Search PubMed⌕ Search

Biomedical subjects

M Reginatto

Publications and source records attributed to M Reginatto.

16 recordsLinked to original sources

Determination of the full response function of personal neutron dosemeters.

The response of neutron dosemeters may be determined directly from measurements, provided a sufficiently large number of measurements in monoenergetic neutron fields covering the entire energy range of interest is available. In practice this is not feasible due to the lack of monoenergetic neutron fields in the thermal and intermediate energy region (i.e. energies<24 keV). To deal with this difficulty, we have developed a method which can take into account additional information about the response of the dosemeter. Our analysis makes use of two types of data, measurements made using monoenergetic neutron beams and measurements made in neutron fields with broad energy distributions. The dosemeter responses are described using a parametrised model, based on a minimum of assumptions: that they should fit the data within experimental uncertainties, and that they should remain close to a simple interpolation of the monoenergetic and thermal neutron field data.

Algorithms↗

Bayesian approach for quantifying the uncertainty of neutron doses derived from spectrometric measurements.

Bayesian methods provide a unified framework for combining information in the presence of uncertainty. All uncertainties that enter into the description of a measurement are modelled using probability distributions, and these are handled according to the rules of probability theory, ensuring that the approach is free of inconsistencies. The final result of the analysis is the full probability distribution for the parameter of interest, and from this distribution an appropriate uncertainty interval can be obtained. Some of the advantages of a Bayesian analysis include a straightforward approach to the problem of dealing with nuisance parameters, the ability to incorporate prior information in a natural way and the flexibility that is necessary for a realistic modelling of the measurement process. As an example, the problem of deriving neutron dose estimates and their uncertainties based on measurements carried out using a Bonner sphere spectrometer is considered.

Bayes Theorem↗

Performance of the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities.

This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources ((241)AmBe; (252)Cf; (252)Cf(D(2)O)\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory.

Dose-Response Relationship, Radiation↗

Evaluation of individual monitoring in mixed neutron/photon fields: mid-term results from the EVIDOS project.

EVIDOS is an EC sponsored project that aims at an evaluation and improvement of radiation protection dosimetry in mixed neutron/photon fields. This is performed through spectrometric and dosimetric investigations during different measurement campaigns in representative workplaces of the nuclear industry. The performance of routine and, in particular, novel personal dosemeters and survey instruments is tested in selected workplace fields. Reference values for the dose equivalent quantities, H(*)(10) and H(p)(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence and using newly developed devices that determine the energy and directional distribution of the neutron fluence. The EVIDOS project has passed the mid-term, and three measurement campaigns have been performed. This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire.

Equipment Design↗

Electronic neutron personal dosemeters: their performance in mixed radiation fields in nuclear power plants.

This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent H(p)(10) and effective dose E are determined for different directions of a person's orientation in these fields and readings of personal neutron dosemeters--especially electronic dosemeters--are discussed with respect to H(p)(10) and E.

Dose-Response Relationship, Radiation↗

Measurement of energy and direction distribution of neutron and photon fluences in workplace fields.

Within the EU Project EVIDOS, a spectrometer with 24 silicon detectors mounted on the surface of a polyethylene sphere is used for the determination of the energy and direction distribution of neutrons and photons. It has been characterized with respect to neutron radiation with energies from thermal up to 15 MeV and to photon radiation with energies from 65 keV to 6 MeV. The first measurements described here were performed in the simulated workplace field, CANEL, at Cadarache, with the purpose of checking the instrument and the unfolding procedures.

Environmental Exposure↗

Individual neutron monitoring in workplaces with mixed neutron/photon radiation.

EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron fluence from which the reference dosimetric quantities are derived and compared to the readings of dosemeters. The final results of the project will be a comprehensive set of spectrometric and dosimetric data for the workplaces and an analysis of the performance of dosemeters, including novel electronic dosemeters. This paper gives an overview of the project and focuses on the results from measurements performed in calibration fields with broad energy distributions (simulated workplace fields) and on the first results from workplaces in the nuclear industry, inside a boiling water reactor and around a spent fuel transport cask.

Artifacts↗

Characterisation of the IRSN CANEL/T400 facility producing realistic neutron fields for calibration and test purposes.

The new CANEL/T400 facility has been set-up at the Institute for Radiological Protection and Nuclear Safety (IRSN) to produce a realistic neutron field. The accurate characterisation of this neutron field is mandatory since this facility will be used as a reference neutron source. For this reason an international measuring campaign, involving four laboratories with extensive expertise in neutron metrology and spectrometry, was organised through a concerted EUROMET project. Measurements were performed with Bonner sphere (BS) systems to determine the energy distribution of the emitted neutrons over the whole energy range (from thermal energy up to a few MeV). Additional measurements were performed with proton recoil detectors to provide detailed information in the energy region above 90 keV. The results obtained by the four laboratories are in agreement with each other and are compared with a calculation performed with the MCNP4C Monte-Carlo code. As a conclusion of this exercise, a reliable characterisation of the CANEL/T400 neutron field is obtained.

Algorithms↗

An unfolding method for directional spectrometers.

The development of new spectrometers that are sensitive to the directional distribution of neutrons requires new unfolding methods that can determine the distribution of the neutron fluence as a function of energy and angle. Such information is needed to compute non-isotropic dosimetric quantities (e.g. personal dose equivalent and effective dose). We describe an unfolding method that applies the maximum entropy principle to this problem. It maximises the relative entropy, defined as the information-theory entropy of the distribution of the neutron fluence relative to a distribution that encodes prior knowledge, subject to constraints imposed by the measurements. We provide examples of the applicability of the method using data from two directional spectrometers of different design that have been developed in the context of EVIDOS, a project concerning mixed neutron-photon field analysis in the nuclear industry.

Anisotropy↗

A telescope-design directional neutron spectrometer.

A directional spectrometer that uses a superheated emulsion of dichlorotetrafluoroethane at the centre of a 30 cm diameter moderating-sphere of nylon-6. The system has a telescope-design wherein the detector views a narrow solid angle of about 1/6 steradians. The hydrogenous sphere effectively attenuates laterally incident neutrons, thus providing a strong angular dependence of the response. The central detector is sequentially operated at seven temperatures between 25 and 55 degrees C in order to generate a matrix of nested response functions suitable for few-channel spectrometry. The response matrix of the system has been determined by calibrations with monoenergetic neutrons and by Monte Carlo neutron transport calculations. The double-differential unfolding method developed for this system applies the principle of maximum entropy and allows for the rigorous use of all a priori information. The spectrometer is intended for use in the mixed neutron/photon fields encountered in the nuclear power industry, being suitable for spatially distributed radiation sources with maximum neutron energies up to 10 MeV.

Anisotropy↗

Measurement of the energy spectrum of cosmic-ray induced neutrons aboard an ER-2 high-altitude airplane.

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the atmospheric ionizing radiation (AIR) project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to >10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was eight times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56-201 g cm-2 atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Aerospace Medicine↗

MAXED, a computer code for maximum entropy deconvolution of multisphere neutron spectrometer data.

Reliable neutron dosimetry requires knowledge of the neutron spectrum. We discuss the problem of analyzing data from a multisphere neutron spectrometer to infer the energy spectrum of the incident neutrons and describe the code MAXED, a computer program developed to apply the maximum entropy principle to this problem. The code and documentation are available from the authors upon request.

Documentation↗

An alternative approach to hot spot identification using in situ gamma spectrometry measurements on a grid.

We describe the application of a computer code developed to analyze data from a series of in situ gamma spectrometry measurements on a grid. The code was designed to be used as a tool when evaluating compliance with regulations that set limits on the size and magnitude of elevated activity areas (also known as "hot spots"). It calculates location and magnitude of potential elevated activity areas consistent with the data, and for each potential elevated area it generates a corresponding distribution of radionuclides in the soil. The algorithm uses a maximum entropy deconvolution of the data, followed by further analysis. A test case using data from actual field measurements is presented.

Entropy↗

Calculation of dose, dose equivalent, and relative biological effectiveness for high charge and energy ion beams.

The Green's function for the transport of ions of high charge and energy is utilized with a nuclear fragmentation database to evaluate dose, dose equivalent, and RBE for C3H10T1/2 cell survival and neoplastic transformation as a function of depth in soft tissue. Such evaluations are useful to estimates of biological risk for high altitude aircraft, space operations, accelerator operations, and biomedical applications.

Aircraft↗