Thrombolytic therapy in acute ischemic stroke.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M S Firstenberg.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Radiofrequency current catheter ablation was used successfully to create complete atrioventricular (AV) block in 60 of 61 patients (98%) with drug refractory supraventricular tachyarrhythmias. The remaining patient developed Mobitz I AV block and is clinically improved (clinical efficacy 100%). In 54 patients (89%), complete AV block was achieved using a right-sided approach. Patients aged > 60 years needed significantly fewer right-sided radiofrequency applications to produce complete AV block (5.3 +/- 5.3 vs 11.1 +/- 10.0; p = 0.009). In 6 of 7 patients with unsuccessful right-sided ablation, a left ventricular approach was used. In each case, 1 to 4 additional radiofrequency applications produced complete AV block. Patients with unsuccessful right-sided ablation were generally younger than those with successful ablation (50 +/- 16 vs 64 +/- 11; p = 0.007). It is concluded that catheter ablation using radiofrequency current is an extremely effective means of producing complete AV block. Older patients appear to be more susceptible to right-sided radiofrequency approaches. Left ventricular ablation easily produces complete AV block in patients refractory to right-sided attempts.
The cause of death and clinical characteristics of 26 patients that died after implantable cardioverter defibrillator placement were reviewed and compared to the 145 patients still living after a mean follow-up of 17 months. Operative mortality was 4% (7/171) and resulted from postoperative ventricular arrhythmias (four patients), heart failure (two patients), and respiratory failure (one patient). Operative mortality was significantly higher (1.7% vs 9.6%, P less than 0.05) following concomitant surgical procedures. Total late mortality was 11% (18/171). Thirteen deaths (75%) occurred in-hospital from progressive deterioration of left ventricular function (nine patients), arrhythmia (two patients), and noncardiac causes (two patients). Outpatient mortality was 3.5% (6/171) and resulted from presumed sudden cardiac death in five of six patients; two of the five had devices that were inactive, one had high defibrillation thresholds, and two had suspected bradyarrhythmic deaths. One postoperative death and one late in-hospital death were also considered sudden cardiac deaths for a total of seven patients with defibrillation system failures. By multivariant analysis, preoperative clinical characteristics associated with a worse prognosis following defibrillator implantation were identified: presentation as ventricular tachycardia (P less than 0.02), induction of sustained monomorphic ventricular tachycardia (P less than 0.05), poor left ventricular performance (P less than 0.01), poor functional status (P less than 0.001), and the use of diuretics (P less than 0.01). Frequent device discharges (P less than 0.001) and concomitant antitachycardia pacing systems (P less than 0.001) were markers for greater arrhythmia recurrence and were potent predictors of a worse prognosis and particularly sudden death.