Search PubMed⌕ Search

Biomedical subjects

M R Prince

Publications and source records attributed to M R Prince.

94 records · Page 6Linked to original sources

Detection of perivenous inflammation in a rat model of venous thrombosis using MRV.

Venous thrombosis is associated with a significant inflammatory response in the vein wall, which can be imaged noninvasively with gadolinium (Gd)-enhanced magnetic resonance venography (MRV). Interleukin-10 (IL-10), a naturally occurring anti-inflammatory cytokine, has been found to decrease the inflammatory response at the proper dosage and timing of administration. The present study determines if MRV with Gd is useful in a rat model of stasis-induced venous thrombosis to document the anti-inflammatory effects of rIL-10. Rats underwent laparotomy and ligation of the inferior vena cava (IVC). Animals were infused with rIL-10 at 2.5 microg (n = 6), rIL-10 at 10 microg (n = 6), or rIL-10 at 40 microg (n = 6). Six animals without IVC ligation or drug infusion served as controls. Two days after thrombosis induction, the rats underwent MRV with both time-of-flight imaging and pre/post-Gd T1-weighted imaging. Inflammation was analyzed by measuring the area of Gd enhancement at the point of IVC thrombosis. Enhancement area was also measured in the distal IVC where flow persisted. All animals with IVC ligation developed thrombosis, and all control rats were free of thrombus. In areas where flow remained, the area of enhancement was 1.8 +/- 0.4 mm2, while controls demonstrated 3.8 +/- 1.0 mm2 enhancement. Enhancement was significantly greater in all groups at the level of thrombus compared to the area of distal IVC flow and control IVCs (p < .001). Animals receiving rIL-10 at 40 microg revealed the most enhancement, 32.7 +/- 6.2 mm2, while the least enhancement was noted with 2.5 microg, 14.7 +/- 1.5 mm2 (p < .05). In conclusion, Gd-enhanced MRV was found useful in this rat model of stasis-induced venous thrombosis to document inflammation noninvasively and to evaluate the effects of anti-inflammatory interventions during stasis-induced IVC venous thrombosis.

Animals↗

Thoracic MR aortography: imaging techniques and strategies.

Three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography is a promising technique for thoracic aortography that complements electrocardiographically gated T1-weighted spin-echo imaging and cine MR imaging. Axial and left anterior oblique T1-weighted spin-echo images are well suited to measurement of aortic dimensions and evaluation of aortic aneurysms. Sagittal and coronal spin-echo images are helpful in evaluation of vascular rings and aortic dissection. Cine gradient-echo and cine phase-contrast imaging allow dynamic evaluation of aortic and valvular flow. Cine phase-contrast imaging also enables noninvasive quantification of blood flow. Capable of being performed during a single breath hold, 3D gadolinium-enhanced MR angiography provides high-resolution 3D data that can be readily used for projection angiography and multiplanar reformation. This technique enables further demonstration of subtle pathologic conditions. Three-dimensional gadolinium-enhanced MR angiography allows more comprehensive and efficient evaluation of the thoracic aorta.

Aged↗

Diagnosis of renal vascular disease with MR angiography.

Renal magnetic resonance (MR) angiography allows accurate evaluation of patients suspected to have renal artery stenosis without the risks associated with nephrotoxic contrast agents, ionizing radiation, or arterial catheterization. Other applications of renal MR angiography are mapping the vascular anatomy for planning renal revascularization, planning repair of abdominal aortic aneurysms, assessing renal bypass grafts and renal transplant anastomoses, and evaluating vascular involvement by renal tumors. A variety of pulse sequences provide complementary information about kidney morphology, arterial anatomy, blood flow, and renal function and excretion. Three-dimensional gadolinium-enhanced MR angiography can be combined with several other sequences to produce a comprehensive approach to renal MR angiography. This comprehensive approach is designed to allow hemodynamic characterization of renal artery stenosis with a single MR imaging examination that can be easily completed in 1 hour. Three-dimensional gadolinium-enhanced MR angiography demonstrates the renal arteries along with the abdominal aorta, iliac arteries, and mesenteric arteries in a 20-30-second acquisition that can be performed during breath holding. Numerous projections are reconstructed from a single three-dimensional volume of data acquired with a single injection of contrast material to obtain perpendicular and optimized views of each renal artery.

Anastomosis, Surgical↗

MR angiography after renal revascularization: spectrum of expected anatomic results and postintervention complications.

The use of magnetic resonance (MR) angiography in screening for renal artery stenosis has been extensively evaluated. However, the MR angiographic findings after renal artery revascularization are not as well characterized. The renal artery and parenchyma can be evaluated after revascularization with a comprehensive MR imaging protocol that includes T1- and T2-weighted spin-echo sequences, three-dimensional (3D) gadolinium-enhanced MR angiography, and 3D phase-contrast MR angiography. Because surgical techniques for revascularization vary, knowledge of the surgical procedure is necessary to ensure inclusion of the pertinent anatomy at 3D gadolinium-enhanced MR angiography and to define appropriate 3D phase-contrast MR angiography volumes. The 3D gadolinium-enhanced MR angiography volume can be manipulated to view relevant vascular anatomy at the optimal obliquity and section thickness. This protocol allows robust, noninvasive evaluation of the expected arterial anatomy after revascularization, including renal artery endarterectomy, aortorenal bypass grafts, and extraanatomic reconstructions. In cases of suspected postrevascularization complications, gadolinium-enhanced MR angiography is useful because of its lack of nephrotoxicity and radiation exposure. Immediate complications of renal revascularization include renal artery thrombosis, renal infarction, and perinephric hemorrhage. Long-term complications include aneurysms of bypass grafts and recurrent stenosis of the renal artery.

Adult↗