Search PubMed⌕ Search

Biomedical subjects

M Rink

Publications and source records attributed to M Rink.

11 recordsLinked to original sources

A scintillation proximity assay for the Raf/MEK/ERK kinase cascade: high-throughput screening and identification of selective enzyme inhibitors.

We have developed a quantitative scintillation proximity assay (SPA) that reproduces the Raf/MEK/ERK signal transduction pathway. The components of this assay include human cRaf1, MEK1, and ERK2 and a biotinylated peptide substrate for ERK2. cRaf1 was expressed as a his-tagged protein in insect cells in an active form. MEK1 and ERK2 were expressed in Escherichia coli as glutathione S-transferase (GST)-fusion proteins in their inactive forms. ERK2 was removed from the GST portion of the fusion protein by cleavage with thrombin protease. When the purified components are incubated together, cRaf-1 phosphorylates and activates MEK1, MEK1 phosphorylates and activates ERK2, and ERK2 phosphorylates the peptide, biotin-AAATGPLSPGPFA. Phosphorylation of the peptide using [gamma-33P]ATP is detected following binding to streptavidin-coated SPA beads. The assay detects inhibitors of cRaf1, MEK1, or ERK2, and has been used to screen large numbers of compounds. The specific target of inhibition was subsequently identified with secondary assays described herein.

Amino Acid Sequence↗

[Optimizing primary total hip replacement--a technique to effect saving of manpower].

PURPOSE: Development of a standardized surgical technique for total hip replacement thereby saving manpower (one assistant) by using a retractor system. METHOD: Total hip replacement is performed with the patient in a true lateral position on a tunnel cushion. By means of a direct lateral approach the pelvitrochanteric muscles are partially detached using an omega-shaped cut. The Bookwalter retractor is fixed dorsally on the operating table. The ring is centered keeping the greater trochanter in the middle. The Hohmann retractors are fixed to the ring to sufficiently expose the acetabulum. To insert the femoral stem the ring needs to be opened dorsally and the patient's leg is bent 90 degrees in the hip and the knee over the tunnel cushion. The muscles inserting at the greater trochanter are retracted by a separate Hohmann retractor with weight. In a case control study with matched pairs the patients treated with this technique were compared with those treated in supine position with the transgluteal approach. The number of assistants required and the operating time were assessed. RESULTS: All the hip replacements with the patient in side position were performed with one assistant, in supine position with two assistants. The operating time did not differ significantly (supine position 110 min/side position 112 min). The complication rate in both groups was comparable (one secondary wound healing, one transient ischalgia). CONCLUSION: The process of total hip replacement can be optimized. The described technique allows to spare one surgical assistant without prolonging the operating time.

Appointments and Schedules↗