Myoglobin to predict myocardial infarction during heart surgery.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Saussine.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In order to assess the efficacy of epsilon aminocaproic acid in reducing bleeding after extracorporeal circulation for aorto-coronary bypass grafting, a double blind study was carried out in 57 patients. The efficiency of epsilon aminocaproic acid was assessed by the fibrinolytic activity as measured by a Von Kaulla test one hour after injection of protamine, by the amount of blood transfusions required and by the measurement of blood losses between the end of the injection of protamine and transfer of the patient to the intensive care unit, and then during the first 24 h following operation. No significant difference (p less than 0.05) between the group of treated patients and the group with placebo could be found concerning the postoperative bleeding, the amount of blood transfusions necessary and the occurrence of fibrinolysis. It was therefore concluded that there was no reason to routinely use epsilon aminocaproic acid after aorto-coronary bypass grafting.
The problem of haemolysis was studied in 244 patients with one or two prosthetic heart valves: 232 of these patients had normal valve function as assessed by clinical examination, radioscopy and echocardiography; 112 patients had a Bjork-Shiley (BS) prosthesis, 25 in the aortic position (BSA), 71 in the mitral position (BSM) and 16 in both aortic and mitral positions (BSA + M). These patients were operated between July 1979 and January 1981. One hundred and twenty other patients had Saint Jude medical (SJM) prostheses; 48 in the aortic position (SJMA), 44 in the mitral position (SJMM) and 28 in both aortic and mitral positions (SJMM + A). These patients were operated between January 1982 and July 1983. Twelve patients (operated between 1977 and 1984) had prosthetic valve dysfunction confirmed by angiography or anatomically (SJM = 7); BS = 5). The plasma haemoglobin concentration (pHb) was used as the reference: it was measured by spectrophotometry with a sensitivity of 0.5 mg/100 ml. There was no significant difference the SJM and BS groups at surgery (BS: 4.62 mg/100 ml; SJM: 4.31 mg/100 ml). In the absence of prosthetic valve dysfunction, haemolysis was significantly greater (p less than 0.001) in the SJM (8.28 mg/100 ml) than in the BS (3.08 mg/100 ml). No statistical correlation was observed with the severity of cardiac disease, the aortic or mitral position of the prostheses or with the number of prostheses. Haemolysis was subclinical in all cases. When haemodynamically significant prosthetic valve dysfunction was present, haemolysis was inconstant in BS prostheses (2 out of 5 cases) despite major haemodynamic disturbances in all cases.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Variations in oncotic pressure-pulmonary artery diastolic pressure gradient and in intrapulmonary shunt were studied in two groups of patients undergoing surgery with extracorporeal circulation for aortocoronary bypass of excision of an aneurysm. The two groups, differed only in terms of the E.C.C. bath (Group A: Ringer Lactate; Group B: DDextran 60,000). The effects of E.C.C. on these parameters were as follows: - decrease in both groups in the gradient (OP-PAP) (respectively P < 0.001 and P < 0.01) but with a more marked decrease in group A than in group B (P < 0.05) with non-negativisation of the gradient in that group; - non-significant variations in Qs/Qt in both groups without any correlation with gradient (OP-PAP). The onset of pulmonary oedema associated with a decrease in gradient (OP-PAP) leads to the suggestion of the use of Dextrans in pathological situations where OP is low or PAP high and all the more so when both of these factors are present.
Explore the source record for details and available documents.
Explore the source record for details and available documents.