Search PubMed⌕ Search

Biomedical subjects

M Sasha John

Publications and source records attributed to M Sasha John.

11 recordsLinked to original sources

Simultaneous latency estimations for distortion product otoacoustic emissions and envelope following responses.

The purpose of this research was to simultaneously estimate processing delays in the cochlea and brainstem using the same acoustic stimuli. Apparent latencies were estimated from ear canal measurements of 2f1-f2 distortion product otoacoustic emissions (DPOAEs), and scalp recordings of the f2-f1 envelope following response (EFR). The stimuli were equal level tone pairs (65 dB SPL) with the upper tone f2 set at either 900 or 1800 Hz to fix the initiation site of the DPOAE and EFR. The frequency of f1 was swept continuously between frequency limits chosen to keep the EFR response between 150 and 170 Hz. The average DPOAE latencies were 9.6 and 6.2 ms for f2 =900 and 1800 Hz, and the corresponding EFR latencies were 12.4 and 8.8 ms. In a control condition, a third (suppressor) tone was added near the DPOAE response frequency to evaluate whether the potential source at fdp was contributing significantly to the measured emission. DPOAE latency is the sum of both inward and outward cochlear delays. The EFR apparent latency is the sum of inward cochlear delay and neural processing delay. Neural delay was estimated as approximately 5.3 ms for both frequencies of stimulation.

Acoustic Stimulation↗

Auditory steady-state responses and word recognition scores in normal-hearing and hearing-impaired adults.

OBJECTIVE: The number of steady-state responses evoked by the independent amplitude and frequency modulation (IAFM) of tones has been related to the ability to discriminate speech sounds as measured by word recognition scores (WRS). In the present study IAFM stimulus parameters were adjusted to resemble the acoustic properties of everyday speech to see how well responses to these speech-modeled stimuli were related to WRS. DESIGN: We separately measured WRS and IAFM responses at a stimulus intensity of 70 dB SPL in three groups of subjects: young normal-hearing, elderly normal-hearing, and elderly hearing-impaired. We used two series of IAFM stimuli, one with modulation frequencies near 40 Hz and the other with modulation frequencies near 80 Hz. The IAFM stimuli, consisting of four carrier frequencies each independently modulated in frequency and amplitude, could evoke up to eight separate responses in one ear. We recorded IAFM responses and WRS measurements in quiet and in the presence of speech-masking noise at 67 dB SPL or 70 dB SPL. We then evaluated the hearing-impaired subjects with and without their hearing aids to see whether an improvement in WRS would be reflected in an increased number of responses to the IAFM stimulus. RESULTS: The correlations between WRS and the number of IAFM responses recognized as significantly different from the background were between 0.70 and 0.81 for the 40 Hz stimuli, between 0.73 and 0.82 for the 80 Hz stimuli, and between 0.76 and 0.85 for the combined assessment of 40 and 80 Hz responses. Response amplitudes at 80 Hz were smaller in the hearing-impaired than in the normal-hearing subjects. Response amplitudes for the 40 Hz stimuli varied with the state of arousal and this effect made it impossible to compare amplitudes across the different groups. Hearing aids increased both the WRS and the number of significant IAFM responses at 40 Hz and 80 Hz. Masking decreased the WRS and the number of significant responses. CONCLUSIONS: IAFM responses are significantly correlated with WRS and may provide an objective tool for examining the brain's ability to process the auditory information needed to perceive speech.

Adult↗

Recording auditory steady-state responses in young infants.

OBJECTIVES: This study examined the auditory steady-state responses evoked by amplitude-modulated (AM), mixed-modulated (MM), exponentially-modulated (AM2), and frequency-modulated (FM) tones in 50 newborn infants (within 3 days of birth) and in 20 older infants (within 3-15 wk of birth). Our hypothesis was that MM and AM2 tonal stimuli would evoke larger responses than either the AM or FM tones, and that this increased size would make the responses more readily detectable. DESIGN: Multiple auditory steady-state responses were recorded to four tonal stimuli presented simultaneously to each ear at 50 dB SPL. The carrier frequencies of the stimuli were 500, 1000, 2000, and 4000 Hz and the modulation rates were between 78 and 95 Hz. Recordings lasting 12 minutes were obtained for each of the three types of modulation: 100% AM, MM (100% AM and 20% FM) and AM2. In six infants, responses to 20% FM were also recorded. RESULTS: In newborn infants, MM and AM2 stimuli produced responses that were on average 15% larger than AM stimuli. For AM, MM, and AM2 stimuli, the percentage of significant responses was 67%, 73%, 76%, respectively. Responses to FM stimuli were clearly evident in newborn infants and were about half the amplitude of the AM responses. Responses recorded in the older infants were 17% larger when evoked by MM and AM2 stimuli, rather than AM stimuli. Responses in the older infants were, on average, 32% larger and showed a higher incidence of significant responses than for infants in the first 3 days of life. For AM, MM, and AM2 stimuli, the percentage of significant responses was 82%, 82%, 84%, respectively. In both newborn and older infants, the overall percentage of significant responses was decreased by the 500 Hz results, which showed lower amplitudes and were less frequently detected than responses evoked by other frequencies. CONCLUSIONS: The responses to MM and AM2 tones were larger than those evoked by AM tones. Using these stimuli will increase the reliability and efficiency of evoked potential audiometry in infancy. Responses at 50 dB SPL are more easily detected at 3-15 wk of age than in the first few days after birth. Comprehensive frequency-specific testing of hearing using steady-state responses will likely be more accurate if postponed until after the immediate neonatal period.

Auditory Perception↗

Avoiding electromagnetic artifacts when recording auditory steady-state responses.

Electromagnetic artifacts can occur when recording multiple auditory steady-state responses evoked by sinusoidally amplitude modulated (SAM) stimuli. High-intensity air-conducted stimuli evoked responses even when hearing was prevented by masking. Additionally, high-intensity bone-conducted stimuli evoked responses that were completely different from those evoked by air-conducted stimuli of similar sensory level. These artifacts were caused by aliasing since they did not occur when recordings used high analog-digital (AD) conversion rates or when high frequencies in the electroencephalographic (EEG) signal were attenuated by steep-slope low-pass filtering. Two possible techniques can displace aliased energy away from the response frequencies: (1) using an AD rate that is not an integer submultiple of the carrier frequencies and (2) using stimuli with frequency spectra that do not alias back to the response frequencies, such as beats or "alternating SAM" tones. Alternating SAM tones evoke responses similar to conventional SAM tones, whereas beats produce significantly smaller responses.

Acoustic Stimulation↗

Concurrent measurement of distortion product otoacoustic emissions and auditory steady state evoked potentials.

Distortion product otoacoustic emissions (DPOAEs) and auditory steady state evoked response potentials (ASSRs) can both be evoked by tone pairs with frequencies f(1) and f(2). The DPOAE is maximal at 2f(1)-f(2) and the ASSR is maximal at f(2)-f(1). Since DPOAE magnitude depends on the ratio f(2)/f(1), but ASSR amplitude depends on the beat frequency f(2)-f(1), compromises are necessary when recording both responses concurrently. Tone pairs with f(2) of 900, 1800 and 3600 Hz were presented simultaneously at either 40 or 50 dB sound pressure level (SPL). The f(1) frequency of each pair was approximately 85 or 180 Hz lower than f(2). Phase measurements were used to calculate apparent latencies at 40 dB SPL. For increasing f(2), DPOAE latencies were 14.5, 9.7 and 6.3 ms for 85 Hz beats, and 11.5, 9.0 and 4.3 ms for 180 Hz beats. ASSR latencies were 22.0, 15.7 and 17.8 ms at 85 Hz, and 17.7, 11.3 and 9.6 ms at 180 Hz. From a model of the mechanical transmission in the cochlea, delays between the basilar membrane and the generator of the ASSR were estimated as 15.4, 12.2 and 15.3 ms at 85 Hz and 8.6, 7.6 and 8.0 ms at 180 Hz.

Acoustic Stimulation↗

Human auditory steady-state responses: the effects of recording technique and state of arousal.

UNLABELLED: There is some controversy in the literature about whether auditory steady-state responses (ASSRs) can be reliably recorded in all subjects and whether these responses consistently decrease in amplitude during drowsiness. In 10 subjects, 40-Hz ASSRs became significantly different from background electroencephalogram activity with a probability of P < 0.01 and an average time of 22 s (range, 2-92 s), provided that the responses were analyzed with time-domain averaging rather than spectral averaging. In a second experiment with 10 subjects, 40-Hz ASSRs recorded between the vertex and posterior neck consistently decreased in amplitude during drowsiness and sleep. Findings that the ASSR may occasionally increase during drowsiness may be explained by postauricular muscle responses recorded from a mastoid reference. These may occur during drowsiness in association with rolling-eye movements. ASSRs recorded between the vertex and posterior neck are not distorted by these reflexes. These findings combine with previous literature on the effects of general anesthetics on the ASSR to confirm that the ASSR is a valid option for monitoring the hypnotic effects of general anesthetics. IMPLICATIONS: Auditory steady-state responses to stimuli presented at rates near 40 Hz can be used to monitor anesthesia. These responses can be quickly and reliably recorded during both sleep and wakefulness, provided that appropriate averaging techniques are used.

Acoustic Stimulation↗

Human auditory steady-state responses.

Steady-state evoked potentials can be recorded from the human scalp in response to auditory stimuli presented at rates between 1 and 200 Hz or by periodic modulations of the amplitude and/or frequency of a continuous tone. Responses can be objectively detected using frequency-based analyses. In waking subjects, the responses are particularly prominent at rates near 40 Hz. Responses evoked by more rapidly presented stimuli are less affected by changes in arousal and can be evoked by multiple simultaneous stimuli without significant loss of amplitude. Response amplitude increases as the depth of modulation or the intensity increases. The phase delay of the response increases as the intensity or the carrier frequency decreases. Auditory steady-state responses are generated throughout the auditory nervous system, with cortical regions contributing more than brainstem generators to responses at lower modulation frequencies. These responses are useful for objectively evaluating auditory thresholds, assessing suprathreshold hearing, and monitoring the state of arousal during anesthesia.

Acoustic Stimulation↗

Auditory steady-state responses to exponential modulation envelopes.

OBJECTIVE: This study examined the steady-state responses evoked by tones modulated with exponential envelopes. The hypothesis was that stimuli with envelopes containing more rapid changes would evoke larger responses. DESIGN: Multiple auditory steady-state responses were recorded simultaneously to eight tonal stimuli, four in each ear. The carrier frequencies of the stimuli ranged from 500 to 6000 Hz and the modulation rates were between 75 and 95 Hz. The modulation envelopes were based on functions using sin' where N was 1, 2, 3, or 4. Setting N to 1 produced the traditional sinusoidal modulation. RESULTS: Exponential envelopes with N greater than 1 produced larger steady-state responses than a sinusoidal envelope. For amplitude-modulation (AM), exponential envelopes increased response amplitudes by 21% at 55 dB pSPL, and by 29% at 35 dB pSPL. The increases were smaller for carrier frequencies of 1500 to 2000 Hz than for lower and higher carrier frequencies. Latencies calculated from phase data increased significantly with increasing N. This was likely caused by the point of maximal envelope-slope shifting later in time as N increased. For frequency modulation (FM), the steady-state responses did not significantly change with changes in the power of the exponential envelopes. CONCLUSIONS: When tones are amplitude-modulated with exponential envelopes based on sin(N), the amplitude and latency of the steady-state response increased significantly with increasing N. Using exponential envelopes with N greater than 1 should considerably shorten the time needed for responses to become significant when using steady-state responses in objective audiometry.

Adult↗

Multiple auditory steady-state responses.

Steady-state responses are evoked potentials that maintain a stable frequency content over time. In the frequency domain, responses to rapidly presented stimuli show a spectrum with peaks at the rate of stimulation and its harmonics. Auditory steady-state responses can be reliably evoked by tones that have been amplitude-modulated at rates between 75 and 110 Hz. These responses show great promise for objective audiometry, because they can be readily recorded in infants and are unaffected by sleep. Responses to multiple tones presented simultaneously can be independently assessed if each tone is modulated at a different modulation frequency. This ability makes it possible to estimate thresholds at several audiometric frequencies in both ears at the same time. Because amplitude-modulated tones are not significantly distorted by free-field speakers or microphones, they can also be used to evaluate the performance of hearing aids. Responses to amplitude and frequency modulation may also become helpful in assessing suprathreshold auditory processes, such as those necessary for speech perception.

Age Factors↗

Estimating the audiogram using multiple auditory steady-state responses.

Multiple auditory steady-state responses were evoked by eight tonal stimuli (four per ear), with each stimulus simultaneously modulated in both amplitude and frequency. The modulation frequencies varied from 80 to 95 Hz and the carrier frequencies were 500, 1000, 2000, and 4000 Hz. For air conduction, the differences between physiologic thresholds for these mixed-modulation (MM) stimuli and behavioral thresholds for pure tones in 31 adult subjects with a sensorineural hearing impairment and 14 adult subjects with normal hearing were 14+/-11, 5+/-9, 5+/-9, and 9+/-10 dB (correlation coefficients .85, .94, .95, and .95) for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. Similar results were obtained in subjects with simulated conductive hearing losses. Responses to stimuli presented through a forehead bone conductor showed physiologic-behavioral threshold differences of 22+/-8, 14+/-5, 5+/-8, and 5+/-10 dB for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. These responses were attenuated by white noise presented concurrently through the bone conductor.

Adult↗

Advantages and caveats when recording steady-state responses to multiple simultaneous stimuli.

This article considers the efficiency of evoked potential audiometry using steady-state responses evoked by multiple simultaneous stimuli with carrier frequencies at 500, 1000, 2000, and 4000 Hz. The general principles of signal-to-noise enhancement through averaging provide a basis for determining the time required to estimate thresholds. The advantage of the multiple-stimulus technique over a single-stimulus approach is less than the ratio of the number of stimuli presented. When testing two ears simultaneously, the advantage is typically that the multiple-stimulus technique is two to three times faster. One factor that increases the time of the multiple-response recording is the relatively small size of responses at 500 and 4000 Hz. Increasing the intensities of the 500- and 4000-Hz stimuli by 10 or 20 dB can enhance their responses without significantly changing the other responses. Using multiple simultaneous stimuli causes small changes in the responses compared with when the responses are evoked by single stimuli. The clearest of these interactions is the attenuation of the responses to low-frequency stimuli in the presence of higher-frequency stimuli. Although these interactions are interesting physiologically, their small size means that they do not lessen the advantages of the multiple-stimulus approach.

Audiometry, Pure-Tone↗