Search PubMed⌕ Search

Biomedical subjects

M Rovaris

Publications and source records attributed to M Rovaris.

At least 91 records · Page 5Linked to original sources

Multiple sclerosis: interobserver agreement in reporting active lesions on serial brain MRI using conventional spin echo, fast spin echo, fast fluid-attenuated inversion recovery and post-contrast T1-weighted images.

Previous studies have addressed the question of the precision in assessing multiple sclerosis (MS) activity by counting enhancing lesions on gadolinium enhanced brain magnetic resonance imaging (MRI). However, counting the active lesions on serial unenhanced MRI obtained by various pulse sequences has not been yet considered. We compared the interobserver levels of agreement in reporting active MS lesions on serial enhanced and unenhanced MRI to assess whether the use of various unenhanced techniques may change the degree of interobserver measurement reproducibility. Dual-echo conventional spin echo (CSE), dual-echo fast spin echo (FSE), fast fluid-attenuated inversion recovery (FLAIR) and Gd-enhanced T1-weighted brain MRI were obtained from five MS patients at baseline and monthly for 2 months. Six experienced observers independently identified and counted active MS lesions on the two follow-up MRI scans. Active lesions were considered to be all the enhancing lesions and any new or enlarging lesion on enhanced and unenhanced scans. Interobserver levels of agreement were calculated by weighted kappa values. Very good agreement was reached only for counting total and new Gd-enhancing lesions. Good agreement was achieved for counting new lesions on the three unenhanced techniques, whereas the agreement for counting enlarging lesions was poor with all the MRI techniques. The level of agreement was significantly heterogeneous for various MRI techniques but not for various lesion sites. These results confirm that counting enhancing lesions is the most reliable method for assessing MS activity, but the use of any of the available unenhanced MRI techniques did not result in different levels of interobserver agreement when reporting new and enlarging MS lesions on serial scans.

Brain↗

A longitudinal study comparing the sensitivity of CSE and RARE sequences in detecting new multiple sclerosis lesions.

In this longitudinal study, we evaluated the sensitivities of dual-echo, conventional spin-echo (CSE), and rapid-acquisition relaxation-enhanced (RARE) scans for detecting the appearance of new lesions in multiple sclerosis (MS). Dual echo, CSE, and RARE scans were obtained on four occasions each separated by 28 days from five patients with relapsing-remitting MS using a 1.5-Tesla machine. A total of 44 new lesions were detected by the two sequences. Thirty-five lesions were seen on both sequences, three only on CSE and six only on FSE. This study indicates that CSE may be substituted by RARE when monitoring short-term disease activity in MS.

Brain↗

Correlation between enhancing lesion number and volume on standard and triple dose gadolinium-enhanced brain MRI scans from patients with multiple sclerosis.

We investigated the correlations between numbers and volumes of multiple sclerosis (MS) lesions enhancing on standard dose (SD) and triple dose (TD) gadolinium (Gd)-enhanced brain magnetic resonance imaging (MRI) scans, to clarify whether the measurement of enhancing lesion volumes or the use of TD MRI give additional information which can not be obtained by counting enhancing lesions on SD scans. SD and TD Gd-enhanced brain MRI scans were obtained every month for three months from 40 MS patients. The numbers of total and new enhancing lesions were counted, and the total volumes of enhancing lesions were measured from each of the four scans obtained with the two techniques. Univariate correlations between enhancing lesion numbers and volumes were assessed. The numbers of total and new enhancing lesions seen either on SD or TD scans were significantly correlated (r = 0.91 and 0.93, respectively). The numbers and volumes of total enhancing lesions were significantly correlated on both SD (r = 0.90), and TD (r = 0.89) scans. Moderate correlations were found between the total number of enhancing lesions on SD scans and the average difference between TD and SD scans for total enhancing lesion number (r = 0.66), and between the number of new enhancing lesions on SD scans and the average difference between TD and SD scans for new enhancing lesion number (r = 0.50). Our findings indicate that, both on SD and TD MRI, the counts and the volumes of total and new enhancing lesions are highly correlated, and that lesion counting may suffice to monitor MS activity. On the contrary, this study confirms the usefulness of TD MRI for a more complete assessment of the acute changes occurring in MS patients.

Brain↗

Lesion load quantification on fast-FLAIR, rapid acquisition relaxation-enhanced, and gradient spin echo brain MRI scans from multiple sclerosis patients.

Previous studies have addressed the issue of the usefullness of fast fluid-attenuated (fast-FLAIR), rapid acquisition relaxation-enhanced (RARE), and gradient spin echo (GRASE) sequences in small groups of patients with multiple sclerosis (MS). The aim of this study was to assess and compare the lesion volumes and the intra-rater reproducibility of such measurements using fast-FLAIR, dual echo RARE, and dual echo GRASE brain scans from a large sample of MS patients. Using a 1.5 Tesla scanner, fast-FLAIR, dual echo RARE, and dual echo GRASE scans (24 axial, 5-mm thick contiguous interleaved slices) of the brain were obtained from 50 MS patients. Total lesion loads (TLL) were assessed twice using a semi-automated local thresholding segmentation technique by the same rater from the scans obtained with the three techniques. Mean TLL were 20.3 mL for fast-FLAIR, 16.6 mL for RARE, and 17.6 mL for GRASE sequences. Mean TLL detected by the three techniques were significantly heterogeneous (p < 0.001); at post-hoc analysis, the mean lesion volume detected on fast-FLAIR images was significantly higher than that on both RARE and GRASE images (p < 0.001) and the mean TLL on GRASE scans was significantly higher than that on RARE scans (p = 0.001). The mean values of intra-observer coefficient of variation for TLL measurements were similar for the three techniques (2.69% for fast-FLAIR, 2.33% for RARE, and 2.65% for GRASE). Our results confirm that fast-FLAIR sequences detect higher lesion volumes than those detected by other magnetic resonance imaging (MRI) sequences with shorter acquisition times. However, the reproducibility of TLL measurements is comparable among fast-FLAIR, RARE, and GRASE. This suggests that when assessing MS disease burden with MRI, the choice of the pulse sequence to be used should be dictated by the clinical setting.

Adult↗

Method for intracellular magnetic labeling of human mononuclear cells using approved iron contrast agents.

A method for intracellular iron labeling of human mononuclear cells (lymphocytes and monocytes) for magnetic resonance imaging (MRI) using simple incubation of cells with approved MRI iron contrast agents is presented. Labeled cells can be detected by MRI in vitro, and this suggests the possibility that the technique could become a marker for in vivo lymphocyte and monocyte trafficking studies in acute inflammatory lesions such as those in Multiple Sclerosis.

Cell Survival↗

Review neuroimaging in amyotrophic lateral sclerosis.

Amyotrophic lateral sclerosis (ALS) is a chronic degenerative disorder of unknown etiology affecting the motor system. Conventional and non-conventional neuroimaging techniques can provide essential help both to increase the confidence in ALS diagnosis and to assess the disease evolution. Signal abnormalities at the level of the motor cortex and the corticospinal tract on conventional T2-weighted magnetic resonance (MR) images are a potentially useful marker of ALS pathology. However, the prognostic value of these conventional MR abnormalities is still hampered by their low pathological specificity. Non-conventional MR techniques with a higher pathological specificity, such as MR spectroscopy, magnetization transfer imaging and diffusion-weighted imaging, seem to have some potential not only for ALS diagnosis, but also for monitoring disease evolution either naturally or when modified by experimental treatments.

Amyotrophic Lateral Sclerosis↗

Central nervous system sarcoidosis--diagnosis and management.

A series of 68 patients with neurosarcoidosis is reported, with particular emphasis on clinical aspects, diagnosis and treatment. A classification system based on clinical diagnostic probability is proposed, consisting of probable and definite disease, the latter being dependent on finding sarcoid granulomas on nervous system histology, which was obtained in 12 patients (18%). The role of investigations, including magnetic resonance imaging (MRI), chest radiography, Kveim skin test, Gallium 67 isotope scanning and cerebrospinal fluid (CSF) studies, is considered. Sixty-two percent of patients presented with nervous system disease, most commonly affecting the optic nerve and chiasm. Other common presentations included cranial nerve palsies, spinal cord and brainstem manifestations. Investigations yielding most diagnostic information included the Kveim test (41/48, 85% positive), raised CSF protein and/or cells (50/62, 81%) and gallium 67 scan (14/31, 45%). Eleven out of 29 patients (38%) patients showed meningeal enhancement on MRI scanning and 43% of scans demonstrated multiple white-matter lesions. Mean follow-up for the group was 4.6 years. Forty-seven patients were seen for > 18 months, and over half of these patients progressed despite corticosteroid and other immunosuppressive therapies. The benefit of a large patient database prospectively studied, with extended follow-up is discussed in order to learn more about prognosis and advance therapy in neurosarcoidosis.

Adrenal Cortex Hormones↗

Magnetic resonance techniques to monitor disease evolution and treatment trial outcomes in multiple sclerosis.

Although the correlations between magnetic resonance findings and long-term disease evolution range from poor to moderate, conventional precontrast and postcontrast magnetic resonance imaging provides sensitive and reliable measures to monitor multiple sclerosis activity over time. New pulse sequences with shorter acquisition times can be cost effective and reduce patients' discomfort. The application of other techniques that give more accurate estimates of disease burden and have higher pathological specificity might improve our understanding of multiple sclerosis evolution and provide new outcomes for monitoring clinical trials. Work is still needed to obtain optimal imaging of the spinal cord for multiple sclerosis diagnosis and monitoring.

Clinical Trials as Topic↗

Interferon beta treatment for multiple sclerosis has a graduated effect on MRI enhancing lesions according to their size and pathology.

OBJECTIVE: The ability of recombinant human interferon beta-1a (rh-IFN beta-1a) to suppress multiple sclerosis activity, evaluated from MRI, was assessed across a range of lesions enhancing at different gadolinium-DTPA (Gd) doses and with different sizes. METHODS: Every 4 weeks, standard dose (Sd; 0.1 mmol/kg Gd) and triple dose (Td; 0.3 mmol/kgGd) MRI were obtained from 18 patients with relapsing-remitting multiple sclerosis for 3 months before and 4 months after starting treatment with 44 microgram rh-IFN beta-1a subcutaneously, once a week. RESULTS: The total numbers of enhancing lesions were 145 and 126 on Sd scans and 278 and 192 on the Td scans obtained before and after treatment. The introduction of treatment decreased, on average, the rate of appearance of new enhancing lesions seen on Sd and Td scans by 37% (p<0.001). Treatment effects on new enhancing lesions seen on Td scans was, on average, 28% higher than on those seen on Sd scans. The distribution of lesion sizes on Td scans changed significantly during the treatment period (p=0.05), due to a marked decrease in the number of small lesions. CONCLUSIONS: The effect of 44 microgram rh-IFN beta-1a in reducing multiple sclerosis disease activity, as monitored by Gd enhanced MRI, is not homogeneous, but graduated according to the pathological characteristics and size of the lesions.

Adult↗

Correlation between MRI and short-term clinical activity in multiple sclerosis: comparison between standard- and triple-dose Gd-enhanced MRI.

We assessed the relative sensitivities of standard (SD)- and triple-dose (TD) gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) for detecting enhancing lesions in different phases of multiple sclerosis (MS) disease activity. Ten MS patients were studied with monthly brain MRI scans for a 3-month follow-up (i.e., 4 scans were obtained for each patient with both SD and TD). A total of 11 relapses were recorded and treated with short-term high-dose steroid therapy. Enhancing lesion numbers and volumes were significantly higher for TD vs. SD scans (p < 0.0001). For both Gd doses, the numbers and volumes of lesions were higher during clinical relapses; the differences were statistically significant when comparing the results for scans obtained during and after a relapse. The gain in sensitivity of TD vs. SD scans for enhancing lesion detection was lower during relapses, whilst it was maximum after relapses, although these differences did not reach statistical significance. Our data confirm the potential role of TD MRI for monitoring MS activity, since, with its higher sensitivity, it may detect more subtle blood-brain barrier (BBB) damage. They also suggest that the degree of BBB damage in individual lesions changes during different phases of disease activity.

Adult↗

Reproducibility of brain MRI lesion volume measurements in multiple sclerosis using a local thresholding technique: effects of formal operator training.

The assessment of lesion load (LL) on brain magnetic resonance imaging (MRI) scans from patients with multiple sclerosis (MS) is widely used to monitor disease evolution, natural or modified by treatments. In this study, we evaluated the effect of formal operator training on the intra- and inter-observer reproducibility of LL measurements obtained by several operators in a setting similar to that of clinical trials. Proton-density (PD)-weighted, unenhanced and enhanced T1-weighted brain MRI scans were obtained from 10 MS patients. Five naive technicians assessed LL on these images, using a semiautomated local thresholding technique for lesion segmentation and marked hardcopies as a reference. Measurements were performed twice before and twice after a 20-hour operator training. Mean intra-observer measurement coefficient of variations (COV) before and after the training were 3.1 and 1.6% for PD-weighted LL, 4.3 and 1.8% for unenhanced T1-weighted LL (p < 0. 001), 4.9 and 2.0% for enhanced T1-weighted LL (p = 0.002). Mean inter-observer COV were significantly reduced after training (from 10.0 to 5.6% for PD-weighted, from 11.0 to 7.3% for unenhanced T1-weighted and from 16.0 to 6.8% for enhanced T1-weighted LL). Our data indicate that LL assessment on serial MRI scans from MS patients performed by technicians, using a local thresholding technique for lesion segmentation, is characterized by low measurement variability which may be significantly improved by a short and cost-effective training.

Brain↗

Relevance of hypointense lesions on fast fluid-attenuated inversion recovery MR images as a marker of disease severity in cases of multiple sclerosis.

BACKGROUND AND PURPOSE: Hypointense lesions can be visible on fast fluid-attenuated inversion recovery (FLAIR) MR images of the brain of patients with multiple sclerosis (MS), and they may be produced by severely damaged white matter. To test the role of these lesions as an MR marker of MS severity, we assessed their relationship with clinical findings and other MR measures. METHODS: Using a 1.5-T scanner, dual-echo rapid acquisition with relaxation enhancement, fast FLAIR, and T1-weighted MR images (24 axial, 5-mm-thick contiguous interleaved sections) were obtained from 50 patients (32 with relapsing-remitting and 18 with secondary progressive MS). RESULTS: Hypointense lesions were visible on the fast FLAIR images of 19 patients (mean number of lesions, 7.8; range 1-22); their median load was 1.4 mL (range, 0.05-12.6 mL). The median lesion load was significantly higher in patients with secondary progressive MS than in those with relapsing-remitting MS on the T1-weighted images. Both the number and the load of hypointense lesions shown by fast FLAIR imaging were significantly higher in patients with secondary progressive MS. Significant correlations were found between Expanded Disability Status Scale scores and MR lesion load. A multivariate analysis showed that only the presence of hypointense lesions on fast FLAIR images significantly separated cases of relapsing-remitting MS from cases of secondary progressive MS (relative risk, 7.1; 95% confidence interval, 2.0-25.9). CONCLUSION: The presence of hypointense lesions on fast FLAIR images was a strong predictor of disease severity in cases of MS, although the low sensitivity of this approach might limit its use for the assessment of MS evolution.

Adult↗

Correlations between magnetization transfer metrics and other magnetic resonance abnormalities in multiple sclerosis.

Magnetization transfer imaging (MTI) is a magnetic resonance imaging (MRI) technique that is now used in multiple sclerosis (MS) studies, and is thought to have a higher pathological specificity than conventional T2-weighted imaging. This review outlines the correlations between magnetization transfer (MT) metrics and other MRI abnormalities in the study of individual MS lesions and in the assessment of MS disease burden. MTI studies of individual MS lesions confirm the pathological heterogeneity of T2-weighted MRI abnormalities and the potential role of unenhanced T1-weighted hypointensities as specific markers of localized severe white matter disruption. Correlative cross-sectional and longitudinal studies using MTI and gadolinium (Gd)-enhanced MRI reveal that MTI findings may vary in lesions with different patterns of enhancement, and that MTI abnormalities are closely related to the onset and recovery of blood-brain barrier disruption in new MS plaques. MTI lesion load (LL) is highly correlated with T2-weighted MRI LL, but it has a limited reliability as a measure of MS disease burden. On the contrary, measures obtained from MTI scans using whole-brain histogram analysis are highly correlated with the extent of MS abnormalities on conventional MRI scans, and predict patients' clinical disability well, since they are sensitive to the amounts of both macro- and microscopic MS disease burden in the whole brain and in specific regions. The correlations between MTI metrics and conventional MRI findings suggest that: (a) MTI is sensitive to different stages of lesion pathology and pathological evolution in MS patients; and (b) MT histogram analysis can provide a more global assessment of MS disease burden, since it encompasses both macro- and microscopic MS pathology.

Brain↗

A longitudinal brain MRI study comparing the sensitivities of the conventional and a newer approach for detecting active lesions in multiple sclerosis.

Monthly dual-echo spin-echo (SE) and enhanced magnetic resonance imaging (MRI) after the injection of a standard dose (SD) of gadolinium (Gd) is the conventional approach to monitor short-term disease activity in multiple sclerosis (MS). In this study, the sensitivity of this approach in detecting active lesions in MS was compared with that of monthly fast fluid attenuated inversion recovery (FLAIR) scans associated with enhanced MRI after the injection of a triple dose (TD) of Gd. Thirteen patients with relapsing-remitting MS entered the study. Monthly MRI scans were obtained on four occasions in two separate sessions (interval between 12 and 24 h). In one session, dual-echo conventional SE and SD Tl-weighted scans were obtained; in the other, fast-FLAIR and TD Tl-weighted scans. The order of the two sessions was randomized. Three observers counted the number of active lesions detected by each of the two approaches. One hundred and four active lesions were detected by the conventional approach and 199 by the newer approach (average increase per patient = 75%, range = 0-325%). The mean number of active lesions per month per patient was 2.0 for the conventional approach and 3.8 for the new approach (P = 0.004). Scans with active lesions were 34/52 (65%) with the conventional approach and 37/52 (71%) with the new approach. Our data indicate that the combined use of monthly fast-FLAIR and TD enhanced Tl-weighted scans increases the number of active lesions detected on serial MRI scans from patients with MS.

Adult↗

The effect of repositioning on brain MRI lesion load assessment in multiple sclerosis: reliability of subjective quality criteria.

The aim of this study was to assess the variability of lesion load measurements for repeated brain magnetic resonance imaging (MRI) scans judged to have either poor or good repositioning quality on the basis of subjective criteria used for clinical trials in multiple sclerosis (MS). Scan-rescan variability was also compared with the intra-observer variability assessed from three repeated volume measurements of the same scan. Nine patients with MS were studied; each of them underwent the scan-rescan procedure on the same day. Five scans were considered to have poor and four scans to have good repositioning. Between these two groups there were no differences in either the mean lesion loads or the measurement variance. For the whole group of patients, the intra-observer variability of repeated measurements gave a significantly lower coefficient of variation (COV = 4.9%) than the variability owing to repositioning (COV = 8.9%, P < 0.01, F test). Our results confirm that the effect of repositioning on brain MRI lesion load assessment is stronger than that owing to the intra-observer variability for repeated measurements and indicate that the simple visual judgment about the scan repositioning quality seems unable to predict the scan-rescan reproducibility.

Adult↗

How does brain MRI lesion volume change on serial scans in patients with multiple sclerosis?

Although lesion load changes on conventional T2-weighted brain magnetic resonance imaging (MRI) scans from patients with multiple sclerosis (MS) are used to monitor the effect of treatment, there is no clear definition of how lesion load changes over years according to the lesion load present at a baseline evaluation. In the present study, we evaluated the relationship between lesion load changes over time and lesion load at a baseline evaluation in a group of untreated patients with MS. We scanned nineteen patients on two separate occasions with a mean interval 16.4 months between the two examinations. In each scanning session, a scan with forty contiguous 3-mm-thick axial slices was acquired. We assessed MRI lesion loads using a semi-automated local thresholding technique. Both a linear (p < 0.0001) and a quadratic component (p = 0.0008) of the baseline volume were significant in describing the follow-up volume. The equation to model this finding was as follows: Vf = beta0 Vb + beta1 (Vb)2, where Vf is the lesion volume at follow-up, Vb is the lesion volume at baseline, beta0 = 0.834 (SE = 0.098), and beta1 = 0.014 (SE = 0.003) (mL)(-1). Our data indicate that lesion volume changes detectable on serial brain MRI studies from patients with MS are dependent on the extent of lesion burden present on the baseline MRI scans. This finding has to be considered when planning phase III trials.

Adult↗

Brain MRI lesion volume measurement reproducibility is not dependent on the disease burden in patients with multiple sclerosis.

We evaluated the potential effect of the lesion burden on the reproducibility of repeated lesion volume (LV) measurements from brain magnetic resonance imaging (MRI) scans of patients with multiple sclerosis (MS). Dual-echo, conventional spin echo brain MRI scans were obtained from 107 patients with MS. On proton density-weighted images, LV was assessed three times by the same raters, using a semi-automated, local thresholding technique for lesion segmentation. Mean LV (MLV) was 16.1 mL (range = 0.7-57.3 mL). The mean intra-observer coefficient of variation (COV) for the three measurement replicates was 2.6% (range = 0.2-7.2%). The intra-observer measurement variance (Var) increased with MLV and the fitted model was Var = 0.00187 MLV1.84. This indicates that LV measurements can be considered as measures whose variances are proportional to the square of their mean values, i.e., these measures have constant COV. Using a semi-automated, local thresholding segmentation technique, the reproducibility of LV measurements from brain MRI scans of patients with MS is not significantly influenced by varying lesion burdens.

Analysis of Variance↗

A multi-centre longitudinal study comparing the sensitivity of monthly MRI after standard and triple dose gadolinium-DTPA for monitoring disease activity in multiple sclerosis. Implications for phase II clinical trials.

In this study we assessed the safety, efficacy and cost-effectiveness of the use of triple dose gadolinium-DTPA (Gd) in serial monthly brain MRI of patients with multiple sclerosis, such as could be selected for clinical trials. The number of enhancing lesions, the number of new enhancing lesions and the number of active scans were used to evaluate the sensitivity of the contrast-enhanced MRI to disease activity. The dose of Gd, and the effect of introducing a delay between the contrast injection and the scan were both appraised. Every 4 weeks for 3 months, and in two separate sessions, scans were obtained from 40 patients with relapsing-remitting or secondary progressive multiple sclerosis, 5 min (early) and 20 min (delayed) after a standard dose (0.1 mmol/kg) or triple dose (0.3 mmol/kg) Gd injection. There were 435 enhancing lesions (242 of which were new) on the early standard dose scans, 479 (263 new) on the delayed standard dose, 772 (365 new) on the early triple dose and 827 (404 new) on the delayed triple dose. There were 109 scans revealing active disease on the early standard dose scans, 112 on the delayed standard dose, 119 on the early triple dose and 120 on the delayed triple dose. Statistical simulations indicated that the sample sizes needed for both cross-over and parallel-group trials with similar powers are lower if serial monthly triple dose MRI is used. No side-effects were reported and no significant changes in blood test parameters were found throughout the study. This study shows that the serial use of triple dose Gd is safe, and that it increases the sensitivity of serial monthly enhanced MRI in detecting multiple sclerosis activity significantly. Its use should enable preliminary trials of experimental therapies for multiple sclerosis to be conducted in small patient populations, over a short period of time.

Adult↗