite tailings and the underlying soil. This layer, reddish-yellow in color due to a high Fe content, formed when sulfates (from the oxidation of sulfides) infiltrated the soil, causing acidification (to pH 5.6 as opposed to 8.0 of unaffected soil) and pollution (in Zn, Cu, As, Pb, Co, Cd, Sb, Bi, Tl, and In). The less mobile elements (As, Bi, In, Pb, Sb, and Tl) concentrated in the uppermost part of the reddish-yellow layer, with concentration decreasing downward. The more mobile elements (Co, Cd, Zn, and Cu) tended to precipitate where the pH was basic, toward the bottom of the layer or in the upper part of the underlying soil. The greatest accumulations occurred within the first 6 mm in overall soil depth, and were negligible below 15 mm. In addition, the acidity of the solution from the tailings degraded the minerals of the clay fraction of the soils, both the phyllosilicates as well as the carbonates. Also, within the reddish-yellow layer, gypsum formed autigenically, together with complex salts of sulfates of Fe, Al, Zn, Ca, and Mn, jarosite, and oxihydroxides of Fe.

Hazardous Substances↗

[Nabumetone].

Explore the source record for details and available documents.

Adult↗