Search PubMed⌕ Search

Biomedical subjects

M Reinhardt

Publications and source records attributed to M Reinhardt.

At least 19 recordsLinked to original sources

[Technical limits of PET/CT with 18FDG in prostate cancer].

There is increasing evidence that (18)FDG-PET is not useful for the imaging of primary prostate cancer. The aim of this examination was to prove whether or not these poor results are due to technical deficiencies of the examination method like older image reconstruction techniques, extensive (18)FDG-tracer activity in the bladder or improper contrast staining of the rectum. We examined three patients with primary prostate cancer using a modern combined PET/CT system, continuous irrigation of the bladder and an air-inflated rectal balloon catheter. PET/CT images show an exact depiction of both the prostate and all surrounding anatomic structures but no enhanced uptake of radiotracer in the tumour. Therefore, the mentioned poor results of (18)FDG-PET seem not to be due to technical deficiencies.

Adenocarcinoma↗

Ultrasound derived imaging and quantification of cell adhesion molecules in experimental autoimmune encephalomyelitis (EAE) by Sensitive Particle Acoustic Quantification (SPAQ).

Molecular imaging requires, not only the identification of an appropriate marker, but also its quantitative analysis. We used the Sensitive Particle Acoustic Quantification (SPAQ) technology - a novel ultrasound technique - for detection and quantification of cell adhesion molecules in isolated tissue and in live animals. By conjugating gas-filled microparticles (MPs) with antibodies to intercellular adhesion molecule 1 (ICAM-1) and vascular cell adhesion molecule 1 (VCAM-1), we were able to depict and quantify ICAM-1 and VCAM-1 in isolated brain and spinal cord from rats with autoimmune encephalomyelitis (EAE), an established inflammatory disease model of human multiple sclerosis (MS). Depiction and quantification of specific MPs were also feasible in living animals with AT-EAE with similar results. After treatment with methylprednisolone, the measured number of targeted anti-ICAM-1 and VCAM-1-MPs was significantly lower (P<0.01) compared to untreated animals demonstrating the high sensitivity of this imaging technique. Depending on the antibody linked to the surface of the MPs, the technique can be used to quantify the expression of any accessible antigen expressed on the luminal surface of endothelial cells and is therefore a promising tool for the non-invasive and dynamic assessment of disease-related molecules.

Animals↗

[PET-CT studies of the support system and continence function of pelvic organs. The pivotal importance of Denonvilliers' fascia for surgical procedures].

Like all other organs in the chest or abdominal cavities, pelvic organs are not suspended by specialized ligaments such as those in the skeletomuscular system. In spite of this, the organs of the pelvis remain well suspended within their cavity even during evacuation. This support system for these organs consists of inconspicuous smooth muscle elements scattered throughout pelvic structural fat tissue and fascial structures, in particular Denonvilliers' fascia. We used PET-CT studies to identify spontaneous muscle activity in the pelvis, which is strongest at Denonvilliers' fascia. We were able to correlate continence function, filling, and evacuation of pelvic organs with this spontaneous muscle activity that leads to stiffening and relaxation of the muscular walls of these organs. During the course of different disease processes such as visceral prolapse, these pelvic support structures are prone to fail gradually. Surgical interventions should take the pelvic support system into account to avoid therapeutic errors.

Aged↗

[Possible target specific molecular imaging with ultrasound contrast agents].

Non-invasive molecular imaging technologies provide researchers with the opportunity to study cellular and molecular processes. Among different imaging technologies, ultrasound based molecular imaging methods are also of interest, since the use of ultrasound contrast agents allows specific and sensitive depiction of molecular targets. Recent studies are encouraging and have demonstrated the feasibility of ultrasound based molecular imaging. This review summarizes current experiences and recent preclinical studies with target-specific ultrasound contrast agents.

Animals↗

[Combined FDG PET/CT imaging for restaging of colorectal cancer patients: impact of image fusion on staging accuracy].

PURPOSE: To evaluate the diagnostic impact of positron emission tomography (PET) with fluorine-18-labeled deoxy-D-glucose (FDG) combined with non-contrast computed tomography (CT) as PET-CT modality in restaging colorectal cancer patients. MATERIAL AND METHODS: In this retrospective study, 29 consecutive patients with histologically proven colorectal cancer (17 female, 12 male, aged 51-76 years) underwent whole body scans in one session on a dual modality PET-CT system (Siemens Biograph) 90 min. after i.v. administration of 370 MBq 18F-FDG. The CT imaging was performed with 40 mAs, 130 kV, slice-thickness 5 mm and without i.v. contrast administration. PET and CT images were reconstructed with a slice-thickness of 5 mm in coronal, sagittal and transverse planes. During a first step of analysis, PET and CT images were scored blinded and independently by a group of two nuclear medicine physicians and a group of two radiologists, respectively. For this purpose, a five-point-scale was used. The second step of data-analysis consisted of a consensus reading by both groups. During the consensus reading, first a virtual (meaning mental) fusion of PET and CT images and afterwards the "real" fusion (meaning coregistered) PET-CT images were also scored with the same scale. The imaging results were compared with histopathology findings and the course of disease during further follow-up. RESULTS: The total number of malignant lesions detected with the combined PET/CT were 86. For FDG-PET alone it was n = 68, and for CT alone n = 65. Comparing PET-CT and PET, concordance was found in 81 of 104 lesions. Discrepancies predominantly occurred in the lung, where PET alone often showed true positive results in lymph nodes and soft tissue masses, where CT often was false negative. Comparing mental fusion and "real" co-registered images, concordance was found in 94 of 104 lesions. In 13 lesions or, respectively, in 7 of 29 patients, a relevant information was gathered using fused images. CONCLUSION: Combined PET/CT leads to greater accuracy in the interpretation of data and is a valuable tool for diagnosis and anatomic localization of metastases in colorectal cancer patients.

Aged↗

Myocardial perfusion/metabolism mismatch and ventricular arrhythmias in the chronic post infarction state.

AIM: Ventricular arrhythmias have been shown to originate in the myocardial peri-infarct region due to irregular heterotopic conduction. Hypoperfused but viable myocardium is often localised in those areas and may be involved in the pathogenesis of arrhythmias. We tested the hypothesis that these myocardial perfusion/metabolism mismatches (MM) are significantly associated with ventricular arrhythmias in the chronic post infarction state. PATIENTS, METHODS: 47 post infarction patients were included in the study. 33 suffered from ventricular arrhythmia whereas 14 did not. All patients underwent (99m)Tc tetrofosmin SPECT and (18)F-FDG PET. A region-of-interest(ROI)-analysis was used to assess viable myocardium based on predefined MM-criteria. Univariate analyses as well as a logistic regression model for the multivariate analysis were carried out. RESULTS: 94% of the arrhythmic patients displayed at least one MM-segment as compared to 64% of the non-arrhythmic patients. MM-segments and arrhythmia showed a statistically significant relation (p = 0.018). The logistic regression model predicted the occurrence or absence of arrhythmia in 85% of all cases. Multivariate analysis gave consistent results, after adjusting for symptomatic chronic heart failure (CHF), aneurysms and age. CONCLUSION: Our results support the hypothesis that hypoperfused but viable myocardium represents an arrhythmogenic substrate and is a relevant risk factor for developing ventricular arrhythmias following myocardial infarction. Therefore, the detection of MM-segments allows the identification of patients with a higher risk for future cardiac events.

Coronary Disease↗

Long term changes in serum T4, T3, and TSH in benign thyroid disease: proof of a narrow individual variation.

AIM: The diagnosis of abnormalities of thyroid function is generally based on the measurement of thyroid hormones and TSH in blood. The recommended reference ranges for serum T4 and T3 as well as TSH are quite wide as the result of large differences in thyroid function tests in healthy persons. It has been proven that the individual variation within an individual is small, compared with the variation between individuals. We investigated long term variations of these parameters in patients with and without benign thyroid diseases. METHODS: We performed long term follow-up serum determinations of T3, T4, and TSH in a total of 150 patients for a time period of 3 to 13 years. The majority of patients had been put on L-thyroxine. Values of total T3, total T4, free T4 were measured with an almost unmodified test (RIA) over the years. RESULTS: The lowest relative coefficient of variation (<10%) was observed in the group of patients who had been treated with L-thyroxine only. Even for TSH, relatively low cofficients of variation were observed in this group. In the group of patients who had not received any medication, T3 and T4 showed also a variation of 10%. FT4 and TSH revealed a wider range of variation. Even after radioiodine therapy, T3 and T4 showed only a quite small variation, while TSH demonstrated a wide range with a variation of >30%. CONCLUSION: Our data demonstrate that there are only narrow variations of serum T4 and T3 within individuals with and without thyroid disorders.

Female↗

[Effectiveness of syringe shieldings using radionuclides in radiation synovectomy].

AIM: The radiation exposure in radiation synovectomy was investigated for technician and therapist using Erbium-169, Rhenium-186 and Yttrium-90 with and without syringe shieldings. METHODS: Dose rates were measured in relation to the distance of the syringe containing the radionuclide. Measurements were repeated using syringe shieldings which consist of plastic surrounded by a lead layer. RESULTS: The most relevant radiation exposure arises from Yttrium-90. Using syringe shieldings radiation exposure can be reduced by a factor of thousand. CONCLUSION: This kind of radiological protection is completely sufficient for the therapist. Concerning the technician preparing the radiopharmaceutics, the limit of the official German dosimetry service (500 mSv) might be exceeded if no special radiological protection is established. Thus, special dosimetry is recommended.

Humans↗

Topology of an intracellular transduction chain (phototropism of Phycomyces): 1. Joint review of functional, temporal, and spatial aspects.

Two light-induced growth reactions in a unicellular cylindrical sporangiophore of Phycomyces blakesleeanus-vertical growth acceleration under symmetrical irradiation (photomecism) and directional growth under unilateral irradiation (phototropism)-share common input light perception as well as common output growth mechanism but have strongly divergent dynamics and other distinctive features. This divergence culminates in the phototropic paradoxes the main of which states that photomecism shows total adaptation, while phototropism does not adapt. The basis for this contradiction is that the phototropic transduction chain, unlike that of photomecism, faces a spatially non-uniform stimulus and processes a series of spatial patterns (light and absorption profiles, adaptation profile, etc.). The only way to resolve the paradoxes and correlate features of both responses within a single transduction chain is to assume non-local signal transduction, e.g. a cross-talk between different azimuthal locations within the cylindrical cell. On the other hand, to establish the presence of an appropriate cross-talk is equivalent of gaining insight into the topology of the transduction chain. This series of two papers contains a review reconsidering the entire field from this viewpoint (Paper 1) and a mathematical model of pattern transduction which unifies features of phototropism and resolves the paradoxes (Paper 2). At the same time, this is the first "proof of concept" for the "activity/pooling (a/p) networks"-a specific mathematical apparatus designed to analyse systemic properties and control in metabolic pathways.

Absorption↗

Nasal immunisation with Salmonella typhimurium producing rotavirus VP2 and VP6 antigens stimulates specific antibody response in serum and milk but fails to protect offspring.

Rotavirus specifically infects the small intestine of young infants resulting in severe diarrhoea. Mucosal antibody responses are required to cure the infection, and mucosal administration of rotavirus-like particles induces protective immunity without requiring a mucosal adjuvant such as cholera toxin. In addition, the rotavirus protein VP6 has been defined as a protective antigen in an adult mouse rotavirus infection model. Salmonella typhimurium is an epithelium-invasive bacterium that induces specific immune responses in mucosal tissues against itself and carried antigens. In this work, we investigated the capacity of a live recombinant S. typhimurium vaccine to stimulate antibody responses against rotavirus. We constructed an attenuated S. typhimurium strain simultaneously producing VP6 and VP2 rotavirus proteins in the cytoplasm. In contrast to expression in eukaryotic cells, VP6 and VP2 did not form virus-like particles in our bacterial system. After nasal administration of female mice, the live recombinant Salmonella were able to elicit an antibody response specific to both VP2 and VP6 in serum and milk. However, these antibodies failed to passively protect the offspring against rotavirus-induced diarrhoea.

Administration, Intranasal↗

2-(fluorine-18)fluoro-2-deoxy-D-glucose positron emission tomography in the detection and staging of malignant lymphoma. A bicenter trial.

BACKGROUND: The authors undertook a prospective evaluation of the clinical value of 2-fluoro [18-]-2-deoxyglucose positron emission tomography (FDG-PET) in the detection and staging of malignant lymphoma compared with computed tomography (CT) and bone marrow biopsy (BMB). METHODS: Fifty-two consecutive patients with untreated malignant lymphoma were evaluated prospectively in a bicenter study. FDG-PET, CT, and BMB were performed for investigating lymph node/extranodal manifestations and bone marrow infiltration. Thirty-three percnt of the discrepant results were verified by biopsy, magnetic resonance imaging, or clinical follow-up (range, 4-24 month). RESULTS: Altogether, 1297 anatomic regions (lymph nodes, organs, and bone marrow) were evaluated. FDG-PET and CT scans were compared by receiver operating characteristic (ROC) curve analysis. The area under the ROC curve were as follows: lymph nodes, 0.996 (PET) and 0.916 (CT); extranodal, 0.999 (PET) and 0.916 (CT); supradiaphragmatic, 0.996 (PET) and 0.905 (CT); and infradiaphragmatic, 0.999 (PET) and 0.952 (CT). In these analyses, FDG-PET was significantly superior to CT (P < 0.05), except in infradiaphragmatic regions, in which the two methods produced equivalent results. In detecting bone marrow infiltration, FDG-PET was superior to CT and was equivalent to BMB. In 4 of 52 patients (8%), FDG-PET led to an upstaging and a change of therapy. CONCLUSIONS: Noninvasive FDG-PET is very accurate in the staging of malignant lymphoma. Compared with standard staging modalities (CT and BMB), PET was significantly superior and led to changes in the therapy regimen for 8% of patients.

Adolescent↗

FDG-PET imaging for the staging and follow-up of small cell lung cancer.

The staging procedures for small cell lung cancer do not differ appreciably from those for other forms of lung cancer. For practical purposes, the TNM stages are usually collapsed into a simple binary classification: limited disease and extensive disease. This study was performed to answer the question of whether fluorine-18 labelled 2-deoxy-2-D-glucose positron emission tomography (FDG-PET) imaging permits appropriate work-up (including both primary and follow-up staging) of patients presenting with small cell lung cancer, as compared with currently recommended staging procedures. Thirty-six FDG-PET examinations were performed in 30 patients with histologically proven small cell lung cancer. Twenty-four patients were examined for primary staging while four were imaged for therapy follow-up only. Two patients underwent both primary staging and up to four examinations for therapy follow-up. Static PET imaging was performed according to a standard protocol. Image reconstruction was based on an ordered subset expectation maximization algorithm including post-injection segmented attenuation correction. Results of FDG-PET were compared with those of the sum of other staging procedures. Identical results from FDG-PET and the sum of the other staging procedures were obtained in 23 of 36 examinations (6x limited disease, 12x extensive disease, 5x no evidence of disease). In contrast to the results of conventional staging, FDG-PET indicated extensive disease resulting in an up-staging in seven patients. In one patient in whom there was no evidence for tumour on conventional investigations following treatment, FDG-PET was suggestive of residual viability of the primary tumour. Furthermore, discordant results were observed in five patients with respect to lung, bone, liver and adrenal gland findings, although in these cases the results did not affect staging as limited or extensive disease. Moreover, FDG-PET appeared to be more sensitive for the detection of metastatic mediastinal and hilar lymph nodes and bone metastases. Finally, all findings considered suspicious for tumour involvement on the other staging procedures were also detected by FDG-PET. It is concluded that FDG-PET has potential for use as a simplified staging tool for small cell lung cancer.

Adult↗

Acoustic behaviour of current ultrasound contrast agents.

A general law gives the approximate change in signal level obtained in a particular imaging mode when a suitable contrast agent is added. It also shows that reduction of background signals is essential to overcome limitations found mainly in conventional (linear) ultrasound contrast imaging. Contrast agents contain stabilized microbubbles with very helpful non-linear properties. Acoustic methods for non-destructive and destructive testing of microbubbles are briefly discussed. In the main part, the linear and non-linear acoustic behaviour of various types of contrast agent are described. The latter is useful for new applications in diagnostic ultrasound.

Acoustics↗