A polyhydroxybutyrate biodegradable stent: preliminary experience in the rabbit.

PURPOSE: The lifelong persistence of foreign bodies within the arteries may contribute to restenosis. Thus, biodegradable devices might decrease recurrence rates. METHODS: Eleven polyhydroxybutyrate biodegradable stents and 13 tantalum stents were implanted into the iliac arteries of New Zealand white rabbits for up to 30 weeks. After killing the animals, the specimens were harvested, fixed in formalin, processed in paraffin, and stained. RESULTS: Polyhydroxybutyrate instigated intense inflammatory and proliferative reactions with an increase in collagen (2.4- to 8-fold vs native segments), thrombosis and in-stent lumen narrowing (375.5-606.6 mm vs 655.6 +/- 268.8 mm in native segments). The elastic membranes were destroyed in all specimens. The tantalum stents increased the in-stent lumen progressively (769.7 +/- 366.6 mm vs 1309.9 +/- 695.3 mm), penetrated the external elastic membrane, and increased mural collagen content (6- to 8.6-fold vs native segments). Neither restenoses nor thromboses occurred. CONCLUSIONS: In the rabbit iliac artery, polyhydroxybutyrate stents caused intensive inflammatory vascular reactions which ban them from clinical use.

Animals↗

Prevention of surface encrustation of urological implants by coating with inhibitors.

The encrustation of materials used for urological implants is as yet an unresolved problem. The crystallisation-inhibiting effect of the glycosaminoglycan heparin was used to reduce encrustation. Heparin was covalently bound to the surface of slotted-tube stents of tantalum and stainless steel using a spacer molecule. To verify the inhibition of crystallisation processes, reproducible in vitro tests and in vivo tests using the rat as animal model were carried out. The in vitro and in vivo experiments showed that the heparin coating has a significant influence on the encrustation of the surface. After 7 days in vitro and 120 days in vivo, heparin coated stents were free of encrustation, whereas the uncoated reference stents were extensively covered.

Animals↗

A new detection algorithm for implantable cardioverter defibrillator.

One of the most important subsystems of implantable cardioverter defibrillator (ICD) is the sensing stage, since it determines the sensitivity and specificity of the device to detect the heart rate and the underlying arrhythmia. This paper aims to investigate a new detection algorithm for ICD, which operates fully automatically. The algorithm ARGUS was implemented as a computer model and tested with intracardiac electrograms recorded (band-pass: 0.05 to 500 Hz; sampling rate: 1-4 kHz) under different rhythm condition like sinus rhythm (n = 18), atrial tachycardia (n = 16), and ventricular tachycardia as well as fibrillation (n = 139) during electrophysiological tests or ICD implantation. The results of the tests were visually inspected on a beat-to-beat basis. In total 31,934 events were classified by the algorithm (18,758 as long intervals (LI) with cycle length > 300 ms; 13,176 as short intervals (SI)). 195 out of the 13,176 SI and 572 out of 18,758 LI were incorrectly classified (SI: 1.48%; LI: 3.05%). In conclusion the new algorithm yield high sensitivity (99.9%) and specificity (97.0%) as known from conventional ICD algorithms but need no manual adjustments.

Algorithms↗

Dynamic cardiomyoplasty: long-term clinical results in patients with dilated cardiomyopathy.

BACKGROUND: Dynamic cardiomyoplasty has been considered to be an effective method of surgical treatment of patients with end-stage heart failure, and is an alternative to heart transplantation. METHODS: We critically evaluated the long-term course of 52 patients with dilated cardiomyopathy who underwent dynamic cardiomyoplasty and were followed-up for up to 110 months. RESULTS: Dilated cardiomyopathy was due to undetermined cause in 42 patients (80.8%), Chagas disease in 8 (15.4%), viral infection in 1 (1.9%), and peripartum cardiomyopathy in 1 (1.9%). In the nonchagasic group the survival rates were 79.5% +/- 6.1%, 67.8% +/- 7.1%, 53.7% +/- 8.3%, 49.9% +/- 8.3%, 14.9% +/- 12.2%, and 14.9% +/- 12.2%, respectively, at 12, 24, 48, 60, 80 and 110 months of follow-up. In the chagasic patients the survival rates were 37.5% +/- 17.1%, 12.5% +/- 11.7%, 12.5% +/- 11.7% and 0%, respectively, at 12, 24, 48, and 60 months of follow-up, making chagasic cardiomyopathy a possible contraindication for dynamic cardiomyoplasty. CONCLUSIONS: There was no correlation between the clinical improvement and hemodynamic data. Ventricular fibrillation was a frequent cause of immediate and late death, suggesting the need for prophylactic use of antiarrhythmic drugs or implantable cardioverter/ defibrillators.

Adolescent↗

Closed-loop stimulation using intracardiac impedance as a sensor principle: correlation of right ventricular dP/dtmax and intracardiac impedance during dobutamine stress test.

Changes of the unipolar right ventricular impedance during the cardiac cycle are related to the changing content of blood (low impedance) and tissue (high impedance) around the tip of the pacing electrode. During myocardial contraction, the impedance continuously increases reaching its maximum in late systole. This impedance increase is thought to correlate with right ventricular contractility, and thus, with the inotropic state of the heart. In the new Inos2 DDDR pacemaker, integrated information from the changing ventricular impedance (VIMP) is used for closed-loop regulation of the rate response. The aim of this study was to analyze the effect of increasing dobutamine challenge on RV contractility and the measured impedance signals. In 12 patients (10 men, 68 +/- 12 years) undergoing implantation of an Inos2 DDDR pacemaker (Biotronik), a right ventricular pigtail catheter was inserted for continuous measurements of RV-dP/dtmax and simultaneous VIMP signals during intrinsic and ventricular paced rhythm. Then, a stress test with a stepwise increase of intravenous dobutamine (5-20 micrograms/kg per min) was performed. To assess the relationship between RV contractility and measured sensor signals, normalized values of dP/dtmax and VIMP were compared by linear regression. There was a strong and highly significant correlation between dP/dtmax and VIMP for ventricular paced (r2 = 0.93) and intrinsic rhythm (r2 = 0.92), although the morphologies of the original impedance curves differed quite substantially between paced and intrinsic rhythm in the same patient. Furthermore, VIMP correlated well with sinus rate (r2 = 0.82), although there were at least four patients with documented chronotropic incompetence. We conclude, that for intrinsic and ventricular paced rhythms sensor signals derived from right ventricular unipolar impedance curves closely correlate with dP/dtmax, and thus, with a surrogate of right ventricular contractility during dobutamine stress testing. Our results suggest that "inotropy-sensing" via measurement of intracardiac impedance is highly accurate and seems to be a promising sensor principle for physiological rate adaptation in a closed-loop pacing system.

Aged↗

The effects of orthostasis on the ventricular-evoked response.

AIMS: The effects of orthostasis on the morphology of the ventricular-evoked response were investigated. METHODS AND RESULTS: Seven patients (five females; 74.9 +/- 4.6 years) with second- or third-degree atrioventricular block received DDD pacemakers Physios CTM 01 with fractal-coated ventricular leads (both Biotronik, Germany). At their 3-month follow-up sessions, these patients underwent tilt-table tests. Heart rate, mean arterial blood pressure and ventricular-evoked response were measured continuously. Signals were averaged over 15 consecutive beats. Coefficients of correlation between selected ventricular-evoked response parameters and heart rate or mean arterial blood pressure were calculated. Tilt upwards affected heart rate, mean arterial blood pressure and ventricular-evoked response extremes showed non-uniform, patient-specific changes that were not related directly to other parameters. Heart rates significantly increased in six patients following tilt upwards. For all patients, ventricular-evoked response plateau amplitudes immediately increased with tilt upwards. Furthermore, repolarization times correlated with changes in heart rates (r = -0.78). CONCLUSIONS: Monitoring of the ventricular-evoked response during tilt-table testing revealed that the plateau amplitude of the ventricular-evoked response depends on the patient's position; ventricular-evoked response increased in the upright position and decreased in the supine position. Furthermore, repolarization time and heart rate correlated inversely; higher heart rates resulted in a shortening of the ventricular-evoked response.

Aged↗

Ventricular evoked response in patients with hypertrophic obstructive cardiomyopathy treated with DDD pacing.

OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150 ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 +/- 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22 mmHg). An AV delay > 100 ms produced a significantly lower decrease in VER depolarization duration (VERDD) when compared to an AV delay < or = 100 ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r = 0.69; p < 0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.

Adolescent↗

Non-invasive temperature imaging of muscles with magnetic resonance imaging using spin-echo sequences.

The application of spin-echo magnetic resonance imaging sequences on non-invasive temperature imaging for temperature mapping of human limbs is investigated. In an in vitro experiment performed on a meat sample, the equilibrium magnetisation P and the spin-lattice relaxation time T1 are calculated from the values for the repetition time TR and the signal intensities obtained by a spin-echo sequence at different tissue temperatures as measured by a fibre-optic probe. T1 is linearly correlated to the tissue temperature, and P is linearly correlated to the reciprocal value of the absolute temperature. Both effects, taken together, lead to a non-linear dependency of the signal intensity on temperature. Therefore a TR leading to maximum temperature dependency of the signal intensity is calculated and used in the further experiments. In the in vivo experiments, the lower legs of two volunteers are cooled from outside. Images are acquired with a spin-echo sequence (1.5 T, TR = 1200 ms, TE = 10 ms). A rise in signal intensity in the muscle with falling skin temperature is observed, particularly in more peripheral muscle layers. This study shows that spin-echo sequences can be used to monitor temperature changes and temperature differences in living muscle tissue.

Animals↗

Increased monophasic action potential dispersion in endothelin-1-induced ventricular arrhythmias.

The aim of this study was to investigate the changes in monophasic action potentials (MAP) from different sites in the heart and to determine MAP dispersion during endothelin-1 (ET-1) infusion. Standard ECG, left ventricular anterior, right ventricular lateral, right ventricular septal, and right ventricular apical MAPs and intra-arterial blood pressure were monitored in seven anesthetized open-chest mongrel dogs. After radiofrequency atrioventricular node ablation, ventricular pacing (70/min) was performed and intracoronary ET-1 (60 pmol/min) was administered into the left anterior descending coronary artery. Both MAPd90 and MAPd90 dispersion increased significant during ET-1 infusion. The onset of spontaneous monomorphic and polymorphic sustained ventricular tachycardias (sVT) was observed in five dogs (around 40 min), and nonsustained VTs (nsVT) developed in another two dogs. The increases in MAP and MAP dispersion lasted until the appearance of polymorphic nsVTs and sVTs, but at the time of these VTs this difference decreased. At the termination of the experiments, ventricular fibrillation occurred in six cases. In four cases third-phase early afterdepolarizations were recorded. Our results suggest that increased MAP dispersion and development of EAD contribute to the arrhythmogenic action of ET-1, and these phenomena might explain the pathogenesis of a wide variety of ventricular arrhythmias with different morphology observed in this study.

Action Potentials↗

A fractally coated, 1.3 mm2 high impedance pacing electrode.

Minimizing the geometric surface area of pacing electrodes increases impedance and reduces the current drain during stimulation, provided that voltage (pulse-width) thresholds remain unchanged. This may be feasible by coating the electrode surface to increase the capacity of the electrode tissue interface and to diminish polarization. Ten unipolar, tined leads with a surface area of 1.3 mm2 and a "fractal" coating of iridium (Biotronik SD-V137) were implanted in the ventricle, and electrogram amplitude (unfiltered), slew-rate, pacing threshold (0.5 ms), and impedance (2.5 V; 0.5 ms) were measured by the 5311 PSA (Medtronic). On days 0. 2. 5. 10, 28, 90, 180, 360 postimplant, sensing threshold (up to 7.0 mV, measuring range 1-14 mV on day 360 only) and the strength duration curve (0.5-4.0 V; 0.03-1.5 ms; steps: 0.5 V; 0.01 ms, respectively) were determined, the minimum charge delivered per pulse (charge threshold), and the impedance were taken from pacemaker telemetry (Intermedics 294-03). Data were compared with those of an earlier series of 20 unipolar, tined TIR-leads (Biotronik) with a surface area of 10 mm2 and a @actal" coating of titanium nitride. With the model SD-V137 versus TIR, intraoperative electrogram amplitudes were 15.1 +/- 6.1 versus 14.4 +/- 3.9 mV (NS), slew rates 3.45 +/- 1.57 versus 1.94 +/- 1.06 V/s (P < 0.05), pacing thresholds 0.16 +/- 0.05 versus 0.52 +/- 0.15 V (P < 0.01) and impedance measurements 1,136 +/- 175 versus 441 +/- 73 omega (P < 0.0001), respectively. During follow-up, sensing thresholds were the same with both leads. Differences in pulse width thresholds lost its significance on day 28 but resumed on day 360 (SD-V137; 0.08 +/- 0.04 ms; TIR: 0.16 +/- 0.06 ms at 2.5 V; P < 0.01). With an electrode surface of 1.3 mm2, charge per pulse and impedance consistently differed from control, being 0.15 +/- versus 0.66 +/- 0.20 microC (P < 0.001) and 1,344 +/- 376 versus 538 +/- 79 omega respectively, one year after implantation (P < 0.0001). In summary, "fractally" coated small surface electrodes do not compromise sensing; by more than doubling impedance against controls they offer pacing thresholds (mainly in terms of charge) that are significantly lower than with the reference electrode.

Aged↗

Optimizing the geometry of implantable leads for recording the monophasic action potential with fractally coated electrodes.

This study investigates the influence of various lead geometry on intracardial signals like the monophasic action potential (MAP) to optimize the geometry of implantable MAP leads. The experimental results were compared with a field theoretical approach to the origin of MAP from the transmembrane potential (TAP). During the experiments several lead geometries (tip surface: 1.3 to 12 mm2; tip-ring distance: 0.8 mm to 25 cm; ring surface: 1.8 mm2 to 40 mm2) were investigated in endo- and epicardial positions in 12 dogs (17 +/- 9 kg). The electrodes were fixed passively (tines) or actively (screws). MAP was recorded during several interventions and correlated with MAP measured using an Ag-AgCl MAP catheter. The experimental results showed that small tips provided high MAP amplitudes with less pressure. No difference was observed using active and passive fixations. A tip-ring distance smaller than 5 mm with a ring surface smaller than the tip (< 5 mm2) avoided artifacts in the repolarization course. For the theoretical approach the quasistatic, anisotropic bidomain model was calculated in small unity volumes Vi where the TAP phi mi was constant and represented by the current density Ji. Two solutions for electrode positions at and outside the heart were achieved. By superposition of each solution phi ei the summed potential at the electrode position was calculated. The theoretical findings show in good correlation with the experimental results that a larger distance than 10 mm leads to distortions in repolarization course by signals proportional to phi out.

Action Potentials↗

Simultaneous recordings of the monophasic action potential with silver chloride- and Ir-coated electrodes.

Ag/AgCl and Ir-coated electrodes allow the recording of the monophasic action potential (MAP) due to their electrical properties like non-polarisability. This study investigates the correlation of MAP recorded with both types of electrodes. In 20 mongrel dogs (18 +/- 6 kg) an Ag/AgCl and an Ir-coated catheter (Ir) were placed endocardially in the apex of the right ventricle. The effects of isoproterenol and verapamil were investigated during spontaneous rhythm and stimulation simultaneously recorded with both types of electrodes in 10 dogs without AV-node ablation. The correlation at different heart rates were investigated in 10 other dogs with complete AV-block. The morphology and amplitudes of MAP were comparable (AgCl: 15 +/- 7 mV; Ir: 13 +/- 8 mV). Following an i.v. bolus of 2 micrograms/kg isoproterenol the spontaneous rate increased (175 +/- 18 to 245 +/- 25 bpm). During stimulation with 250 ms cycle length the duration shortened (MAPd90: AgCl: 160 +/- 11 to 130 +/- 12 ms; Ir: 154 +/- 18 to 128 +/- 15 ms). The alterations reversed after 20 min. An i.v. bolus of 0.2 mg/kg verapamil decreased the spontaneous rate (167 +/- 11 to 104 +/- 23 bpm) and lengthened the MAPd90 (AgCl: 182 +/- 14 to 220 +/- 13 ms; Ir: 174 +/- 16 to 216 +/- 21 ms) at 300 ms stimulation. The correlation between the MAPd90 of both lead types was r = 0.98 during all measurements. Under the effect of beta-agonist and Ca(2+)-antagonist medication MAP showed a strong correlation recorded with both types of electrodes. Thus, both leads allow the recording of MAP but only the Ir-electrodes with their long-term stability are implantable and allows us to control the effects of drugs with implantable devices.

Action Potentials↗

Intraoperative recordings of monophasic action potentials with chronically implantable pacemaker leads.

Since the development of fractally coated Iridium electrodes recordings of monophasic action potentials are possible. Intraoperative recordings of MAP from 15 pacemaker implantations were done after positioning the chronically implantable pacemaker leads (Biotronik, Berlin, Germany) in the right ventricle by using five screw-in electrodes and ten anchor electrodes. Intraoperative recordings of MAP are possible with all implanted pacemaker leads. The recordings of typical MAP signals were always accompanied with stable electrode positions and good sensing and pacing characteristics.

Action Potentials↗

Intramyocardial electrogram variability in the monitoring of graft rejection after heart transplantation.

The ventricular evoked response is a well-standardized electrophysiological signal that can be used for noninvasive, long-term cardiac transplant monitoring. Rejection-sensitive and infection-specific parameters extracted from intramyocardial electrograms correlate with clinical results. The influences of pacing rate, transition from intrinsic to paced rhythm and positional changes on the diagnostic parameters were studied. Increasing the pacing rate shortened the ventricular evoked response and directly influenced the infection specific parameter. The rejection-sensitive parameter remained stable at pacing rates between 100 and 120 beats/min. Measurements made immediately after the patient assumed a supine position and after switching to paced rhythm showed a decrease in the rejection-sensitive parameter. A change in position from supine to upright did not influence the rejection-sensitive parameter, but higher values were measured after returning to the supine position. In conclusion, noninvasive recordings of the ventricular evoked response for monitoring of cardiac allograft should be done at the same time of day, at the same pacing rate, and with the patient resting for at least 5 minutes before measurements are made.

Adolescent↗

Prediction of the onset of atrial fibrillation after cardiac surgery using the monophasic action potential.

OBJECTIVE: To show that the monophasic action potential (MAP) recorded continuously from human epicardium may be used to predict the imminent onset of atrial fibrillation or flutter (AF) following surgery, thus allowing prophylactic treatment to be started. PATIENTS: 22 patients (14 male, 8 female; mean (SD) age 64 (12) years) undergoing aortic valve replacement. SETTING: Tertiary referral centre. METHODS: Over a mean observation period of 8 (2.7) days (range 4 to 14), nine episodes of AF were seen in six patients. Before AF, specific and significant alterations of the MAP morphology were observed. In seven of nine episodes the MAP shortened (25 (4)% 60 minutes before AF), developed a triangular shape, and the plateau amplitude decreased from 5.3 (1.2) to 2 (0.2) mV. In the two remaining episodes the beat to beat variability of cycle length and MAP duration at 90% repolarisation (MAPd90) increased significantly from 24 (7) ms and 12 (8) ms (24 hours before AF) to 137 (27) ms and 56 (11) ms (30 minutes before AF) respectively. AF was successfully treated by the administration of sotalol in three cases and by a combination of verapamil and digoxin in a further four. Previously observed changes of MAPd90 and MAP morphology regressed after conversion to sinus rhythm. CONCLUSIONS: The continuous and intermediate term recording of the MAP from atrial epicardium appears to be a valid tool for detecting imminent AF after cardiac surgery with a high sensitivity (99%) and specificity (88%). Optimised antiarrhythmic treatment may thus be given selectively for prophylaxis.

Action Potentials↗