Search PubMed⌕ Search

Biomedical subjects

M R Prince

Publications and source records attributed to M R Prince.

At least 19 recordsLinked to original sources

Recessed elliptical-centric view-ordering for contrast-enhanced 3D MR angiography of the carotid arteries.

Fast arterial-venous transit in the carotid arteries requires accurate, reliable timing of the acquisition to the bolus transit to maximize arterial signal and minimize venous artifacts. The rising edge of the bolus is not utilized in conventional elliptical-centric view-ordering because the critical k-space center must be acquired with full arterial enhancement. In this study, a recessed elliptical-centric view-ordering scheme is introduced in which the k-space center is acquired a few seconds following scan initiation. The recessed view-ordering is shown to be more robust to timing errors than the conventional scheme in a study of 37 patients.

Carotid Artery Diseases↗

Interobserver variability in the evaluation of chronic mesenteric ischemia with gadolinium-enhanced MR angiography.

RATIONALE AND OBJECTIVES: The purpose of this study was to assess interobserver variability in the interpretation of gadolinium-enhanced magnetic resonance (MR) angiograms of splanchnic vessels in patients suspected of having chronic mesenteric ischemia (CMI). MATERIALS AND METHODS: Two readers blinded to the initial interpretation retrospectively reviewed gadolinium-enhanced MR angiograms obtained for suspected CMI in 26 patients (20 women and six men; age range, 23-77 years; mean age, 61 years) who also underwent conventional angiography. Each reader graded the degree of stenosis based on the percentage diameter reduction of the celiac artery (CA), superior mesenteric artery (SMA), and inferior mesenteric artery (IMA) by using a five-point ordinal scale: 0, no stenosis: 1, mild stenosis (<50%); 2, moderate stenosis (50%-75%); 3, severe stenosis (>75%); 4, occluded artery. Using the conventional angiogram as a reference standard, authors determined sensitivity and specificity for each observer, assigning two thresholds (grades 2 and 3) as significant stenoses. A kappa statistic (kappa) measured interobserver agreement. RESULTS: With grade 2 stenosis used as a threshold, cumulative accuracies for detecting significant stenosis were 0.95 (95% confidence interval, 0.86-0.99) for reader A and 0.97 (0.88-1.0) for reader B. Interobserver agreement for grading proximal splanchnic stenosis was 0.90 for CA, 0.92 for SMA, and 0.48 for IMA. CONCLUSION: Gadolinium-enhanced MR angiography is reproducibly accurate for detection of proximal splanchnic artery stenosis, with good to excellent interobserver agreement.

Adult↗

Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries: combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions.

UNLABELLED: Wang Y, Winchester PA, Khilnani NM, et al. Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries: Combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions. Invest Radiol 2001;36:170-177. RATIONALE AND OBJECTIVES: To obtain reliable contrast-enhanced peripheral MR angiography for imaging peripheral vascular disease from the abdominal aorta to the pedal arteries. METHODS: A protocol consisting of contrast-enhanced, dynamic two-dimensional (2D) acquisition at the feet and calf and bolus-chase three-dimensional (3D) acquisition from the abdominal aorta to the calf was developed and applied in patients with peripheral vascular disease. The performance of this integrated protocol was assessed in 89 consecutive patients. RESULTS: The bolus-chase 3D acquisition was of diagnostic quality in 100% of the acquisitions in the abdomen, 96% in the thigh, and 43% in the calf. The poor quality of the calf acquisitions was due to insufficient spatial resolution, poor arterial signal, and venous contamination. Diagnostic-quality images were obtained in 100% of the dynamic 2D acquisitions of the calf and 98% of the feet. CONCLUSIONS: The combined dynamic 2D and bolus-chase 3D contrast-enhanced MR angiography technique provides diagnostic images of the entire lower extremity.

Adult↗

Cross-sectional pattern of collateral vessels in patients with superficial femoral artery occlusion.

RATIONALE AND OBJECTIVES: The purpose of this study was to identify the cross-sectional location of collateral vessels in patients with peripheral vascular disease on three-dimensional magnetic resonance angiograms (3D MRAs) to suggest sites for intravascular or transcutaneous angiogenesis gene delivery in the lower extremity. METHODS: The axial locations were measured and categorized by tissue compartments, as well as by radial coordinates with respect to the femur. RESULTS: Collateral vessels in the thigh were identified in 24 of 93 consecutive patients who underwent peripheral 3D MRA. Ninety-one percent (99/109) of the observed collaterals were located near the adductor canal level of the thigh, with 78% (31/46) of these collaterals located in the fat in or surrounding the posterior muscle. CONCLUSIONS: The majority of collateral vessels in the thigh are located in the fat or muscle within the posterior compartment near the femur at the level of the adductor canal.

Adult↗

Coronary MR angiography: selection of acquisition window of minimal cardiac motion with electrocardiography-triggered navigator cardiac motion prescanning--initial results.

The authors developed an electrocardiography-triggered M-mode navigator-echo technique to help monitor cardiac motion and identify the period of minimal cardiac motion in the cardiac cycle. Coronary magnetic resonance angiography was performed in eight healthy adult volunteers and one patient with heart disease. To minimize cardiac motion effects, trigger delays were estimated with the navigator-echo technique and two empirical formulas. The quality of images obtained with the different delay times was compared for clarity of depiction of the coronary arteries. Image quality was best with the delay calculated with the navigator-echo technique.

Adult↗

Anatomically tailored k-Space sampling for bolus-chase three-dimensional MR digital subtraction angiography.

The purpose of this study was to evaluate a variable k-space sampling method for bolus-chase three-dimensional magnetic resonance digital subtraction angiography in the arterial system from the abdomen to the calf. Imaging time was minimized by tailoring the acquisition according to the vascular anatomy of the station. For images obtained in 30 patients, results with the modified protocol were compared to those with the previously published protocol. For all stations, significant improvement (P <.001) was found with the modified protocol.

Adult↗

Venous thrombosis prophylaxis by inflammatory inhibition without anticoagulation therapy.

OBJECTIVE: This study was performed to determine the effectiveness of recombinant P-selectin glycoprotein ligand Ig (rPSGL-Ig) pretreatment to decrease thrombosis and inflammation in experimental venous thrombosis. rPSGL-Ig, a unique mucin-like glycoprotein, has a high affinity for P-selectin. METHODS: Twelve juvenile baboons underwent inferior vena cava (IVC) thrombosis with temporary 6-hour IVC balloon occlusion. Before balloon placement, the animals received rPSGL-Ig (4 mg/kg; n = 8) or saline solution for control (n = 4). The animals underwent evaluation with duplex ultrasound scan imaging, magnetic resonance venography (MRV), phlebography, coagulation profile, and tissue analysis at death for cytokines and vein wall leukocyte morphometrics. With the MRV results, thrombus development, thrombus resolution, and inflammation (gadolinium; square millimeters of enhancement) were assessed. RESULTS: Each animal provided two time points for evaluation (days 2 and 6 after balloon occlusion). A significant decrease in IVC thrombosis between balloons was found in the rPSGL-Ig animals (1 of 16) versus the control animals (5 of 8; P <.01). The MRV results showed significantly less enhancement in the rPSGL-Ig animals at days 2 and 6 (P <.05). Spontaneous thrombus resolution (including balloon sites) was significantly greater from day 2 to day 6 in the rPSGL-Ig animals versus the control animals (23% vs 2%; P <.001), without pulmonary embolism. Lower interleukin-8, platelet factor IV, and monocyte chemotactic protein-1 levels were found in rPSGL-Ig vein walls without significant differences in vein wall leukocyte morphometrics. There were significantly lower D-dimer levels in the rPSGL-Ig-treated animals (P <.05), but there were no differences in measurements of coagulation. Adequate circulating rPSGL-Ig levels were documented. CONCLUSION: Pretreatment with rPSGL-Ig results in: (1) a significant inhibition of thrombosis and vein wall inflammation; (2) a decrease in vein wall cytokine expression; and (3) a promotion of thrombus resolution. Inflammatory inhibition by rPSGL-Ig without anticoagulation therapy provides effective venous thrombosis prophylaxis in experimental venous thrombosis.

Animals↗

Doppler US gating of cardiac MR imaging.

RATIONALE AND OBJECTIVES: Electrocardiographic (ECG) gating of cardiac magnetic resonance (MR) imaging has been problematic for many reasons. The purpose of this study was to demonstrate the feasibility of using Doppler ultrasound (US) gating, either directly off the moving cardiac wall or the systolic upstroke of the arterial signal from the great vessels in neck, in alternative gating modes. MATERIALS AND METHODS: A 2.5-MHz, range-gated Doppler US device was used with A-mode guidance for gating directly off left ventricular wall motion. A 4- or 8.1-MHz, continuous-wave (CW) Doppler US device was used for gating off the systolic upstroke from the great vessels in the neck. The subject undergoing imaging held the transducer against his chest for range-gated Doppler US and against his neck for 8.1-MHz CW Doppler US. The 4-MHz transducer was strapped to the subject's neck. Modified Doppler signals were fed back into the gating circuitry of the MR imager to achieve cardiac synchrony. RESULTS: Cardiac gating was achieved by using both the range-gated technique directly off the cardiac wall and the CW method off blood flow from the great vessels. Problems occurred with radiofrequency shielding during the range-gated method; however, these problems were almost completely removed by use of the CW Doppler probes. CONCLUSION: Doppler US gating of MR images is possible and potentially could overcome many shortcomings of ECG gating. Subsequent embodiments of the technique will require improved radiofrequency shielding in the range-gated technique.

Echocardiography, Doppler↗

Subclavian MR arteriography: reduction of susceptibility artifact with short echo time and dilute gadopentetate dimeglumine.

At arterial phase gadolinium-enhanced magnetic resonance (MR) angiography, artifactual stenosis of the subclavian artery is sometimes seen adjacent to the subclavian vein on the side of the contrast material injection. Experiments in phantoms and in 19 patients showed increased artifact with longer echo time and higher concentration of injected contrast material. An effective method to substantially decrease this susceptibility artifact was threefold dilution of gadopentetate dimeglumine and use of a short echo time (1 msec).

Adolescent↗

Pulmonary magnetic resonance angiography.

Early attempts to image the pulmonary vasculature with spin-echo magnetic resonance (MR) imaging were hampered by severe image degradation related to respiratory and cardiac pulsation artifact, susceptibility at interfaces between lung parenchyma and vessel wall, and poor contrast between flowing blood and intravascular filling defects of emboli. With the development of gradient-echo MR angiographic techniques some of these limitations were overcome; however, the need for multiple breath-holds and the frequent occurrence of flow-related artifacts that could simulate pulmonary emboli diminished their clinical utility. With the development of contrast-enhanced MR angiography, many of the limitations of earlier techniques were addressed. Images of both lungs with high signal-to-noise ratios and high contrast between flowing blood and pulmonary emboli could be acquired in a single breath-hold, during "first-pass" imaging with extracellular contrast agents in the coronal plane. However, subsegmental vessels could not be assessed with this approach. The technique has been refined further by imaging each lung separately in the sagittal plane; this offers higher resolution and total lung coverage and requires a shorter breath-hold. Finally, several investigators have reported preliminary data on imaging of the pulmonary vasculature with blood pool agents, exploiting respiratory triggering or navigator echoes to eliminate the need for breath-holding for the detection of pulmonary emboli.

Aged↗

Magnetic resonance imaging in renal transplantation.

End stage renal disease is common and can result from a variety of diseases. The expense and morbidity of dialysis has made renal transplantation the preferred treatment when it is available. In the United States, 11,000 renal transplants are performed annually. Because of the limited supply of donor organs, every effort is made to salvage the transplanted kidney that has began to fail. Imaging modalities that are currently used to evaluate transplanted kidneys are ultrasound (US), computed tomography (CT), scintigraphy, intravenous urography (IVU), contrast angiography, and magnetic resonance imaging (MRI). MRI offers multiple advantages. MRI provides cross sectional and vascular information without the risks of ionizing radiation, iodinated contrast, or arterial catheterization. This article describes the role of MR imaging in renal transplantation, technical aspects of image acquisition, and MR findings of post-transplantation complications.

Contrast Media↗

MRA contrast bolus timing with ultrasound bubbles.

The purpose of this study was to determine the feasibility of using an ultrasound contrast agent test bolus to determine optimum bolus timing for three-dimensional (3D) gadolinium (Gd)-enhanced magnetic resonance angiography (MRA). Small test doses of ultrasound contrast agent (0.3 ml Optison) were injected intravenously followed immediately by a 20 ml saline flush. Arrival of the contrast agent was detected by spectral Doppler ultrasound (US). This technique was implemented in patients undergoing peripheral vascular MRA and carotid MRA. Arrival of the US contrast agent test bolus was readily detected by the change in amplitude of the Doppler spectrum and by a huge increase in the audio signal amplitude. This contrast travel time measurement accurately guided bolus timing for 3D Gd MRA. Bolus timing for 3D contrast-enhanced MRA can be performed using US, thereby eliminating the problems and MR scanner time required for injecting a test bolus of Gd contrast.

Albumins↗

[MRI of the kidneys. New diagnostic strategies].

AIM: New diagnostic strategies for evaluation of the kidney by fast MR imaging techniques. MATERIAL AND METHODS: A comprehensive morphologic and functional evaluation of the kidney is proposed using fast MR imaging of renal morphology, multiphase 3D gadolinium MR angiography, MR urography and MR flow measurements. A single MR examination is designed to grade renovascular disease and assess the hemodynamic and functional significance, detect and characterize renal lesions and evaluate the urinary tract. RESULTS: The combined analysis of morphologic and functional data allows reliable assessment of renal artery stenosis, benign and malignant renal masses and diseases of the renal collecting system and ureters, as well as congenital abnormalities in good agreement to the results of conventional imaging modalities. The improved tissue contrast and additional functional information compensates for the disadvantage of a lower spatial resolution. CONCLUSION: Combined morphologic and functional MR examination represents a reliable, non-invasive and cost-effective alternative imaging modality for comprehensive diagnostic evaluation of renal disease.

Acute Kidney Injury↗

Diagnosis of pulmonary embolism: comparison of CT angiography and MR angiography in canines.

PURPOSE: To compare the sensitivity and specificity of helical computed tomographic angiography (CTA), CTA with multiplanar reconstructions (MPR)/three-dimensional-shaded surface display (3D-SSD), and gadolinium-enhanced magnetic resonance angiography (MRA) for pulmonary embolism (PE) detection. MATERIALS AND METHODS: Gelatin sponge emboli were introduced into the femoral veins of seven dogs and conventional digital subtraction angiography (CA), CTA, and MRA performed. Images from CTA, CTA with MPR/3D-SSD, and MRA were reviewed for the presence of PE in lobar and segmental arteries, and subsegmental zones. Postmortem angiography and CA were the gold standard. RESULTS: There were 50 emboli in the 294 vessels/zones analyzed. The sensitivity of CTA for the two readers was 76% (95% confidence interval [CI]; 64%-88%) and 64% (95% CI; 50%-78%), and for the two MRA readers was 52% (95% CI; 38%-66%) and 48% (95% CI; 34%-62%). CTA was more sensitive than MRA when PE were subdivided by vessel caliber. Specificity was high for CTA and MRA among all readers (98.8%-99.6%). MPR/3D-SSD did not improve results of axial CT. MRA perfusion defects were 46% and 47% sensitive and 100% specific. Interobserver agreement was high for CTA and MRA (kappa 0.92 and 0.93, respectively). The average diameter of vessels with emboli was 3.7 mm +/- 1.06. CONCLUSION: Helical CTA is more sensitive than three-dimensional gadolinium-enhanced MRA for the detection of PE. Both CTA and MRA are highly specific for PE detection and demonstrate high interobserver agreement. MPR/3D-SSD did not increase CTA performance over axial images alone.

Angiography↗

Abdominal aortic aneurysm. Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: initial report.

OBJECTIVE: To evaluate multiphasic 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for detection of vascular pathology at multiple levels of the aorta and iliac arteries. METHODS: In 18 patients with abdominal aortic aneurysm (n = 13), dissection (n = 3), or both (n = 2), multiphase 3D-Gd-MRA was performed acquiring five consecutive (6.8 seconds) 3D data sets in a single breath-hold. In each of the five time-resolved phases, vessel visibility of the abdominal aortic branches and iliac arteries was assessed. The extent of vessel involvement by the aneurysm or dissection seen on multiphase 3D-Gd-MRA was compared with standard imaging and surgical findings. Digital subtraction angiography was available for comparison in 4 cases, CT angiography in 10 cases. RESULTS: Due to the delayed filling of the aortic aneurysm, the proximal aortic branches and the aneurysm neck demonstrated an inversely related enhancement compared with the distal abdominal and iliac vessels (P < 0.001). Review of all five phases of multiphase 3D-Gd-MRA allowed optimal visualization of each vessel segment without any artifacts due to parenchymal or venous overlay. In dissections, review of three phases was required (P < 0.001) for diagnostic evaluation of the true and false lumens. Substantially more vessel involvement was detected on multiphase 3D-Gd-MRA; this was surgically confirmed in 10 of 11 cases and affected therapy management in 11 of 18 cases. CONCLUSIONS: Multiphase 3D-Gd-MRA is a convenient, robust, and safe technique for presurgical anatomic mapping of complex aortic aneurysms and dissections.

Aortic Dissection↗