Search PubMed⌕ Search

Biomedical subjects

M Reiser

Publications and source records attributed to M Reiser.

At least 37 records · Page 2Linked to original sources

Quantitative molecular monitoring of residual tumor cells in chronic lymphocytic leukemia.

New therapeutic approaches for the treatment of B-cell chronic lymphocytic leukemia (B-CLL) can induce remarkable responses. Molecular remissions have been observed occasionally after high-dose chemotherapy. Thus, new improved techniques to monitor residual tumor cells on a molecular basis in CLL are warranted. For this purpose, a real-time quantitative allele-specific oligonucleotide polymerase chain reaction (ASO-PCR) for patients with B-CLL was designed. In the present study, the PCR assay was standardized with identical cycling parameters as well as primer, probe, and MgCl(2) concentration for each patient. Ten patients were monitored with DNA samples obtained at 52 time points (median: 5.2 per patient). The median follow-up per patient was 11.4 months. Nine of ten patients had PCR-detectable residual tumor cells in the peripheral blood after therapy. One patient became PCR negative with a combination of fludarabine and rituximab after the end of treatment. The MRD levels in patients with detectable disease ranged from 0.002% to 10.1% after therapy. We conclude that real-time quantitative ASO-PCR can be utilized for quantitative molecular monitoring of minimal residual disease (MRD) in B-CLL patients in complete remission (CR), that new effective treatment approaches such as combined chemo/immunotherapy can render CLL patients PCR negative, and that different MRD levels in PCR-positive patients were observed warranting further investigation into possible correlation with clinical outcome.

Aged↗

European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation.

Our purpose was to report about technical success, problems and solutions, as experienced in a first multicentre study on MR-guided localisation or vacuum biopsy of breast lesions. The study was carried out at four European sites using a dedicated prototype breast biopsy device. Experiences with 49 scheduled localisation procedures and 188 vacuum biopsies are reported. Apart from 35 dropped indications, one localisation procedure and 9 vacuum biopsies were not possible (3 times space problems due to obesity, 2 times too strong compression, 3 times impaired access from medially, 2 times impaired access due to a metal bar). Problems due to too strong compression were recognised by repeat MR without compression. During the procedure problems leading to an uncertain result occurred in eight vacuum biopsies, two related to the procedure: one limited access, and one strong post-biopsy enhancement. Improvements after phase-I study concerned removal of the metal bar, development of an improved medial access, of a profile imitating the biopsy gun, optimisation of compression plates and improved software support. The partners agreed that the improvements answered all important technical problems.

Biopsy, Needle↗

Clinical evaluation of further-developed MRCP sequences in comparison with standard MRCP sequences.

The purpose of this study was the comparison of technically improved single-shot magnetic resonance cholangiopancreatography (MRCP) sequences with standard single-shot rapid acquisition with relaxation enhancement (RARE) and half-Fourier acquired single-shot turbo spin-echo (HASTE) sequences in evaluating the normal and abnormal biliary duct system. The bile duct system of 45 patients was prospectively investigated on a 1.5-T MRI system. The investigation was performed with RARE and HASTE MR cholangiography sequences with standard and high spatial resolutions, and with a delayed-echo half-Fourier RARE (HASTE) sequence. Findings of the improved MRCP sequences were compared with the standard MRCP sequences. The level of confidence in assessing the diagnosis was divided into five groups. The Wilcoxon signed-rank test at a level of p<0.05 was applied. In 15 patients no pathology was found. The MRCP showed stenoses of the bile duct system in 10 patients and choledocholithiasis and cholecystolithiasis in 16 patients. In 12 patients a dilatation of the bile duct system was found. Comparison of the low- and high spatial resolution sequences and the short and long TE times of the half-Fourier RARE (HASTE) sequence revealed no statistically significant differences regarding accuracy of the examination. The diagnostic confidence level in assessing normal or pathological findings for the high-resolution RARE and half-Fourier RARE (HASTE) was significantly better than for the standard sequences. For the delayed-echo half-Fourier RARE (HASTE) sequence no statistically significant difference was seen. The high-resolution RARE and half-Fourier RARE (HASTE) sequences had a higher confidence level, but there was no significant difference in diagnosis in terms of detection and assessment of pathological changes in the biliary duct system compared with standard sequences.

Adult↗

Granulopoiesis-stimulating factors in the prevention for adverse effects in the therapeutic treatment of malignant lymphoma.

BACKGROUND: Granulopoiesis-stimulating factors (G-CSF and GM-CSF) are being used to prevent febrile neutropenia and infections in the treatment of patients with malignant lymphoma. The question whether G-CSF and GM-CSF improve dose-intensity, tumour response and overall survival in this patient population has not been answered yet. Since the results from single studies are inconclusive a systematic review was required. OBJECTIVES: To undertake a systematic review in patients with malignant lymphoma to determine the effectiveness of G-CSF and GM-CSF to prevent neutropenia, febrile neutropenia, infection, improve quality of life, adherence to the treatment protocol, tumour response, freedom from treatment failure (FFTF), overall survival (OS) and to assess adverse events of G-CSF and GM-CSF. SEARCH STRATEGY: Medline, Embase, CancerLit, the Cochrane Library and smaller databases, Internet-databases of ongoing trials, conference proceedings of the American Society of Clinical Oncology and the American Society of Hematology were searched. We included full-text and abstract publications as well as unpublished data. SELECTION CRITERIA: Randomised controlled trials comparing prophylaxis with G-CSF or GM-CSF versus placebo/no prophylaxis in adult patients with malignant lymphoma undergoing chemotherapy were included in this review. Both study arms had to receive identical chemotherapy and supportive care. DATA COLLECTION AND ANALYSIS: Eligibility and quality assessment, data extraction and analysis were done in duplicate. All authors were contacted to obtain missing data. MAIN RESULTS: We included 11 eligible studies with 1434 randomised patients. Compared with no prophylaxis, G-/GM-CSF significantly reduced the relative risk for severe neutropenia (RR 0.64 [95% CI 0.55-0.75]), febrile neutropenia (RR 0.74 [95% CI 0.62-0.89]) and infection (RR 0.74 [95% CI 0.64-0.85]). There was no evidence for G-/GM-CSF to decrease the number of patients who required iv antibiotics (RR 0.82 [95%CI 0.57-1.18]), to reduce infection related mortality (RR 2.07 [95% CI 0.81-5.34]), or to improve complete tumour response (RR 1.06 [95% CI 0.96-1.16]), FFTF (HR 1.22 [95% CI 0.83-1.80]) and OS (HR 0.98 [95% CI 0.81-1.18]). None of the studies evaluated quality of life parameters. REVIEWER'S CONCLUSIONS: G-CSF and GM-CSF, when given prophylactically in patients with malignant lymphoma undergoing conventional chemotherapy, reduce the risk of neutropenia, febrile neutropenia and infection. However, based on the currently available randomised trials in this clinical setting, there is no evidence for G-/GM-CSF to provide a significant advantage in terms of complete tumour response, FFTF and OS.

Antineoplastic Agents↗

[University clinics as centers of radiologic performance alliances in the ambulatory and inpatient sector].

PROBLEM: Health care delivery in Germany has to face severe challenges that will lead to a closer integration of services for in- and out-patients. University hospitals play an important role due to their activities in research, education and health care delivery. They are requested to promote and evaluate new means and ways for health care delivery. METHODS: The Institute of Clinical Radiology at the University Hospital of the Ludwig-Maximilians-University started teleradiological services for hospitals and general practices in January 1999 in the framework of the "Imaging services--teleradiological center of excellence". Legal, technical and organizational prerequisites were analyzed. RESULTS: Networks between university hospitals and general practices are not likely to solve all future problems. They will, however, increase the availability of the knowledge of experts even in rural areas and contribute to a quality ensured health care at the patients home. Future developments may lead to international co-operations and such services may be available to patients abroad. CONCLUSION: Legal, technical and organizational obstacles have to be overcome to create a framework for high quality telemedical applications. University hospitals will play an important role in promoting and evaluating teleradiological services.

Delivery of Health Care↗

[Improving productivity by implementing RIS and PACS throughout the clinic: a case study].

PROBLEM: How are improvements in productivity in connection with RIS/PACS to be defined? What do they cost? To limit the problem to the relevant topics, we first describe the objectives of a radiology department and the identified bottlenecks in the workflow. How to define and assess the improvements is discussed. METHODS: The case in question for this study is the RIS/PACS project at the "Klinikum der Universität München, Campus Grosshadern". The goals of the project and its present status are reviewed. The project is not yet completed, so this is a "midterm" report. RESULTS AND DISCUSSION: We describe the status of the achieved and not yet achieved goals and of the eliminated bottlenecks. On the plus side, for example, nearly 100% of all digitally generated images (except mammogramms) are digitally archived. They are accessible to the same percentage in radiology via PACS and in the hospital via the webbased intranet image distribution system when needed. In some radiology areas, such as multislice CT, already the reporting can no longer be performed without softcopy image interpretation. However, the full elimination of hardcopy images is still not reality, since the distribution to DICOM viewers for selected requesters with demands for almost reporting quality, high cost image displays is still in the testphase. To reduce film costs, images are being printed on a high resolution paper printer in addition to the intranet distribution during this transition period. On the negative side, due to a lack of job positions in the transcription rooms, about 40% of the reports are still being handwritten by radiologists. Furthermore, the dictated and transcribed reports are usually still not available early enough in the RIS and thereby in the intranet report distribution of the hospital. Here only a speech recognition system can remedy the situation. As soon as this problem is solved and the image distribution to the DICOM viewers works routinely, the reports and the images will be accessible within minutes to maximally within some hours after the examination. CONCLUSION: The goals reached so far suffered delays due to unforeseen problems and pitfalls. Altogether, a quieter operation and workflow in radiology has already been achieved, due to less inquiries from the requestors for unfinished examinations, images and/or image copies.

Computer Systems↗

[Interdisciplinary shock room management: personnel, equipment and spatial logistics in 3 trauma centers in Europe].

OBJECTIVE: To analyse common and divergent features of staff-related, equipmental and spatial/logistical concepts of three large trauma centers of highest health care level. METHODS: The health care mandate as well as the staff management, the organisational and the constructional-spacial structure of trauma room diagnostics and therapy of the trauma centers of the Universities of Leiden and Munich (Innenstadt) and the Zentralklinikum Augsberg are described. In particular the technical equipment and the process of the radiological diagnostic procedures in the trauma room are outlined. RESULTS: Staff availability and basic technical equipment of the trauma rooms are comparable between the three hospitals. Divergent concepts exist concerning the complexity of the initial radiologic examination protocols. Spacial connection and importance of computed tomography are also discussed controversially. Urgent interventional procedures are increasingly performed within the trauma room. Magnetic-resonance-tomography does not play a role in early care from multiple injured patients. CONCLUSION: Trauma centers have to meet certain personnel and technical prerequisites to guarantee a temporally optimised care for multiple injured patients. Differences between the three centers concerning the logistic sequence and the radiologic examination techniques used are mainly due to variable emphasis put on CT in the initial phase of patient care.

Critical Care↗

[Structured radiologic diagnosis in polytrauma].

PURPOSE: Development of a concept for structured diagnostic imaging in patients with multiple trauma. MATERIAL AND METHODS: Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented. Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality. RESULTS: This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients. CONCLUSION: Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality.

Emergency Service, Hospital↗

[Radiological diagnosis in acute craniocerebral trauma].

PURPOSE: Head injury alone or in combination with multiple trauma is the main cause of death and severe disability in individuals under 45 years old. This review is intended to describe the relevant imaging modalities, to analyze their specific value and limitations and to illustrate the most important radiologic findings. The indications for diagnostic imaging within the context of an interdisciplinary linkage of diagnostic and therapeutic measures are discussed. MATERIAL AND METHODS: Recent publications are analyzed and compared to the experiences of our own hospital. In terms of a critical synoptic assessment the currently best standard of care is described in consideration of an interdisciplinary care concept. RESULTS: Radiologic imaging modalities crucially contribute to the complete injury assessment and provide an indispensable basis for any therapeutic decision. Comprehensive neuromonitoring and reliable demonstration of delayed or secondary brain damage is impossible without modern imaging technology. Computed tomography (CT) further continues to be the most important imaging modality, while magnetic resonance imaging despite it's partly superior diagnostic informations remains reserved to particular diagnostic problems. CONCLUSIONS: Suitable constructive prerequisities, an interdisciplinary care concept and integration of the radiologist in hospital-adapted diagnostic and therapeutic algorithms significantly improves the outcome of patients with acute head injury. Beside the correct diagnosis itself the time to establish a diagnosis above all has a crucial impact on successful management and good outcome of these patients.

Angiography, Digital Subtraction↗

[Virtual colonoscopy--chances for a screening procedure?].

In principle, virtual colonoscopy is capable to be used as method for early detection of colorectal cancer (CRC), even if the accuracy of the method and radiation exposure are matters discussion in the radiological community. Virtual colonoscopy is able to detect any pathology which is relevant for early detection of CRC especially when using multislice CT, but also with single slice CT. The diagnosis of small lesions, less than 7 mm in diameter (polyps and flat lesions) is still problematic as it is in conventional colonoscopy. The exposure to x-rays in asymptomatic patients, without any increased risk of developing cancer is highly problematic and should be reduced to a minimum. Using special post processing filters on the volume dataset it can be shown that a tube current of 20 mAs is sufficient without any loss in accuracy. Measurements on the Alderson-phantom showed, that an effective dose exposure of 1.2 mSv is obtained using these reduced mAs values. It has to be differentiated between virtual colonoscopy for early detection of polyps and CRC in individual patients or as a screening examination of a large population. Virtual colonoscopy as a screening examination necessitates reduction of radiation dose, a high degree of automatization in 3D reconstructions as well as the assessment of the entire mucosa. High risk patients, whom refuse fibreoptic colonoscopy should undergo virtual colonoscopy. Virtual colonoscopy has a good chance to become an accepted tool for general screening, if efficient dose reduction, complete visualization of the colon mucosa and automatization of the post processing procedures can be achieved.

Colonic Polyps↗

Magnetic resonance imaging of metastatic disease to the brain with gadobenate dimeglumine.

Seventy-four patients with one to eight proven intraaxial brain metastases received a total cumulative dose of 0.2 mmol/kg bodyweight gadobenate dimeglumine, administered as sequential injections of 0.05, 0.05 and 0.1 m mol/kg over a 20-min period. MR imaging was performed before the first administration (T2- and T1-weighted sequences) and after each injection of contrast agent (T1-weighted sequences only). Quantitative assessment of images revealed significant (P <0.01) dose-related increases in lesion-to-brain (L/B) ratio and percent enhancement of lesion signal intensity. Qualitative assessment by two independent, blinded assessors revealed additional lesions in 22%, 25% and 38% (assessor 1) and 29%, 32% and 34% (assessor 2) of patients after each cumulative dose when compared with combined T1- and T2-weighted pre-contrast images. Significantly more lesions (P < 0.01) were noted by both assessors after the first injection and by one assessor after each subsequent injection. For patients with just one lesion observed on unenhanced T1- and T2-weighted images, additional lesions were noted in 12%, 16% and 28% of patients by assessor 1 following each dose and in 24%, 27% and 30% of patients by assessor 2. Contemporaneously, diagnostic confidence was increased and lesion conspicuity improved over unenhanced MRI. For patients with one lesion observed after an initial dose of 0.05 mmol/kg, additional lesions were noted by assessors 1 and 2 in 9.1% and 11.8% of patients, respectively, after a cumulative dose of 0.1 mmol/kg and in a further 9.1% and 5.9% of patients, respectively, after a cumulative dose of 0.2 mmol/kg. No safety concerns were apparent.

Brain Neoplasms↗

[Detection of coronary calcinosis with multislice spiral computerized tomography: an alternative to electron beam tomography].

Electron-beam CT (EBT) has been used for years as the gold standard to quantify coronary artery calcification as a marker of coronary atherosclerosis. With the introduction of Multi-Slice Spiral CT (MSCT) technology in 1999, EBT is now challenged in the determination of coronary calcium. The aim of this study was to determine the diagnostic accuracy of MSCT for the assessment of coronary calcium, comparing this new technique to EBT. The study population consisted of 54 male patients, aged 58 +/- 11 years with suspected coronary artery disease. For EBT, 40 axial slices (scan time = 100 ms, slice thickness = 3 mm) were acquired in one breath-hold (35 +/- 5 s) using an ECG-trigger at 80% of the RR interval. For MSCT, simultaneous acquisition of four axial slices (scan time = 250 ms, slice thickness = 2.5 mm) allowed the entire heart (40 slices) to be covered in one breath-hold (25 +/- 5 s) using a prospective ECG-trigger (R--450 ms). For quantification of coronary calcium the Agatston and the Volumetric calcium score (VCS) were applied. Mean Agatston score of the study group was calculated as 88 +/- 111 (median = 45), which is between the 25th and 75th age-corrected percentile of asymptomatic patients. For the Volumetric calcium score, number of lesions, calcium mass and density, no statistical difference was found between both imaging modalities. Agatston and Volumetric calcium score were statistically different between and within both scans. Mean variability of VCS of the two methods was calculated as 24% and was in the range of repeated EBT studies (14-44.9%). The Multi-Slice Spiral CT scanner is equivalent to EBT for the determination of coronary calcium and can, therefore, be used for calcium screening. Using a prospective ECG-trigger technique, the application of the Agatston method delivers statistically different results in comparison to EBT. With the application of the spiral mode technique, retrospective ECG-trigger and thinner slice thickness, further improvement in variability can be expected, thus allowing for follow-up studies to determine progression or regression of atherosclerosis with high accuracy.

Aged↗

[Quantitative cartilage analysis with magnetic resonance tomography (qMRI)--a new era in arthrosis diagnosis?].

Magnetic resonance imaging (MRI) is a new and very powerful method for the diagnostics and monitoring of osteoarthritis. Its advantage is that all articular tissues can be visualized directly and are accessible for three-dimensional analysis. This article reviews qualitative, semi-quantitative, and quantitative studies on articular cartilage with MRI. In particular we discuss pulse sequences and three-dimensional postprocessing methods for quantitative analysis of cartilage volume and thickness, along with their accuracy and precision in healthy volunteers and patients with osteoarthritis. It addition, we present approaches for quantitative analyses of structural/biochemical parameters and for the deformational behavior of cartilage in vivo.

Cartilage, Articular↗

[Minimally invasive surgical procedures of the breast: comparison of different biopsy systems in a breast parenchymal model].

PURPOSE: The purpose of our study was to evaluate various systems for large core biopsy. First to determine the volume of specimen that can be removed with each minimal-invasive method and second to compare their consistency. With respect to the optimum of volume which can be acquired the 12-G system should be optimized by special modifications. METHODS: Examinations were performed on a phantom. We used 8 automatic, one sequential-automatic and 4 halfautomatic highspeed core biopsy systems of 16-, 14- and 12 G as well as the 11G vacuum biopsy. The weight and consistency of the specimen was determined in every case. The 12G system was optimized by enlargement of the biopsy chamber. RESULTS: The 11G vacuum biopsy exhibited best results concerning the weight of the specimen (93.7 +/- 13.5 mg). The results achieved with high speed core biopsy varied with the needle diameter as well as with the technique. Semi- and halfautomatic systems were superior to automatic systems. Best results among highspeed core biopsy systems were achieved with the modified 12G biopsy needle (41.3 +/- 4.4 mg). CONCLUSION: As expected, largest volume of specimen can be removed with vacuum biopsy. High speed core biopsy systems are inferior to vacuum biopsy. Nevertheless, the amount of volume achieved can be increased to 22.4 mg by using 14G needles and to 41.3 mg by using 12G needles. The modified 12-G needle may be considered as an less expensive alternative to 11G vacuum biopsy.

Biopsy↗

[Stereotactic vacuum biopsy in prone and sitting position].

PURPOSE: The purpose of our study was to determine the accuracy of vacuum-assisted biopsy (VB) and to evaluate the side effects of this method depending on the positioning of the patient during the intervention. METHODS: Interventions were performed with the 11-G biopsy needle either in prone position (Mammotest S, Fischer Imaging, USA) on a dedicated table for breast intervention (n = 308) or in upright position with a dedicated digital stereotactic mammography system (Mammomat 3000, Optima, Siemens, Germany). VB was indicated because of indeterminate or suspicious microcalcifications (84.1%) or because of dense lesions (15.9%). All benign results found with VB have been followed up after 6 and 12 months by mammography. All malignant or histological findings discordant to imaging features have been verified by open surgery. RESULTS: Histology after VB offered 215 (64.4%) benign lesions. In neither case a carcinoma developed during follow-up. In 90 (27%) cases malignancy was found with VB. After reexcision the diagnosis of VB was confirmed in 85.6%. In 8.9% of the cases in which VB showed DCIS, histology after open surgery revealed also invasive tumor components. Technical problems occurred in 4 cases. Major side effects developed neither in prone position nor in upright, sitting position of the patient. CONCLUSION: VB is a reliable method with less side effects for the histological evaluation of breast lesions. The accuracy and complications are not depending on the type of stereotactic device or on the patients position. The accuracy of the histological diagnosis achieved with VB can be compared to that of open surgery. The relative high costs of this method may cause a problem. But compared to the costs resulting by open diagnostic surgery this disadvantage is only a relative one.

Adult↗

Current treatment of follicular non-Hodgkin's lymphoma.

56200 new cases of NHL are expected to be diagnosed in the United States (US) per year. For reasons that are not fully understood, the number of new cases per year has nearly doubled in the past three decades. Most patients with follicular lymphoma are over 50 years of age and present with widespread disease at diagnosis. Nodal involvement is very common, often accompanied by splenic and bone marrow disease. Despite the advanced stage, the median survival ranges from 8 to 12 years. The vast majority of patients with advanced stage follicular lymphoma are not cured using the current therapeutic options. The rate of relapse is fairly consistent over time, even in patients who have achieved complete responses (CRs) to treatment. Therapeutic options in follicular NHL include watchful waiting, oral alkylating agents, purine nucleoside analogues, combination chemotherapy, interferon and monoclonal antibodies. Radiolabelled monoclonal antibodies, autologous or allogeneic bone marrow or peripheral stem cell transplantation are under current clinical evaluation. The approval of rituximab, an unconjugated chimeric antibody against the CD20 antigen for the treatment of relapsed follicular B-cell NHL marked a milestone in the development of antibody treatment. In addition, newer approaches like radioimmunoconjugates with myeloablative activity induced response rates of 80-100% in heavily pretreated patients. Various clinical trials combining monoclonal antibodies with conventional therapies are currently ongoing to determine whether these new biological agents will alter the natural history of follicular lymphoma.

Aged↗

Functional adaptation of human joints to mechanical stimuli.

OBJECTIVE: This study tests the hypothesis that functional adaptation occurs in human joints, and that substantial differences in joint 'loading history' explain the phenotypic variability observed in human cartilage morphology. METHOD: We examined 18 triathletes (nine men and nine women) who had been physically active throughout life (training for >10 h per week for the last 3 years), and 18 volunteers that had never been physically active on a regular basis. The right knee joints were imaged with a previously validated fat-suppressed gradient-echo MR sequence. Cartilage volume, thickness, joint surface areas, and normalized cartilage signal intensity were determined with post-processing software, specifically designed for these applications. RESULTS: The knee joint cartilage thickness, and signal intensity were not significantly different between athletes and inactive volunteers, but male athletes displayed significantly larger knee joint surfaces (P< 0.01; +8.8%). Female athletes displayed a significantly larger medial tibia (P< 0.05; +18.9%), the difference in the total knee surface area reaching borderline significance (P=0.08; +7.0%). CONCLUSIONS: The results suggest that joint size can be modulated during growth, but that (opposite to muscle and bone) the thickness of the cartilage does not adapt to mechanical stimulation. This finding may reveal a general principle in the development and functional adaptation of diarthrodial joints, elucidating an important mechanism for reducing mechanical stress in biphasic cartilage layers.

Adaptation, Physiological↗